Subscriber access provided by GEBZE YUKSEK TEKNOLOJI ENSTITUSU
Article
The fluidized capacitive bio-anode as a novel reactor concept for the microbial fuel cell Alexandra Deeke, Tom H.J.A. Sleutels, Tim F.W. Donkers, Hubertus V.M. Hamelers, Cees J.N. Buisman, and Annemiek Ter Heijne Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/es503063n • Publication Date (Web): 16 Dec 2014 Downloaded from http://pubs.acs.org on December 23, 2014
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 21
Environmental Science & Technology
120x146mm (150 x 150 DPI)
ACS Paragon Plus Environment
Environmental Science & Technology
1
The fluidized capacitive bio-anode as a novel reactor concept for
2
the microbial fuel cell
3 4
Alexandra Deeke a, b, Tom H. J. A. Sleutels b, Tim F.W. Donkersa,b, Hubertus V. M. Hamelers
5
b
, Cees J. N. Buisman a, b, Annemiek Ter Heijne a,*
6
a
Sub-Department of Environmental Technology, Wageningen University, Bornse Weilanden
7
9, P.O. Box 8129, 6708 WG Wageningen, The Netherlands
8
b
9
8900 CC Leeuwarden, The Netherlands
Wetsus, Centre of Excellence for Sustainable Water Technology, Agora 1, P.O. Box 1113,
10 11
* Corresponding author. Phone: +31 317 483447:
[email protected] 12
ACS Paragon Plus Environment
Page 2 of 21
Page 3 of 21
Environmental Science & Technology
13
Abstract
14
The use of granular electrodes in Microbial Fuel Cells (MFCs) is attractive because granules
15
provide a cost-effective way to create a high electrode surface area, which is essential to
16
achieve high current and power densities. Here, we show a novel reactor design based on
17
capacitive granules: the fluidized capacitive bio-anode. Activated carbon (AC) granules are
18
colonized by electrochemically-active microorganisms, which extract electrons from acetate
19
and store the electrons in the granule. Electricity is harvested from the AC granules in an
20
external discharge cell. We show a proof-of-principle of the fluidized capacitive system with a
21
total anode volume of 2 L. After a start-up period of 100 days, the current increased from
22
0.56 A/m2 with 100 g AC granules, to 0.99 A/m2 with 150 g AC granules, to 1.3 A/m2 with 200
23
g AC granules. Contact between moving AC granules and current collector was confirmed in
24
a control experiment without biofilm. Contribution of an electro-active biofilm to the current
25
density with recirculation of AC granules was limited. SEM images confirmed that a biofilm
26
was present on the AC granules after operation in the fluidized capacitive system. Although
27
current densities reported here need further improvement, the high surface area of the AC
28
granules in combination with external discharge offers new and promising opportunities for
29
scaling up MFCs.
30
ACS Paragon Plus Environment
Environmental Science & Technology
Page 4 of 21
31
1. Introduction
32
With the increase in world population and the resulting increase in energy consumption,
33
together with the need to keep our planet healthy, the search is on for renewable energy
34
production technologies. One of these technologies is the Microbial Fuel Cell (MFC), in which
35
electrochemically-active microorganisms convert the chemical energy in biodegradable
36
organics into electrical energy, so that electricity is directly recovered from the decomposition
37
of organics in wastewater. In the past decade, many crucial elements in the MFC have been
38
studied, from electrode materials
39
communities 8, electron transfer mechanisms
40
types of wastewater 14–16, alternative cathode reactions 17–19, and scaling up 20,21.
41
Two important parameters for operation of Microbial Fuel Cells (MFCs) are the current
42
density and the power output. The current density is directly related to the conversion rate of
43
organic matter, and thus determines the rate at which wastewater is cleaned. The power
44
density expresses the rate at which energy is recovered from wastewater, and determines
45
the efficiency of the conversion from organics to electricity. During the past decade, the
46
research on MFCs has intensified considerably, and the highest reported power densities
47
increased from 0.01 W/m² in 2002
48
time, we see in the past few years, reported power densities seem to have stagnated around
49
2-3 W/m2. Typical power densities, when normalized to volume, range between 1 and 200
50
W/m3
51
technologies: anaerobic digestion, in which an energy recovery of 1,000 W/m3 can be
52
achieved 25,28.
25–27
1
, to membranes
22,23
2–4
, reactor design
9,10
, mass transport
up to 3.1 W/m2 in 2009
5–7
11
, microbial
, start-up strategies
24
12,13
,
(Figure 1). At the same
. This power density is still too low to be competitive with one of the competing
ACS Paragon Plus Environment
Page 5 of 21
Environmental Science & Technology
53 54
Figure 1 Development of reported power densities in literature over the past decade.
55 56
Although these power densities have been demonstrated at lab-scale, the question is how
57
and if these systems will show the same performance when operated at a larger scale. In a
58
recent review
59
(reactors larger than 1L) are discussed. The main limitations in these scaled-up systems are
60
related to a high internal resistance, caused by electrode spacing or limited conductivity of
61
the electrodes, especially when granular materials are used in a tubular design.
62
Granular materials are attractive because they provide a cost-effective way to create a high
63
electrode surface area, which is essential to achieve high current and power densities.
64
Granular materials, usually in the form of graphite or activated carbon, have mostly been
65
used in a fixed bed reactor, in which the electric current was harvested via a current
66
collector, which is a graphite rod
67
was demonstrated that electricity could be generated in an anaerobic fluidized bed MFC,
68
where the active carbon particles could flow freely in the anaerobic column so that better
69
mixing could be achieved
29
, the tubular and flat plate designs that have been tested on larger scale
30
or a Ti-wire or mesh
31
. To enhance mass transport, it
32
. In this setup, the electricity was also harvested in-situ via a
ACS Paragon Plus Environment
Environmental Science & Technology
70
graphite rod inserted in the column. Both granular activated carbon, and graphite granules
71
were tested, and it was shown that with the use of a mediator (neutral red), a power density
72
up to 1.1 W/m2 could be produced 32.
73
Another approach is to integrate capacitive materials in the bio-anode of an MFC33. When a
74
capacitive activated carbon layer was cast onto an electrode, it was shown that 53% more
75
charge could be recovered compared to a non-capacitive flat plate electrode. The thickness
76
of the capacitive layer was shown to affect the current and power density34. Recently, Liu et
77
al
78
that were charged by exoelectrogenic biofilms inside a 7 mL anode chamber and discharged
79
at a current collector integrated in the anode chamber. Mixing of the particles resulted in
80
improved performance compared to a fixed bed setup.
81
The objective of this study was to study a new reactor concept where electrons are stored
82
inside AC granules in a charging column, and the electricity is harvested in an external
83
electrochemical cell instead of in-situ in the anaerobic reactor. We tested this fluidized
84
capacitive system with a total anolyte volume of 2.1 L and we analyzed the performance of
85
this system in terms of current density, COD removal, and coulombic efficiency.
35
have shown that electricity could be harvested intermittently from capacitive particles
86 87
2. Materials and methods
88
2.1 System setup.
89
The principle of the fluidized capacitive system is shown in Figure 2.
ACS Paragon Plus Environment
Page 6 of 21
Page 7 of 21
Environmental Science & Technology
90 91 92 93 94 95 96
Figure 2: The setup of the fluidized capacitive system. In the charging reactor, electrochemically-active microorganisms attach to the activated carbon (AC) granules. While converting acetate to CO2 and protons, electrons are stored in the AC granules. Electricity is harvested in the discharge cell where the AC granules release their stored electrons to the current collector (anode). AC granules are recirculated through the system driven by a nitrogen gas flow.
97 98
The setup consisted of a charging column (2.08 L), made of glass, and a discharge cell
99
(0.022 L), made of Perspex, with a total anode volume of 2.1 L. Details of the reactor can be
100
found in Figure S1A in the Supporting Information. In the charging column, the AC granules
101
are transported upward by a flow of nitrogen gas. After the upward transport, the granules
ACS Paragon Plus Environment
Environmental Science & Technology
102
are transported through a glass tube and settle through the discharge cell. From the
103
discharge cell, the granules are transported through a glass tube to the charging reactor. The
104
discharge cell consisted of a current collector (anode) and a cathode, both flat graphite
105
plates (Müller & Rössner GmbH, Troisdorf, Germany) of 11 cm2 surface area (Figure S1B
106
Supporting Information). Both electrodes are separated by two plates with a flow channel,
107
similar to the ones used in Ter Heijne et al. (2008)
108
contact area of the electrodes of 11 cm2 and a thickness of 2 cm, resulting in 22 mL anode
109
and cathode compartment volume in the discharge cell. A cation exchange membrane
110
(Ralex, Mega, Straz pod Ralskem, Czech Republic) was used to separate anode and
111
cathode compartment. Total circulation volume of the cathode was 1.02 L, consisting of the
112
discharge cathode compartment of 22mL plus a storage vessel for the catholyte of 1L that
113
was located next to the discharge cell.
114
2.2 Electrode preparation and analysis. The anode granules consisted of activated carbon
115
(AC) granules (bulk density: 510 kg/m³, fraction 1620 of GAC 1240, Norit, Amersfoort, The
116
Netherlands). According to the specifications, the size of the majority of the granules was
117
between 0.84 and 1.18 mm, with less than 4% of the particles 1.70 mm. 100 g (dry weight) of the AC granules were soaked in tap-water prior
119
to inoculation. The granules were first placed in a flat plate cell and inoculated with effluent of
120
another MFC operated on acetate
121
used for the flat-plate cell was 500Ω. After 2 weeks, the flat-plate cell was opened and the
122
granules were transferred into the fluidized bed reactor. On day 130 and 180, an additional
123
50g of pre-inoculated granules were added from the flat plate cell to the fluidized bed reactor,
124
resulting in a final amount of 200g AC granules.
125
2.3 Operation and Measurements. The fluidized capacitive anode was continuously fed
126
with 5.2 mL/min of fresh medium and the anolyte and catholyte were recirculated at a rate of
127
500mL/min. The HRT of the medium in the anode compartment was 6.7 h. The influent to the
128
fluidized capacitive anode was a mixture of 10 mM sodium acetate with a 10 mM phosphate
37
36
, but smaller. The flow channel had a
to achieve biofilm growth on the granules. The load
ACS Paragon Plus Environment
Page 8 of 21
Page 9 of 21
Environmental Science & Technology
129
buffer solution at pH 7. Additionally, 10 mL/L of a macronutrient, 1 mL/L of a micronutrient
130
and 1 mL/L of a vitamin solution was supplied to the anolyte4. The catholyte (discharging cell)
131
consisted of a 10 mM ferricyanide solution. The charging column was constantly flushed with
132
nitrogen gas at a rate of 9 L/h from the bottom to the top to drive the upward transport of the
133
AC granules. The average granule recirculation rate was 45 s, meaning that it took each
134
granule in average 45s to pass one time through the reactor. The current collector was
135
constantly controlled at a potential of -0.300V vs. Ag/AgCl (+0.2V vs. NHE, Pro Sense,
136
Oosterhout, The Netherlands). This anode potential was chosen based on performance of
137
capacitive bio-anodes during charge-discharge experiments in an earlier study33. The anode
138
potential was controlled with a potentiostat (n-stat, Ivium Technologies, Eindhoven, The
139
Netherlands). The pH of the anolyte was constantly measured using a pH-electrode
140
(Liquisys, Endress + Hauser, Naarden, The Netherlands). Voltage and current were
141
constantly recorded.
142
Two types of control experiments were performed. The objective of the first experiment was
143
to study if electrons could be transferred between non-inoculated AC granules and the
144
current collector (anode). The objective of the second experiment was to study if a biofilm
145
could grow on the current collector (anode) when granules were recirculated.
146
To study electron transfer between non-inoculated AC granules and the current collector, we
147
studied the charge/discharge behavior of the fluidized bed system both without granules and
148
with 50g of non-inoculated granules in recirculation. The anolyte and catholyte were the
149
same as used during the rest of the experiment. The potential of anode current collector was
150
controlled in three steps: first two charging steps at an anode potential of -0.3 V vs Ag/AgCl
151
during 30 s and -0.5 V vs Ag/AgCl during 30 s, then one discharging step at an anode
152
potential of -0.1 V vs Ag/AgCl during 30 s. The anode potential of -0.3 V vs Ag/AgCl was
153
chosen in the first charging step to charge the particles at the same potential used
154
throughout the experiments; the second charging step was performed at more negative
155
anode potential (-0.5 V vs Ag/AgCl) to increase the driving force for charge transfer. The
ACS Paragon Plus Environment
Environmental Science & Technology
156
same procedure of two charging steps and one discharging step was repeated after addition
157
of 50 g AC granules to the anode compartment, to study if additional charge would be
158
transferred when the AC granules were recirculated.
159
To study the contribution of an electro-active biofilm on the current collector to the total
160
current produced by the discharge cell, we operated the fluidized bed system without
161
granules. The system was inoculated with effluent of another MFC operated on acetate and
162
the current collector (anode) of the discharge cell was controlled at -0.3 V vs Ag/AgCl. After a
163
stable current was reached, 50 g of AC granules were added to the system and recirculation
164
started. Current was continuously monitored. Finally, the current was monitored after
165
recirculation of AC granules was stopped.
166
2.4 Analyses and calculations.
167
During the first 112 days of operation the COD of the anode compartment was monitored in
168
the influent and in the effluent of the cell. From these measurements the COD-removal rate
169
and the coulombic efficiency were determined. The COD was measured using a standard
170
test kit (Nr 414, Hach Lange, Tiel, The Netherlands).
171
The specific surface area of the AC granules without biofilm was determined using BET-
172
Analysis as described in Deeke et al. (2012)
173
1989.4 ± 236.2 m²/g, which is a typical value for AC granules 38.
174
The current density was calculated from the produced current through; i = I/A in A/m², where
175
A is the projected surface area of the anode, cathode or membrane (0.0011 m2).
176
The COD removal of the fluidized bed anode was determined between day 55 and 112. The
177
COD removal efficiency (rCOD in %) was calculated according to:
࢘ࡻࡰ =
33
. The specific surface area was found to be
ሺࡻࡰ − ࡻࡰ࢛࢚ ሻ ࡻࡰ
ACS Paragon Plus Environment
Page 10 of 21
Page 11 of 21
Environmental Science & Technology
178
where CODin is the concentration of COD (mol/L) measured in the inflow of the fluidized bed
179
anode and CODout is the concentration of COD (mol/L) measured in the outflow of the
180
fluidized bed anode.
181
With the COD removal and the average current density (A/m²), the coulombic efficiency (CE)
182
was calculated according to:
= ܧܥ
ܯைଶ × ܫ ݊ × ܦܱܥ∆ × ܳ × ܨ
183
where MO2 is the molecular weight of oxygen (32 g/mol), I is the average current, n = 4 is the
184
number of electrons exchanged per mole of oxygen, F is the Faraday constant (96485
185
C/mol), Q is the volumetric influent rate (L/s) and ∆COD is the difference in COD between
186
the influent and the effluent (g/L).
187 188
3. Results and discussion
189 190
In this work, we studied a novel reactor system in which AC granules are used in a fluidized
191
reactor to store electrons derived from wastewater by electrochemically-active
192
microorganisms, and in which the electricity is harvested in an external discharge cell.
193 194
3.1 Increase in current production with increasing loading of AC particles
195
During the first 100 days after addition of 100g pre-inoculated AC granules in the system,
196
current density in the discharge cell (at -0.3 V vs Ag/AgCl) was around 0.17 A/m2. After 100
197
days, an increase in current density was observed to 0.56 A/m2. After addition of another 50
198
g AC granules, the current density first decreased but then gradually increased to 0.99 A/m2.
199
After addition of another 50 g AC granules, a further increase to 1.3 A/m2 was observed on
200
day 218. This increase in current density with increasing loading of pre-inoculated AC
201
granules indicates that the electrochemically-active microorganisms on the AC granules are
202
able to store electrons, and that these electrons can be harvested in the discharge cell.
ACS Paragon Plus Environment
Environmental Science & Technology
203 204 205 206 207
Figure 3 The development of the current density of the fluidized bed anode. The current density increased from 0.18 A/m² at day 96 to 1.3 A/m² at day 218. During the experimental period the AC granule loading was increased from 100g at the start, to 150 g on day 153, to 200 g on day 185.
208 209
To monitor the microbial activity during start-up of the fluidized capacitive anode, the COD
210
removal was measured and coulombic efficiency was determined between day 51 and 112.
211
From day 51 to day 105, the current density was stable around 0.17 A/m2, and thereafter an
212
exponential increase in current was observed to 0.56 A/m2. The COD removal efficiency
213
increased in time from 20-40% in the beginning, to 65-72% in the days that a sharp increase
214
in current density was found. The coulombic efficiency increased as well, from 7% on day 51
215
to 27 % on day 112. This reflects that the electrochemically-active microorganisms indeed
216
became more active during the last weeks before the increase in current was observed. Still,
217
large part of the substrate was not converted into electrons, indicating loss of substrate to
218
either biomass growth or methanogens.
219
3.2 Role of AC granules in current production (abiotic test)
ACS Paragon Plus Environment
Page 12 of 21
Page 13 of 21
Environmental Science & Technology
220
To study in more detail if the AC granules indeed contributed to transfer of electrons, we
221
tested, in an abiotic control if the granules made electrical contact with the current collector.
222
An abiotic charge-discharge experiment was performed in the system, on the current
223
collector alone and with 50 g AC granules using the standard anolyte medium, but without
224
inoculation. We tested two charging steps at -0.3 and -0.5 V vs Ag/AgCl, where electrons
225
where transferred from current collector to AC granules, followed by one discharging step at -
226
0.1 V vs Ag/AgCl, where electrons were transferred from AC granules to current collector.
227
The charging current is represented by a negative current; the discharging current is
228
represented by a positive current. The results are shown in Figure 4 and summarized in
229
Table 1. At -0.1 V vs Ag/AgCl, the current collector alone showed a small peak, after which
230
the current quickly dropped to almost zero. At -0.3 V vs Ag/AgCl, a similar trend was
231
observed but current stayed slightly higher. At -0.5 V vs Ag/AgCl, a discharge peak can be
232
seen where the electrons were transported from the charged AC granules to the current
233
collector. When repeating the test with 50 g AC granules, we see a similar pattern, but with a
234
considerable higher current density at each potential, indicating that the AC granules do
235
exchange electrons with the current collector. This effect was more pronounced for the
236
charging steps than for the discharging steps, which is also reflected in the total transferred
237
charge (Table 1). For the current collector alone, in the three cycles, 61-100 % of the
238
electrons that were transferred during charging, were recovered in the discharge step. For
239
the current collector with 50 g AC granules, the percentage of charge recovered in the
240
discharge step was lower, between 12 and 16%. These results shows that it is possible to
241
charge and discharge the AC granules on the current collector in this fluidized capacitive
242
system, although part of the electrons charged on the particles were not recovered in the
243
discharge step. It is at this point not clear why only part of the electrons were recovered
244
when using 50 g AC granules. Explanations could be that the discharge time is not
245
sufficiently long, that too few particles have been charged during the charging step, or that
246
the driving force for discharge (at -0.1 V vs Ag/AgCl) was too low. While the results show that
247
electron transfer between AC granules and current collector does occur, the results do not
ACS Paragon Plus Environment
Environmental Science & Technology
Page 14 of 21
248
show what the mechanism of charge storage in the actual MFC system is. Are the electrons
249
stored inside the AC granules, or can they also be stored in the biofilm
250
is stored, and how this influences the performance of a fluidized capacitive bioanode, is an
251
aspect that needs further study.
41
? Where the charge
2000 50 g AC granules
Current collector
Current (µΑ)
1000
0 -0.1
-1000
-0.1 -0.3
-0.3
-0.1
-0.3 -0.5
-0.5
-0.5
-2000 0
100
150
200
250
300
Time (s)
252 253 254 255 256
50
Figure 4 Charge-discharge behavior of the current collector and the current collector with 50 g AC granules. The current and stored charge with 50 g AC granules is higher than for the current collector alone, indicating that charge is transferred between current collector and AC granules.
257 258 259 260
Table 1 Overview of the transferred charge for the current collector alone and for the current collector with 50 g AC granules that are recirculated via the charging column, at different potentials
Transferred charge (mC) Potential (mV vs Ag/AgCl) -300 (charge step 1) -500 (charge step 2) Total charging -100 (discharge) % of charge recovered
Current collector Cycle 1 -0.43 -1.75 -2.18 2.29 105
50 g AC particles
ACS Paragon Plus Environment
-4.54 -7.94 -12.48 1.52 12
Page 15 of 21
Environmental Science & Technology
-300 (charge step 1) -500 (charge step 2) Total charging -100 (discharge) % of charge recovered -300 (charge step 1) -500 (charge step 2) Total charging -100 (discharge) % of charge recovered
Cycle 2 -1.05 -1.82 -2.87 1.76 61 Cycle 3 -1.01 -1.89 -2.90 2.17 75
-3.68 -6.99 -10.67 1.50 14 -3.73 -6.61 -10.34 1.72 17
261 262
3.3 Contribution of an electro-active biofilm on the current collector when non-inoculated AC
263
granules are recirculated
264
Figure 3 shows that an increase in particle loading resulted in an increase in current density.
265
It is possible, though, that part of the current was produced by electrochemically-active
266
microorganisms attached to the current collector (anode) of the discharge cell. To study the
267
possible contribution of a biofilm on the current collector to current density, we performed a
268
second (biotic) control experiment, in which we operated the discharge cell as a Microbial
269
Fuel Cell (MFC), first without recirculation of AC granules. After inoculating the anolyte with
270
electrochemically-active microorganisms and controlling the anode potential of the discharge
271
cell at -0.3 V vs Ag/AgCl, the current collector (bio-anode) produced a maximum current of
272
2.7 A/m2 after two weeks. After addition of 50 g non-inoculated granules to the anolyte, that
273
were continuously recirculated via the discharge cell, the current gradually decreased more
274
than 5-fold to 0.51 A/m2 after 21 hours. Thus, during continuous flow of AC granules along
275
the current collector, the activity of the electro-active biofilm on the current collector
276
diminishes. After recirculation of the AC granules was ended, the current produced by the
277
electro-active biofilm on the current collector gradually restored. These results show that
278
biofilm formation on the current collector is possible and can contribute to the total current,
279
however, it seems that the AC granules remove the biofilm, or result in inactivity of the
280
biofilm, when they come in contact with the current collector. In our experiments, therefore,
ACS Paragon Plus Environment
Environmental Science & Technology
281
part of the current may originate from the electro-active biofilm on the current collector itself,
282
but it is likely that most of the current originates from the electrochemically-active
283
microorganisms on the AC granules: current density increased with increasing loading of AC
284
granules, and the recirculation of non-inoculated AC granules in combination with an electro-
285
active biofilm on the current collector resulted in a 5-fold reduced current density of the
286
discharge cell.
287
To study if, at the end of the experiment, the AC granules were colonized by
288
microorganisms, the granules were analyzed by Scanning Electron Microscopy (SEM) before
289
and on day 112. Indeed, a biofilm was observed on the AC granules on day 112 (Figure S2,
290
Supporting Information).
291
3.4 Discussion and perspectives
292
We show a proof-of-principle of the fluidized capacitive anode, where AC granules with
293
electrochemically-active microorganisms are charged in a charging column, and electricity is
294
harvested in an external discharge cell. Advantages of the fluidized capacitive anode
295
compared to standardized MFC set-ups are that a high electrode surface can be achieved in
296
a cost-effective way, that ohmic losses during discharge are minimized, and that the system
297
is well-mixed so that mass transport limitations at the bio-anode are reduced.
298
A high electrode surface area can be achieved with the AC granules, while the discharge cell
299
can be of relatively small size. When high currents can be achieved in the discharge cell, this
300
may offer an economically attractive alternative for scaling up microbial electrochemical
301
systems as the need for the expensive constituents of such a cell (membranes, cathodes
302
with catalyst) are reduced.
303
The second advantage is that, when charged, it is likely that cations surround the AC
304
granules in the electrical double layer. In this way, the generally low conductivity of the
305
wastewater does not pose a major limitation in the charging step. Our hypothesis is that
306
during discharge, these cations are also released, leading to locally high conductivity and
307
therefore minimal ohmic losses in the discharge cell. This can offer advantages compared to
ACS Paragon Plus Environment
Page 16 of 21
Page 17 of 21
Environmental Science & Technology
308
the limited conductivity in MFC designs where wastewater is directly converted into electricity
309
and not stored in AC granules.
310
Because the granules are fluidized, the diffusion layers of acetate towards the biofilm, and
311
protons away from the biofilm, are minimized, and mass transfer is increased. An important
312
issue to address in later study is that, for practical application, mixing should be achieved
313
with minimum energy (gas sparging).
314
The maximum current density achieved in this fluidized capacitive system was 1.3 A/m2. This
315
is lower than the current density that has been achieved with a bio-anode on a flat electrode,
316
up to 4.5 A/m2 at -0.3 V vs Ag/AgCl
317
possible to increase the granule loading because this resulted in clogging. It is likely that a
318
further increase in loading rate will result in a further increase in current density, and further
319
study with a new reactor design will reveal to what extent the performance of the fluidized
320
bed reactor can be improved. Another study on fluidized anode granules that were
321
discharged in-situ, reported current densities up to 2.4 A/m2 at -0.4 V vs Ag/AgCl35. In fact,
322
electro-active microorganisms on the current collector may even have contributed to the
323
current density, though AC granules touching the current collector seem to prevent biofilm
324
formation on the current collector. Visual inspection of the current collector at the end of the
325
experiment showed that the surface was slightly eroded by the AC granules, an erosion not
326
previously observed for the same material operated as a bio-anode without recirculation of
327
granules. It is likely, though, that there were small zones where a biofilm could be formed.
328
Similarly, the biofilm may also detach from the AC granules when touching the current
329
collector, an aspect that we have not studied in more detail here. An interesting question in
330
this respect is how the AC granules can discharge when covered with an electro-active
331
biofilm. Possibly, the electro-active biofilm is conductive, and electrons may be transported
332
via the biofilm to the current collector
333
clear and needs to be addressed in further study.
36
. In the configuration used in this study, it was not
42
. The exact mechanism, however, is at this point not
ACS Paragon Plus Environment
Environmental Science & Technology
334
In addition to enhancing biofilm attachment to the AC granules, several other strategies, like
335
increased particle loading rate, and optimizing retention and cycling times, need to be
336
explored to show the feasibility and applicability of this novel reactor concept for MFCs.
337 338
5. Acknowledgements
339
This work was performed in the TTIW-cooperation framework of Wetsus, Centre of
340
Excellence for Sustainable Water Technology (www.wetsus.nl). Wetsus is funded by the
341
Dutch Ministry of Economic Affairs, the European Union European Regional Development
342
Fund, the Province of Fryslân, the city of Leeuwarden and by the EZ-KOMPAS Program of
343
the “Samenwerkingsverband Noord-Nederland”. The authors like to thank the participants of
344
the research theme “Resource Recovery” for the fruitful discussions and their financial
345
support. Also the authors would like to thank Jan Tuinstra and Razan Rosli for the support in
346
the lab.
347
ACS Paragon Plus Environment
Page 18 of 21
Page 19 of 21
Environmental Science & Technology
348
References
349 350
(1)
Zhou, M.; Chi, M.; Luo, J.; He, H.; Jin, T. An overview of electrode materials in microbial fuel cells. J. Power Sources 196, 4427–4435.
351 352
(2)
Min, B.; Cheng, S.; Logan, B. E. Electricity generation using membrane and salt bridge microbial fuel cells. Water Res. 2005, 39, 1675–1686.
353 354 355
(3)
Kim, J. R.; Cheng, S.; Oh, S.-E.; Logan, B. E. Power Generation Using Different Cation, Anion, and Ultrafiltration Membranes in Microbial Fuel Cells. Environ. Sci. Technol. 2007, 41, 1004–1009.
356 357 358
(4)
Ter Heijne, A.; Hamelers, H. V. M.; De Wilde, V.; Rozendal, R. a; Buisman, C. J. N. A bipolar membrane combined with ferric iron reduction as an efficient cathode system in microbial fuel cells. Environ. Sci. Technol. 2006, 40, 5200–5205.
359 360 361
(5)
Liu, H.; Ramnarayanan, R.; Logan, B. E. Production of Electricity during Wastewater Treatment Using a Single Chamber Microbial Fuel Cell. Environ. Sci. Technol. 2004, 38, 2281–2285.
362 363
(6)
Rabaey, K.; Clauwaert, P.; Aelterman, P.; Verstraete, W. Tubular Microbial Fuel Cells for Efficient Electricity Generation. Environ. Sci. Technol. 2005, 39, 8077–8082.
364 365
(7)
Logan, B. E.; Regan, J. M. Microbial fuel cells - challenges and applications. Environ. Sci. Technol. 2006, 40, 5172–5180.
366 367 368 369
(8)
Michaelidou, U.; Ter Heijne, A.; Euverink, G. J. W.; Hamelers, H. V. M.; Stams, A. J. M.; Geelhoed, J. S. Microbial communities and electrochemical performance of titanium-based anodic electrodes in a microbial Fuel Cell. Appl. Environ. Microbiol. 2011, 77, 1069–1075.
370 371
(9)
Schröder, U.; Schrder, U. Anodic electron transfer mechanisms in microbial fuel cells and their energy efficiency. Phys. Chem. Chem. Phys. 2007, 9, 2619.
372 373
(10)
Lovley, D. R. Microbial fuel cells: novel microbial physiologies and engineering approaches. Curr. Opin. Biotechnol. 2006, 17, 327–332.
374 375 376
(11)
Sleutels, T. H. J. A.; Hamelers, H. V. M.; Buisman, C. J. N. Effect of mass and charge transport speed and direction in porous anodes on microbial electrolysis cell performance. Bioresour. Technol. 2011, 102, 399–403.
377 378
(12)
Cheng, S. A.; Logan, B. E. Ammonia treatment of carbon cloth anodes to enhance power generation of microbial fuel cells. Electrochem. commun. 2007, 9, 492–496.
379 380 381
(13)
Min, B.; Román, Ó. B.; Angelidaki, I. Importance of temperature and anodic medium composition on microbial fuel cell (MFC) performance. Biotechnol. Lett. 2008, 30, 1213–1218.
382 383
(14)
Aelterman, P.; Rabaey, K.; Clauwaert, P.; Verstraete, W. Microbial fuel cells for wastewater treatment. Water Sci. Technol. 2006, 54, 9–15.
ACS Paragon Plus Environment
Environmental Science & Technology
384 385
(15)
Ahn, Y.; Logan, B. E. Effectiveness of domestic wastewater treatment using microbial fuel cells at ambient and mesophilic temperatures. Bioresour. Technol. 101, 469–475.
386 387
(16)
Cha, J.; Choi, S.; Yu, H.; Kim, H.; Kim, C. Directly applicable microbial fuel cells in aeration tank for wastewater treatment. Bioelectrochemistry 78, 72–79.
388 389 390
(17)
Heijne, A. T.; Liu, F.; Weijden, R. V. D.; Weijma, J.; Buisman, C. J. N.; Hamelers, H. V. M.; Ter Heijne, A. Copper recovery combined with electricity production in a microbial fuel cell. Environ. Sci. Technol. 2010, 44, 4376–4381.
391 392 393
(18)
Lefebvre, O.; Ooi, W. K.; Tang, Z.; Abdullah-Al-Mamun, M.; Chua, D. H. C.; Ng, H. Y. Optimization of a Pt-free cathode suitable for practical applications of microbial fuel cells. Bioresour. Technol. 2009, 100, 4907–4910.
394 395
(19)
Rismani-Yazdi, H.; Carver, S. M.; Christy, A. D.; Tuovinen, O. H. Cathodic limitations in microbial fuel cells: An overview. J. Power Sources 2008, 180, 683–694.
396 397 398
(20)
Dekker, A.; Ter Heijne, A.; Saakes, M.; Hamelers, H. V. M.; Buisman, C. J. N. Analysis and improvement of a scaled-up and stacked microbial fuel cell. Environ. Sci. Technol. 2009, 43, 9038–9042.
399 400
(21)
Logan, B. E. Scaling up microbial fuel cells and other bioelectrochemical systems. Appl. Microbiol. Biotechnol. 2010, 85, 1665–1671.
401 402
(22)
Bond, D. R.; Lovley, D. R. Electricity production by Geobacter sulfurreducens attached to electrodes. Appl. Environ. Microbiol. 2003, 69, 1548–1555.
403 404 405
(23)
Park, D. H.; Zeikus, J. G. Impact of electrode composition on electricity generation in a single-compartment fuel cell using Shewanella putrefaciens. Appl. Microbiol. Biotechnol. 2002, 59, 58–61.
406 407 408
(24)
Borole, A. P.; Hamilton, C. Y.; Vishnivetskaya, T.; Leak, D.; Andras, C. Improving power production in acetate-fed microbial fuel cells via enrichment of exoelectrogenic organisms in flow-through systems. Biochem. Eng. J. 2009, 48, 71–80.
409 410
(25)
Arends, J. B. A.; Verstraete, W. 100 years of microbial electricity production: three concepts for the future. Microb. Biotechnol. 2012, 5, 333–346.
411 412
(26)
Janicek, A.; Fan, Y.; Liu, H. Design of microbial fuel cells for practical application: a review and analysis of scale-up studies. Biofuels 2014, 5, 79–92.
413 414 415
(27)
Ter Heijne, A.; Liu, F.; van Rijnsoever, L. S.; Saakes, M.; Hamelers, H. V. M.; Buisman, C. J. N. Performance of a scaled-up Microbial Fuel Cell with iron reduction as the cathode reaction. J. Power Sources 2011, 196, 7572–7577.
416 417 418
(28)
Ter Heijne, A.; Liu, F.; van Rijnsoever, L. S.; Saakes, M.; Hamelers, H. V. M.; Buisman, C. J. N. Performance of a scaled-up Microbial Fuel Cell with iron reduction as the cathode reaction. J. Power Sources 2011, In press.
419 420
(29)
Janicek, A.; Fan, Y.; Liu, H. Design of microbial fuel cells for practical application: a review and analysis of scale-up studies. Biofuels 2014, 5, 79–92.
ACS Paragon Plus Environment
Page 20 of 21
Page 21 of 21
Environmental Science & Technology
421 422 423
(30)
Clauwaert, P.; Van Der Ha, D.; Boon, N.; Verbeken, K.; Verhaege, M.; Rabaey, K.; Verstraete, W. Open air biocathode enables effective electricity generation with microbial fuel cells. Environ. Sci. Technol. 2007, 41, 7564–7569.
424 425 426
(31)
Sleutels, T. H. J. A. . b; Hamelers, H. V. M. .; Rozendal, R. A. .; Buisman, C. J. N. . b. Ion transport resistance in Microbial Electrolysis Cells with anion and cation exchange membranes. Int. J. Hydrogen Energy 2009, 34, 3612–3620.
427 428 429
(32)
Kong, W.; Guo, Q.; Wang, X.; Yue, X. Electricity Generation from Wastewater Using an Anaerobic Fluidized Bed Microbial Fuel Cell. Ind. Eng. Chem. Res. 2011, 50, 12225–12232.
430 431 432
(33)
Deeke, A.; Sleutels, T. H. J. A.; Hamelers, H. V. M.; Buisman, C. J. N. Capacitive bioanodes enable renewable energy storage in microbial fuel cells. Environ. Sci. Technol. 2012, 46, 3554–3560.
433 434 435
(34)
Deeke, A.; Sleutels, T. H. J. a.; Heijne, A. Ter; Hamelers, H. V. M.; Buisman, C. J. N. Influence of the thickness of the capacitive layer on the performance of bioanodes in Microbial Fuel Cells. J. Power Sources 2013, 243, 611–616.
436 437 438
(35)
Liu, J.; Zhang, F.; He, W.; Zhang, X.; Feng, Y.; Logan, B. E. Intermittent contact of fluidized anode particles containing exoelectrogenic biofilms for continuous power generation in microbial fuel cells. J. Power Sources 2014, 261, 278–284.
439 440 441
(36)
Ter Heijne, A.; Hamelers, H. V. M.; Saakes, M.; Buisman, C. J. N. Performance of non-porous graphite and titanium-based anodes in microbial fuel cells. Electrochim. Acta 2008, 53, 5697–5703.
442 443 444 445
(37)
Kuntke, P.; Geleji, M.; Bruning, H.; Zeeman, G.; Hamelers, H. V. M.; Buisman, C. J. N. Effects of ammonium concentration and charge exchange on ammonium recovery from high strength wastewater using a microbial fuel cell. Bioresour. Technol. 2011, 102, 4376–4382.
446 447
(38)
Cao, Q.; Xie, K.-C.; Lv, Y.-K.; Bao, W.-R. Process effects on activated carbon with large specific surface area from corn cob. Bioresour. Technol. 2006, 97, 110–115.
448 449
(39)
Wagterveld, R. M.; Miedema, H.; Witkamp, G.-J. Effect of Ultrasonic Treatment on Early Growth during CaCO3 Precipitation. Cryst. Growth Des. 2012, 12, 4403–4410.
450 451 452
(40)
Dreszer, C.; Vrouwenvelder, J. S.; Paulitsch-Fuchs, A. H.; Zwijnenburg, A.; Kruithof, J. C.; Flemming, H.-C. Hydraulic resistance of biofilms. J. Memb. Sci. 2013, 429, 436– 447.
453 454 455
(41)
Freguia, S.; Rabaey, K.; Yuan, Z. G.; Keller, J. Electron and carbon balances in microbial fuel cells reveal temporary bacterial storage behavior during electricity generation. Environ. Sci. Technol. 2007, 41, 2915–2921.
456 457 458
(42)
Malvankar, N. S.; Lau, J.; Nevin, K. P.; Franks, A. E.; Tuominen, M. T.; Lovley, D. R. Electrical conductivity in a mixed-species biofilm. Appl. Environ. Microbiol. 2012, 78, 5967–5971.
459
ACS Paragon Plus Environment