GENERAL RADIO Company - ACS Publications - American Chemical

GENERAL RADIO Company. Anal. Chem. , 1953, 25 (4), pp 8A–8A. DOI: 10.1021/ ... Published online 3 May 2012. Published in print 20 April 1953. Learn ...
0 downloads 0 Views 245KB Size
8A

ANALYTICAL

Accurate

T W O o r THREE TERMINAL

CHEMISTRY

MEASUREMENTS

of Capacitance, Dissipation Factor and Dielectric Constant FROM 6 0 CYCLES TO 1 0 0 KILOCYCLES T h e T y p e 1610-A C a p a c i t a n c e M e a s u r i n g Assembly is a well i n t e g r a t e d g r o u p of i n s t r u m e n t s for h i g h e s t accuracy i n c a p a c i t a n c e a n d dissipation factor m e a s u r e m e n t s . F o r convenience i n use, t h e i n d i v i d u a l u n i t s a r e assembled in a s t a n d a r d b e n c h - t y p e c a b i n e t - r a c k , complete w i t h all inter­ connections. Type 1302-A Oscillator. . . features extremely wide frequency r a n g e of from 10 cycles t o 100 kc a n d excellent frequency stability. Semi-logarithmic frequency selector eliminates crowding at low frequencies, enables precise settings at all frequencies — fre­ quency calibration is ± (l}i% + 0.2 cycles) — harmonic distortion is less than 1% at all frequencies — as much as 80 milliwatts is obtainable into 5000-ohm load — voltage regulation eliminates effects of line-voltage transients. Type 1231-BRA Amplifier and Null Detector with Adjustable 50 cycle to 100 kc Filter. . . c a n b e o p e r a t e d as either a linear amplifier for general-purpose l a b o r a t o r y use or a s a logarithmic a m ­ plifier for null d e t e c t o r use i n bridge m e a s u r e m e n t s . Labeled pushbuttons select linear or semilogarithmic operation and determine input attenuator value — maximum gain of S3 db at 1 kc with 1 megohm load — high null-detector sensitiv­ ity; less than 100 μν input gives 10% meter deflection at 1 kc — aural or visual indication of bridge balance — harmonics and noise eliminated by the Type 1231-P5 Adjustable Filter. Type 716-P4 Guard Circuit. . . supplies a fifth p o i n t t o conven­ t i o n a l four-arm c a p a c i t a n c e bridge n e t w o r k . S t r a y capaci­ t a n c e s referred t o t h i s p o i n t a r e completely eliminated from m e a s u r e m e n t s . . . m a k i n g possible d e t e r m i n a t i o n of direct i m p e d a n c e b e t w e e n t w o p o i n t s of a t h r e e t e r m i n a l network. Four pairs of ratio arms provided for convenient direct-reading operation at 100 cycles, 1 kc, 10 kc, and 100 kc — variable aircapacitor is built into circuit for use in substitution measure­ ments — special double-shielded leads for all connections be­ tween guard circuit, bridge and unknown — all components which might contribute capacitance to ground are mounted in shielded compartment connected to the guard point.

Type 1690-A Dielectric Sample Holder is an auxiliary device which is readily attached to the Capacitance Bridge terminals. This addition makes possible measurement of dielectric constant and loss of practically any solid dielectric. The sample holder's 2" diameter electrodes are ground optically flat and are micrometer driven for utmost accuracy. The instrument is rugged, well shielded and useful at all frequencies to 100 Mc and higher. Additional Price $395.00

Type 716-C Capacitance Bridge . . . t h e h e a r t of t h e m e a s u r i n g assembly. T h i s i n s t r u m e n t is used t h e world over for capac­ i t a n c e s t a n d a r d i z a t i o n a n d dissipation factor m e a s u r e ­ m e n t s . I t also m e a s u r e s i n d u c t a n c e , storage factor a n d characteristics of resistors b y s u b s t i t u t i o n m e a s u r e m e n t s . Wide capacitance range of 100 μμ/ to 1 μ/, direct reading, at 1 kc — direct reading in dissipation factor from 0.00002 to 0.56 — accuracy in substitution measurements is =±0.1% or =*=0.5 μμ/, whichever is the larger — precision capacitor wormcorrection is supplied at extra charge enabling accuracies of =>=0.1% or ===0.2 μμ/—· this bridge is easy to operate — ratio arms, transformers, and unknown terminals are com­ pletely shielded.

Type 1610-A Capacitance Measuring Assembly Complete and ready for operation $1850.00

GR

Admittance Meters ft Coaxial Elements ft Decade Capacitors >ecade Inductors ft Decade Resistors ft Distortion Meters 'requency Meters ft Frequency Standards ft Geiger Counters mpedance Bridges it Modulation Meters iz Oscillators 275 M a s s a c h u s e t t s A v e n u e , C a m b r i d g e 3 9 , M a s s a c h u s e t t s , U . S . A . Variacs ft Light Meters ii Megofimmeters it Motor Controls 90 Weel St. NEW YO«K * 920 S. Michigan. Ave. CHICAGO S 1000 Λ'. Seward St. LOS ANGELES 31, Noise Meters ft Null Detectors ft Precision Capacitors Pulse Generators ft Signal Generators ft Vibration Meters ft Stroboscopes ft Wave Filters U-H-F Measuring Equipment ft V-T Voltmeters ft Wave Analyzers ft Polariscopes

GENERAL RADIO Company