Subscriber access provided by Queen Mary, University of London
Article
Emission Characteristics of Organic Pollutants During Co-processing of Coal Liquefaction Residue in Texaco Coal-water Slurry Gasifier Xuebing Li, Li Li, Zechun Huang, Da-Hai Yan, Hongjin Yu, and Jie He Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.7b03395 • Publication Date (Web): 08 Jan 2018 Downloaded from http://pubs.acs.org on January 8, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
3
Emission Characteristics of Organic Pollutants during Co-processing of Coal Liquefaction Residue in Texaco Coal-water Slurry Gasifier
4
Xuebing Li†, Li Li†, *, Zechun Huang†, Dahai Yan†, Hongjin Yu†, Jie He†
1 2
5 6
†
State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research
7
Academy of Environmental Sciences, Beijing 100012, China
8
Submitted as manuscript to Energy & Fuels
9
*Corresponding Author: Li Li
10
E-mail:
[email protected] 11
Phone: +86-10-84915182
12
Fax: +86-10-84913903
13 14
Number of pages:
24
15
Number of figures:
7
16
Number of tables:
3
17
Number of words:
6920 word equivalents
18
TOC Art
19 20
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
21
Abstract: Field tests were conducted to research the emission characteristics and environmental
22
risk of organic pollutants during co-processing of coal liquefaction residue (CLR) in Texaco
23
coal-water slurry gasifier. Changes of temperature, pressure and syngas composition in the
24
gasifier were recorded under blank condition (without mixing CLR in the slurry) and test
25
condition (15% CLR were mixed into the slurry). Also the toxicity equivalent concentration of
26
16 kinds of polycyclic aromatic hydrocarbons (PAHs) and Polychlorinated dibenzo-p-dioxins
27
(PCDDs) and Polychlorinated dibenzofurans (PCDFs) and the concentration of volatile organic
28
compounds (VOCs) in all the solid waste, liquid and gas emissions under two conditions were
29
analyzed. Results showed that during the co-processing process, the pressure and syngas
30
production of the gasifier were essentially unaffected, the temperature in gasifier increased 5-11℃
31
and promoted the formation of H2 and CO. The concentration of PAHs in part of the gas
32
emission, liquid emission and solid waste increased 1.0-1.3µg/m3, 19ng/L and 1.4-2.3mg/kg
33
respectively during the co-processing process, but the total toxicity equivalent concentration
34
were still far lower than relevant standard limits, the emission of PAHs during co-processing of
35
CLR in Texaco coal-water slurry gasifier has low environmental risk. The concentration of
36
PCDD/Fs in liquid emission and solid waste decreased 0.002ng TEQ/L and increased 0.0002µg
37
TEQ/kg respectively, the environmental risk was rather low. The concentration of VOCs in gas
38
samples were far below the blank condition under test condition, in the liquid emission and solid
39
waste were mostly not detected or below the detection limits, VOCs emission in the
40
co-processing process has low environmental risk.
ACS Paragon Plus Environment
Page 2 of 25
Page 3 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
41
Energy & Fuels
1 Introduction
42
Polycyclic aromatic hydrocarbons (PAHs) are classified as priority control pollutants in
43
many countries because of its carcinogenicity, teratogenicity, and mutagenicity, which mainly
44
comes from incomplete combustion of fuels such as coal and oil.1-3 Dioxins include
45
Polychlorinated dibenzo-p-dioxins(PCDDs) and Polychlorinated dibenzofurans(PCDFs) are
46
persistent organic pollutants under the Stockholm Convention because they are toxic, persistent
47
and bioaccumulative, which can be performed unintentionally during the incineration of
48
industrial waste and various chlorinated-chemical industrial processes.4-6 Volatile organic
49
compounds(VOCs) which are the mainly cause of photochemical smog can also produced in the
50
high temperature combustion and gasification process.7 PAHs, PCDD/Fs and VOCs are the most
51
concerned organic pollutants in research.
52
Coal liquefaction residue(CLR) is solid waste produced in the process of coal liquefaction
53
production after quenching, high pressure and medium pressure separation, normal pressure and
54
vacuum fractionation to separate low boiling point oil.8 The concentration of PAHs in CLR is
55
higher than in the coal, and the CLR also has a large number of unreacted coal to be recycled.9
56
With high calorific value, the carbon burning efficiency of CLR can reach more than 90%. Due
57
to the conventional combustion mode, it is difficult to use the carbon effectively under its low
58
softening temperature.10 There is no essential difference between the product of coal and CLR
59
gasification according to the study on characteristics of syngas from 5 kinds of CLR.11,12
60
USERDA13,14 analyzed the physical properties and chemical composition of 3 kinds of the CLR,
61
and conducted gasification experiment in Texaco gasifier and obtained yield and composition of
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
62
syngas. All above studies only focused on the syngas quality of the CLR gasification process,
63
lack of research on the emission characteristics of pollutants and environmental risks during the
64
process.
65
Co-processing of hazardous waste in industrial kilns has became one of the important
66
technology development tendency in the world.15-18 Texaco gasification technology is widely
67
applied to methanol and ammonia production process because of its high carbon conversion,
68
efficiency and less impurity in syngas. Coal-water slurry is atomized when it is injected into the
69
Texaco coal-water slurry gasifier with high purity oxygen, partial coal combustion after
70
preheating, moisture evaporation and volatile combustion can soon make the gasifier temperature
71
reach above 1300 ℃ in only fractions of a second, then the high temperature gasification under
72
the internal reducing atmosphere will occur at the high speed rate in a few seconds.19-22 The
73
gasification process which is the main reaction in the gasifier generated syngas mainly consists
74
of CO, H2, CO2 and H2O, higher hydrocarbon completely decomposed with low methane content
75
and no tar substance produced.23,24 Texaco gasification technology is widely applied to methanol
76
and ammonia production process because of its high carbon conversion, efficiency and less
77
impurity in syngas.25,26 Co-processing of CLR in Texaco coal-water slurry gasifier can realize the
78
gasification of CLR meanwhile not be limited to its low melting temperature characteristic.27
79
This study conducted field tests for the first time in China to research the emission
80
characteristics and environmental risks of organic pollutants during co-processing of CLR in
81
Texaco coal-water slurry gasifier. According to comparing the change tendency of temperature,
82
pressure and syngas composition in the gasifier and analysing the toxicity equivalent
ACS Paragon Plus Environment
Page 4 of 25
Page 5 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
83
concentration of PAHs and PCDD/Fs in all the solid waste, liquid and gas emissions under blank
84
condition (without mixing CLR in the slurry) and test condition (15% CLR were mixed into the
85
slurry), we can evaluate the feasibility and environmental risk during the process, would be
86
thegreat technical support to the development of the co-processing technology.
87
2 Materials and Methods
88
2.1 Experimental materials and sampling
89
Experimental materials were CLR generated by corporation B, a coal liquefaction industry
90
enterprise. 48 experimental samples (Table 1) were collected under blank condition (without
91
mixing CLR in the slurry) and test condition (15% CLR were mixed into the slurry). Sampling
92
and analytical methods were shown in Table S1(Supporting information).
93
2.2 Field test methods
94
Field tests were conducted in the Texaco coal-water slurry gasifier which can be used to
95
produce 400kt/a methanol. The flow of the coal-water slurry under blank condition and test
96
condition are both 55m3/h. Methanol production process diagram by Texaco coal-water slurry
97
gasifier was shown in Figure 1 with sampling points marked.
98
2.3 Quality control and quality assurance
99
The extracts of PCDD/Fs samples were analyzed using an Agilent 6890 gas chromatograph
100
coupled with an Autospec Ultima high-resolution mass spectrometer. A DB-5MS fused silica
101
capillary column(60m long, 0.25mm i.d., 0.25mm film thickness) was used. The inlet
102
temperature was 270℃, the carrier gas flow rate was 1mL/min, and splitless injection was used.
103
The oven temperature program started at 160℃(held for 2 min), increased at 7.5℃/min to 220℃
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 6 of 25
104
(held for 16min), increased at 5℃/min to 235℃(held for 7 min), then increased at 5℃/min to
105
330℃(held for 1 min). The mass spectrometer was used in positive electron impact ionization
106
mode. Used selected ion monitoring, and had a resolution>10000.
107
Labotatory blanks were performed, and the analyte concentration in the blanks in most
108
cases found lower than the detection limits or less than 10% of the concentrations in the sample.
109
The limits of detection (LOD) were defined as three times the signal/noise(S/N) ratio. Each
110
concentration below the LOD was replaced with 0.5*LOD when calculating total concentrations
111
and total equivalent quantities (TEQs). Toxicity equivalence factors (TEFs) recommended by the
112
World Health Organization (WHO) were used to calculate the TEQs.28
113
The analysis of VOCs and 16 kinds of PAHs: Naphthalene (Nap), Acenaphthene (Ace),
114
Acenaphthylene (Acy), Fluorene (Flu), Phenanthrene (Phe), Anthracene (Ant), Fluoranthene
115
(Flua), Pyrene (Pyr), Benz[a]anthracene ( BaA ), Chrysene (Chr), Benzo[b]fluoranthene (BbF),
116
Benzo[k]fluoranthene
117
Dibenz[a,h]anthracene (DahA), Benzo[ghi]perylene (BghiP) were conducted using the GC-MS
118
(Agilent7890A/5975C), specific chromatographic conditions were shown in Table S2
119
(Supporting information). Blank recoveries of PAHs and VOCs reported in this study are ranged
120
from 76.8% to 102.6%, from 82.5% to 105.3% respectively, acceptable for trace analysis of
121
PAHs and VOCs as required by the standards shown in Table S1(Supporting information).
(BkF),
Benzo[a]pyrene
(BaP),
ACS Paragon Plus Environment
Indeno[1,2,3-cd]pyrene
(IcdP),
Page 7 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
122
3 Results and Discussions
123
3.1 Influence on the working condition of Texaco gasifier during the co-processing process
124
3.1.1 Influence on syngas generation, pressure and tempreture in the gasifier
125
Figure S1(Supporting information) showed the changes of syngas generation, pressure and
126
temperature in the gasifier withco-process 15% CLR. Results showed that the syngas generation
127
rate ranged from 176000 to 179000Nm3/h and the pressure in the gasifier reached a stable level
128
of 3.71-3.74Mpa. The co-processing process has little influence on syngas generation and
129
pressure.
130
The comparison of the blank condition and the test condition indicates that the temperature
131
under the test condition rises 5-11℃, still in the safe temperature range of the gasifier
132
(1250-1350℃). Co-processing 15% CLR can make an increase of the temperature while the
133
calorific value is higher than the coal,
134
3.1.2 Influence on the components of syngas
135
H2, CO and CO2 are the main components of the syngas, in which H2and CO are feed gas of
136
methanol. Comparing the volume concentration of H2, CO and CO2 in syngas of the two
137
conditions (Figure S2 Supporting information), results showed that the volume concentration of
138
H2 and CO has slight increase, for H2 the volume concentration increased 0.15%, for CO
139
increased 0.41%, while for CO2 declined 0.37%. The main reactions in the Texaco gasifier are as
140
follows:
141
CmHnSr+m/2O2=mCO+(n/2-r)H2+rH2S
(1)
142
CO+H2O=H2+CO2
(2)
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
143
144
(3)
C+CO2=2CO
The concentration increase of H2, CO and the decline of CO2 indicated the co-processing
145
CLR process is beneficial to gas generation.
146
3.2 Emission characteristics of PAHs
147
3.2.1 Concentration of 16 kinds of PAHs in reactive materials
148
In ordinary producing, coal-water slurry was grinded with coal, water and other activated
149
coagent. In co-processing process, CLR was grinded with all other materials. Figure 2 shows
150
concentration of 16 kinds of PAHs in CLR, each of them is higher than the concentration in coal.
151
It can be concluded that plenty of PAHs were produced during the coal liquefaction process.29,30
152
The concentrations of Pyr and BghiP were very high, the sum of the two PAHs get a percentage
153
of 71.1% and 61.2% in coal and CLR respectively.
154
3.2.2 PAHs concentration in gas emissions
155
In the process of methanol production in Texaco coal-water slurry gasifier, there are four
156
exhaust gas: high temperature black water flash steam, desulfurization flash steam,
157
decarburization exhaust gas and methanol membrane separation exhaust gas. Figure 3 showed
158
the concentration of 16 kinds of PAHs in the four exhaust gas. There is an increase in the high
159
temperature black water flash steam and methanol membrane separation exhaust gas, increased
160
35.5% and 60.9% respectively, the concentration of PAHs in desulfurization flash steam and
161
decarburization exhaust gas declined 24.5% and 35.4% respectively.
162
Co-processing 15% CLR can increase the concentration of PAHs in the high temperature
163
black water flash steam and methanol membrane separation exhaust gas, because the PAHs
ACS Paragon Plus Environment
Page 8 of 25
Page 9 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
164
content in the CLR is higher than in the coal, which has contribution to the increase of the PAHs
165
concentration in the process of the gasification. High temperature black water flash steam was
166
generated in the depressurization process, and methanol membrane separation exhaust gas was
167
generated in the process of membrane separation system which can recycle hydrogen and release
168
other impurity gas. For there is no other chemical change in these two process, the PAHs
169
concentration increased after the co-processing process. In addition the CLR and coal can be
170
decomposed into many low molecular weight alkane, olefin and alkynes under the gasification
171
condition. These hydrocarbons can be decomposed into free-radicals under high temperature
172
condition, then the free-radicals can be further converted to PAHs by dehydrogenation and
173
recombinant, and the generated PAHs can also be transformed, therefore each component content
174
would change after co-processing process.
175
Desulfurization flash steam and decarburization exhaust gas are generated by the low
176
temperature methanol decarburization and desulfurization process, in which methanol can absorb
177
H2S, SO2 and partial PAHs. Syngas will enter the following purification process after the acid gas
178
be absorbed, then the absorbent went through the CO2 stripper and H2S concentrating tower,
179
desulfurization flash steam and decarburization exhaust gas generated consequently. Because of
180
the technical fluctuation of leaching process during the co-processing, PAHs absorbed by
181
methanol decreased, which results in PAHs concentration declined in the desulfurization flash
182
steam and decarburization exhaust gas. The concentration of PAHs increased in the methanol
183
membrane separation exhaust gas for more PAHs remained in the membrane separation system.
184 185
3.2.3 PAHs concentration in liquid emissions PAHs in the liquid samples of black water in pressure filter effluent were analyzed. the
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
186
results showed in Figure 4. We found that after co-processing 15% CLR, the PAHs concentration
187
increased, while the total concentration was still low, only 37ng/L. The reason was that the PAHs
188
has properties of hydrophobic-lipophilic which was more likely to be attached to organic matter
189
particles.31 The liquid samples were collected after the clarification, flocculation and filter
190
pressing process, therefore the adsorbing medium was lack, which made a low concentration of
191
PAHs in the water.
192
3.2.4 PAHs concentration in solid emissions
193
Figure 5 showed the concentration of PAHs in the coarse slagof gasifier and fine slag of the
194
black water disposal. After co-processing 15% CLR the concentration of PAHs both in coarse
195
slag and fine slag increased, 1300µg/kg and 2300µg/kg respectively. The concentration of PAHs
196
in fine slag is higher than in coarse slag under both blank condition and test condition, because
197
PAHs are more liable to be adsorbed on the organic particles on solid surface. The concentration
198
of PAHs both in gas and liquid emissions was low but has a significant increase in solid
199
emissions. In addition, fine slag has bigger specific surface area than coarse slag, which has more
200
strong adsorbing ability. Fine slag were generated after high temperature black water flash and
201
subsequent processing, which had a more complete adsorption conversion between air, liquid
202
and solid phases, would have a higher concentration of PAHs than coarse slag.
203
3.3 Emission characteristics of PCDD/Fs
204
PCDD/Fs were detected in the gas samples under the test condition. the TEQ concentration
205
were shown in Figure 6 which calculated with the TEFs recommended by WHO. It was shown
206
that in the high temperature black water flash steam, desulfurization flash steam and
ACS Paragon Plus Environment
Page 10 of 25
Page 11 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
207
decarburization exhaust gas, the concentration of PCDD/Fs under the co-processing condition
208
was rather low, while in the methanol membrane separation exhaust gas it was much higher. The
209
cause was PCDD/Fs are more likely to form in the membrane separation process under the low
210
temperature condition.
211
PCDD/Fs concentration in fine slag and water under the two conditions was shown in
212
Figure 7. Analysis results showed the concentration of PCDD/Fs under the co-processing
213
condition was nearly to the blank condition or even lower. The concentration of PCDD/Fs in the
214
fine slag and in the water are rather low, only 0.001µg/kg and 0.01ng/L respectively.
215
3.4 Emission characteristics of VOCs
216
Table 2 showed the VOCs concentration in gas samples, which were classified to
217
halogenated hydrocarbon,benzene series and halogenated aromatics. The concentration of VOCs
218
has no increase with Co-processing 15% CLR. The concentrations of VOCs are very low under
219
both conditions while VOCs were not detected or below the detection limits in the liquid and
220
solid samples.
221
3.5 Environmental risks of the organic pollutants emission process
222 223
The BaPeq and ΣBaPeq of PAHs are calculated by the PAHs TEF,32 and toxicity equivalent concentration of PAHs in all samples were showed in Table 3.
224
After co-processing 15% CLR, the concentration of PAHs in high temperature black water
225
flash steam increased significantly. And the ΣBaPeq of PAHs is 0.0106µg TEQ/m3, twice than
226
that under blank condition, which exceeded the limited value 0.01µg TEQ/m3 in the Integrated
227
emission standard of air pollutants in China and the Council Directive 2004/107/EC of the
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
228
European Parliament and of the Council (relating to arsenic, cadmium, mercury, nickel and
229
polycyclic aromatic hydrocarbons in ambient air),33,34 has certain environmental risks. The risk
230
of PAHs can be reduced by adding exhaust gas treatment facilities such as torch system to burn
231
the gas or reduce the adding ratio of CLR.
232
Under the two conditions, the ΣBaPeq of desulfurization flash steam, decarburization
233
exhaust gas and methanol membrane separation exhaust gas are far below the limited value
234
0.01µg TEQ/m3 in the Integrated emission standard of air pollutants, so the co-processing
235
process didn’t increase the PAHs emission environmental risks in these exhaust gases.
236
The concentration of PAHs in the water increased after co-processing 15% CLR, however
237
the ΣBaPeq is only 0.00015µg TEQ/L, far below the limited value 0.03µg TEQ/L in the
238
integrated pollutant discharge standard in China and the limited value 0.1ng TEQ/L(calculated
239
by the PAHs TEF) in America.35,36 The environmental risks of PAHs in the water was acceptable.
240
The water can be reused to make coal-water slurry, quench in the vaporizer, or discharged after
241
disposed.
242
The ΣBaPeq of the coarse slag of gasifier and fine slag of the black water disposal after
243
co-processing 15% CLR is 2.0235µg TEQ/kg and 5.2169µg TEQ/kg respectively, which
244
increased significantly. At present, there is no relevant standard for the content of PAHs in solid
245
waste in China. In Canada, the soil quality standard37 was set for the protection of environmental
246
and human health, taking account of the risk of exposure of people under different use of the soil
247
such as agriculture, residence, commerce and agriculture. The limitation of ΣBaPeq of the
248
agriculture soil in that standard was 0.10 mg TEQ/kg, which was the most strict in that standard.
ACS Paragon Plus Environment
Page 12 of 25
Page 13 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
249
In this study the concentration of PAHs in the coarse slag of gas furnace and fine slag of the
250
black water disposal increased after co-processing CLR, whereas the total toxicity concentration
251
is far less than 0.10mg TEQ/kg. So the emission discharge risk of PAHs of the coarse slag of gas
252
furnace and fine slag of the black water disposal during the co-processing process is in the
253
acceptable rang.
254
The concentration of PCDD/Fs in liquid and solid samples and most gas samples are rather
255
low both under blank condition and test condition and have low environmental risks. While
256
under the test condition, the concentration of PCDD/Fs in methanol membrane separation
257
exhaust gas is 0.14ng TEQ/m3 (Figure 6). Now there is no proprietary standard for the limitation
258
of PCDD/Fs concentration in flue gas in co-processing of solid wastes in coal-water slurry
259
gasifier, so according to the Standard for pollution control on the municipal solid waste
260
incineration38 which is the most strict standard with the limit value of 0.1ng TEQ/m3 for
261
PCDD/Fs emission in China, in America and EU the limited value is 0.4ng TEQ/m3 and 0.1ng
262
TEQ/m3 respectively, there are certain risks and the risk of PCDD/Fs in methanol membrane
263
separation exhaust gas can also be reduced by adding exhaust gas treatment facilities such as
264
torch system to burn the gas or reduce the adding ratio of CLR.
265
The concentration of VOCs in gas emission were far below the blank condition under test
266
condition, in the liquid emission and solid waste were mostly not detected or below the detection
267
limits, so VOCs emission in the co-processing process has low environmental risk.
268
4 Conclusions
269
During the co-processing of 15% CLR in Texaco coal-water slurry gasifier process, there
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 14 of 25
270
had little impact on the pressure and syngas output of the gasifier, but made an increase of 5-11℃
271
of the temperature and promoted the formation of H2 and CO. The concentration of PAHs in part
272
of the gas emission and liquid emission increased a little in the co-processing process, but the
273
toxicity equivalent concentration was still far lower than the standard limitation, has low
274
environmental risk. The concentration of PAHs in solid wastes increased significantly in the
275
co-processing process, but the total toxicity equivalent concentration was also low, the
276
environmental risk was in the acceptable range. The emission of PCDD/Fs and VOCs during the
277
co-processing process has low environmental risk. Organic matters were relatively fully
278
degraded during co-processing of CLR in Texaco coal-water slurry gasifier, which would be a
279
new way to dispose certain kinds of solid waste in practice.
280 281
Author Information
282
Corresponding Author
283
*Phone: +86-10-84915182; fax: +86-10-84913903; e-mail:
[email protected]; address: Research
284
Institute of Soil and Solid Waste Management, Chinese Research Academy of Environmental
285
Sciences, No.8, Dayangfang, Anwai, Chaoyang district, Beijing 100012, China.
286
Notes
287
The authors declare no competing financial interest.
288 289
Acknowledgements
290
This research supported by the State Key Laboratory of Environmental Criteria and Risk
ACS Paragon Plus Environment
Page 15 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
291
Energy & Fuels
Assessment, Chinese Research Academy of Environmental Sciences.
292 293
References:
294
(1)
295 296 297 298
Menzie C.A.; Potocki B.B.; Santodonato J. Exposure to carcinogenic PAHs in the
environment. Environ. Sci. Technol. 1992, 26(7), 1278-1284. (2)
Thorsen, W.A.; Cope, W.G.; Shea, D. Bioavailability of PAHs: effects of soot carbon
and PAH source. Environ. Sci. Technol. 2004, 38(7),2029-2037. (3)
Yan, J.; Wang, L.; Fu, P.; Yu, H. Photomutagenicity of 16 polycyclic aromatic
299
hydrocarbons from the US EPA priority pollutant list. Mutation Res./Gene. Toxicol. &
300
Environ. Mutagene. 2004,557(1),99-108.
301
(4)
Abad,
E.;
Martinez,
K.;
Caixach,
J.;
Rivera,
J.
Polychlorinated
302
dibenzo-p-polychlorinated diben-zofuran releases into the atmosphere from the use of
303
secondary fuels in cement kilns during clinker formation. Environ. Sci. Technol.
304
2004,38,4734–8.
305
(5)
Yan, D.; Peng, Z.; Karstensen, K.H.; Ding, Q.; Wang, K.X.; Wang, Z.G. Destruction of
306
DDT wastes in two preheater/precalciner cement kilns in China. Sci. Total Environ. 2014, s
307
476–477,250-257.
308 309 310 311
(6)
UNEP. Stockholm Convention on persistent organic pollutants: United Nations
Environmental Programme. http://chm.pops.int/Convention/ConventionText/,2001. (7)
Kim, Y.M.; Stuart, H.A.; Harrison, R.M. Concentrations and Sources of VOCs in Urban
Domestic and Public Microenvironments. Environ. Sci. Technol. 2001, 35(6),997-1004.
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
312
(8)
Xu, L.; Tang, M.C.; Duan, L.; Liu, B.L.; Ma, X.X.; Zhang, Y.L.; Argyle, M.D.; Fan,
313
M.H. Pyrolysis characteristics and kinetics of residue from China Shenhua industrial direct
314
coal liquefaction plant. Thermochimica Acta. 2014, 589(10),1-10.
315
(9)
Dong, Z.; Yan, D.; He, J.; Luo, L.; Huang, Z. Combustion properties and benzene
316
compound emission characteristics of coal liquefaction residual co-combustion. Res. of
317
Environ. Sci. 2015,28( 8),1253- 1259. (In Chinese)
318
(10) Fang, L. Numerical simulation and experimental study on combustion charateristics of
319
Shenhua coal liquefaction residual and liquefaction residual CWS. Master Dissertation,
320
Zhejiang University, Hangzhou, 2006. (In Chinese).
321 322 323 324 325 326 327 328
(11) Liu, X.; Zhou, Z.; Hu, Q.; Dai, Z.; Wang, F. Experimental study on co-gasification of coal liquefaction residue and petroleum coke. Energy & Fuels, 2011, 25(8),3377-3381. (12) Hites, R. A. Polybrominated diphenyl ethers in the environment and in people: A meta-analysis of concentrations. Environ. Sci. Technol. 2004, 38, 945−956. (13) Child, C.A.; Robin, A.M. Gasification of residual materails from coal liquefaction. USERDA, 1977. (14) Robin, A.M. Gasification of coal liquefaction residues from the Wilsonville SRC pilot plant using the Texaco coal gasification process. USERDA, 1984.
329
(15) Huang, Q.; Yang, Y.; Wang, Q. Potential for Serious Environmental Threats from
330
Uncontrolled Co-processing of Wastes in Cement Kilns. Environ. Sci. Technol. 2012,
331
46(24),13031-2.
332
(16) Yan, D.; Peng, Z.; Ding, Q.; Karstensen, K.H.; Engelsen, C.J.; Li, L.; Ren, Y.; Jiang, C.
ACS Paragon Plus Environment
Page 16 of 25
Page 17 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
333
Distribution of Hg, As and Se in material and flue gas streams from preheater-precalciner
334
cement kilns and vertical shaft cement kilns in China. J. of the Air & Waste Manage.
335
Association. 2015, 65(8),1002-1010.
336
(17) Li, X.; Li, L.; Cong, J.; Yan, D.; Jiang, X.; Wang, Q. Research on condensation and
337
adsorption kinetics of Pb and Cd at low temperatures during co-processing of solid wastes in
338
blast furnaces. Res. of Environ. Sci. 2016, 29(11),1659-1664. (In Chinese).
339
(18) Li, X.; Li, L.; Huang Z.; Yan, D.; Yu, H.; Wang, N. Emission characteristics of
340
polycyclic aromatic hydrocarbons during co-processing of coal liquefaction residue in
341
Texaco coal-water slurry gasifier. China Environ. Sci. 2017, 37(10), 3845-3852. (In
342
Chinese).
343 344
(19) Guo, Q.; Gong, Y.; Xu, J.; Yu, G.; Wang, F. Particulate matter properties in bench-scale entrained-flow coal water slurry gasifier. Power Technol. 2014, 254(2), 125-130.
345
(20) Gong, X.; Lu, W.; Guo X.; Dai, Z.; Liang, Q.; Liu, H.; Zhang, H.; Guo, B. Pilot-scale
346
comparison investigation of different entrained-flow gasification technologies and prediction
347
on industrial-scale gasification performance. Fuel 2014, 129(7), 37-44.
348
(21)
Wu, Y.; Zhang, J.; Smith, P.J.; Zhang, H.; Reid, C.; Lv, J.; Yue, G. Three-dimension
349
simulation for an entrained flow coal slurry gasifier. Energy & Fuels 2010, 24(2),
350
1156-1163.
351 352 353
(22) Qian, F.; Kong, X.; Cheng, H.; Du, W.; Zhong, W. Development of a kinetic model for industrial entrained flow coal gasifier. Ind. Eng. Chem. Res. 2013,52(5), 1819-1828. (23) Choi, Y.C.; Li, X.Y.; Park, T.J.; Kim, J.H.; Lee, J.G. Numerical study on the coal
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
354 355 356
gasification characteristics in an entrained flow coal gasifier. Fuel 2001,80(15), 2193-2201. (24) Al-Salem, S.M.; Lettieri, P.; Baeyens, J. Recycling and recovery routes of plastic solid waste (PSW): a review. Waste Manage. 2009,29(10),2625-2643.
357
(25) Du, Y.; Jiang, X.; Ma, X.; Tang, L.; Wang, M.; Lv, G.; Jin, Y.; Wang, F.; Chi, Y.; Yan, J.
358
Cogasification of biofermenting residue in a coal-water slurry gasifier. Energy & Fuels
359
2014,28(3),2054-2058.
360
(26) Liu, G.; Zhan, J.; Zheng, M.; Li, L.; Li, C.; Jiang, X.; Wang, M.; Zhao, Y.; Jin, R. Field
361
pilot study on emissions, formations and distributions of PCDD/Fs from cement kiln
362
co-processing fly ash from municipal solid waste incinerations. J. of Hazard. Mater. 2015,
363
299,471-478.
364
(27) Bae, J.S.; Lee, D.W.; Park, S.J.; Lee, Y.J.; Hong, J.C.; Ra, H.W.; Han, C; Choi, Y.C.
365
High pressure gasification of coal water ethanol slurry in an entrained flow gasifier for
366
bioethanol application. Energy & Fuels. 2012, 140(1), 451–460.
367
(28) Van den Berg, M., Birnbaum, L.S., Denison, M., De Vito, M., Farland, W., Feeley, M.,
368
Fiedler, H., Hakansson, H., Hanberg, A., Haws, L., 2006, The 2005 World Health
369
Orgnization reevaluation of human and mammalian toxic equivalency fators for dioxins and
370
dioxin-like compounds, Toxicol. Sci. 93, 223-241.
371 372 373 374
(29) Pradhan, V.R.; Tierney J.W.; Wender, I.; Huffman, G.P. Catalysis in direct coal liquefaction by sulfated metal oxides. Energy & Fuels 1991, 5(3), 497-507. (30) Larson, E.D.; Ren, D. Synthetic fuel production by indirect coal liquefaction. Energy for Sustain. Develop. 2003, 7(4), 79-102.
ACS Paragon Plus Environment
Page 18 of 25
Page 19 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
375 376 377 378 379 380
Energy & Fuels
(31) Mcenaney, B.; Masters, K.J. Assessment of adsorption microporous carbons. Thermochimica Acta.1984,82(1), 81-102. (32) Nisbet, I.C.; Lagoy, P.K. Toxic equivalency factors (TEFs) for polycyclic aromatic hydrocarbons (PAHs). Regulatory Toxicol. & Pharmacol. 1992, 16(3), 290. (33) Integrated
emission
standard
of
air
pollutants;
GB16297-1996,
1996;
http://www.mep.gov.cn/image20010518/5302.pdf.
381
(34) EC, 26 January 2005. Council Directive 2004/107/EC of the European Parliament and
382
of the Council (relating to arsenic, cadmium, mercury, nickel and polycyclic aromatic
383
hydrocarbons in ambient air). Official Journal of the European Union L 23, 3-16.
384
(35) Integrated
wastewater
discharge
standard;
GB8978-1996,
1996;
385
http://kjs.mep.gov.cn/hjbhbz/bzwb/shjbh/swrwpfbz/199801/W020061027521858212955.pdf
386
.
387 388 389
(36) USEPA, 1999. National recommendation water quality criteria-correction. Official water 4304, EPA 822-Z-99-001. (37) Canada's environment committee. Canadian soil quality guidelines for the protection of
390
environmental
and
human
health;
CCME,2007;
391
https://en.wikipedia.org/wiki/Canadian_Council_of_Ministers_of_the_Environment.
392
(38) Standard for pollution control on the municipal solid waste incineration; GB
393
18485-2014,2014;http://kjs.mep.gov.cn/hjbhbz/bzwb/gthw/gtfwwrkzbz/201405/W02014053
394
0531389708182.pdf.
395
ACS Paragon Plus Environment
Energy & Fuels
396
397 398
Figure 1. Methanol production process diagram by Texaco coal-water slurry gasifier
399 400
45 PAHs in CLR
PAHs in coal
35
300
30 250 25 200 20 150 15 100
10
50
5 0
0 Nap Ace Acy
400 401
Flu
Phe
Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahABghiP PAHs
Figure 2. Concentration of 16 kinds of PAHs in reactive materials
402
ACS Paragon Plus Environment
PAHs concentration in coal(mg/kg)
40
350 PAHs concentration in CLR(mg/kg)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 20 of 25
Page 21 of 25
5
Nap Ace Acy Flu Phe Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahA BghiP
PAHs concentration(µg/m3)
4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 avrblkS1 avrS1 avrblkS2 avrS2 avrblkS3 avrS3 avrblkS4 avrS4 number of samples
403 404
Figure 3. PAHs concentration in gas emissions
405 40
Nap Ace Acy Flu Phe Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahA BghiP
35 PAHs concentration(ng/L)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
30 25 20 15 10 5 0 avrblkS5
406 407
avrS5 number of samples
Figure 4. PAHs concentration in liquid emissions
ACS Paragon Plus Environment
Energy & Fuels
4500
Nap Ace Acy Flu Phe Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahA BghiP
PAHs concentration(µg/kg)
4000 3500 3000 2500 2000 1500 1000 500 0 avrblkS6
408 409
avrS6 avrblkS7 number of samples
avrS7
Figure 5. PAHs concentration in solid emissions
410 0.16 PCDD/Fs concentration(ng TEQ/m3)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 22 of 25
0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 S1
S2
S3 number of samples
S4
411 412
Figure 6. PCDD/Fs concentration in gas emissions under test condition
413
ACS Paragon Plus Environment
2,3,7,8-T4CDD 1,2,3,7,8-P5CDD 1,2,3,4,7,8-H6CDD 1,2,3,6,7,8-H6CDD 1,2,3,7,8,9-H6CDD 1,2,3,4,6,7,8-H7CDD OCDD 2,3,7,8-T4CDF 1,2,3,7,8-P5CDF 2,3,4,7,8-P5CDF 1,2,3,4,7,8-H6CDF 1,2,3,6,7,8-H6CDF 1,2,3,7,8,9-H6CDF 2,3,4,6,7,8-H6CDF 1,2,3,4,6,7,8-H7CDF 1,2,3,4,7,8,9-H7CDF OCDF
0.0015
PCDD/Fs concentration(ng TEQ/L)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
PCDD/Fs concentration(µg TEQ/kg)
Page 23 of 25
a 0.001
0.0005
0 blkS5 S5 number of samples
417
2,3,7,8-T4CDD 1,2,3,7,8-P5CDD 1,2,3,4,7,8-H6CDD 1,2,3,6,7,8-H6CDD 1,2,3,7,8,9-H6CDD 1,2,3,4,6,7,8-H7CDD OCDD 2,3,7,8-T4CDF 1,2,3,7,8-P5CDF 2,3,4,7,8-P5CDF 1,2,3,4,7,8-H6CDF 1,2,3,6,7,8-H6CDF 1,2,3,7,8,9-H6CDF 2,3,4,6,7,8-H6CDF 1,2,3,4,6,7,8-H7CDF 1,2,3,4,7,8,9-H7CDF OCDF
b 0.01
0.005
0 blkS7 S7 number of samples
414 415 416
0.015
Figure 7. PCDD/Fs concentration in solid and liquid emissions
Table 1. Field test samples
Number of Samples
Sampling points
Frequency ①
samples ②
S1 High temperature black water flash steam
Flashing tower exhaust port
3
S1test1-3
S2Desulfurization flash steam
Desulfurizing tower exhaust port
5
S2test1-5
S3Decarburization exhaust gas
Decarburization tower exhaust port
5
S3test1-5
S4Methanol membrane separation exhaust gas
Rectifying tower exhaust port
5
S4test1-5
S5Water
Delivery tank
2
S5test1-2
S6Coarse slag
Slag-dripping port
2
S6test1-2
S7Fine slag
Pressure filter port
2
S7test1-2
418
①:blk means samples under blank condition, avr means average value of each kind of sample
419
②:Sampling points in Figure1
420 421
Table 2. VOCs concentration in gas samples
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Gas samples Halogenated hydrocarbon (mg/m3)
Page 24 of 25
Blank condition
Test condition
2.8±1.5
1.4±1.6
15.9±1.1
16.9±0.7
0.004
ND
8.4±4.2
11.3±5.4
6.7±0.82
8.1±1.0
0.004
N.D.
1.6±0.39
0.25±0.083
1.8±0.15
2.1±0.12
0.0082±0.0082
N.D.
N.D.
N.D.
0.85±0.16
0.82±0.064
N.D.
0.004
High temperature black water flash Benzene series (mg/m3) steam Halogenated aromatics (mg/m3) Halogenated hydrocarbon (mg/m3) Benzene series(mg/m3)
Desulfurization flash steam
Halogenated aromatics (mg/m3) Halogenated hydrocarbon (mg/m3) Benzene series(mg/m3)
Decarburization exhaust gas
Halogenated aromatics (mg/m3) Halogenated hydrocarbon (mg/m3) Methanol membrane separation Benzene series(mg/m3) exhaust gas Halogenated aromatics (mg/m3)
422 423
Table 3. Toxicity equivalent concentration of PAHs in all samples Samples
Blank condtion ΣBaPeq
Test condition ΣBaPeq
High temperature black water flash steam S1(µg/m3)
0.0045±0.0008
0.0106±0.0039
Desulfurization flash steam S2(µg/m3)
0.0100±0.0049
0.0091±0.0061
Decarburization exhaust gas S3(µg/m3)
0.0081±0.0079
0.0034±0.0011
Methanol membrane separation exhaust gas S4(µg/m3)
0.0044±0.0027
0.0046±0.0016
0.1460±0.0063
0.1676±0.0114
1.3850±0.1339
2.0235±0.0695
Water S5(ng/L)
Coarse slag S6(µg/kg)
ACS Paragon Plus Environment
Page 25 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
Fine slag S7(µg/kg)
3.3602±0.1346
424 425
ACS Paragon Plus Environment
5.2169±0.4748