US STONEWARE CO. - ACS Publications - American Chemical Society

May 16, 2012 - U. S. STONEWARE CO. Anal. Chem. , 1955, 27 (7), pp 42A–42A. DOI: 10.1021/ac60103a749. Publication Date: July 1955. ACS Legacy ...
3 downloads 0 Views 1MB Size
NEW PRODUCTS Recording is linear in transmittanee, linear in absorbance, or direct in energy. The built-in recorder presents data on file-size preprinted chart paper. Stand­ ard printed charts are available for the most common ranges on translucent paper for easy Ozalid reproduction. 5

designed apparatus has a three-heat hot plate which permits rapid heating until distillation begins and reduction of heat thereafter to maintain the desired dis­ tillation rate. Vapor locking is prevented by passing the raw solvent feed line through the water-cooled condenser; vapors passing up the feed line are condensed and refluxed back into the retort. This ar­ rangement also serves to preheat the solvent. The still has found application for the recovery and purification of such sol-

Solvent Recovery Still Precision Scientific Co. has redesigned its solvent recovery still used in labora­ tories where large amounts of solvents are employed for extraction. The re-

m TYGON is f l e x i b l e

A new photoelectric recording Raman spectrometer has been brought out by The Perkin-Elmer Corp. for molecular structure studies and quantitative analysis of complex mixtures. The Model R features a Torontotype helical mercury arc excitation source and a coated optical system for transferring Raman radiation from the sample tube to the monochrometer. Dispersion system, wave-length drive, detector, and recorder are similar to components used on standard PerkinElmer infrared spectrometers.

1Γ1Γ©®Μ

2

TYGON is n o n - t o x i c TYGON is m i r r o r - s m o o t h

is the preferred tubing for

3 4

TYGON 1 is n o n - c o n t a m i n a t i n g

5

TYGON is n o n - k i n k i n g

6

TYGON is n o n - c o l l a p s i b l e

LABORATORY USE THE WORLD OVER 7

TYGON is i n e r t

The instrument operates through a frequency range of 100 to 3500 c m . - 1 Survey spectra can be scanned in 12 minutes, high resolution spectra in 50 minutes. Resolution is 5 c m . - 1 for survey work and 2 to 3 c m . - 1 on high resolution spectra. Sample tubes of 20- and 4.5-cc. size are provided. 7

8 Amino Acid Standards

TYGON is i m p e r m e a b l e

9

TYGON is n o n - o x i d i z i n g

ΊΟ

TYGON is s t e r i l i z a b l e

η

TYGON is a v a i l a b l e i n a r a n g e of s i z e s from 1 / 1 6 " I D to 2 " I D Ask f o r — i n s i s t

12

AT YOUR LABORATORY SUPPLY DEALER

on-TYGON It's b r a n d e d for your

For use as primary standards in microbiology, chromatography, and testing, Mann Research Laboratories, Inc., is offering a number of amino acids purified by phase solubility and checked by paper chromatography. · The amino acids are available in two kits. One kit contains 17 natural L-amino acids, the other contains 15 racemic DL-amino acids. 8 Hot Plate-Magnetic Stirrer

protection

U. S. STONEWARE CO. A k r o n 9, Division

Plastics & Synthetics

For further Information, circle number 42 A on Readers' Service Card, page 37 A

42 A

Raman Spectrometer

lob KeoAGUft uiiui

1

TYGON is g l a s s c l e a r

vents as carbon tetrachloride, petroleum ether, benzene, gasoline, alcohol, and other extraction vehicles. 6

Ohio

Stirring and heating in one operation are possible with a combination mag­ netic stirrer and hot plate being mar­ keted by Will Corp. Stirrer and heater will also function separately if desired. The magnetic stirrer utilizes a pulley and belt drive to rotate the permanent For further information, see coupon on page 37 A ANALYTICAL

CHEMISTRY