Subscriber access provided by NEW YORK UNIV
Article
Effect of corrosion inhibitors on in-situ leak repair by precipitation of calcium carbonate in potable water pipelines Fei Wang, Christina L. Devine, and Marc A. Edwards Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b01380 • Publication Date (Web): 29 Jun 2017 Downloaded from http://pubs.acs.org on June 29, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 32
Environmental Science & Technology
1
Effect of corrosion inhibitors on in-situ leak repair by precipitation of calcium
2
carbonate in potable water pipelines
3 4
Fei Wang, Christina L. Devine and Marc A. Edwards *
5
The Charles E. Via, Jr. Department of Civil & Environmental Engineering
6
Virginia Tech
7
Blacksburg, VA 24061
8 9
*Corresponding author:
10
Durham Hall 407
11
Blacksburg, VA 24061
12
Phone: (540) 231-7236
13
Fax: (540) 231-7916
14
Email:
[email protected] 15 16
To submit to Environmental Science & Technology
17
June 28, 2017
18
1 ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 32
19
Abstract
20
Corrosion inhibitors can affect calcium carbonate precipitation and associated in-situ and
21
in-service water distribution pipeline leak repair via clogging. Clogging of 150 µm
22
diameter leak holes represented by glass capillary tubes, in recirculating solutions that are
23
supersaturated with calcite (Ωcalcite=13), demonstrated that Zn, orthophosphate,
24
tripolyphosphate and hexametaphosphate corrosion/scaling inhibitors hinder clogging but
25
natural organic matter (NOM) has relatively little impact. Critical concentrations of
26
phosphates that could inhibit leak repair over the short term in one water tested were:
27
tripolyphophate (0.05 mg/L as P) < hexametaphosphate (0.1 mg/L) < orthophosphate (0.3
28
mg/L). Inhibitor blends (Zn+orthophosphate and Zn+NOM+orthophosphate) had
29
stronger inhibitory effects compared to each inhibitor (Zn, orthophosphate or NOM)
30
alone, whereas Zn+NOM showed a lesser inhibitory effect than its individual component
31
(NOM) alone presumably due to formation of smaller CaCO3 particles with a much more
32
negative Zeta-potential. Overall, increased dosing of corrosion inhibitors is probably
33
reducing the likelihood of scaling and in-situ and in-service leak repair via clogging with
34
calcium carbonate solids in potable water systems.
35
2 ACS Paragon Plus Environment
Page 3 of 32
Environmental Science & Technology
36
Introduction
37
Calcium carbonate (CaCO3) precipitation has undoubtedly been a critical operational
38
concern since potable water distribution systems were first invented. Waters highly
39
supersaturated with respect to CaCO3 can cause severe scaling problems including pipe
40
blockage and energy loss in heat transfer elements of hot water systems.1 Nearly a
41
century ago, waters that were highly undersaturated with respect to CaCO3 were also
42
assumed to be corrosive to metallic and concrete pipe infrastructure,2 leading to studies
43
attempting to reduce corrosivity by increasing the likelihood of CaCO3 precipitation as
44
monitored with Langelier 3 and similar indices.
45 46
Although use of Langelier index to guide corrosion control fell out of favor,3-7
47
engineering practice and water quality are changing in a manner that will potentially
48
thrust the problems related to CaCO3 back into the spotlight. These changes include (1)
49
potential CaCO3 precipitation inhibitors are now more commonly present naturally or
50
added to distribution systems;8 (2) an increased target temperature (> 51 °C) is suggested
51
for hot water systems in buildings to reduce the growth of pathogens such as Legionella
52
pneumophila;9 (3) rising atmospheric CO2 levels might increase calcium levels in natural
53
waters;10, 11 and (4) increasing use of deicing salt including CaCl2,12, 13 can contribute to
54
higher Ca entering both ground and surface waters.14 Researchers have found that CaCO3
55
particles can clog small leaks in potable water pipes, and may extend the lifetime of
56
distributions systems through both in-situ and in-service leak repair mechanism,15-23
57
highlighting heretofore under-appreciated benefits from CaCO3 scaling in preventing
58
pipeline degradation.
3 ACS Paragon Plus Environment
Environmental Science & Technology
Page 4 of 32
59 60
In-situ and in-service repair of leaks by CaCO3 precipitation is a potentially
61
transformative approach that attempts to use flowing waterborne or waterformed CaCO3
62
solids to clog leaks while a pipeline is still in service. Although there is no record of
63
intentional use of this approach in the context of modern potable water distribution
64
systems, the concept dates back at least to Roman engineers (≈15 BC), who dosed
65
alkaline wood-ash to new terracotta pipelines to permanently seal pressure pipe leaks.24
66
In the 1960s, leaks in concrete pipelines for irrigation waters were sealed by adding
67
anhydrous ammonia to raise pH and induce CaCO3 precipitation.25,
68
CaCO3 lining was attempted to coat the inner surface of potable water pipes to combat
69
corrosion, by targeting supersaturation of CaCO3, although the concept of small leak
70
clogging was never mentioned.27,
71
feasibility of leak crack clogging with CaCO3 precipitation, as a function of
72
supersaturation level (14-30 mg/L of Ca), surface materials (glass, hydraulic cement), and
73
crack widths (10 - 25 µm),22 and other recent studies also demonstrated the capability of
74
water-formed deposits, including CaCO3, to clog leaks and restore some strength of large
75
cracks in reactive new concrete.21 Changes in water supplies that might hinder formation
76
of CaCO3, could potentially leave a water distribution system more vulnerable to damage
77
by disabling processes that once allowed pipes to naturally heal themselves -- an
78
important problem given that upgrading damaged water infrastructure is expected to cost
79
about $1 trillion dollars over the next 25 years.29
28
26
In the 1980s,
Snyder and Letterman explicitly considered the
80 81
Two mechanisms can be operative during in-situ and in-service repair of leaks by CaCO3
4 ACS Paragon Plus Environment
Page 5 of 32
Environmental Science & Technology
82
precipitation.23 Physical clogging can occur when waterborne particles, such as soil,
83
bacteria, sand, clay, Al(OH)3, Fe(OH)3 or CaCO3, seal leaks by blockage. Precipitation on
84
the inner surfaces of leak holes can also seal leaks. Physical clogging and precipitation
85
could occur in pipes of all materials, although the importance of autogenous in-situ and
86
in-service leak repair is believed most important for concrete pipe leaks that have reactive
87
lime present in the matrix.23 Precipitation of CaCO3 is less likely in aged concrete in
88
which lime has been converted to CaCO3. Snyder’s use of inert glass cracks with width of
89
10-25 µm simulated a typical worst-case condition of tiny holes in the aged concrete of
90
the Delaware aqueduct after over 60 years (as of 2007) of exposure to a low alkalinity
91
water prone to leaching of lime.22
92 93
Corrosion inhibitors are now widely added at water utilities,8 and it is logical to suspect
94
they might have inadvertently prevented in-situ and in-service repair by CaCO3
95
precipitation in the last few decades. Specifically, to control lead and copper corrosion in
96
the USA, water treatment plants have been increasingly dosing phosphates and
97
polyphosphates since the advent of the Lead and Copper Rule (LCR) in 1991 by US
98
Environmental Protection Agency (EPA), to meet the action limit for lead of 15 µg/L in
99
tap water.8 Similarly, the Water Supply (Water Quality) Regulations of the United
100
Kingdom, the Drinking Water Directive of the European Union, the Drinking Water
101
Guidelines of Canada, the Drinking Water Standards in Japan, and the Standards for
102
Drinking Water Quality in China, have recently decreased the drinking water standard for
103
lead to 10 ug/L which will increase the impetus for phosphate dosing.30-34 However,
104
phosphates can also prevent CaCO3 precipitation.35,
36
Lin and Singer systematically
5 ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 32
105
studied the inhibitory effects of orthophosphate (PO43-), pyrophosphate (P2O74-),
106
tripolyphosphate (P3O105-), hexametaphosphate (P6O186-) and binary-polyphosphate
107
blends at P concentrations of 10-8 M and above, and suggested that phosphates could
108
adsorb onto calcite crystal growth sites (or kinks) to inhibit calcite precipitation.35,
109
They did not identify threshold values (or the smallest values needed) for phosphates to
110
inhibit CaCO3 precipitation. In addition, NOM (e.g. fulvic acid and humic acid) that are
111
naturally present in aquatic systems, can also inhibit calcite precipitation through a
112
similar mechanism as phosphates.37-39
36
113 114
Zinc cations (or Zn2+) are sometimes present in potable water systems as a byproduct of
115
brass or galvanized iron corrosion, or are sometimes dosed along with phosphates as
116
corrosion inhibitors by water utilities,8 and these practices might also influence the
117
likelihood of leak repair. Addition of Zn2+ by itself at a concentration of 0.1-10 ppm can
118
significantly inhibit calcite precipitation,40, 41 and the formation of aragonite and vaterite
119
in addition to calcite has been observed.40, 42 Ghizellaoui and Euvrard
120
the adsorption of Zn2+ onto calcite crystal growth sites and subsequent blocking (or kink
121
blocking) or the co-precipitation of Zn2+ with CaCO3 might be operative. Wada et al.
122
also found an inhibitory effect by Zn2+, as it favored formation of aragonite instead of
123
calcite. It is possible that this change in mineralogy could also affect the likelihood of
124
scaling problems.
40
suggested that
42
125 126
Changes under consideration for dosing corrosion inhibitors (e.g. phosphates and Zn)
127
may also be important for CaCO3 precipitation in potable water systems. Although water
6 ACS Paragon Plus Environment
Page 7 of 32
Environmental Science & Technology
128
utilities were increasingly dosing phosphate corrosion inhibitors from 1991 to present to
129
control lead and copper corrosion, some water utilities are now considering whether they
130
should decrease the use of phosphates due to initial costs of adding the chemical and later
131
removing it at the sewage treatment plant, and a desire to conserve phosphate
132
resources.43-46 The dosage of Zn may also have been reduced, due to recent studies
133
inability to find it contributes to corrosion control of materials including lead, copper and
134
cement.47, 48 On the other hand, other water utilities are considering the need to increase
135
the levels of phosphates and Zn to better control lead corrosion. A key point is that there
136
is presently pressure on water utilities to consider both increasing or decreasing corrosion
137
inhibitor dose, and an improved understanding of phosphates holistic impacts on water
138
system performance including scaling is much needed.
139 140
The objective of this study was to: (1) Examine leak repair using controlled CaCO3
141
precipitation and determine the effects of corrosion inhibitors on leak repair kinetics and
142
morphology. We hypothesize that small leaks can be blocked via CaCO3 precipitation,
143
and corrosion inhibitors may impair this process, because they also inhibit CaCO3
144
precipitation. (2) Investigate the effect of single inhibitors (Zn, NOM, orthophosphate,
145
tripolyphosphate and hexametaphosphate) on leak repair over a range of conditions
146
relevant to portable water systems. Each corrosion inhibitor can exhibit different degrees
147
of impact on leak repair, because some are better inhibitors of CaCO3 precipitation (e.g.,
148
tripolyphosphate and hexametaphosphate are stronger than orthophosphate). (3)
149
Investigate the effect of mixed inhibitors on leak repair via CaCO3 precipitation, as
150
combinations of inhibitors will sometimes have stronger effects compared to single
7 ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 32
151
inhibitors. (4) Shed light on why some existing pipelines may develop leaks that grow to
152
failure, while other leaks are self-limiting, which may be critical factors to improving the
153
longevity of these critical infrastructure assets.
154 155
Materials and methods
156
Materials
157
Solutions of CaCl2 and NaHCO3 were prepared by dissolving CaCl2·2H2O and NaHCO3
158
(Fisher Scientific) into deionized water. Similarly, solutions of Zn, NOM, orthophosphate
159
(or P1), tripolyphosphate (or P3) and hexametaphosphate (or P6) were prepared using
160
ZnCl2 (Sigma Aldrich), Na3PO4•12H2O (Fisher Scientific), Na5P3O10 and Na8P6O19
161
(Sigma Aldrich).
162 ൛మశ ൟ∙{ைయమష }
163
All test solutions had the same degree of supersaturation (Ω௧ =
164
calcite precipitation, which can be described in terms of the calcite solubility product
165
(Ksp,calcite=10-8.48) and the activities of dissolved Ca2+ and CO32-.
166
Ωcalcite=13 were prepared by adding CaCl2 and NaHCO3 in a 1:1 molar concentration
167
ratio (Table S1). Although Ωcalcite=13 is on the higher end of what is encountered in
168
potable water systems, it was selected to be a “worst case” test of inhibitor effectiveness
169
in preventing scaling.
49, 50
ೞ,ೌ
) to drive
The solutions with
170 171
Methods
172
CaCO3 precipitation and leak repair tests were tracked in recirculation systems with
173
simulated leaks (Figure S1). Initially, glass bottles (or reservoirs) were filled with 2 liter 8 ACS Paragon Plus Environment
Page 9 of 32
Environmental Science & Technology
174
of Ωcalcite=13 solutions. Within 10 minutes of making the solutions, a peristaltic pump
175
(model 7553-70, Cole Parmer) delivered solutions at a flow rate of 1100 mL/min through
176
hard-wall rigid clear PVC tubing (1/4” ID, McMaster Carr). To simulate concrete leaks, a
177
method similar to that of Snyder
178
capillary tubing with 150 µm ID (VitroCom) were mounted onto the side of rigid clear
179
PVC tubing using Epoxy.
22
was used, in which borosilicate heavy-wall glass
180 181
Leak rates through the glass capillaries were measured at certain times (0 h – 24 h) to
182
monitor the kinetics of clogging. Reservoir solution pH was measured every time the leak
183
rates were measured. The pH at t=10 min was measured right after a peristaltic pump
184
initially delivered solutions through the recirculating system, in addition to the initial pH
185
at t=0 min. After the experiments, liquid samples were collected from reservoirs, and
186
solids remaining in the reservoirs were collected using vacuum filtration and dried at
187
room temperature. Liquid samples were analyzed by inductively coupled plasma mass
188
spectroscopy (ICP-MS) for concentrations of dissolved Ca, by laser scattering particle
189
size distribution analyzer (Horiba LA-300) for CaCO3 particle sizes, and by Zeta-Meter
190
for zeta-potential of particles (Model 3.0+, Zeta-Meter, Inc.). Solid samples were
191
characterized by XRD and SEM. Glass capillaries were removed from the recirculation
192
systems and observed with an Amscope microscope (model IN300TC) with digital
193
camera to characterize the nature of the leak repair. Reproducibility was tested by
194
studying the onset of CaCO3 precipitation in the reservoir using beaker tests in triplicates,
195
and the system error was confirmed as