This is the heart of the Mettler DSC System.

Chromatography Control Unit C-2 control unit assists in programming chromatographic and other processes where liquid flows have to be critically controlled. Functions include activation and deactivation of pumps, valves, monitors, recorders, and other ancillary equipment on a volume or time basis. Ten different volume (1000 liters/zone) or time (100 hr/zone) zones can be preset to divide the separation process. This unit has a complete manual function control board and a high-speed multiplier for checking the program before a run. Pharmacia Fine Chemicals, Inc. 408

GC-Hydrocarbon Monitors

Coloratiometer

Total hydrocarbon monitors are standard flame ionization gas chromatographs modified for monitoring applications. The units offer ppb sensitivity and can be adapted for continuous monitoring or discrete sample separation. Customer specifications include heated or unheated sampling systems, manual or automated, single or dual channel. The dual-channel model is a modified Model 2440 GC with two sample streams which can provide continuous monitoring and automated discrete batch analysis simultaneouslv. Varian 431

The Monitrek CR-450 coloratiometer consists of an on-stream transmitter and remote converter to measure the relative transmittance of liquid or gaseous products through a process line. The instrument features two side-by-side silicon photodetectors, standard recorder/alarm outputs, and performs on fully pressurized lines from x/2 to 6 in. with a response time of 0.1 sec. The transmittance ratio is from 0.1 to 100% + , and spectral ranges are from 300 to 100 nm. Optical pathlengths are available from 1 mm to 16 cm. Monitor Technology 430

Gas Chromatograph

Laboratory Mini Reactors

The Series 2700 gas chromatograph, a compact, single-column GC, measures 13 x 17 X 12 in. high. The unit is computer compatible, has an allglass flow system, temperature programming capability, and an electrometer with a 107 dynamic range. Other operational features include a self-monitoring system to alert the user of incorrectly set parameters and a column oven operable at room temperature. The flame ionization detection system features controlled support gases. Bendix Corp. 427

Anew line of bench-top reactors offers all of the facilities needed for applying heat, pressure, and vigorous agitation to a wide variety of chemical operations in small vessels having internal volumes of 300, 450, or 600 ml. The units are rated for working pressures to 2000 psig (140 kg/cm 2 ) and temperatures to 350°C. Parr Instrument Co. 434

For more information on listed items, circle the appropriate numbers on one of our Readers' Service Cards

Disposable Cuvettes A new line of cuvettes, available in 1.6, 3.4, and 4.0-ml sizes, is suitable for use in the UV range below 400 nm or from 400 to 760 nm visible. The 3.8-ml round cuvette is specially designed for LKB Automaton. Walter Sarstedt, Inc. 435

The vapor-deposited, thin-film thermopile sensor at the heart of the Mettler scanning calorimeter is revolutionary for a commercial instrument. As a sensor it is fast and responsive—assures excellent heat contact with crucibles. It is ideally suited for accurate purity determinations, as well as heat of fusion, specific heat, and many more measurements. The modular TA 2000 DSC system offers everything you want in thermal analysis. It is more sensitive and reproducible than most comparable instruments. It offers 0.17 millicalories per second full scale sensitivity. And calorimetric reproducibility of ± 0 . 5 % . Noise level is less than ± 1 microcalorie per second. Temperature range covers —20 to 5 0 0 ° C , with precision of ± 0 . 1 °C, and isothermal fluctuations of ± 0 . 0 0 2 ° C . Extremely linear selectable heating and cooling rates in steps of 0.1 °C. Temperature programs can be controlled remotely. It is completely computer compatible. For your copy of the 8-page Mettler TA 2000 brochure, circle the number.

Mettler

CIRCLE 169 ON READER SERVICE CARD