The Volumetric HPLC Sample Enrichment/Injection Valve SAMPLE SYRINGE

SAMPLE ENRICHMENT COLUMN HPLC DETECTOR

HPLC COLUMN

WASTE 2

A HPLC sample injector has two positions, one for loading and one for injection. Valeo’s new HPLC 10-port can combine the move to load position with column switching thus eliminating the need for a second valve to effect volumetric sample enrichment. The shortened rotation (36° vs. 60) compared to a standard 6-port sample valve increases the valve and the replaceable rotor’s

fpf

lifetime. The elimination of valve to valve tube connections improves resolution by reducing extra column band broadening effects. Only standard syringes are required for loading, i.e., 22 gauge, 2” blunt needle types. Your choice of actuators is available, manual, electric or air. For details on the product along with many unique applications, contact us.

Valeo Instruments Co. Inc.

RO. Box 55603 Houston, Texas 77055 (713) 688-9345 TWX 910-881-5550 Telex 79-0033 CIRCLE 223 ON READER SERVICE CARD

u

l\

ffirfox LABORATORIES

HIGH PRESSURE METERING PUMPS

N

VIS spectra of ions in the form of photodissociation spectra is now well established (34). More recently, acquisition of partial infrared spectra of ions has been accomplished using multiphoton absorption from an IR (CO2) laser (35). These methods should be adaptable to mixture analysis in an MS/MS mode simply by adding suitable high-amplitude pulses to eject unwanted ions from the cell prior to the activation. The exceptional mass resolution of FTMS may make it the method of choice for analysis of high molecular weight materials. There is no mass discrimination inherent in the FTMS detection scheme. The ultrahigh resolution at low mass extrapolates to reasonable resolution at high mass. For example, a resolution of 800 000 at m/z 78 and 1.2 T becomes 8000 at m/z 7800. Increasing the magnetic field by a factor of 10 should permit m/z 7800 to be observed with a resolution of 80 000. Of course, this can only be accomplished if high molecular weight materials can be volatilized and ionized. Pulsed laser desorption, which is compatible with the pulsed FTMS detection, may be appropriate. Fast atom bombardment is another possibility for volatilization of materials that are ionic in the solid state. Advances in FTMS are tied directly to progress in electronics and computers, both of which have been highgrowth technologies. For example, we should expect the addition of sensitive broad-band amplifiers for improving S/N ratios and array processors for doing real-time Fourier transforms in the near future. In conclusion, we point out that the experiments done to date are of a demonstration nature and represent efforts to develop methodology. The real test for FTMS will come when analytical chemists have access to these instruments and apply them to real analytical problems.

Acknowledgment We are particularly indebted to

our

co-workers Sahba Ghaderi, E.B. Ledford, R. L. White, and R. B. Spencer for the progress we’ve made in analytical FTMS. We also thank R. T. Mclver, Jr., and . M. Bursey for helpful comments on this manuscript.

HPLC PUMP SPECIALISTS • Flow Rotes from 0.05-100 mL/min. • Single, Dual 6 Triple Piston Models • Priced from $595

ELDEX LABS

3551 Haven Avenue, Menlo Park, CA 94025 (415) 364-8159

X_______ CIRCLE 63

ON READER SERVICE CARD

References (1) Henis, J. M. S. Anal. Chem. 1969,41 (10), 22-32 A. (2) Gross, M. L.; Wilkins, C. L. Anal. Chem. 1971, 43 (14), 65-68 A. (3) Wilkins, C. L. Anal. Chem. 1978,50, 493-500 A. (4) Mclver, R. T., Jr. Am. Lab. 1980,12, 18-30. (5) Comisarow, . B.; Marshall, A. G. Chem. Phys. Lett. 1974,25, 282-83. (6) Comisarow, . B.; Marshall, A. G. Chem. Phys. Lett. 1974,26, 489-90. (7) Comisarow, . B.; Marshall, A. G. Can. J. Chem. 1974, 52,1997-99.