Tracor, Inc. | Analytical Chemistry

Portico digital preservation service · ACS Publications. 1155 Sixteenth Street N.W.; Washington, DC 20036; Copyright © 2019. American Chemical Societ...
0 downloads 0 Views 1MB Size
New Products

Reliable. Fast and Easy. MCI automatic analyzer. Incorporates coulometry principle applied to Karl Fischer titration. Operation is full-automatic. Measuring time is shortened. Accuracy is within 5/g—lmg H 2 0 and within 0.5% for 1—30mg H z O. Wide-range applications include measurement of ultra-trace water content in liquids, solids and gases. Range: 10>g—30mg H2O. An optional water vaporizer for speedy and accurate measurement of water content in plastics, grain, etc.

Printer

(optional,

CA-02 Moisture Meter w i t h Printer MITSUBISHI CHEMICAL INDUSTRIES LIMITED Instruments Dept., Mitsubishi Bldg., 5-2, Marunouchi 2-chome, Chiyoda-ku, Tokyo, 100 Japan Telex: J 2 4 9 0 1 Cable Address: KASEICO TOKYO

The liquid chromatography autosampler is designed for use with the SP8000 high-pressure liquid chromatograph. The autosampler is microprocessor controlled by the SP8000. It holds up to 210 samples in multiple test tube racks. Each tube may be covered by a thin plastic cap to prevent evaporation and release of toxic vapors. A sipper needle pierces the cap as each tube is brought to the sampling position, and a peristaltic pump transports the sample to the injector loop of the chromatograph. Spectra-Physics 404

CIRCLE 144 O N READER SERVICE CARD

Liquid Chromatography Instruments from Tracor • Flow rates from .01 to 40 ml/min. • Pressures to 10,000 psi (to 10ml/min) • Compressibility autocompensation • Overpressure control • Constant flow or constant speed • Easy priming • Pressure relief valve • Moderate price

Tracor Model 9 5 0 Pump

CIRCLE 206 O N READER SERVICE CARD Pesticides with Aromatic Hydrocarbons

1 Benzene — 1 2 u g plus Dichlobenil — 200 ng. Naphthalene — 1.6 ug Ronnel — 200 ng Phenanthrene—0.8 « g Pyrene — 1.6 wg

2 3 4 5

The FIRST halogen specific detector for Liquid Chromatography CIRCLE 207 O N READER SERVICE CARD

Tracor, Inc. 6500 Tracor Lane Austin, Texas 78721

Model 572 single-NIM-width nuclear spectroscopy amplifier features a builtin pulse-pileup rejector and gated baseline restorer that includes automatic threshold control. The pulse-pileup rejector significantly reduces background throughout the selected energy range and minimizes spectrum distortion at high count rates. Newly developed active filter pulse-shaping networks result in symmetrical outputs over a wide range of time constants. Excellent dc stability eliminates spectrum broadening caused by dc drift, and enables the user to get the best possible performance out of any modern detector. EG&G Ortec 419

High-Frequency Lock-in Amplifier

Tracor Model 9 6 5 Photo-conductivity Detector

Tracor Instruments

Spectroscopy Amplifier

Telephone 512:926 2800

4 7 2 A • ANALYTICAL CHEMISTRY, VOL. 50, NO. 4, APRIL 1978

Model 5202 100 kHz to 50 MHz lock-in amplifier is a powerful tool for the extraction of low-level signals from background noise. Features include megahertz range performance, microvolt level sensitivity, two-phase operation, high dynamic reserve, dual-channel output zero expansion and time constant, calibrated phase shifter, and a tracking reference channel. Princeton Applied Research Corp. 421