Subscriber access provided by University of Massachusetts Amherst Libraries
Article
Gaining a critical mass: A dose metric conversion case study using silver nanoparticles Alan James Kennedy, Matthew S. Hull, Stephen Diamond, Mark A Chappell, Anthony J Bednar, Jennifer G. Laird, Nick Melby, and Jeffery A Steevens Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.5b03291 • Publication Date (Web): 16 Sep 2015 Downloaded from http://pubs.acs.org on September 22, 2015
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 29
Environmental Science & Technology
254x190mm (96 x 96 DPI)
ACS Paragon Plus Environment
Environmental Science & Technology
. 1 2
Gaining a critical mass: A dose metric conversion case study using silver nanoparticles
3 4
Alan J. Kennedy†*, Matthew S. Hull‡§, Stephen Diamond§, Mark Chappell†, Anthony J.
5
Bednar†, Jennifer G. Laird†, Nick Melby†, Jeffery A Steevens†
6
* U.S. Army Engineer Research and Development Center
7
Environmental Laboratory, Building 3270, EP-R
8
3909 Halls Ferry Rd
9
Vicksburg, MS, 39180
10
Voice: 601-634-3344
11
Fax: 601-634-2263
12 13
* Corresponding author:
[email protected]; phone: 601-634-3344; fax: 601-634-2263
14 15
† U.S. Army Engineer Research and Development Center, Environmental Laboratory, Vicksburg, MS, USA
16 17
‡ Virginia Tech Institute for Critical Technology and Applied Science (ICTAS), Blacksburg, VA, USA
18
§NanoSafe, Inc., Blacksburg, VA, USA
19 20
1 ACS Paragon Plus Environment
Page 2 of 29
Page 3 of 29
Environmental Science & Technology
. 21
Mass concentration is the standard convention to express exposure in ecotoxicology for
22
dissolved substances. However, nanotoxicology has challenged the suitability of the
23
mass concentration dose metric. Alternative metrics often discussed in the literature
24
include particle number, surface area and ion release (kinetics, equilibrium).
25
unlikely that any single metric is universally applicable to all types of nanoparticles.
26
However, determining the optimal metric for a specific type of nanoparticle requires
27
novel studies to generate supportive data and employ methods to compensate for
28
current analytical capability gaps. This investigation generates acute toxicity data for
29
two standard species (Ceriodaphnia dubia, Pimephales promelas) exposed to five sizes
30
(10, 20, 30, 60, 100 nm) of monodispersed citrate and polyvinylpyrrlidone coated silver
31
nanoparticles. Particles were sized by various techniques to populate available models
32
for expressing the particle number, surface area and dissolved fraction.
33
indicate that the acute toxicity of the tested silver nanoparticles is best expressed by ion
34
release, and is relatable to total exposed surface area.
35
relatable to the observed acute silver nanoparticle effects.
36
2 ACS Paragon Plus Environment
It is
Results
Particle number was not
Environmental Science & Technology
Page 4 of 29
. 37
Introduction
38
Dose metrics based on total or dissolved chemical mass continue to be the standard
39
after
40
nano(eco)toxicology has challenged the efficacy of the mass-only paradigm. Reviews
41
[1,2,3] and documents [4] on the toxicology of nanoparticles (NPs) have discussed the
42
applicability of the mass-only metric without consensus.
43
recognized the need for alternative dose metrics (particle count, surface area, charge,
44
shape) to express the implications of NPs [5,6,7,8,9,10,11,12,13]. Most aquatic ecotoxicology
45
studies continue to express NP toxicity primarily by mass [14], with recent exceptions
46
[15,16,17,18,19]. This is due in part to the intensiveness of characterizing all needed NP
47
attributes (size, surface area, number, agglomeration, dissolution) in aquatic exposures,
48
changes during the assay, lack of standardized guidance on how to apply alternative
49
dose metrics and analytical limitations (low µg/L) at environmentally and toxicologically
50
relevant concentrations [20]. However, the large variability in ecotoxicological endpoints
51
for the same type of NP [21] provides evidence that total NP mass is not predictive of
52
biological effects.
53
The ecotoxicology community has considered size [22,23,24] and shape [25,26,27] effects on
54
toxicity; such work mainly involved comparison to mass-expressed toxicity.
55
dependent toxicity of silver nanoparticles (AgNPs) was observed in many [16,17,18,28,29,30],
56
but not all [31,32] aquatic ecotoxicology studies.
57
toxicity of AgNPs may relate to differences among studies, such as variation in
58
dispersion conditions, overlapping size ranges, polydispersity, dissolution, handling and
59
storage [18,30,33]. Particle number or surface area may be more expedient dose metrics
60
than size and shape [3,34].
61
Recognizing characterization constraints in bioassays, Hull et al. [14] provided
62
calculations to convert mass-based NP data to particle number concentration (NC), total
63
exposed surface area (TESA) and the dissolved fraction (Df), using size and mass as
64
inputs.
65
monodispersed spherical particles; thus, applying them to non-ideal, polydispersed and
66
dynamic particle suspensions (prevalent in the literature) creates uncertainty [13].
decades
These
of
environmental
calculations
toxicology
assume
research.
Environmental
Aerosol toxicologists have
Size-
Inconsistencies in size-dependent
adequate
characterization
3 ACS Paragon Plus Environment
and
stable,
Page 5 of 29
Environmental Science & Technology
. 67
Particle number is recommended in the aerosol science community [5,12,13] and may be
68
representative of particle interactions with biological membranes or dietary uptake [35].
69
Surface area was reported useful in aerosol and microbial toxicology [7,8,9,10,11,12].
70
While the dissolved fraction has less novelty, it must be considered for soluble NPs to
71
avoid confounding other dose metrics since desorption kinetics and particle dissolution
72
are faster for smaller particles [36,37,38].
73
To gain acceptance, a suitable dose metric must be amenable to commonly available
74
measurement capability, logical for setting regulatory threshold values and provide a
75
predictive improvement over mass-based standards. Our objectives were to compare
76
the suitability of mass versus alternative dose metrics (N, TESA, Df) for monodispersed
77
AgNPs in aquatic bioassays.
78
(citrate, polyvinylpyrrlidone (PVP)), and different test species (Ceriodaphnia dubia,
79
Pimephales promelas) on dosimetry conversions was considered. Ceriodaphnia dubia
80
was selected as a filter-feeder (direct particle ingestion) and P. promelas was selected
81
as a predator that may be exposed to particles passively at the gill. We hypothesized
82
that total surface area would be the best predictor of AgNP toxicity, based on previous
83
results that the Df was relatable to the acute biological effects [18,39,40,41,42].
84
Methods
85
Test materials and preparation
86
Citrate- and PVP-AgNPs (10, 20, 30, 60, 100 nm) were obtained from NanoComposix
87
(San Diego, CA).
88
ultrapure water (Milli-Q Plus, 18.2 mΩ/cm, Billerica, MA) while bath sonicating for five
89
minutes (Fisher Scientific model FS-60, 130W, Pittsburgh, PA), according to Coleman
90
et al. [43]. Suspensions were used in fate or bioassay experiments within 30 min of
91
preparation, since storage increases dissolution and toxicity [18]. The AgNP toxicity was
92
compared to dissolved Ag (AgNO3, Sigma Aldrich, 204-390-50G, St. Louis, MO).
The impact of measurement techniques and coating
Working stocks (nominally 10 mg/L) were prepared in 100 mL
4 ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 29
. 93
Particle characterization and analytical chemistry
94
Characterization was as previously described [18,44,45].
95
determined by transmission electron microscopy (TEM; Zeiss 10CA, 60kV, Oberkochen,
96
Germany for AgNPs except for 60 nm citrate-AgNPs; a JOEL JEM 1400 for the 60 nm
97
citrate-AgNPs) through measurements of individual particles (≥200, 12 images), using
98
ImagePro® (v7, Media Cybernetics Inc., Bethesda, MD). Hydrodynamic diameter (HD)
99
in suspension was determined by dynamic light scattering (DLS; 635 nm laser; 90
100
Plus/BI-MAS, Brookhaven Instruments, Holtsville, NY) by intensity-weighting and by
101
Field Flow Fractionation (PostNova F-1000 symmetrical flow FFF, Salt Lake City, UT)
102
interfaced to an Inductively Coupled Plasma Mass Spectrometer (ICP-MS, Elan DRC-II,
103
Perkin-Elmer, Waltham, MA).
104
aliquots 1 cm below the water surface. Total silver samples (2 mL) were acidified
105
without further modification. Dissolved silver ( 93-100%. Data were summarized as the mean, and one standard deviation. The geometric mean between TEM and HD for each particle is provided to more heavily weight primary particle size.
Coating
Nominal size (nm)
Measured primary size (TEM images)
Citrate
10
9±4 (1342)
18.1 ± 0.6 (10 – 32)
Citrate
20
Citrate
30
Citrate
60
Citrate
100
PVP
10
PVP
20
PVP
30
PVP
60
PVP
100
19 ± 5 (534) 18 ± 5 (612) 39 ± 11 (143) 102 ± 12 (186) 32 ± 10 (567) 21 ± 4 (868) 31 ± 6 (324) 70 ± 11 1 (717) 122 ± 24 2 (204)
27.8 ± 0.2 (17 – 46) 49.7 ± 0.1 (27 - 89) 63.8 ± 0.6 (43 – 93) 99.7 ± 0.4 (44 – 148) 26.8 ± 0.1 (14 – 52) 32.3 ± 0.4 (18 - 57) 38.9 ± 0.1 (28 – 54) 73.3 ± 0.4 (43 – 122) 98.6 ± 0.2 (63 – 154)
1 2
Geometric Mean (nm)
Nominal Surface area 2 (m /g)
Calculated surface area 2 (m /g)
Percent Dissolved (P. promelas) in biological test media
Percent Dissolved (C. dubia) in biological test media
19.5
13
57.2
63.6
18.9 ± 9.2
20.3 ± 1.6
27.1
23
28.6
30.1
6.5 ± 1.1
5.0 ± 0.8
40.2
28
19.1
31.8
12.1 ± 9.5
3.7
83.4
53
9.5
14.7
6.3 ± 5.5
0.7 ± 0.0
131.9
108
5.7
5.6
1.6 ± 0.8
0.8 ± 0.1
47.4
34
57.2
17.9
3.6 ± 0.6
1.9
30.0
26
28.6
27.2
3.9 ± 1.8
4.0
39.6
35
19.1
18.5
1.2 ± 0.2
0.9
86.7
75
9.5
8.2
2.6 ± 3.2
0.5
127.3
117
5.7
4.7
0.4 ± 0.0
0.2 ± 0.1
Hydrodynamic Diameter in ultrapure water (DLS, nm)
Hydrodynamic Diameter in ultrapure water (DLS, nm)
Second batch used in P. promelas retest (66 ± 8, N = 776) Second batch used in P. promelas retest (115 ± 21, N = 374)
22 ACS Paragon Plus Environment
Environmental Science & Technology
Page 24 of 29
. Table 2. Summary of toxicity reference values for Ceriodaphnia dubia. Lethal median effect metrics are expressed as total measurable silver (LCT50), total exposed surface area (LSA50) and the dissolved fraction (LCD50). Confidence intervals (95%) are provided in parentheses. Median effects concentrations for particle number are not provided since this metric was not predictive of the study material toxicity. Coefficients of variation (CV) for each dose metric are provided. NA = not applicable; n/a = not available # previously excluded as outlier Test material
Nominal size (nm)
Total measureable LCT50 (µg/L)
LSA50 2 (mm /L)nominal size
LSA50 2 (mm /L) TEM Size
LSA50 2 (mm /L) FFF size
LSA50 2 (mm /L) DLS size
AgNO3
Dissolved
NA
NA
NA
NA
NA
Citrate
10
Citrate
20
Citrate
30
Citrate
60
Citrate
100
1.5 (1.3 – 1.6) 16.0 (12.8 – 19.9) 13.7 (11.4 -16.6) # 60.0 (46.1 – 78.2) 32.3 (24.4 – 42.9) 91% 23.5 (19.1 – 29.0) 19.7 (14.8 – 26.2) 29.6 (23.0 – 38.0) 33.5 (26.7 – 42.0) 66.8 (56.6 – 78.9) 54%
84 (76 – 93) 456 (366 – 568) 262 (216 – 316) 572 (439 – 745) 185 (139 – 245) 64% 1346 (1091 – 1680) 563 (422 – 750) 564 (439 – 724) 318 (250 – 404) 382 (323 – 451) 65%
93 (84 – 103) 480 (386 – 598) 436 (361 – 527) 880 (676 – 1147) 181 (137 – 241) 74% 420 (341 – 519) 536 (402 – 715) 545 (424 – 701) 272 (214 – 346) 313 (265 – 370) 30%
43 (39 – 48) 337 (270 – 419) 195 (162 – 236) 412 (316 – 536) 140 (106 – 186) 66% 284 (230 – 351) 375 (261 – 500) 427 (332 – 548) 220 (173 – 280) 300 (254 – 355) 25%
46 (42 – 51) 328 (264 – 409) 158 (131 – 191) 538 (413 – 701) 185 (140 – 246) 75% 502 (407 – 620) 348 (261 – 465) 435 (338 – 558) 260 (204 – 330) 388 (328 – 458) 24%
CV (%) PVP
10
PVP
20
PVP
30
PVP
60
PVP
100
CV (%)
23 ACS Paragon Plus Environment
Dissolved LCD50 (µg/L) 0.3 (0.3 – 0.4) 0.2 (0.2 – 0.3) 0.8 (0.7 – 1.0) 0.1 (0.1 – 0.2) 0.4 (0.3 – 0.5) 0.3 (0.2 – 0.4) 75% 0.9 (0.8 – 1.0) 0.8 (0.6 – 0.9) 0.6 (0.6 – 0.7) NA/ND NA/ND 7436
2047 (1745 – 2401) 2066 (1775 – 2405) 4322 (3941 – 4739) 2428 (2084 – 2830) 1270 (1225 – 1316) 47% 5465 (4486 – 6659) 3951 (3462 – 4510) 7574 (6660 – 8613) 4 >6373
945 (805 – 1108) 1448 (1244 – 1686) 1935 (1765 – 2122) 1135 (974 – 1323) 982 (947 – 1018) 32% 3690 (3029 – 4495) 2766 (2423 – 3157) 5929 (5214 – 6743) >5146
1019 (869 – 1194) 1412 (1213 – 1643) 1565 (1427 – 1716) 1484 (1274 – 1730) 1299 (1253 – 1346) 16% 6526 (5357 – 7951) 2569 (2251 – 2933) 6036 (5308 – 6865) >6086
6.5 (5.5 – 7.6) 4.1 (3.4 – 4.8) 4.5 (3.7 – 5.4) 1.3 (1.0 – 1.6) 5.8 (4.6 – 7.2) 3.4 (3.0 – 3.7) 43% 11.7 (9.2 – 14.9) 5.8 (4.7 – 7.2) 4.5 (3.9 – 5.2) >2.4
PVP
10
PVP
20
PVP
30
PVP
60
32.2 (27.5 – 37.8) 68.6 (59.0 – 79.9) 136.0 (124.0 – 149.1) 165.6 (142.1 – 193.0) 226.4 (218.5 – 234.7) 61% 305.8 (251.0 – 372.5) 145.1 (127.1 – 165.6) 410.5 (361.0 – 466.8) 3 >780
PVP
100
>1100
>6292
>5157
>4942
>6381
NA
84%
101%
75%
79%
81%
83%
CV (%)
CV (%) 3
Extrapolate higher concentration complete kill 774 (644 – 929) µg/L
4
Extrapolate higher concentration complete kill 6707 (5585 – 8054) mm /L
2
24 ACS Paragon Plus Environment
Environmental Science & Technology
. Figure 1. Total and dissolved concentrations of citrate- and PVP-silver nanoparticle (AgNP) dispersions in light and dark conditions. Data are presented as (a) total measureable silver for citrate-AgNPs, (b) dissolved silver for citrate-AgNPs, (c) total measureable silver for PVP-AgNPs, (d) dissolved silver for PVP-AgNPs. Solid points and lines represent the dark condition while open points and dashed lines represent the light condition. Points with different letter designations were statistically significant (lowercase for dark condition, capital letters for light condition). When only one set of letters was provided for a particle size, light condition was not a significant factor in determining concentration.
25 ACS Paragon Plus Environment
Page 26 of 29
Page 27 of 29
Environmental Science & Technology
. Figure 2. Size dependent toxicity of citrate- and PVP-silver nanoparticles (AgNPs). Data are summarized for (a) Ceriodaphnia dubia and (b) Pimephales promelas exposures. In panel (a), the 60 nm citrate-AgNPs were excluded (solid line) and included (dashed line) in the regression. The 60 nm citrate-AgNPs were modeled as an outlier since its toxicity was less than the 100 nm citrate-AgNP; the toxicity of the 100 nm citrate-AgNP supported by Kennedy et al [18]. In panel (b) data were not plotted for PVP-AgNPs since no LC50 could be generated up to the highest exposure concentrations). (a)
(b)
26 ACS Paragon Plus Environment
Environmental Science & Technology
Page 28 of 29
. Figure 3. Comparison of dose-response curves for Pimephales promelas exposed to citrate-silver nanoparticles. Data are expressed as (a) total mass, (b) total exposed surface area, (c) particle number concentration. Relationships for both species, both capping agents and all metrics can be found in the supporting information (Figure S1-4, SI). (a)
(b)
0.8 0.6 0.4 0.2 0.0
1.0
Proportion surviving
10 nm 20 nm 30 nm 60 nm 100 nm
0.8 0.6 0.4 0.2 0.0
10
100
10 nm 20 nm 30 nm 60 nm 100 nm
100
1000
1000
Total surface area (mm2/L) - DLS
Concentration (ug/L)
(c) 1.0
Proportion surviving
Proportion surviving
1.0
10 nm 20 nm 30 nm 60 nm 100 nm
0.8 0.6 0.4 0.2 0.0
1e+7
1e+8
1e+9
1e+10
Particle number concentration (N/mL) - DLS
27 ACS Paragon Plus Environment
10000
Page 29 of 29
Environmental Science & Technology
. Figure 4. Dose response curves related to the dissolved silver concentration measured in exposures. Data are summarized for (a) Pimephales promelas exposed to citratesilver nanoparticles (AgNPs), (b) P. promelas exposed to PVP-AgNPs, (c) Ceriodaphnia dubia exposed to citrate-AgNPs and (d) C. dubia exposed to PVP-AgNPs. C. dubia were also exposed to supernatants taken from select AgNP suspensions. (b)
1.0
Proportion surviving
Proportion surviving
(a)
0.8 0.6 0.4 0.2 0.0
10 nm 20 nm 30 nm 60 nm 100 nm AgNO3
0.01
0.1
1
10
100
1.0 0.8 0.6 0.4 0.2 0.0
10 nm 20 nm 30 nm 60 nm 100 nm AgNO3
0.01
Concentration (µg/L), dissolved
0.1
1
10 nm 20 nm 30 nm 60 nm 100 nm AgNO3
0.8 0.6
10 nm (supernatant) 20 nm (supernatant) 60 nm (supernatant)
0.4 0.2 0.0
1
10
100
Proportion surviving
Proportion surviving
(d)
1.0
0.1
100
Concentration (µg/L), dissolved
(c)
0.01
10
1000
0.8
20 nm (supernatant) 60 nm (supernatant)
0.6 0.4 0.2 0.0
0.01
Concentration (µg/L), dissolved
10 nm 20 nm 30 nm AgNO3
1.0
0.1
1
10
100
Concentration (µg/L), dissolved
28 ACS Paragon Plus Environment
1000