June, 1927

I S D C S T R I A L S S D E-VGISEERISG CHEMISTRY

This test might be worked out along two different lines, one being a modification of Meigs’ method. METHOD I-Meigs stated that the action of sulfur monochloride is a “time reaction,” since the evolution of hydrogen chloride continued for many hours without stopping. The above observations show that in a mixture of saturated and unsaturated hydrocarbons the latter react vigorously and cause the major part of the reaction. The saturated compounds or, better, the saturated chains react slowly and are responsible for the “time reaction.” Therefore the test should be carried out in such a way that after the main reaction and a subsequent heating for a definite short period the absorption of the hydrogen chloride is stopped. h solvent is necessary for higher fractions or crude oils, since they react too violently if mixed direct with sulfur monochloride. Meigs used carbon disulfide for this purpose, but carbon tetrachloride, or another chlorine derivative with a higher boiling point, seems to be preferable, irrespective of the fact that carbon disulfide reacts with sulfur monochloride. This is unquestionably true for the liquid which has the function of absorbing the sulfur chloride vapors which would hydrolyze in water and increase the amount of absorbed hydrogen sulfide. Meigs was obliged to use water as absorbent for the hydrogen chloride since the carbon disulfide vapors would react with the alkali. By the substitution of a chlorine derivative for the carbon disulfide, sodium hydroxide could be used without fear. This is one method which was tried in a few cases. It turned out to be practicable and gave comparative results. A more thorough study is necessary to decide its value in comparison with other methods. METHOD11--4 fexv experiments were carried out in another direction for the purpose of dereloping a testing method. The petroleum fractions were dissolved in carbon tetrachloride and mixed with about half as much sulfur

735

chloride. The mixture was refluxed on a water bath for 2 hours. About an equal amount of water was added to the reaction mixture to hydrolyze it and this mixture was then slo~vlyneutralized by sodium hydroxide. The whole mass was washed with carbon tetrachloride in a separatory funnel. After removing the alkali layer the content of the funnel was mashed with water until neutral. The carbon tetrachloride was driven off and the residue distilled a t an absolute pressure of 30 mm. of mercury. The lowering of the boiling point was taken into account in determining the end point of the distillation. This corresponded to the higher limit of the original range of the fraction. Both distillate and residue were weighed. Either the amount of the residue or that of the distillate subtracted from the original quantity of the petroleum sample could be used as a comparative basis for the degree of unsaturation. This is a second method which seems to be especially useful for testing lower fractions, since there is a considerable difference between the boiling range of the unchanged part of the fraction and that of the polymerized or condensed products. Further Investigations Planned The writer plans to continue the preceding investigations in various directions : (1) More thorough study of the condensation or polymerization products obtained by the action of sulfur monochloride on unsaturated hydrocarbons with regard to their possible sulfur content. (2) Study of the behavior of higher saturated, pure hydrocarbons with sulfur monochloride, with special reference to tertiary carbon atoms. (3) Experiments with unsaturated hydrocarbons from other series than olefins. (4) Testing the two suggested methods for the determination of the degree of unsaturation on various petroleum products and checking the results with other methods.

Effectiveness of Laboratory Rectifying Columns‘ By M. J. Marshall and B. P. Sutherland DEPARTMENT OF CHEMISTRY,UNIVERSITYOF BRITISHCOLUMBIA, VANCOUVER, B. C.

H E ordinary uiifilled Values have been obtained for the effectiveness of purpose of verifying distillal a b o r a t o r y column a lagged Hempel column with reflux, with a view to tion equations, no numerical separat,es almost endetermining the relation between this quantity and values are available for the relative effectiveness of the tirely by partial condensation, reflux ratio. A t the same time, similar data have been while a filled column of the obtained for the same column unlagged and without ordinary laboratory column Hempel type separates by parreflux. These two sets of data have been compared on a and the lagged column protial condensation a t the top common basis to obtain values for the relative effecvided wjth reflux. and in addition rectification tiveness of the two arrangements. Theory for a short distance from the bottom. Now it is generally considered that partial condensaLewis5 has derived an equation giring the change in cointion is neibher so effective nor so efficient as rectification. position of a volatile mixture from plate to plate in a rectifying Experimental evidence of the superior efficiency of rectifica- column as follows: tion over partial condensation has been obtained by Leslie.2 P x, + 1 = Fn - (xc - y n ) (1) It is evident, therefore, that the effectiveness of the ordinary laboratory column can be vastly improved by lagging where s, + I = mol fraction of the more volatile component in the liquid on the n l t h plate the sides and providing reflux, as in commercial columns. = mol fraction of more volatile component in the yn Laboratory columns of this t,ype have been devised by Leslie3 vapor over the nth plate and Peters.4 = mol fraction of the more volatile component in so the distillate Although a number of investigators have obtained values P = mols of distillate per unit time for the effectiveness of small packed columns, largely for t,he

T

+

Received September 27, 1926. 120, Chemical Catalog Co., 1923. a I b i d . , p. 555. THIS JOURNAL, 18, 69 11926).

0

=

1’

=

1

* “Motor Fuels,” p.

6

overflow in mols per unit time from one plate to the other mols of vapor per unit time passing up the column

THISJOURNAL, 14, 492 (1922).

INDUSTRIAL A.1;D ENGINEERING CHEMISTRY

736

Peters6 used this relation in the form % + I

-

-

Yn

-

(1

-P)X~

P

(2),

0

where p = 7. The reflux ratio of Lewis and others is defined as ~90 and is equal to

P r * P

By means of this equation the number of theoretical plates necessary to separate a mixture between any given compositions can be determined. If the column is of the packed type, then the total length divided by the theoretical number of plates gives the height equivalent to a theoretical plate. This quantity, called the H. E. T. P. by Peters, was calculated by him for ring packings of various sizes. These results will be referred to later. Experimental Details

An alcohol-water mixture was chosen as the most suitable medium because so much study has been devoted to the distillation of this mixture, and also because analysis can readily be made by density measurements. The vaporliquid composition data used were those calculated by Lewis’

Vol. 19, No. 6

(0.541 cm.) and filled the column to a depth of 39 inches (99.06 cm.). Reflux was regulated by the pinchcock. The apparatus was run at constant reflux until equilibrium was established. The rate of distillation was then measured at F and samples collected from B and F. Heat was supplied by passing 110-volt a. c. current through a bare nichrome wire at A . The input was measured by means of a wattmeter. The loss of heat through the walls of the flask was determined for various mixtures by noting the watts just necessary to distil over a very small amount of liquid without the use of a column. This amounted to 14.7 calories per second. Correcting for this value, the heat ascending the column per unit time could be calculated. One series of runs was made with the column covered with ordinary steam pipe lagging about 1.5 inches (3.8 cm.) thick, and the tube leading to the condenser covered with several thicknesses of asbestos paper. Another series was made with all this insulation removed and no reflux except that supplied by condensation on the walls of the column. Calculation of Results

The following is a typical calculation (Run 7): Time for 5 cc. distillate, 73 seconds Specific gravity of distillate, 0.8114 = 92.4 per cent alcohol Grams of distillate per second, 0.0556 gram Latent heat of distillate (92.4 per cent alcohol), 230 calories per gram Watts supplied to heating coil, 278 = 66.2 calories per second Radiation loss from flask, 14.7 calories per second Heat in vapor passing up column, 51.5 calories per second 51.5 - 230 X 0.0556 0 = 0.752 p = 7 = 51.5 Mol fractions of alcohol in vapor and distillate are 0.344 and 0.8263, respectively, then from equation (2) 0.334 - (1 - 0.752) X 0.8263 = o,169 XI = 0.752 The mol fraction of alcohol in the vapor in equilibrium with this is 0.539 from the liquid-vapor composition curve. Applying equation (2) once more we get a value for x . ~and in the regular stepwise fashion arrive a t 10.6 plates for the total separation 39 = 3.68 inches (9.35 cm.). obtained. Then H. E. T.P. is 10.6

-

Results for Lagged Column

from the data of Wrewsky.8 This-auve agrees fairly well with the data of Bergstroms and Blacher,lo which were considered by Hausbrand” to be the most accurate values available a t the time of publication. The density tables in the Smithsonian Physical Tables (6th edition) were used to determine the composition. The liter Pyrex flask, A , was covered with asbestos 0.25 inch (6 mm.) thick. The column C was a glass tube 0.827 inch (2.1 cm.)in diameter. The beads were of the ordinary Hempel variety with an average diameter of 0.213 inch 6

THISJOURNAL, 14, 476 (1922).

8

I b i d . , l a , 496 (1920). Z . 9hysik. Chem., 81, 1 (1912).

Jew-Kontoretr Annuler, Bihang. Private communication of Blacher to Hausbrand. 11 “Industrial Distillation,” p. 95, John Wiley & Sons, Inc., 1926. 9

10

The H. E. T. P. values (Table I) vary slightly, although no trend is apparent with increase in vapor velocity, and only a very slight trend with increase in p . Unfortunately, conditions were such that high values of p coincided with high content of alcohol in the product. It is hard, therefore, to determine whether the trend is due to variation of the reflux ratio or the composition of the product. The authors have obtained rather low H. E. T. P. values for runs in which the composition of the product was over 93 per cent. These values are not reported in the present paper because of lack of agreement between duplicate runs. Peters also noticed variation of H. E. T. P. with the composition of the product, although he obtained H. E. T. P. above the average for this range. I t seems more probable, therefore, that any variation of H. E. T. P. will be found to be due to variation of the composition of the product rather than variation of the reflux ratio. It is evident that more determinations of H. E. T. P. are necessary over this range. Because of the nature of the vapor-liquid composition curve at this point, a curve of proved accuracy must be used, and the experimental work must be done with considerable precision in order to obtain even reasonably accurate H. E. T. P. values. Peters6 obtained constant values of H. E. T. P. for acetic acid and water mixtures, using values of p between 0.8 and 1.0, while the present writers’ H. E. T. P. are practically

INDUSTRIAL A N D E-VGINEERING CHEMISTRY

June, 1927

column for any fixed rate of distillation. It appears then that Ay for the two columns should be compared a t equal rates of distillation with maximum possible reflux in the lagged column. It is evident that a direct comparison of the two values for Ay would have only qualitative significance. A quantitative comparison can be made in the following manner: Suppose that we are operating the lagged column a t its maximum reflux ratio with a certain rate of distillation. Suppose that the unlagged column gives us a certain separation Ay1 for the same rate of distillation. We can calculate the number of theoretical plates n1 of the lagged column which would be required, a t the maximum reflux ratio, to give the same separation as that attained by the unlagged column. The ratio of this number of plates to the total number of theoretical plates in the column would be a measure of the relative effectiveness of the two columns under com-

constant for p values between 0.551 and 0.771. With alcohol and water mixtures, using ‘/r-inch rings, he obtained an H. E. T. P. of 3.65 inches (9.27 cm.) below 88 per cent alcohol and 4.2 inches (10.67 cm.) above this percentage. He found ‘/,,-inch rings to be 73 per cent as efficient as the spheres. This would give an H. E. T. P. for the spheres 2.66 inches (7.42 cm.) below 88 per cent alcohol and 3.07 inches (7.80 cm.) above this figure. The average of the writers’ values is 3.92 inches (9.96 cm.), and this can be considered as comparable with Peters’ values above 88 per cent alcohol. While their beads are not strictly equivalent to either rings or spheres, it is evident that their average value approximates more closely to Peters’ value for the rings than for the spheres. In a recent paper Leslie and GeniesseI2 obtained constant H. E. T. P. for variable reflux ratio and variable vapor veTable I-Effectiveness RUN

P

-

0 -

VAPOR VELOC~TY

V

Gramlsec.

0.551 0.569 0.585 0.653 0.734 0.748 0.752 0.771

1 2 3 4 5 6 7 8

0.0917 0.0268 0.0517 0.0628 0.0414 0.0402 0.0556 0.0284

Cal./sec. 48.5 14.7 45.8

41.1 35.6 37.1 51.6 28.5

of Lagged Column a t Varying Reflux Ratio COMPOSITION

-

90.3 90.5 90.4 91.6 92.5 91.7 92.4 92.5

Per cent alcohol b.y weinht 74.5 35.1 75.7 39.2 67.8 22.0 73.3 31.7 78.8 55.5 46.8 6.0 57.2 9.4 43.6 5.6

Study of Unlagged Column

The change in composition of a vapor passing through the unlagged column is undoubtedly due to a combination of rectification and partial condensation. It is evident that this could not be handled by any simple mathematical treatment. For our present purpose, however, this is not necessary. We can regard our unlagged column simply as a device in which vapor undergoes a change Ay in composition on passing through it. No assumptions need be made with respect to what goes on inside. We know from experience that for any fixed composition, yl, of entering vapor, that Ay will vary almost entirely with the rate of distillation. On the other hand, for the lagged column with reflux, Ay will vary with the reflux ratio and the rate of distillation. Either of these variables will be independent until priming occurs in the column. :it this point one variable disappears and Ay varies as the rate of distillation only. That is, to each rate of distillation there corresponds a finite maximum reflux ratio. This point also represents the maximum separation attained by the lagged ‘2

THISJ O U R N A L , 18, 590 (1926). Ibrd , 16, 584 (1924)

SUMBER

Liquid in still

Vapor in still

Product

locity, using chloroform and toluene mixtures. Calingaert and Huggins13 did obtain variation in effectiveneas for variable vapor velocity and reflux ratio with ammonia and water solutions, although they worked a t extremely low concentrations. So, while there is a preponderance of evidence in favor of a constant effectiveness, nevertheless. more work must be done with various mixtures, covering a wide range of vapor velocities and reflux ratios. The percentage of alcohol in both the liquid in the still and the vapor above it were determined for each run. These values are included in the tables. The vapor-liquid composition relations are just about what we would expect from the equilibrium curve. The still itself can therefore be regarded as a perfect plate, and allowance must be made for this rectification in the still when making practical calculations of necessary column lengths.

12

737

PLAT~S

H. E.

Cm.

10.2 9.2 9.0 10.3 10.3 9.2 10.6 11.1

9.70 10.76 11.00 9.60 9.60 10.76 9.35 8.91

T. P. Inches 3.82 4.24 4.33 3.78 3.78 4.24 3.68 3.51

parable conditions. We have shown that the lagged column corresponds to 9.95 perfect plates, and this value can be considered to be independent of the reflux ratio and vapor velocity. Then the relative effectiveness of the two columns would be

nl 9. 96 X

100 per cent.

For some purposes this 9 95 nl

relation can be more effectively expressed as - which is the improvement effected in the unlagged column. We will call this quantity the ‘5mprovement factor.” It should be noted that n is a measure, not of the separation attained, but rather of the relation between the actual and possible separations under similar conditions. I n cases where separations only are being compared, as, for instance, in comparing different types of partial condensation columns, relative separations can be determined by calculating the number of plates at total reflux corresponding to the measured separation. Such a value is identical with the number of perfect redistillations without column necessary to give the measured separation. This can be determined by stepping off points on the vapor-liquid composition curve between initial and final concentrations and taking the arithmetic mean for fractions of a plate. For small separations involving less than one plate, standard integration curves would be more accurate. Values obtained by the former method are included in Table 111. It should be noted in this connection that YoungI4measured the relative effectiveness of various partial condensation * columns by noting the number of redistillations, using an empty tube as a column, necessary to give the same separation as that attained in the column under examination. As his standard still and column would be roughly equivalent to a finite number of plates, his relative values, after correction for rectification in the distillation flask, should be comparable with any obtained by the method outlined above. The authors have found no other data on partial condensation columns in the literature which can be interpreted in similar terms. The maximum p values corresponding to various rates of 1‘

“Fractional Distillation.” p. 146 (1922).

INDUSTRIAL A X D ESGI-YEERI-VG CHEMISTRY

738

distillation have been determined experimentally and are given in Table 11. Values of p for intermediate rates were obtained by interpolation. of M a x i m u m Reflux w i t h Rate of Distillation 0 PRODUCT

Table 11-Variation p

-

7

Gram per second 0 025 0.040 0.065 0.075 0.085 0.100 0.115 0 150

0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.45

p = -

RUN

9 10 11 12 13 14 15 16 17 18 19

Actual measured

0 I'

0.81 0.78 0.77 0.72 0.70 0.67 0.64 0.55 0.44 0.44 0.40

0.644 0.565 0,485 0.406 0.439 0.415 0.344 0.365 0.368 0.204 0.182

2-This height was found to be practically constant for variable reflux between p = 0.53 and p = 0.77, and for distillates up to 92.5 per cent alcohol. It was also found to be independent of the vapor velocity in the few cases where this quantity was varied greatly. 3-The effectiveness of a properly lagged Hempel column 99 cm. long provided with the maximum reflux is 2.4 to 41.5 times as great as that of the same column unlagged and operating a t the same rate of distillation. This improvement factor increases for low alcohol concentrations and high rates of distillation.

1

COMPOSITION

Max. used in calcn.

PRODUCT Product Gram/sec. 0.0354 0.0482 0.0566 0.0708 0.0744 0.0808 0.0894 0.1120 0.1530 0,1544 0 1845

fjq$$

Vapor in still

-

1-The height equivalent to a theoretical plate for alcoholwater mixtures, with a filling of beads 0.213 inch (0.541 cm.) average diameter, was found to be 3.92 inches (9.96 cm.).

-P e..r

I

1.0 4.2 0.2 4.2 3.7 2.9 1.9 0.3 2.2 2.2 n 4

..

r-. ent

10.1 42.2 2.4 42.2 87.2 29.2 19.1 3.3 22.1 22.1 4 1

10.0 2.4 41.5 2.4 2.7 3.4 5.2 29.3 4.5 11 1

,

0.8 3.1 0.2 2.8 2.4 1.9 1.0 0.3 1.0 1.0

nfi

By Marion Hollingsworth THE OHIO STATEUNIVERSITY, COLUMBUS, OHIO

9.95

Summary

SUMBER

RELATIVE IMPROVE- OF EFFECMEN+ PLATES TIVESESS FACTORAT TOTAL REFLUX

Protection of Iron Wire Used for Standardization'

9.95

= 2.7. Values obtained for improvement factor is 3.7 the unlagged column are tabulated in Table 111. The improvement factor reaches a very considerable value in some cases, being highest for low concentrations of alcohol. Other conditions remaining constant, the improoement factor would also vary with the length of the column. However, the authors have not considered it advisable to investigate columns of various lengths, as the object of the investigation is simply to develop a method for obtaining an approximate estimate of the improvement effected in a laboratory column of average length. The values in the last column give a measure of the separation attained in terms of a common unit. The separation is low for high rates of distillation, as would be expected, although it is rather surprising to note that the range over which distillation takes place has an even more marked effect on this quantity. It is evident that the separation attained in the short unlagged Hempel columns used in most laboratories would be even less than the figures given, so that in many cases the larger part of the observed separation would be due to simple rectification in the distilling flask alone. ' For sharp cuts such columns as those developed by Leslie3 or Peters4 are recommended. For the purification of quantities of material, however, the experimental column, described herein, suitably modified, would be equally effective. Comparatively large quantities of material might be easily handled by introducing the feed a t an intermediate point on the column and operating as a continuous still.

EQUIV. PLATES Max. REFLUX AT

(nl)

Per cent alcohol bv weight 68.0 32.2 3.9 90.5 77.3 47.9 26.9 14.0 1.9 89.6 74.1 34.0 89.7 80.3 62.5 89.3 82.6 69.6 82.2 69.6 23.0 58.0 46.6 6.2 86.8 82.0 67.4 84.0 74.7 35.1 77.5 69.0 2 1 .i

Taking Run 13 as an example, we have 0.0744 gram of product per second. This corresponds to a maximum p value of 0.70. The vapor entering the column was 80.3 per cent alcohol, and that leaving it 89.7 per cent. Substituting these values in equation (2) we find that this separation corresponds to 3.7 plates of a perfect column. Then the rela37 tire effectiveness is X 100 = 37.2 per cent, while the

Vol. 19, No. 6

T H E annoyance caused by the rusting and entangling of C. P. iron wire used for standardization purposes has led to the development of the apparatus shown in the accompanying sketch. For the ordinary '/d-pound spool of wire a wide-mouth bottle of 1.5 to 2 liters capacity is a convenient size. The metal strip, A , supporting the spool is about an inch wide, and contains holes as shown in the drawing, B being located opposite or, better, a little above the center of the spool. The strip is made so that it can be readily inserted with the spool through the neck of the bottle. A Iayer of lime, D, covers the bottom of the bottle. On top of this is a layer of cotton, E. The cotton and lime are held in position by a wire gauze, F , which in turn is secured by the spring, G. To make the disk of wire gauze easy to insert, imagine two parallel cords that will divide a diameter perpendicular to them into three a l m o s t e q u a l parts. Cut the gauze on either end of these cords, leaving about an inch for support. The gauze can then be folded on these cords, passed through the neck of the bottle, and again straightened. A test spool of wire kept for three years in such a container shows no sign of rusting. 1

Received March 4, 1927