Subscriber access provided by UNIVERSITY OF TOLEDO LIBRARIES
Combustion
Experimental research on flameless combustion with coal preheating technology Wen Liu, Ziqu Ouyang, Xiaoyang Cao, and Yongjie Na Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.8b00719 • Publication Date (Web): 22 May 2018 Downloaded from http://pubs.acs.org on May 22, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
2
Experimental research on flameless combustion with coal preheating technology
3
Wen Liu†,‡, Ziqu Ouyang†,*, Xiaoyang Cao†, Yongjie Na†,‡
4
†
5
100190, China
6
‡
7
ABSTRACT: As a novel combustion technology, flameless combustion is attractive to
8
achieve high efficient and low NOX utilization of fuels. In the paper, a new method to
9
realize flameless combustion of pulverized coal based on coal preheating technology
10
was adopted. Experimental research on flameless combustion was implemented with
11
pulverized coal in a 30 kW coal preheating and combustion test rig. In the study, coal
12
preheated characteristics, combustion behavior and formation mechanism of NOX are
13
discussed. The results show that the temperature of pulverized coal can be preheated
14
up to above 850 oC, and most of the volatile are released during preheating process.
15
Only 33.90% of the fixed carbon in pulverized coal is converted into coal gas and
16
most remains in the high temperature coal char, and 91.14% of the fuel-N released
17
from pulverized coal is converted to N2. Stable flameless combustion can be achieved
18
with preheated fuels in the down-fired combustor, and no obvious flame front can be
1
Institute of Engineering Thermophysics, Chinese Academy of Science, Beijing
University of Chinese Academy of Sciences, Beijing 100049, China
1
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
observed through the looking-fire-windows, and the luminosity is uniform inside the
2
down-fired combustor. The temperature profile in combustion zone is uniform with
3
normalized temperature fluctuation less than 10%. NOX is generated near the fuel
4
nozzle and then reduced in the main combustion zone, and the NOX emission is 67
5
mg/Nm3 (6% O2). The formation of NOX is inhibited by rational air distribution, and
6
the combustion efficiency reaches up to 96.4%.
7
KEYWORDS: coal preheating; flameless combustion; NOX emission
8
1. INTRODUCTION
9
Flameless combustion is a novel combustion mode different from conventional
10
combustion, for it is characterized by no visible flame front and uniform temperature
11
profiles1, 2. Since 1990s, flameless combustion has demonstrated its great potential to
12
control NOX, therefore it is considered as one of the most promising technique for
13
de-NOX combustion and draws more and more attention. Flameless combustion can
14
be achieved by preheating air up to 1000 oC and the reactants are diluted in a
15
low-oxygen atmosphere, therefore it is also called high temperature air combustion
16
(HTAC)3-5 or moderate & intense low oxygen dilution (MILD)6-9. Colorless
17
distributed combustion10-12 (CDC) is another name of flameless combustion for its
18
flame front is invisible.
19
Within two decades, flameless combustion technique has been rapidly developed 2
ACS Paragon Plus Environment
Page 2 of 32
Page 3 of 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
1
with gaseous fuel, and industrial application has been achieved. With the development
2
of flameless combustion, solid fuel flameless combustion is also gaining ever
3
increasing attention. The initial experimental investigations on coal flameless
4
combustion were launched in the International Flame Research Foundation (IFRF)
5
with exhaust gas from the gas turbine13. Since then, more and more studies on solid
6
fuel flameless combustion have been implemented. Stadler14 studied the impact of
7
gasification on the prediction of NO formation in coal flameless combustion, and
8
verified that the prediction of NO emission was up to 40% lower with considering
9
gasification than without. Vascellari15 studied the influence of turbulence-chemistry
10
interaction on coal flameless combustion and obtained more accurate simulation
11
results. Saha16, 17 carried out many experimental researches on Victorian brown coal in
12
MILD combustion. Dally7 successfully achieved MILD combustion with sawdust.
13
Xing18 achieved flameless combustion of pulverized coal with normal temperature air,
14
and concluded that preheating combustion air is not always necessary, and the same
15
conclusion was also gained by Dally7. Flameless combustion for solid fuels was
16
mainly focused on coals with high volatile content in the past decades and by the
17
means of high temperature air combustion or a high speed jet. But nowadays
18
nonflammable fuels like anthracite and petroleum coke have also been studied to
19
verify the stability and broaden the adaptation range of flameless combustion. In
20
Suda’s research19, anthracite was used to demonstrate the effect of coal type on the
21
combustion behavior in high temperature air combustion. MILD combustion on 3
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
Bowen black coal with either CO2 or N2 as the carrier gas was studied experimentally
2
and numerically without any external air preheating in Saha’s researches20, 21. Zhang
3
Hai5 developed a novel PRP (primary air enrichment and preheating) burner and an
4
internal hot gas recirculation could be formed inside the burner chamber, thus the
5
primary air, along with fuel was preheated in the chamber. Fuel preheating might be
6
an effective method to establish flameless combustion on solid fuels. Pulverized coal
7
preheating technique was deeply studied at the All-Russian Thermal Engineering
8
Institute and testified to be effective to control NOX22, 23. But it required an external
9
heat source (a natural gas-fired PC burner) to preheat pulverized coal, and the process
10
was complicated and preheating temperature was hard to control.
11
A novel coal preheating method based on a circulating fluidized bed (CFB) was
12
proposed by the Institute of Engineering Thermophysics, Chinese Academy of
13
Sciences, and many experiments have been implemented24-27. The results showed that
14
pulverized coal was preheated up to above 800 oC without external heat input, and
15
NOX emission was as low as 60 mg/Nm3 (@6 vol% O2)27. The aim of this paper is to
16
achieve flameless combustion of pulverized coal by applying coal preheating
17
technique with a CFB, and to study the preheating and combustion behavior and NOX
18
emissions characteristics.
19
2. Experiment
20
2.1 Test rig. 4
ACS Paragon Plus Environment
Page 4 of 32
Page 5 of 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
1 2
The coal preheating and combustion system is shown in Figure 1. The system consists of a preheating burner, a down-fire combustor and some other auxiliaries.
Secondary air
3
Looking-fire window
2
Tertiary air 4
Primary air
5
6
8
1 7
3 4
1 air compressor, 2 coal feeder, 3 preheating burner, 4 down-fired combustor, 5 water cooler, 6 bag
5
filter, 7 water tank, 8 chimney.
6
Figure1. Schematic diagram of the test rig
7
The preheating burner consists of a riser, a cyclone separator and a back-feeder.
8
The riser is 90 mm in inner diameter and 1500 mm in height. The primary air, which
9
accounts of about 30% of the air required for complete combustion, is supplied into
10
the preheating burner from its bottom. Pulverized coal is stored in a stock bin, and is
11
fed into the preheating burner by a screw feeder. Pulverized coal is heated up to above
12
850 oC by heat released from its partial combustion, and then enters into the
13
down-fired combustor for complete combustion. Since the excess air coefficient is
14
very low in the preheating burner, coal gasification reaction should be taken into
15
account. The gas outflows the preheating burner is mainly composed by N2, CO, CO2, 5
ACS Paragon Plus Environment
Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
H2 and CH4, which can be named as coal gas. The preheated fuel contains high
2
temperature coal char and coal gas.
3
The down-fired combustor is 300 mm in inner diameter and 3500 mm in height
4
with a preheated fuel nozzle and the secondary air nozzles on the top. The preheated
5
fuel nozzle is 36 mm in inner diameter and located at the center, and the secondary air
6
nozzles are 7 mm in inner diameter and located on both sides of the preheated fuel
7
nozzle. The schematic diagram of the nozzles is shown in Figure 2. Air-staged method
8
is used in the research to reduce NOX emission. The tertiary air is injected into the
9
down-fired combustor at a position of 500 mm, 1000 mm and 1500 mm below the
10
secondary air nozzle, respectively. To observe the flame, six looking-fire-windows are
11
set, and located at the position of 80 mm, 250 mm, 600 mm, 900 mm, 1200 mm and
12
1600 mm below the preheated fuel nozzle. The top two are 15 mm×150 mm in square
13
shape, and the others are round with a diameter of 63 mm. Compressed air is used to
14
sweep the fouling on the quartz glass. Since the fouling speed is so slow that
15
compressed air is not frequently used, and the flow is small enough, the effect of
16
compressed air to flame is not taken into consideration.
6
ACS Paragon Plus Environment
Page 6 of 32
Page 7 of 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
Preheated fuel nozzle Secondary air nozzle
1 2
3
Figure 2. The nozzle structure on the top of down-fired combustor
2.2 Sampling point.
4
Five K-type thermocouples are set in the preheating burner at the position of 100
5
mm, 500 mm and 1450 mm from the bottom of riser, one is at the back-feeder and one
6
is at the outlet of the preheating burner; Ten S-type thermocouple are set at the
7
position of 100 mm, 250 mm, 400 mm, 600 mm, 800 mm, 1200 mm, 1600 mm, 2100
8
mm, 2600 mm and 3200 mm down from the preheated fuel nozzle along the
9
centerline of the down-fired combustor. In Saha’s research16, corrected combustion
10
temperature was calculated considering the thermal radiation on temperature
11
measurement and the results showed that the maximum radiation correction is 4.5%
12
and most correction is