Gaining a Critical Mass: A Dose Metric Conversion ... - ACS Publications

Sep 16, 2015 - Virginia Tech Institute for Critical Technology and Applied Science (ICTAS), Blacksburg, Virginia 24060, United States. §. NanoSafe, I...
0 downloads 11 Views 1MB Size
Subscriber access provided by University of Massachusetts Amherst Libraries

Article

Gaining a critical mass: A dose metric conversion case study using silver nanoparticles Alan James Kennedy, Matthew S. Hull, Stephen Diamond, Mark A Chappell, Anthony J Bednar, Jennifer G. Laird, Nick Melby, and Jeffery A Steevens Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.5b03291 • Publication Date (Web): 16 Sep 2015 Downloaded from http://pubs.acs.org on September 22, 2015

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 29

Environmental Science & Technology

254x190mm (96 x 96 DPI)

ACS Paragon Plus Environment

Environmental Science & Technology

. 1 2

Gaining a critical mass: A dose metric conversion case study using silver nanoparticles

3 4

Alan J. Kennedy†*, Matthew S. Hull‡§, Stephen Diamond§, Mark Chappell†, Anthony J.

5

Bednar†, Jennifer G. Laird†, Nick Melby†, Jeffery A Steevens†

6

* U.S. Army Engineer Research and Development Center

7

Environmental Laboratory, Building 3270, EP-R

8

3909 Halls Ferry Rd

9

Vicksburg, MS, 39180

10

Voice: 601-634-3344

11

Fax: 601-634-2263

12 13

* Corresponding author: [email protected]; phone: 601-634-3344; fax: 601-634-2263

14 15

† U.S. Army Engineer Research and Development Center, Environmental Laboratory, Vicksburg, MS, USA

16 17

‡ Virginia Tech Institute for Critical Technology and Applied Science (ICTAS), Blacksburg, VA, USA

18

§NanoSafe, Inc., Blacksburg, VA, USA

19 20

1 ACS Paragon Plus Environment

Page 2 of 29

Page 3 of 29

Environmental Science & Technology

. 21

Mass concentration is the standard convention to express exposure in ecotoxicology for

22

dissolved substances. However, nanotoxicology has challenged the suitability of the

23

mass concentration dose metric. Alternative metrics often discussed in the literature

24

include particle number, surface area and ion release (kinetics, equilibrium).

25

unlikely that any single metric is universally applicable to all types of nanoparticles.

26

However, determining the optimal metric for a specific type of nanoparticle requires

27

novel studies to generate supportive data and employ methods to compensate for

28

current analytical capability gaps. This investigation generates acute toxicity data for

29

two standard species (Ceriodaphnia dubia, Pimephales promelas) exposed to five sizes

30

(10, 20, 30, 60, 100 nm) of monodispersed citrate and polyvinylpyrrlidone coated silver

31

nanoparticles. Particles were sized by various techniques to populate available models

32

for expressing the particle number, surface area and dissolved fraction.

33

indicate that the acute toxicity of the tested silver nanoparticles is best expressed by ion

34

release, and is relatable to total exposed surface area.

35

relatable to the observed acute silver nanoparticle effects.

36

2 ACS Paragon Plus Environment

It is

Results

Particle number was not

Environmental Science & Technology

Page 4 of 29

. 37

Introduction

38

Dose metrics based on total or dissolved chemical mass continue to be the standard

39

after

40

nano(eco)toxicology has challenged the efficacy of the mass-only paradigm. Reviews

41

[1,2,3] and documents [4] on the toxicology of nanoparticles (NPs) have discussed the

42

applicability of the mass-only metric without consensus.

43

recognized the need for alternative dose metrics (particle count, surface area, charge,

44

shape) to express the implications of NPs [5,6,7,8,9,10,11,12,13]. Most aquatic ecotoxicology

45

studies continue to express NP toxicity primarily by mass [14], with recent exceptions

46

[15,16,17,18,19]. This is due in part to the intensiveness of characterizing all needed NP

47

attributes (size, surface area, number, agglomeration, dissolution) in aquatic exposures,

48

changes during the assay, lack of standardized guidance on how to apply alternative

49

dose metrics and analytical limitations (low µg/L) at environmentally and toxicologically

50

relevant concentrations [20]. However, the large variability in ecotoxicological endpoints

51

for the same type of NP [21] provides evidence that total NP mass is not predictive of

52

biological effects.

53

The ecotoxicology community has considered size [22,23,24] and shape [25,26,27] effects on

54

toxicity; such work mainly involved comparison to mass-expressed toxicity.

55

dependent toxicity of silver nanoparticles (AgNPs) was observed in many [16,17,18,28,29,30],

56

but not all [31,32] aquatic ecotoxicology studies.

57

toxicity of AgNPs may relate to differences among studies, such as variation in

58

dispersion conditions, overlapping size ranges, polydispersity, dissolution, handling and

59

storage [18,30,33]. Particle number or surface area may be more expedient dose metrics

60

than size and shape [3,34].

61

Recognizing characterization constraints in bioassays, Hull et al. [14] provided

62

calculations to convert mass-based NP data to particle number concentration (NC), total

63

exposed surface area (TESA) and the dissolved fraction (Df), using size and mass as

64

inputs.

65

monodispersed spherical particles; thus, applying them to non-ideal, polydispersed and

66

dynamic particle suspensions (prevalent in the literature) creates uncertainty [13].

decades

These

of

environmental

calculations

toxicology

assume

research.

Environmental

Aerosol toxicologists have

Size-

Inconsistencies in size-dependent

adequate

characterization

3 ACS Paragon Plus Environment

and

stable,

Page 5 of 29

Environmental Science & Technology

. 67

Particle number is recommended in the aerosol science community [5,12,13] and may be

68

representative of particle interactions with biological membranes or dietary uptake [35].

69

Surface area was reported useful in aerosol and microbial toxicology [7,8,9,10,11,12].

70

While the dissolved fraction has less novelty, it must be considered for soluble NPs to

71

avoid confounding other dose metrics since desorption kinetics and particle dissolution

72

are faster for smaller particles [36,37,38].

73

To gain acceptance, a suitable dose metric must be amenable to commonly available

74

measurement capability, logical for setting regulatory threshold values and provide a

75

predictive improvement over mass-based standards. Our objectives were to compare

76

the suitability of mass versus alternative dose metrics (N, TESA, Df) for monodispersed

77

AgNPs in aquatic bioassays.

78

(citrate, polyvinylpyrrlidone (PVP)), and different test species (Ceriodaphnia dubia,

79

Pimephales promelas) on dosimetry conversions was considered. Ceriodaphnia dubia

80

was selected as a filter-feeder (direct particle ingestion) and P. promelas was selected

81

as a predator that may be exposed to particles passively at the gill. We hypothesized

82

that total surface area would be the best predictor of AgNP toxicity, based on previous

83

results that the Df was relatable to the acute biological effects [18,39,40,41,42].

84

Methods

85

Test materials and preparation

86

Citrate- and PVP-AgNPs (10, 20, 30, 60, 100 nm) were obtained from NanoComposix

87

(San Diego, CA).

88

ultrapure water (Milli-Q Plus, 18.2 mΩ/cm, Billerica, MA) while bath sonicating for five

89

minutes (Fisher Scientific model FS-60, 130W, Pittsburgh, PA), according to Coleman

90

et al. [43]. Suspensions were used in fate or bioassay experiments within 30 min of

91

preparation, since storage increases dissolution and toxicity [18]. The AgNP toxicity was

92

compared to dissolved Ag (AgNO3, Sigma Aldrich, 204-390-50G, St. Louis, MO).

The impact of measurement techniques and coating

Working stocks (nominally 10 mg/L) were prepared in 100 mL

4 ACS Paragon Plus Environment

Environmental Science & Technology

Page 6 of 29

. 93

Particle characterization and analytical chemistry

94

Characterization was as previously described [18,44,45].

95

determined by transmission electron microscopy (TEM; Zeiss 10CA, 60kV, Oberkochen,

96

Germany for AgNPs except for 60 nm citrate-AgNPs; a JOEL JEM 1400 for the 60 nm

97

citrate-AgNPs) through measurements of individual particles (≥200, 12 images), using

98

ImagePro® (v7, Media Cybernetics Inc., Bethesda, MD). Hydrodynamic diameter (HD)

99

in suspension was determined by dynamic light scattering (DLS; 635 nm laser; 90

100

Plus/BI-MAS, Brookhaven Instruments, Holtsville, NY) by intensity-weighting and by

101

Field Flow Fractionation (PostNova F-1000 symmetrical flow FFF, Salt Lake City, UT)

102

interfaced to an Inductively Coupled Plasma Mass Spectrometer (ICP-MS, Elan DRC-II,

103

Perkin-Elmer, Waltham, MA).

104

aliquots 1 cm below the water surface. Total silver samples (2 mL) were acidified

105

without further modification. Dissolved silver ( 93-100%. Data were summarized as the mean, and one standard deviation. The geometric mean between TEM and HD for each particle is provided to more heavily weight primary particle size.

Coating

Nominal size (nm)

Measured primary size (TEM images)

Citrate

10

9±4 (1342)

18.1 ± 0.6 (10 – 32)

Citrate

20

Citrate

30

Citrate

60

Citrate

100

PVP

10

PVP

20

PVP

30

PVP

60

PVP

100

19 ± 5 (534) 18 ± 5 (612) 39 ± 11 (143) 102 ± 12 (186) 32 ± 10 (567) 21 ± 4 (868) 31 ± 6 (324) 70 ± 11 1 (717) 122 ± 24 2 (204)

27.8 ± 0.2 (17 – 46) 49.7 ± 0.1 (27 - 89) 63.8 ± 0.6 (43 – 93) 99.7 ± 0.4 (44 – 148) 26.8 ± 0.1 (14 – 52) 32.3 ± 0.4 (18 - 57) 38.9 ± 0.1 (28 – 54) 73.3 ± 0.4 (43 – 122) 98.6 ± 0.2 (63 – 154)

1 2

Geometric Mean (nm)

Nominal Surface area 2 (m /g)

Calculated surface area 2 (m /g)

Percent Dissolved (P. promelas) in biological test media

Percent Dissolved (C. dubia) in biological test media

19.5

13

57.2

63.6

18.9 ± 9.2

20.3 ± 1.6

27.1

23

28.6

30.1

6.5 ± 1.1

5.0 ± 0.8

40.2

28

19.1

31.8

12.1 ± 9.5

3.7

83.4

53

9.5

14.7

6.3 ± 5.5

0.7 ± 0.0

131.9

108

5.7

5.6

1.6 ± 0.8

0.8 ± 0.1

47.4

34

57.2

17.9

3.6 ± 0.6

1.9

30.0

26

28.6

27.2

3.9 ± 1.8

4.0

39.6

35

19.1

18.5

1.2 ± 0.2

0.9

86.7

75

9.5

8.2

2.6 ± 3.2

0.5

127.3

117

5.7

4.7

0.4 ± 0.0

0.2 ± 0.1

Hydrodynamic Diameter in ultrapure water (DLS, nm)

Hydrodynamic Diameter in ultrapure water (DLS, nm)

Second batch used in P. promelas retest (66 ± 8, N = 776) Second batch used in P. promelas retest (115 ± 21, N = 374)

22 ACS Paragon Plus Environment

Environmental Science & Technology

Page 24 of 29

. Table 2. Summary of toxicity reference values for Ceriodaphnia dubia. Lethal median effect metrics are expressed as total measurable silver (LCT50), total exposed surface area (LSA50) and the dissolved fraction (LCD50). Confidence intervals (95%) are provided in parentheses. Median effects concentrations for particle number are not provided since this metric was not predictive of the study material toxicity. Coefficients of variation (CV) for each dose metric are provided. NA = not applicable; n/a = not available # previously excluded as outlier Test material

Nominal size (nm)

Total measureable LCT50 (µg/L)

LSA50 2 (mm /L)nominal size

LSA50 2 (mm /L) TEM Size

LSA50 2 (mm /L) FFF size

LSA50 2 (mm /L) DLS size

AgNO3

Dissolved

NA

NA

NA

NA

NA

Citrate

10

Citrate

20

Citrate

30

Citrate

60

Citrate

100

1.5 (1.3 – 1.6) 16.0 (12.8 – 19.9) 13.7 (11.4 -16.6) # 60.0 (46.1 – 78.2) 32.3 (24.4 – 42.9) 91% 23.5 (19.1 – 29.0) 19.7 (14.8 – 26.2) 29.6 (23.0 – 38.0) 33.5 (26.7 – 42.0) 66.8 (56.6 – 78.9) 54%

84 (76 – 93) 456 (366 – 568) 262 (216 – 316) 572 (439 – 745) 185 (139 – 245) 64% 1346 (1091 – 1680) 563 (422 – 750) 564 (439 – 724) 318 (250 – 404) 382 (323 – 451) 65%

93 (84 – 103) 480 (386 – 598) 436 (361 – 527) 880 (676 – 1147) 181 (137 – 241) 74% 420 (341 – 519) 536 (402 – 715) 545 (424 – 701) 272 (214 – 346) 313 (265 – 370) 30%

43 (39 – 48) 337 (270 – 419) 195 (162 – 236) 412 (316 – 536) 140 (106 – 186) 66% 284 (230 – 351) 375 (261 – 500) 427 (332 – 548) 220 (173 – 280) 300 (254 – 355) 25%

46 (42 – 51) 328 (264 – 409) 158 (131 – 191) 538 (413 – 701) 185 (140 – 246) 75% 502 (407 – 620) 348 (261 – 465) 435 (338 – 558) 260 (204 – 330) 388 (328 – 458) 24%

CV (%) PVP

10

PVP

20

PVP

30

PVP

60

PVP

100

CV (%)

23 ACS Paragon Plus Environment

Dissolved LCD50 (µg/L) 0.3 (0.3 – 0.4) 0.2 (0.2 – 0.3) 0.8 (0.7 – 1.0) 0.1 (0.1 – 0.2) 0.4 (0.3 – 0.5) 0.3 (0.2 – 0.4) 75% 0.9 (0.8 – 1.0) 0.8 (0.6 – 0.9) 0.6 (0.6 – 0.7) NA/ND NA/ND 7436

2047 (1745 – 2401) 2066 (1775 – 2405) 4322 (3941 – 4739) 2428 (2084 – 2830) 1270 (1225 – 1316) 47% 5465 (4486 – 6659) 3951 (3462 – 4510) 7574 (6660 – 8613) 4 >6373

945 (805 – 1108) 1448 (1244 – 1686) 1935 (1765 – 2122) 1135 (974 – 1323) 982 (947 – 1018) 32% 3690 (3029 – 4495) 2766 (2423 – 3157) 5929 (5214 – 6743) >5146

1019 (869 – 1194) 1412 (1213 – 1643) 1565 (1427 – 1716) 1484 (1274 – 1730) 1299 (1253 – 1346) 16% 6526 (5357 – 7951) 2569 (2251 – 2933) 6036 (5308 – 6865) >6086

6.5 (5.5 – 7.6) 4.1 (3.4 – 4.8) 4.5 (3.7 – 5.4) 1.3 (1.0 – 1.6) 5.8 (4.6 – 7.2) 3.4 (3.0 – 3.7) 43% 11.7 (9.2 – 14.9) 5.8 (4.7 – 7.2) 4.5 (3.9 – 5.2) >2.4

PVP

10

PVP

20

PVP

30

PVP

60

32.2 (27.5 – 37.8) 68.6 (59.0 – 79.9) 136.0 (124.0 – 149.1) 165.6 (142.1 – 193.0) 226.4 (218.5 – 234.7) 61% 305.8 (251.0 – 372.5) 145.1 (127.1 – 165.6) 410.5 (361.0 – 466.8) 3 >780

PVP

100

>1100

>6292

>5157

>4942

>6381

NA

84%

101%

75%

79%

81%

83%

CV (%)

CV (%) 3

Extrapolate higher concentration complete kill 774 (644 – 929) µg/L

4

Extrapolate higher concentration complete kill 6707 (5585 – 8054) mm /L

2

24 ACS Paragon Plus Environment

Environmental Science & Technology

. Figure 1. Total and dissolved concentrations of citrate- and PVP-silver nanoparticle (AgNP) dispersions in light and dark conditions. Data are presented as (a) total measureable silver for citrate-AgNPs, (b) dissolved silver for citrate-AgNPs, (c) total measureable silver for PVP-AgNPs, (d) dissolved silver for PVP-AgNPs. Solid points and lines represent the dark condition while open points and dashed lines represent the light condition. Points with different letter designations were statistically significant (lowercase for dark condition, capital letters for light condition). When only one set of letters was provided for a particle size, light condition was not a significant factor in determining concentration.

25 ACS Paragon Plus Environment

Page 26 of 29

Page 27 of 29

Environmental Science & Technology

. Figure 2. Size dependent toxicity of citrate- and PVP-silver nanoparticles (AgNPs). Data are summarized for (a) Ceriodaphnia dubia and (b) Pimephales promelas exposures. In panel (a), the 60 nm citrate-AgNPs were excluded (solid line) and included (dashed line) in the regression. The 60 nm citrate-AgNPs were modeled as an outlier since its toxicity was less than the 100 nm citrate-AgNP; the toxicity of the 100 nm citrate-AgNP supported by Kennedy et al [18]. In panel (b) data were not plotted for PVP-AgNPs since no LC50 could be generated up to the highest exposure concentrations). (a)

(b)

26 ACS Paragon Plus Environment

Environmental Science & Technology

Page 28 of 29

. Figure 3. Comparison of dose-response curves for Pimephales promelas exposed to citrate-silver nanoparticles. Data are expressed as (a) total mass, (b) total exposed surface area, (c) particle number concentration. Relationships for both species, both capping agents and all metrics can be found in the supporting information (Figure S1-4, SI). (a)

(b)

0.8 0.6 0.4 0.2 0.0

1.0

Proportion surviving

10 nm 20 nm 30 nm 60 nm 100 nm

0.8 0.6 0.4 0.2 0.0

10

100

10 nm 20 nm 30 nm 60 nm 100 nm

100

1000

1000

Total surface area (mm2/L) - DLS

Concentration (ug/L)

(c) 1.0

Proportion surviving

Proportion surviving

1.0

10 nm 20 nm 30 nm 60 nm 100 nm

0.8 0.6 0.4 0.2 0.0

1e+7

1e+8

1e+9

1e+10

Particle number concentration (N/mL) - DLS

27 ACS Paragon Plus Environment

10000

Page 29 of 29

Environmental Science & Technology

. Figure 4. Dose response curves related to the dissolved silver concentration measured in exposures. Data are summarized for (a) Pimephales promelas exposed to citratesilver nanoparticles (AgNPs), (b) P. promelas exposed to PVP-AgNPs, (c) Ceriodaphnia dubia exposed to citrate-AgNPs and (d) C. dubia exposed to PVP-AgNPs. C. dubia were also exposed to supernatants taken from select AgNP suspensions. (b)

1.0

Proportion surviving

Proportion surviving

(a)

0.8 0.6 0.4 0.2 0.0

10 nm 20 nm 30 nm 60 nm 100 nm AgNO3

0.01

0.1

1

10

100

1.0 0.8 0.6 0.4 0.2 0.0

10 nm 20 nm 30 nm 60 nm 100 nm AgNO3

0.01

Concentration (µg/L), dissolved

0.1

1

10 nm 20 nm 30 nm 60 nm 100 nm AgNO3

0.8 0.6

10 nm (supernatant) 20 nm (supernatant) 60 nm (supernatant)

0.4 0.2 0.0

1

10

100

Proportion surviving

Proportion surviving

(d)

1.0

0.1

100

Concentration (µg/L), dissolved

(c)

0.01

10

1000

0.8

20 nm (supernatant) 60 nm (supernatant)

0.6 0.4 0.2 0.0

0.01

Concentration (µg/L), dissolved

10 nm 20 nm 30 nm AgNO3

1.0

0.1

1

10

100

Concentration (µg/L), dissolved

28 ACS Paragon Plus Environment

1000