THREE STAGE MERCURY DIFFUSION Ε & Κ Catalog # 0 7 0 0 THREE STAGE MERCURY DIFFUSION PUMP

6700

Speed: 6-100 liters per second depending on pressure after a fore-pressure of 10~ :i is attained. Attainable vacuum: 10 ~s or better Fore-vacuum: 15-20 Torr required Mercury required: 90 ml W a t t required: 600 The low vacuum side tubing is 18 mm The tubing of the high vacuum is approx. 41 mmO.D. The total height is approx. 24". Price: $130.00

6701

O u r Catalog #4123—Electric heater is recom­ mended for this Pump Price: $ 2 . 0 0 E & Κ Catalog # 6 7 0 1 THREE STAGE MERCURY DIFFUSION

Vacuum Pump TRAP Ε & Κ # 2 1 1 8 Designed to fit our #6700 & 6701 Pumps. Trap could be sealed to Pump on request.

2118

Trap length in mm 350

Tubing in mm 41

W e have added as one of our new items this THREE STAGE HIGH SPEED MERCURY DIFFUSION PUMP to our line of Mercury and Oil Diffusion Pumps. This Pump has been successfully tested and used in many Research Laboratories. The speed at which this Pump operates after a 10~ 3 fore pressure is attained, is amazing. The ultimate vacuum of 10~8 or better can easily be obtained. For efficient and dependable performance we feel confident in offering this pump. Write for our catalog.

ECK & KREBS, I N C . M A N U F A C T U R E R S

PUMP

Same as our #6700 except has boiler for gas heating. Price: $125 . 0 0

Trap Dia. in mm 64

PUMP

SCIENTIFIC LABORATORY GLASSWARE MANUFACTURERS OF HY-VACUUM

price $ 9 . 0 0 each

O F

EQUIPMENT

27-09 40th AVE., LONG ISLAND CITY, NEW YORK

TEL. STILLWELL 6-6077-8

N.I.L.-KEEPER OF THE NEW FLAME PHOTOMETER! 4 indispensable methods with the flick of the switch! METHOD

USE

1. Internal standard with lithium base, balanced to a null over 30 inches of 10-turn potentiometer (1000 di­ visions).

1. For highest bility.

2. High speed o u t p u t w i t h internal stand­ ard f o r routine clinical w o r k .

2. Internal standard with readout in milliequivalents directly on meter. 3. Direct reading without standard.

accuracy a n d reproduci­

3. For qualitative and semi-quantitative w o r k . Invaluable f o r screening con­ centration ranges of Na and Κ in urine samples.

internal

4 . For detecting m i n u t e traces and small concentration differences.

4. High sensitivity—5 to 7 times # 1 Method.

UNIQUE FEATURES •

Switch f r o m Ν · to Κ w i t h o u t re-zeroing.



Photo-resistive cells, no photocells.



Fast electronic galvanometer.



24-hour stability—no drift.



Round-the-clock thermal e q u i l i b r i u m .



Single dilution f o r N a a n d K.



Horizontal burner f o r safety a n d cleanliness.



Closed burner system unaffected b y smoke or chemical contaminants.



Equally suitable w i t h p r o p a n e , natural, or city



Interference



Micro



Easy-to-read



Simple trouble-free operation.

gas.

In Metropolitan Washington, D.C.

filters.

samples

as small

scale

for

as 0 . 0 5 m l .

all four

methods.

National Instrument Laboratories, Inc. 12300 Parklawn Drive, Rockville, Maryland

Phone: 933-1144

Bulletin 4-7000

Circle No. 150 on Readers' Service Card

56 A

·

ANALYTICAL CHEMISTRY