Emission Characteristics of Organic Pollutants ... - ACS Publications

Jan 8, 2018 - •S Supporting Information. ABSTRACT: Field tests were conducted to research the emission characteristics and environmental risk of org...
1 downloads 10 Views 868KB Size
Subscriber access provided by Queen Mary, University of London

Article

Emission Characteristics of Organic Pollutants During Co-processing of Coal Liquefaction Residue in Texaco Coal-water Slurry Gasifier Xuebing Li, Li Li, Zechun Huang, Da-Hai Yan, Hongjin Yu, and Jie He Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.7b03395 • Publication Date (Web): 08 Jan 2018 Downloaded from http://pubs.acs.org on January 8, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

3

Emission Characteristics of Organic Pollutants during Co-processing of Coal Liquefaction Residue in Texaco Coal-water Slurry Gasifier

4

Xuebing Li†, Li Li†, *, Zechun Huang†, Dahai Yan†, Hongjin Yu†, Jie He†

1 2

5 6



State Key Laboratory of Environmental Criteria and Risk Assessment, Chinese Research

7

Academy of Environmental Sciences, Beijing 100012, China

8

Submitted as manuscript to Energy & Fuels

9

*Corresponding Author: Li Li

10

E-mail: [email protected]

11

Phone: +86-10-84915182

12

Fax: +86-10-84913903

13 14

Number of pages:

24

15

Number of figures:

7

16

Number of tables:

3

17

Number of words:

6920 word equivalents

18

TOC Art

19 20

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

21

Abstract: Field tests were conducted to research the emission characteristics and environmental

22

risk of organic pollutants during co-processing of coal liquefaction residue (CLR) in Texaco

23

coal-water slurry gasifier. Changes of temperature, pressure and syngas composition in the

24

gasifier were recorded under blank condition (without mixing CLR in the slurry) and test

25

condition (15% CLR were mixed into the slurry). Also the toxicity equivalent concentration of

26

16 kinds of polycyclic aromatic hydrocarbons (PAHs) and Polychlorinated dibenzo-p-dioxins

27

(PCDDs) and Polychlorinated dibenzofurans (PCDFs) and the concentration of volatile organic

28

compounds (VOCs) in all the solid waste, liquid and gas emissions under two conditions were

29

analyzed. Results showed that during the co-processing process, the pressure and syngas

30

production of the gasifier were essentially unaffected, the temperature in gasifier increased 5-11℃

31

and promoted the formation of H2 and CO. The concentration of PAHs in part of the gas

32

emission, liquid emission and solid waste increased 1.0-1.3µg/m3, 19ng/L and 1.4-2.3mg/kg

33

respectively during the co-processing process, but the total toxicity equivalent concentration

34

were still far lower than relevant standard limits, the emission of PAHs during co-processing of

35

CLR in Texaco coal-water slurry gasifier has low environmental risk. The concentration of

36

PCDD/Fs in liquid emission and solid waste decreased 0.002ng TEQ/L and increased 0.0002µg

37

TEQ/kg respectively, the environmental risk was rather low. The concentration of VOCs in gas

38

samples were far below the blank condition under test condition, in the liquid emission and solid

39

waste were mostly not detected or below the detection limits, VOCs emission in the

40

co-processing process has low environmental risk.

ACS Paragon Plus Environment

Page 2 of 25

Page 3 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

41

Energy & Fuels

1 Introduction

42

Polycyclic aromatic hydrocarbons (PAHs) are classified as priority control pollutants in

43

many countries because of its carcinogenicity, teratogenicity, and mutagenicity, which mainly

44

comes from incomplete combustion of fuels such as coal and oil.1-3 Dioxins include

45

Polychlorinated dibenzo-p-dioxins(PCDDs) and Polychlorinated dibenzofurans(PCDFs) are

46

persistent organic pollutants under the Stockholm Convention because they are toxic, persistent

47

and bioaccumulative, which can be performed unintentionally during the incineration of

48

industrial waste and various chlorinated-chemical industrial processes.4-6 Volatile organic

49

compounds(VOCs) which are the mainly cause of photochemical smog can also produced in the

50

high temperature combustion and gasification process.7 PAHs, PCDD/Fs and VOCs are the most

51

concerned organic pollutants in research.

52

Coal liquefaction residue(CLR) is solid waste produced in the process of coal liquefaction

53

production after quenching, high pressure and medium pressure separation, normal pressure and

54

vacuum fractionation to separate low boiling point oil.8 The concentration of PAHs in CLR is

55

higher than in the coal, and the CLR also has a large number of unreacted coal to be recycled.9

56

With high calorific value, the carbon burning efficiency of CLR can reach more than 90%. Due

57

to the conventional combustion mode, it is difficult to use the carbon effectively under its low

58

softening temperature.10 There is no essential difference between the product of coal and CLR

59

gasification according to the study on characteristics of syngas from 5 kinds of CLR.11,12

60

USERDA13,14 analyzed the physical properties and chemical composition of 3 kinds of the CLR,

61

and conducted gasification experiment in Texaco gasifier and obtained yield and composition of

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

62

syngas. All above studies only focused on the syngas quality of the CLR gasification process,

63

lack of research on the emission characteristics of pollutants and environmental risks during the

64

process.

65

Co-processing of hazardous waste in industrial kilns has became one of the important

66

technology development tendency in the world.15-18 Texaco gasification technology is widely

67

applied to methanol and ammonia production process because of its high carbon conversion,

68

efficiency and less impurity in syngas. Coal-water slurry is atomized when it is injected into the

69

Texaco coal-water slurry gasifier with high purity oxygen, partial coal combustion after

70

preheating, moisture evaporation and volatile combustion can soon make the gasifier temperature

71

reach above 1300 ℃ in only fractions of a second, then the high temperature gasification under

72

the internal reducing atmosphere will occur at the high speed rate in a few seconds.19-22 The

73

gasification process which is the main reaction in the gasifier generated syngas mainly consists

74

of CO, H2, CO2 and H2O, higher hydrocarbon completely decomposed with low methane content

75

and no tar substance produced.23,24 Texaco gasification technology is widely applied to methanol

76

and ammonia production process because of its high carbon conversion, efficiency and less

77

impurity in syngas.25,26 Co-processing of CLR in Texaco coal-water slurry gasifier can realize the

78

gasification of CLR meanwhile not be limited to its low melting temperature characteristic.27

79

This study conducted field tests for the first time in China to research the emission

80

characteristics and environmental risks of organic pollutants during co-processing of CLR in

81

Texaco coal-water slurry gasifier. According to comparing the change tendency of temperature,

82

pressure and syngas composition in the gasifier and analysing the toxicity equivalent

ACS Paragon Plus Environment

Page 4 of 25

Page 5 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

83

concentration of PAHs and PCDD/Fs in all the solid waste, liquid and gas emissions under blank

84

condition (without mixing CLR in the slurry) and test condition (15% CLR were mixed into the

85

slurry), we can evaluate the feasibility and environmental risk during the process, would be

86

thegreat technical support to the development of the co-processing technology.

87

2 Materials and Methods

88

2.1 Experimental materials and sampling

89

Experimental materials were CLR generated by corporation B, a coal liquefaction industry

90

enterprise. 48 experimental samples (Table 1) were collected under blank condition (without

91

mixing CLR in the slurry) and test condition (15% CLR were mixed into the slurry). Sampling

92

and analytical methods were shown in Table S1(Supporting information).

93

2.2 Field test methods

94

Field tests were conducted in the Texaco coal-water slurry gasifier which can be used to

95

produce 400kt/a methanol. The flow of the coal-water slurry under blank condition and test

96

condition are both 55m3/h. Methanol production process diagram by Texaco coal-water slurry

97

gasifier was shown in Figure 1 with sampling points marked.

98

2.3 Quality control and quality assurance

99

The extracts of PCDD/Fs samples were analyzed using an Agilent 6890 gas chromatograph

100

coupled with an Autospec Ultima high-resolution mass spectrometer. A DB-5MS fused silica

101

capillary column(60m long, 0.25mm i.d., 0.25mm film thickness) was used. The inlet

102

temperature was 270℃, the carrier gas flow rate was 1mL/min, and splitless injection was used.

103

The oven temperature program started at 160℃(held for 2 min), increased at 7.5℃/min to 220℃

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 25

104

(held for 16min), increased at 5℃/min to 235℃(held for 7 min), then increased at 5℃/min to

105

330℃(held for 1 min). The mass spectrometer was used in positive electron impact ionization

106

mode. Used selected ion monitoring, and had a resolution>10000.

107

Labotatory blanks were performed, and the analyte concentration in the blanks in most

108

cases found lower than the detection limits or less than 10% of the concentrations in the sample.

109

The limits of detection (LOD) were defined as three times the signal/noise(S/N) ratio. Each

110

concentration below the LOD was replaced with 0.5*LOD when calculating total concentrations

111

and total equivalent quantities (TEQs). Toxicity equivalence factors (TEFs) recommended by the

112

World Health Organization (WHO) were used to calculate the TEQs.28

113

The analysis of VOCs and 16 kinds of PAHs: Naphthalene (Nap), Acenaphthene (Ace),

114

Acenaphthylene (Acy), Fluorene (Flu), Phenanthrene (Phe), Anthracene (Ant), Fluoranthene

115

(Flua), Pyrene (Pyr), Benz[a]anthracene ( BaA ), Chrysene (Chr), Benzo[b]fluoranthene (BbF),

116

Benzo[k]fluoranthene

117

Dibenz[a,h]anthracene (DahA), Benzo[ghi]perylene (BghiP) were conducted using the GC-MS

118

(Agilent7890A/5975C), specific chromatographic conditions were shown in Table S2

119

(Supporting information). Blank recoveries of PAHs and VOCs reported in this study are ranged

120

from 76.8% to 102.6%, from 82.5% to 105.3% respectively, acceptable for trace analysis of

121

PAHs and VOCs as required by the standards shown in Table S1(Supporting information).

(BkF),

Benzo[a]pyrene

(BaP),

ACS Paragon Plus Environment

Indeno[1,2,3-cd]pyrene

(IcdP),

Page 7 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

122

3 Results and Discussions

123

3.1 Influence on the working condition of Texaco gasifier during the co-processing process

124

3.1.1 Influence on syngas generation, pressure and tempreture in the gasifier

125

Figure S1(Supporting information) showed the changes of syngas generation, pressure and

126

temperature in the gasifier withco-process 15% CLR. Results showed that the syngas generation

127

rate ranged from 176000 to 179000Nm3/h and the pressure in the gasifier reached a stable level

128

of 3.71-3.74Mpa. The co-processing process has little influence on syngas generation and

129

pressure.

130

The comparison of the blank condition and the test condition indicates that the temperature

131

under the test condition rises 5-11℃, still in the safe temperature range of the gasifier

132

(1250-1350℃). Co-processing 15% CLR can make an increase of the temperature while the

133

calorific value is higher than the coal,

134

3.1.2 Influence on the components of syngas

135

H2, CO and CO2 are the main components of the syngas, in which H2and CO are feed gas of

136

methanol. Comparing the volume concentration of H2, CO and CO2 in syngas of the two

137

conditions (Figure S2 Supporting information), results showed that the volume concentration of

138

H2 and CO has slight increase, for H2 the volume concentration increased 0.15%, for CO

139

increased 0.41%, while for CO2 declined 0.37%. The main reactions in the Texaco gasifier are as

140

follows:

141

CmHnSr+m/2O2=mCO+(n/2-r)H2+rH2S

(1)

142

CO+H2O=H2+CO2

(2)

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

143

144

(3)

C+CO2=2CO

The concentration increase of H2, CO and the decline of CO2 indicated the co-processing

145

CLR process is beneficial to gas generation.

146

3.2 Emission characteristics of PAHs

147

3.2.1 Concentration of 16 kinds of PAHs in reactive materials

148

In ordinary producing, coal-water slurry was grinded with coal, water and other activated

149

coagent. In co-processing process, CLR was grinded with all other materials. Figure 2 shows

150

concentration of 16 kinds of PAHs in CLR, each of them is higher than the concentration in coal.

151

It can be concluded that plenty of PAHs were produced during the coal liquefaction process.29,30

152

The concentrations of Pyr and BghiP were very high, the sum of the two PAHs get a percentage

153

of 71.1% and 61.2% in coal and CLR respectively.

154

3.2.2 PAHs concentration in gas emissions

155

In the process of methanol production in Texaco coal-water slurry gasifier, there are four

156

exhaust gas: high temperature black water flash steam, desulfurization flash steam,

157

decarburization exhaust gas and methanol membrane separation exhaust gas. Figure 3 showed

158

the concentration of 16 kinds of PAHs in the four exhaust gas. There is an increase in the high

159

temperature black water flash steam and methanol membrane separation exhaust gas, increased

160

35.5% and 60.9% respectively, the concentration of PAHs in desulfurization flash steam and

161

decarburization exhaust gas declined 24.5% and 35.4% respectively.

162

Co-processing 15% CLR can increase the concentration of PAHs in the high temperature

163

black water flash steam and methanol membrane separation exhaust gas, because the PAHs

ACS Paragon Plus Environment

Page 8 of 25

Page 9 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

164

content in the CLR is higher than in the coal, which has contribution to the increase of the PAHs

165

concentration in the process of the gasification. High temperature black water flash steam was

166

generated in the depressurization process, and methanol membrane separation exhaust gas was

167

generated in the process of membrane separation system which can recycle hydrogen and release

168

other impurity gas. For there is no other chemical change in these two process, the PAHs

169

concentration increased after the co-processing process. In addition the CLR and coal can be

170

decomposed into many low molecular weight alkane, olefin and alkynes under the gasification

171

condition. These hydrocarbons can be decomposed into free-radicals under high temperature

172

condition, then the free-radicals can be further converted to PAHs by dehydrogenation and

173

recombinant, and the generated PAHs can also be transformed, therefore each component content

174

would change after co-processing process.

175

Desulfurization flash steam and decarburization exhaust gas are generated by the low

176

temperature methanol decarburization and desulfurization process, in which methanol can absorb

177

H2S, SO2 and partial PAHs. Syngas will enter the following purification process after the acid gas

178

be absorbed, then the absorbent went through the CO2 stripper and H2S concentrating tower,

179

desulfurization flash steam and decarburization exhaust gas generated consequently. Because of

180

the technical fluctuation of leaching process during the co-processing, PAHs absorbed by

181

methanol decreased, which results in PAHs concentration declined in the desulfurization flash

182

steam and decarburization exhaust gas. The concentration of PAHs increased in the methanol

183

membrane separation exhaust gas for more PAHs remained in the membrane separation system.

184 185

3.2.3 PAHs concentration in liquid emissions PAHs in the liquid samples of black water in pressure filter effluent were analyzed. the

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

186

results showed in Figure 4. We found that after co-processing 15% CLR, the PAHs concentration

187

increased, while the total concentration was still low, only 37ng/L. The reason was that the PAHs

188

has properties of hydrophobic-lipophilic which was more likely to be attached to organic matter

189

particles.31 The liquid samples were collected after the clarification, flocculation and filter

190

pressing process, therefore the adsorbing medium was lack, which made a low concentration of

191

PAHs in the water.

192

3.2.4 PAHs concentration in solid emissions

193

Figure 5 showed the concentration of PAHs in the coarse slagof gasifier and fine slag of the

194

black water disposal. After co-processing 15% CLR the concentration of PAHs both in coarse

195

slag and fine slag increased, 1300µg/kg and 2300µg/kg respectively. The concentration of PAHs

196

in fine slag is higher than in coarse slag under both blank condition and test condition, because

197

PAHs are more liable to be adsorbed on the organic particles on solid surface. The concentration

198

of PAHs both in gas and liquid emissions was low but has a significant increase in solid

199

emissions. In addition, fine slag has bigger specific surface area than coarse slag, which has more

200

strong adsorbing ability. Fine slag were generated after high temperature black water flash and

201

subsequent processing, which had a more complete adsorption conversion between air, liquid

202

and solid phases, would have a higher concentration of PAHs than coarse slag.

203

3.3 Emission characteristics of PCDD/Fs

204

PCDD/Fs were detected in the gas samples under the test condition. the TEQ concentration

205

were shown in Figure 6 which calculated with the TEFs recommended by WHO. It was shown

206

that in the high temperature black water flash steam, desulfurization flash steam and

ACS Paragon Plus Environment

Page 10 of 25

Page 11 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

207

decarburization exhaust gas, the concentration of PCDD/Fs under the co-processing condition

208

was rather low, while in the methanol membrane separation exhaust gas it was much higher. The

209

cause was PCDD/Fs are more likely to form in the membrane separation process under the low

210

temperature condition.

211

PCDD/Fs concentration in fine slag and water under the two conditions was shown in

212

Figure 7. Analysis results showed the concentration of PCDD/Fs under the co-processing

213

condition was nearly to the blank condition or even lower. The concentration of PCDD/Fs in the

214

fine slag and in the water are rather low, only 0.001µg/kg and 0.01ng/L respectively.

215

3.4 Emission characteristics of VOCs

216

Table 2 showed the VOCs concentration in gas samples, which were classified to

217

halogenated hydrocarbon,benzene series and halogenated aromatics. The concentration of VOCs

218

has no increase with Co-processing 15% CLR. The concentrations of VOCs are very low under

219

both conditions while VOCs were not detected or below the detection limits in the liquid and

220

solid samples.

221

3.5 Environmental risks of the organic pollutants emission process

222 223

The BaPeq and ΣBaPeq of PAHs are calculated by the PAHs TEF,32 and toxicity equivalent concentration of PAHs in all samples were showed in Table 3.

224

After co-processing 15% CLR, the concentration of PAHs in high temperature black water

225

flash steam increased significantly. And the ΣBaPeq of PAHs is 0.0106µg TEQ/m3, twice than

226

that under blank condition, which exceeded the limited value 0.01µg TEQ/m3 in the Integrated

227

emission standard of air pollutants in China and the Council Directive 2004/107/EC of the

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

228

European Parliament and of the Council (relating to arsenic, cadmium, mercury, nickel and

229

polycyclic aromatic hydrocarbons in ambient air),33,34 has certain environmental risks. The risk

230

of PAHs can be reduced by adding exhaust gas treatment facilities such as torch system to burn

231

the gas or reduce the adding ratio of CLR.

232

Under the two conditions, the ΣBaPeq of desulfurization flash steam, decarburization

233

exhaust gas and methanol membrane separation exhaust gas are far below the limited value

234

0.01µg TEQ/m3 in the Integrated emission standard of air pollutants, so the co-processing

235

process didn’t increase the PAHs emission environmental risks in these exhaust gases.

236

The concentration of PAHs in the water increased after co-processing 15% CLR, however

237

the ΣBaPeq is only 0.00015µg TEQ/L, far below the limited value 0.03µg TEQ/L in the

238

integrated pollutant discharge standard in China and the limited value 0.1ng TEQ/L(calculated

239

by the PAHs TEF) in America.35,36 The environmental risks of PAHs in the water was acceptable.

240

The water can be reused to make coal-water slurry, quench in the vaporizer, or discharged after

241

disposed.

242

The ΣBaPeq of the coarse slag of gasifier and fine slag of the black water disposal after

243

co-processing 15% CLR is 2.0235µg TEQ/kg and 5.2169µg TEQ/kg respectively, which

244

increased significantly. At present, there is no relevant standard for the content of PAHs in solid

245

waste in China. In Canada, the soil quality standard37 was set for the protection of environmental

246

and human health, taking account of the risk of exposure of people under different use of the soil

247

such as agriculture, residence, commerce and agriculture. The limitation of ΣBaPeq of the

248

agriculture soil in that standard was 0.10 mg TEQ/kg, which was the most strict in that standard.

ACS Paragon Plus Environment

Page 12 of 25

Page 13 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

249

In this study the concentration of PAHs in the coarse slag of gas furnace and fine slag of the

250

black water disposal increased after co-processing CLR, whereas the total toxicity concentration

251

is far less than 0.10mg TEQ/kg. So the emission discharge risk of PAHs of the coarse slag of gas

252

furnace and fine slag of the black water disposal during the co-processing process is in the

253

acceptable rang.

254

The concentration of PCDD/Fs in liquid and solid samples and most gas samples are rather

255

low both under blank condition and test condition and have low environmental risks. While

256

under the test condition, the concentration of PCDD/Fs in methanol membrane separation

257

exhaust gas is 0.14ng TEQ/m3 (Figure 6). Now there is no proprietary standard for the limitation

258

of PCDD/Fs concentration in flue gas in co-processing of solid wastes in coal-water slurry

259

gasifier, so according to the Standard for pollution control on the municipal solid waste

260

incineration38 which is the most strict standard with the limit value of 0.1ng TEQ/m3 for

261

PCDD/Fs emission in China, in America and EU the limited value is 0.4ng TEQ/m3 and 0.1ng

262

TEQ/m3 respectively, there are certain risks and the risk of PCDD/Fs in methanol membrane

263

separation exhaust gas can also be reduced by adding exhaust gas treatment facilities such as

264

torch system to burn the gas or reduce the adding ratio of CLR.

265

The concentration of VOCs in gas emission were far below the blank condition under test

266

condition, in the liquid emission and solid waste were mostly not detected or below the detection

267

limits, so VOCs emission in the co-processing process has low environmental risk.

268

4 Conclusions

269

During the co-processing of 15% CLR in Texaco coal-water slurry gasifier process, there

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 25

270

had little impact on the pressure and syngas output of the gasifier, but made an increase of 5-11℃

271

of the temperature and promoted the formation of H2 and CO. The concentration of PAHs in part

272

of the gas emission and liquid emission increased a little in the co-processing process, but the

273

toxicity equivalent concentration was still far lower than the standard limitation, has low

274

environmental risk. The concentration of PAHs in solid wastes increased significantly in the

275

co-processing process, but the total toxicity equivalent concentration was also low, the

276

environmental risk was in the acceptable range. The emission of PCDD/Fs and VOCs during the

277

co-processing process has low environmental risk. Organic matters were relatively fully

278

degraded during co-processing of CLR in Texaco coal-water slurry gasifier, which would be a

279

new way to dispose certain kinds of solid waste in practice.

280 281

Author Information

282

Corresponding Author

283

*Phone: +86-10-84915182; fax: +86-10-84913903; e-mail: [email protected]; address: Research

284

Institute of Soil and Solid Waste Management, Chinese Research Academy of Environmental

285

Sciences, No.8, Dayangfang, Anwai, Chaoyang district, Beijing 100012, China.

286

Notes

287

The authors declare no competing financial interest.

288 289

Acknowledgements

290

This research supported by the State Key Laboratory of Environmental Criteria and Risk

ACS Paragon Plus Environment

Page 15 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

291

Energy & Fuels

Assessment, Chinese Research Academy of Environmental Sciences.

292 293

References:

294

(1)

295 296 297 298

Menzie C.A.; Potocki B.B.; Santodonato J. Exposure to carcinogenic PAHs in the

environment. Environ. Sci. Technol. 1992, 26(7), 1278-1284. (2)

Thorsen, W.A.; Cope, W.G.; Shea, D. Bioavailability of PAHs: effects of soot carbon

and PAH source. Environ. Sci. Technol. 2004, 38(7),2029-2037. (3)

Yan, J.; Wang, L.; Fu, P.; Yu, H. Photomutagenicity of 16 polycyclic aromatic

299

hydrocarbons from the US EPA priority pollutant list. Mutation Res./Gene. Toxicol. &

300

Environ. Mutagene. 2004,557(1),99-108.

301

(4)

Abad,

E.;

Martinez,

K.;

Caixach,

J.;

Rivera,

J.

Polychlorinated

302

dibenzo-p-polychlorinated diben-zofuran releases into the atmosphere from the use of

303

secondary fuels in cement kilns during clinker formation. Environ. Sci. Technol.

304

2004,38,4734–8.

305

(5)

Yan, D.; Peng, Z.; Karstensen, K.H.; Ding, Q.; Wang, K.X.; Wang, Z.G. Destruction of

306

DDT wastes in two preheater/precalciner cement kilns in China. Sci. Total Environ. 2014, s

307

476–477,250-257.

308 309 310 311

(6)

UNEP. Stockholm Convention on persistent organic pollutants: United Nations

Environmental Programme. http://chm.pops.int/Convention/ConventionText/,2001. (7)

Kim, Y.M.; Stuart, H.A.; Harrison, R.M. Concentrations and Sources of VOCs in Urban

Domestic and Public Microenvironments. Environ. Sci. Technol. 2001, 35(6),997-1004.

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

312

(8)

Xu, L.; Tang, M.C.; Duan, L.; Liu, B.L.; Ma, X.X.; Zhang, Y.L.; Argyle, M.D.; Fan,

313

M.H. Pyrolysis characteristics and kinetics of residue from China Shenhua industrial direct

314

coal liquefaction plant. Thermochimica Acta. 2014, 589(10),1-10.

315

(9)

Dong, Z.; Yan, D.; He, J.; Luo, L.; Huang, Z. Combustion properties and benzene

316

compound emission characteristics of coal liquefaction residual co-combustion. Res. of

317

Environ. Sci. 2015,28( 8),1253- 1259. (In Chinese)

318

(10) Fang, L. Numerical simulation and experimental study on combustion charateristics of

319

Shenhua coal liquefaction residual and liquefaction residual CWS. Master Dissertation,

320

Zhejiang University, Hangzhou, 2006. (In Chinese).

321 322 323 324 325 326 327 328

(11) Liu, X.; Zhou, Z.; Hu, Q.; Dai, Z.; Wang, F. Experimental study on co-gasification of coal liquefaction residue and petroleum coke. Energy & Fuels, 2011, 25(8),3377-3381. (12) Hites, R. A. Polybrominated diphenyl ethers in the environment and in people: A meta-analysis of concentrations. Environ. Sci. Technol. 2004, 38, 945−956. (13) Child, C.A.; Robin, A.M. Gasification of residual materails from coal liquefaction. USERDA, 1977. (14) Robin, A.M. Gasification of coal liquefaction residues from the Wilsonville SRC pilot plant using the Texaco coal gasification process. USERDA, 1984.

329

(15) Huang, Q.; Yang, Y.; Wang, Q. Potential for Serious Environmental Threats from

330

Uncontrolled Co-processing of Wastes in Cement Kilns. Environ. Sci. Technol. 2012,

331

46(24),13031-2.

332

(16) Yan, D.; Peng, Z.; Ding, Q.; Karstensen, K.H.; Engelsen, C.J.; Li, L.; Ren, Y.; Jiang, C.

ACS Paragon Plus Environment

Page 16 of 25

Page 17 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

333

Distribution of Hg, As and Se in material and flue gas streams from preheater-precalciner

334

cement kilns and vertical shaft cement kilns in China. J. of the Air & Waste Manage.

335

Association. 2015, 65(8),1002-1010.

336

(17) Li, X.; Li, L.; Cong, J.; Yan, D.; Jiang, X.; Wang, Q. Research on condensation and

337

adsorption kinetics of Pb and Cd at low temperatures during co-processing of solid wastes in

338

blast furnaces. Res. of Environ. Sci. 2016, 29(11),1659-1664. (In Chinese).

339

(18) Li, X.; Li, L.; Huang Z.; Yan, D.; Yu, H.; Wang, N. Emission characteristics of

340

polycyclic aromatic hydrocarbons during co-processing of coal liquefaction residue in

341

Texaco coal-water slurry gasifier. China Environ. Sci. 2017, 37(10), 3845-3852. (In

342

Chinese).

343 344

(19) Guo, Q.; Gong, Y.; Xu, J.; Yu, G.; Wang, F. Particulate matter properties in bench-scale entrained-flow coal water slurry gasifier. Power Technol. 2014, 254(2), 125-130.

345

(20) Gong, X.; Lu, W.; Guo X.; Dai, Z.; Liang, Q.; Liu, H.; Zhang, H.; Guo, B. Pilot-scale

346

comparison investigation of different entrained-flow gasification technologies and prediction

347

on industrial-scale gasification performance. Fuel 2014, 129(7), 37-44.

348

(21)

Wu, Y.; Zhang, J.; Smith, P.J.; Zhang, H.; Reid, C.; Lv, J.; Yue, G. Three-dimension

349

simulation for an entrained flow coal slurry gasifier. Energy & Fuels 2010, 24(2),

350

1156-1163.

351 352 353

(22) Qian, F.; Kong, X.; Cheng, H.; Du, W.; Zhong, W. Development of a kinetic model for industrial entrained flow coal gasifier. Ind. Eng. Chem. Res. 2013,52(5), 1819-1828. (23) Choi, Y.C.; Li, X.Y.; Park, T.J.; Kim, J.H.; Lee, J.G. Numerical study on the coal

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

354 355 356

gasification characteristics in an entrained flow coal gasifier. Fuel 2001,80(15), 2193-2201. (24) Al-Salem, S.M.; Lettieri, P.; Baeyens, J. Recycling and recovery routes of plastic solid waste (PSW): a review. Waste Manage. 2009,29(10),2625-2643.

357

(25) Du, Y.; Jiang, X.; Ma, X.; Tang, L.; Wang, M.; Lv, G.; Jin, Y.; Wang, F.; Chi, Y.; Yan, J.

358

Cogasification of biofermenting residue in a coal-water slurry gasifier. Energy & Fuels

359

2014,28(3),2054-2058.

360

(26) Liu, G.; Zhan, J.; Zheng, M.; Li, L.; Li, C.; Jiang, X.; Wang, M.; Zhao, Y.; Jin, R. Field

361

pilot study on emissions, formations and distributions of PCDD/Fs from cement kiln

362

co-processing fly ash from municipal solid waste incinerations. J. of Hazard. Mater. 2015,

363

299,471-478.

364

(27) Bae, J.S.; Lee, D.W.; Park, S.J.; Lee, Y.J.; Hong, J.C.; Ra, H.W.; Han, C; Choi, Y.C.

365

High pressure gasification of coal water ethanol slurry in an entrained flow gasifier for

366

bioethanol application. Energy & Fuels. 2012, 140(1), 451–460.

367

(28) Van den Berg, M., Birnbaum, L.S., Denison, M., De Vito, M., Farland, W., Feeley, M.,

368

Fiedler, H., Hakansson, H., Hanberg, A., Haws, L., 2006, The 2005 World Health

369

Orgnization reevaluation of human and mammalian toxic equivalency fators for dioxins and

370

dioxin-like compounds, Toxicol. Sci. 93, 223-241.

371 372 373 374

(29) Pradhan, V.R.; Tierney J.W.; Wender, I.; Huffman, G.P. Catalysis in direct coal liquefaction by sulfated metal oxides. Energy & Fuels 1991, 5(3), 497-507. (30) Larson, E.D.; Ren, D. Synthetic fuel production by indirect coal liquefaction. Energy for Sustain. Develop. 2003, 7(4), 79-102.

ACS Paragon Plus Environment

Page 18 of 25

Page 19 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

375 376 377 378 379 380

Energy & Fuels

(31) Mcenaney, B.; Masters, K.J. Assessment of adsorption microporous carbons. Thermochimica Acta.1984,82(1), 81-102. (32) Nisbet, I.C.; Lagoy, P.K. Toxic equivalency factors (TEFs) for polycyclic aromatic hydrocarbons (PAHs). Regulatory Toxicol. & Pharmacol. 1992, 16(3), 290. (33) Integrated

emission

standard

of

air

pollutants;

GB16297-1996,

1996;

http://www.mep.gov.cn/image20010518/5302.pdf.

381

(34) EC, 26 January 2005. Council Directive 2004/107/EC of the European Parliament and

382

of the Council (relating to arsenic, cadmium, mercury, nickel and polycyclic aromatic

383

hydrocarbons in ambient air). Official Journal of the European Union L 23, 3-16.

384

(35) Integrated

wastewater

discharge

standard;

GB8978-1996,

1996;

385

http://kjs.mep.gov.cn/hjbhbz/bzwb/shjbh/swrwpfbz/199801/W020061027521858212955.pdf

386

.

387 388 389

(36) USEPA, 1999. National recommendation water quality criteria-correction. Official water 4304, EPA 822-Z-99-001. (37) Canada's environment committee. Canadian soil quality guidelines for the protection of

390

environmental

and

human

health;

CCME,2007;

391

https://en.wikipedia.org/wiki/Canadian_Council_of_Ministers_of_the_Environment.

392

(38) Standard for pollution control on the municipal solid waste incineration; GB

393

18485-2014,2014;http://kjs.mep.gov.cn/hjbhbz/bzwb/gthw/gtfwwrkzbz/201405/W02014053

394

0531389708182.pdf.

395

ACS Paragon Plus Environment

Energy & Fuels

396

397 398

Figure 1. Methanol production process diagram by Texaco coal-water slurry gasifier

399 400

45 PAHs in CLR

PAHs in coal

35

300

30 250 25 200 20 150 15 100

10

50

5 0

0 Nap Ace Acy

400 401

Flu

Phe

Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahABghiP PAHs

Figure 2. Concentration of 16 kinds of PAHs in reactive materials

402

ACS Paragon Plus Environment

PAHs concentration in coal(mg/kg)

40

350 PAHs concentration in CLR(mg/kg)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 25

Page 21 of 25

5

Nap Ace Acy Flu Phe Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahA BghiP

PAHs concentration(µg/m3)

4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 avrblkS1 avrS1 avrblkS2 avrS2 avrblkS3 avrS3 avrblkS4 avrS4 number of samples

403 404

Figure 3. PAHs concentration in gas emissions

405 40

Nap Ace Acy Flu Phe Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahA BghiP

35 PAHs concentration(ng/L)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

30 25 20 15 10 5 0 avrblkS5

406 407

avrS5 number of samples

Figure 4. PAHs concentration in liquid emissions

ACS Paragon Plus Environment

Energy & Fuels

4500

Nap Ace Acy Flu Phe Ant Flua Pyr BaA Chr BbF BkF BaP IcdP DahA BghiP

PAHs concentration(µg/kg)

4000 3500 3000 2500 2000 1500 1000 500 0 avrblkS6

408 409

avrS6 avrblkS7 number of samples

avrS7

Figure 5. PAHs concentration in solid emissions

410 0.16 PCDD/Fs concentration(ng TEQ/m3)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 25

0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 S1

S2

S3 number of samples

S4

411 412

Figure 6. PCDD/Fs concentration in gas emissions under test condition

413

ACS Paragon Plus Environment

2,3,7,8-T4CDD 1,2,3,7,8-P5CDD 1,2,3,4,7,8-H6CDD 1,2,3,6,7,8-H6CDD 1,2,3,7,8,9-H6CDD 1,2,3,4,6,7,8-H7CDD OCDD 2,3,7,8-T4CDF 1,2,3,7,8-P5CDF 2,3,4,7,8-P5CDF 1,2,3,4,7,8-H6CDF 1,2,3,6,7,8-H6CDF 1,2,3,7,8,9-H6CDF 2,3,4,6,7,8-H6CDF 1,2,3,4,6,7,8-H7CDF 1,2,3,4,7,8,9-H7CDF OCDF

0.0015

PCDD/Fs concentration(ng TEQ/L)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

PCDD/Fs concentration(µg TEQ/kg)

Page 23 of 25

a 0.001

0.0005

0 blkS5 S5 number of samples

417

2,3,7,8-T4CDD 1,2,3,7,8-P5CDD 1,2,3,4,7,8-H6CDD 1,2,3,6,7,8-H6CDD 1,2,3,7,8,9-H6CDD 1,2,3,4,6,7,8-H7CDD OCDD 2,3,7,8-T4CDF 1,2,3,7,8-P5CDF 2,3,4,7,8-P5CDF 1,2,3,4,7,8-H6CDF 1,2,3,6,7,8-H6CDF 1,2,3,7,8,9-H6CDF 2,3,4,6,7,8-H6CDF 1,2,3,4,6,7,8-H7CDF 1,2,3,4,7,8,9-H7CDF OCDF

b 0.01

0.005

0 blkS7 S7 number of samples

414 415 416

0.015

Figure 7. PCDD/Fs concentration in solid and liquid emissions

Table 1. Field test samples

Number of Samples

Sampling points

Frequency ①

samples ②

S1 High temperature black water flash steam

Flashing tower exhaust port

3

S1test1-3

S2Desulfurization flash steam

Desulfurizing tower exhaust port

5

S2test1-5

S3Decarburization exhaust gas

Decarburization tower exhaust port

5

S3test1-5

S4Methanol membrane separation exhaust gas

Rectifying tower exhaust port

5

S4test1-5

S5Water

Delivery tank

2

S5test1-2

S6Coarse slag

Slag-dripping port

2

S6test1-2

S7Fine slag

Pressure filter port

2

S7test1-2

418

①:blk means samples under blank condition, avr means average value of each kind of sample

419

②:Sampling points in Figure1

420 421

Table 2. VOCs concentration in gas samples

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Gas samples Halogenated hydrocarbon (mg/m3)

Page 24 of 25

Blank condition

Test condition

2.8±1.5

1.4±1.6

15.9±1.1

16.9±0.7

0.004

ND

8.4±4.2

11.3±5.4

6.7±0.82

8.1±1.0

0.004

N.D.

1.6±0.39

0.25±0.083

1.8±0.15

2.1±0.12

0.0082±0.0082

N.D.

N.D.

N.D.

0.85±0.16

0.82±0.064

N.D.

0.004

High temperature black water flash Benzene series (mg/m3) steam Halogenated aromatics (mg/m3) Halogenated hydrocarbon (mg/m3) Benzene series(mg/m3)

Desulfurization flash steam

Halogenated aromatics (mg/m3) Halogenated hydrocarbon (mg/m3) Benzene series(mg/m3)

Decarburization exhaust gas

Halogenated aromatics (mg/m3) Halogenated hydrocarbon (mg/m3) Methanol membrane separation Benzene series(mg/m3) exhaust gas Halogenated aromatics (mg/m3)

422 423

Table 3. Toxicity equivalent concentration of PAHs in all samples Samples

Blank condtion ΣBaPeq

Test condition ΣBaPeq

High temperature black water flash steam S1(µg/m3)

0.0045±0.0008

0.0106±0.0039

Desulfurization flash steam S2(µg/m3)

0.0100±0.0049

0.0091±0.0061

Decarburization exhaust gas S3(µg/m3)

0.0081±0.0079

0.0034±0.0011

Methanol membrane separation exhaust gas S4(µg/m3)

0.0044±0.0027

0.0046±0.0016

0.1460±0.0063

0.1676±0.0114

1.3850±0.1339

2.0235±0.0695

Water S5(ng/L)

Coarse slag S6(µg/kg)

ACS Paragon Plus Environment

Page 25 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Fine slag S7(µg/kg)

3.3602±0.1346

424 425

ACS Paragon Plus Environment

5.2169±0.4748