This technique uses two steps of amplification through chemical reaction to convert pinhole ... on gold1,2are candidates for resists in certain types of patterning (especially by ... First, it makes it possible to count the number of defects in a gol
Chemical Functionalization of Plasmonic Surface Biosensors: A Tutorial Review on Issues, Strategies, and Costs. Manuela Oliverio , Sara Perotto , Gabriele C.
Using Two-Stage Chemical Amplification To Determine the Density of Defects in Self-Assembled Monolayers of Alkanethiolates on Gold. Xiao-Mei Zhao, James ...
This paper describes a technique to measure the surface density of the defects in self-assembled monolayers. (SAMs) of hexadecanethiolates on gold that lead ...
Jan 6, 2015 - aObtained from MarvinSketch Version 14.10.27.0 (https://www.chemaxon.com/). blog DOW is the logarithm ... The values here are calculated at pH 6.5. ...... pollutants: guidance for development and review of POP risk profiles.
Sep 9, 2009 - This material is available free of charge via the Internet at ... Measurement of Atmospheric Ozone by Cavity Ring-down Spectroscopy.
Sep 9, 2009 - Yingdi Liu, Rodrigo Morales-Cueto, James Hargrove, David Medina and ... ZhangYanbo GaiWeijun ZhangDean S. VenablesWeidong Chen.
Oct 31, 2016 - ... Research Institute, University of California, San Francisco, 555 Mission Bay Boulevard South, San Francisco, California 94158, United States.
Jun 3, 2011 - Using Chemical Shifts to Determine Structural Changes in Proteins upon Complex Formation. Andrea Cavalli, Rinaldo W. Montalvao, and ...
5504
Langmuir 1996, 12, 5504
Additions and Corrections Using Two-Stage Chemical Amplification To Determine the Density of Defects in Self-Assembled Monolayers of Alkanethiolates on Gold Xiao-Mei Zhao, James L. Wilbur, and George M. Whitesides* Langmuir 1996, 12 (13), 3257-3264. Table 2 on page 3260 was published with a missing column. The corrected Table 2 is as follows. Table 2. Densities of Pits in HDT-Protected Gold Surfaces (20 nm thick) as a Function of the Composition of the Ferricyanide Solution Used To Etch These Surfacesa etching density [FeIII]/ [Fe(CN)63-] [Fe(CN)64-] [K2S2O3] [KOH] time of pits II [Fe ] (M) (M) (M) (M) (min) (pits/mm2) ∞ 50/1 10/1 1/1 1/10 10/1 10/1 10/1 10/1
0.01 0.01 0.01 0.01 0.01 0.001 0.1 0.01 0.01
0 0.0002 0.001 0.01 0.1 0.0001 0.01 0.001 0.001
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.01 0.1
1 1 1 1 1 1 1 1 0.5
7 7 7 7 7 7 7 10 9.5
210 200 90 550 650 90 90 90 90
a SAMs were prepared by immersing fresh gold substrates (Au 20 nm/Cr 5 nm) in fresh neat HDT for 24 h at 30 °C. All samples were etched at 25 °C. The experiments were performed in a class100 clean room.