Hiah Performance Thin-layer Chromatography J

The suggestion t h a t thin-layer chromatography can provide quantitative results comparable o r even superior to those obtained with column techniques would appear quite implausible to most practitioners of chromatographic analysis. Not that TLC is without merit as a separation technique, but its established utility has been as a simple, bench-top procedure for quick, qualitative examinations, or even as a clean-up operation used in preparing samples for other chromatographic determinations. Perhaps it is this very simplicity that has led many to contend t h a t qnuntitative TLC is a contradiction in terms, particularly when the separated components a r e measured in situ.After all, there would seem to be a certain element of imprecision associated with determining the amount of material in a volume as undefined as a spot on a thinlayer plate. That TLC is limited to, a t most, semiquantitative determinations is nevertheless a misconception, for recently TLC has begun to attract attention as a highly sensitive, precise, and extremely rapid technique with potential application in nearly every area of analytical interest. This h a s not been the result of any specific breakthrough in instrumentation or materials, but is the culmination of improvements in practically all of the operations of which TLC is comprised. The manifest increase in performance over t h a t obtained in the usual practice of TLC has led to the adoption of “HPTLC” to describe this system, paralleling similar usage in liquid column chromatography to distinguish HPLC from its less instrument-oriented predecessor. Comparisons of HPTLC and HPLC are inevitable because there a r e many areas where either of these systems h a s application. The strengths of column chromatography a r e well-recognized, as witnessed by ita enormous popularity, but its weaknesses a r e often tolerated in the belief that no better alternatives exist, or that the shortcomings will eventually yield to refinement of instrumentation. HPTLC, however, repre252 A

sents a totally differeni approach, and as s u c k avoids many of the problems inherent in column chro matography. The principal difference betwee column and thin-layer chromatography, as described by many authors, is simply that one is a “closed” system and the other is “oDen.” and this obvious distinction is the basis of the-respective advantages of either chromatographic process. Gas chromatography must by the very nature of the mobile phase operate within a closed system; consequently, there is little point in including it in further discussion. But where the mobile phase is liquid, the chromatographic process can function in either a “closed” column or on a n “open” thin-layer plate. I t is understandable that there has been more activity in applying column liquid chromatography to quantitative analysis because of the availability of technology previously established in gas chromatography. The Operations of sample introduction, chromatographic separation, and detection are performed in exactly the same way in HPLC as in GC except for those modifications necessary to accommodate a liquid rather than a gas as the mobile phase. That is, the sampling is sequential, the separated components are eluted with the mobile phase, and detection is a dynamic timedependent process. With thin-layer chromatography these operations are totally different (Table I ) : Many samples may be introduced and run simultaneously, the separation is by development (the components remain in the chromatographic bed), and the detection is static (independent of time). If HPTLC is to be preferred in any given analytical situation over established column techniques, these differences in operation could be clearly advantageous. While this report is not intended as a polemic as

ANALYTiCAL CHEMISTRY, VOL. -53.NO. 2, FEBRUARY 1981

0003-270018 1I035 1-252A$0 1.0010 0 1981 American Chemical Society

r

David C. Fenimore Clarke Analytical Systems P.O. BOX 744

Sierra Madre. Calif. 91024

Chester M. Davis Texas Research Institute of Mental Sciences 1300 Moursund Ave.

Houston. Tex. 77030

pa.,

It-

1

L

1

to whether HPLC or HPTLC is the superior system, a discussion of benefits t h a t derive from open chromatography is in order.

nPTLC Operations Simultaneous Sample Development. A matter of some controversy. which may not be resolved to everyone's complete satisfaction for quite some time, is the relative efficiency of HPTLC compared to HPLC. A column system can operate under rather extreme conditions of pressure differential across the chromatographic bed, and consequently the length of t h a t bed is not as restricted as it is with HPTLC, where mobile phase movement is determined solely by capillary action. HPLC is therefore capable of generating more total theoretical plates than HPTLC and may even produce a given separation in less time than HPTLC. However, on a sample-for-sample basis, HPTLC is clearly superior to HPLC in rapidity of analysis. This derives simply from the capability an open chromatographic bed has for permitting the separation of many samples at the same time. Although this feature of TLC is well-known, the exent to which simultaneous development in HPTLC can contribute to separation speed is perhaps less well appreciated. For example, it is often sufficient to carry the development on a n HPTLC plate no more than 3 or 4 em in order to achieve satisfactory separation, and this can be accomplished in 5 min, more or less, depending on the development solvent. A 10-by-20-em HPTLC plate will readily accommodate 30 samples along each 20-ern edge, and by using a developing chamber in which the solvent travels concurrently from opposite edges toward the center, 60 samples can be developed simultaneously. This amounts to only 5 s per sample! These few seconds per sample do not include the time required for sample application o r quantitation of resolved components,

but improved methods of sample spotting and rapid densitometer scanning add very little to the analysis time of an individual sample. Development Chromatography. Although it is possible to utilize development chromatography in a column system, it is of little practical importance because of the inaccessibility of the chromatographic bed. On the other hand, elution chromatography can be used with thin-layer plates but would serve little useful purpose because development chromatography as an open system carries with it several important advantages. By f a r the greatest number of chromatographic analyses a r e concerned with the measurement of only one o r two wmponents of a sample mixture (together with appropriate internal standards). With development chromatography the conditions are optimized for resolution of only the components of interest, while the remainder of the sample material is left at the origin o r is moved away from the region of maximum resolution. This results in a considerable saving of time compared to elution chromatography, where every component of the sample must traverse the length of the chromatographic bed in order to be measured. The selection of a solvent system to accomplish the required separation may involve a number of trials, but the choice of solvent is quite unrestricted by considerations

Table 1. Comparison of Chromatographic Systems CI0S.M

Sample introduction Chromatography Detection

Single, sequential Elution Dynamic

0Pm Multiple.

concurrent Development static

ANALYTICAL CHEMISTRY. VOL. 53, NO. 2, FEBRUARY 1981

253 A

of interference with detector response or possible deteriorating effect on the stationary phase. Indeed the purity of the solvents employed in HPTLC is not nearly as critical as in HPLC for these same reasons. From the preceding discussion it should not be inferred that development chromatography is confined to determination of only a few components within any given mixture. An open system permits multiple development with any number of solvent systems, hence fractions of widely varying polarity may be moved away from the origin into the region of measurement by successive development in solvent mixtures of increasing strength. For example, this technique has been employed quite effectively in the separation of mycotoxins (I)and the,determination of anticonvulsant drugs in blood plasma (2).In addition, such successive developments need not he carried out in the same direction, for, unlike column chromatography, TLC permits true two-dimensional development with separations that rival and even surpass those ohtained in high-efficiency liquid columns. Static Detection. Elution chromatography as performed by most present-day HPLC instruments is a totally dynamic process with detection an integral and inseparable cornponent of the total system. As such, the chromatographic fractions passing through the detection device cannot he observed any faster or slower than the rate a t which they are being eluted from the column. In other words, dynamic detection must operate within the time constraints estahlished by the chromatographic conditions. Detection in development cbromatography is completely separate from the chromatographic operation and, by contrast, may he considered a static process. Any given chromatographic fraction can be examined for as long as necessary to extract the maximum amount of information, or for as short a period as the time constant of the

detection device and its associated electronics will allow. This freedom from time constraints is potentially the most important aspect of TLC, because it permits utilization of any of a variety of techniques to enhance the sensitivity of detection, such as reactions to increase light ahsorhance or fluorescent emission and wavelength selection for optimum response of each component to be measured. In addition in situ spectra can be obtained for component identification. Not the least of these advantages is the possibility of exploiting computer techniques for optimization of the detected signal by signal averaging, digital filtering, background subtraction, or cross-correlation operations that are either impossible or extremely difficult when the detector has but one opportunity to view a component as it is eluted from a chromatographic column. It is worth remembering that, unlike HPLC, the operations that make up the HPTLC system are not “online” and this lends considerable flexibility in the scheduling of the separate steps of sample application, development, and detection. Thus, samples may he processed “in parallel,” requiring no more than a change of developing solvent or scanning wavelength to move rapidly from one group of samples to another having totally different characteristics. HPTLC Methods Quite satisfactory qualitative results have been achieved in conventional TLC with no more than a disposable pipet for sample application, a glass tank for development, and a selection of suitable spray reagents for visual detection. The procedures used in HPTLC are basically the same, but beyond that rudimentary similarity the techniques differ considerably, much as in the case of HPLC when compared to conventional liquid column chromatography. In order to achieve the resolution, sensitivity, and

Iame 11.

r;ompanson of

I LI;

ana

HP I LI;‘

nc Plate size Sample volume (capillaryapplication) Diameter of spots Diameter of separated spots Solvent migration Detection l i m b Absorption Fluorescence * Fmm: He-,

254,.

-

20 X 20 cm 1-

5pL

HPTLC

10 X 10 cm 0.1-0.2 /AL

3- 6 m m

1.0 mm

6-15 mm

2-5 mm

10-15 mm

3-6 mm

-5 ng -0.1 ng

4 . 5 ng -.01 ng

U.B.(3)

ANALYTICAL CHEMISTRY, VOL. 53. NO. 2, FEBRUARY 1981

quantitative reliability expected of a high-performance system, refinement of materials and methods is necessary. A brief description of HPTLC methods follows. For a more detailed discussion of methods and materials the reader is referred to two recent volumes on the practice of HPTLC ( 3 , 4 ) . T h e HPTLC Plate. HPTLC plates available today from commercial sources are actually fairly similar to standard TLC plates. Most are glass plates coated, for the most part, with silica gel held together with various proprietary binders. The difference is primarily that the average size of the silica gel particles is smaller and the size distribution is tighter. The layer itself is usually somewhat thinner and the surface more uniform than that of standard TLC plates. The increased efficiency realized by the smaller particle size cbromatographic bed results in less band broadening and, hence, improved resolution and greater sensitivity of detection of the separated fraction. In addition, although the small particle size reduces the velocity of mobile phase flow, the length of the chromatographic bed required is markedly less than that encountered in conventional TLC. A comparison of HPTLC and TLC parameters is shown in Table 11. Sample Application. Experience has shown most practitioners of HPTLC that the operation most influential on the quality of separation and quantitation is sample introduction. In order to attain optimum resolution and sensitivity, the size of the applied sample spot must be small-no greater than 1.0 mm in diameter for most commercial HPTLC plates. In addition the sample spots should be as uniform as possible in both shape and size for precise estimation of separated components. Clearly, this eliminates the usual fire-drawn glass pipet as a means of sample delivery. Assuming an even distribution of solute in a sample solution deposited on the adsorbent layer, a volume of approximately 0.1 pL will produce a I-mm spot on most HPTLC plates. If the solute has a low Rr (ratio of sample migration to solvent travel) in the sample solvent, larger volumes may be used; but often those solvents have low polarity or solvent strength and are not the best for quantitative transfer of the solution from the spotting device. One of the more convenient means for manipulating such small volumes is a micropipet constructed from platinum-iridium capillary tubing fused into the end of a length of glass tubing. These pipets are usually mounted in a fixture that permits close control of the pressure exerted by the tip on the absorbent layer and also precisely

When everything fits together

I

I

KONTRON Analytical UV/VIS Spectrophotometers IFully digitalized electronics with microprocessors H Individual Program Files H Built-in

810 2.) WIKOW 820 3.) WIKOW 710 4.) Same as UVIKON 810, ledion ma keyhoard of four da-nt bandwdths (0.5, 1.0, 2 0 h

rice Ave. Redwood City, CA 94063

H~gh-performanoe single-beam with fu6d 2.ONM bandwidth. Other bandwtdh of 0.5,1.0 & 4.0 NM can be manually changed.

Tel. (415) 361-1012

CIRCLE 122 ON READER SERVICE CARD

positions the pipet for repetitive delivery of sample, an important consideration if greater amounts of sample must be applied than can be accommodated by the small volume of the pipet. Very reproducible sample delivery can be achieved with such devices, providing the solution flows easily in and out of the capillary tubing. Unfortunately, many sample solutions, particularly extracts of biological materials, become quite viscous when concentrated to low volumes. Therefore, successive applications of a dilute solution must be made to the same spot if sensitivity is to he preserved. An alternative method recently reported (5) removes most of the solvent from the sample solution prior to application to the HPTLC plate. With this procedure, termed “contact spot. ting” (Figure l),relatively large volumes of sample solution are evaporated on a treated fluoropolymer film positioned over a number of depressions in a metal plate. After the solvent is evaporated by gentle heat and nitrogen flow, the thin-layer plate is positioned adsorbent side down over the film, and the sample residues are transferred by bringing the film into contact with the adsorbent. Thus, many samples can be applied simultaneously, and spot diameters a fraction of a millimeter can be obtained with starting volumes as large as 0.1 mL. Plate Development. The open, two-dimensional chromatographic bed of a thin-layer plate allows more choice in the direction of mobile phase flow than do closed systems, and three different systems are presently in use with HPTLC linear, circular, and anticircular. Of these, linear development (Figure 2a) is the most familiar

Flgure 1. Sample introduction by contact spotting. A specially treated fluoropolymer film is pulled into a series of depressions in a metal plate by application of vacuum (a and b). Sample sobtion is delivered by pipet (c).and after evaporation a residue remains (d). which is transferred to the HPTLC plate by replacing the vacuum with slight pressure (e)

to users of TLC, and in its simplest form requires no more than contact of one edge of the plate with the developing solvent-usually accomplished by standing the plate vertically in a

few milliliters of solvent in a suitable container. Better performance can be achieved if the plate is horizontal during development (solvent travel is unimpeded by gravity) and if the free volume surrounding the plate is minimal (more rapid and uniform equilibration of liquid and vapor phases). In such an arrangement, the solvent is usually fed to the plate by capillary action, and with the plate horizontal there is no difficulty in supplying solvent from opposite edges at the same time, as mentioned previously. An example of this type of linear development is illustrated in Figure 2h. As mentioned previously, TLC permits two-dimensional development, particularly useful for examining many components of a complex mixture. By utilizing the entire surface of the plate for separation of a single sample the resolving power is nearly the square of that attainable in a onedimensional development. The usual two-dimensional development (Figure 3a) accommodates only a single sample applied to one corner of the plate; but four samples can be chromatographed simultaneously using convergent solvent flow (Figure 3b). In circular chromatography the solvent is introduced by a wick or pumped through capillary tubing to the adsorbent layer and allowed to move the samples radially from a central point. This mode of development (Figure 4a) appears to improve resolution of components at low Rr and is faster than linear HPTLC. Anticircular chromatography supplies the solvent through an annular capillary space to the periphery of a circle, and the solvent then moves inward to converge at the center, as shown in Figure

............... ............... ...............

...............

............... ............... ............... 0 0 0 0 0 0 0 0 * 0 0 0 0 0 0

............... ............... ............... 0 0 0 0 * 0 0 0 0 0 0 * 0 0 0

............... ...............

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

............... ............... ............... (b)

Figure 2. Linear HPTLC development with (a) solvent flow in one direction, and (b) simultaneous flow from opposite directions 258A

ANALYTICAL CHEMISTRY, VOL. 53. NO. 2, FEBRUARY 1981

A

Introducing the Model 560 ESCA/SAM. A complete surface chemistry laboratory.

Most analytical and research laboratories face a wide range of surface chemistry problems, so multiple surface analysis techniques are needed to do the job. That’s why PHPdesigned the new Model 560 ESCA/SAM for optimum, computerized ESCA and SAM performance. Each technique offers unique advantages for different types of samples. Used together, they provide a more detailed analysis and a higher probability of getting the correct answer to a problem. PHI’S new SlMS D accessory can also be added to the Model 560. Software for the integral computer system covers all of these techniques practically and efficiently. Fealures include:

Maximum Sample Throughput A sample introduction system, combined with the integral computer system, ensures the highest

sample throughput and lowest cost per sample.

High ESCA Count Rates A new, high flux, dual anode x-ray source in combination with a cylindrical-mirror analyzer provides higher count rates for excellent ESCA sensitivity.

Improved SAM Performance Redesigned coaxial electron gun provides beam diameters below 2pm for improved SAM resolution and SEM imaging.

Total System Automation Computerized system control and data manipulation increase sample throughput. Available software provides maximum spectral information for a more thorough analysis.

Optional Transfer Vessel A special transfer vessel allows sample pre-treatment and transfer to the analysis chamber without exposure to outside atmosphere.

For More Information To find out how this unique new instrument can help you solve your materials problems, contact the office nearest you. Minneapolis, MN. USA: PerkinElmer, Physical Electronics Div.. 6509 Flying Cloud Drive, Eden Prairie, MN, USA, 55344; Telephone (612) 941 -5540. Munich, West Germany: PerkinElmer GmbH. Physical Electronics Div., Bahnhofstrasse 30, D-8011 Vaterstetten. Germany. Hong Kong: Perkin-Elmer, Surface Sciences Div.. 303 Fourseas Building, 208-21 2 Nathan Road, Tsimshatsui, Kowloon, Hong Kong Japan: Contact Ulvac Corporation, Tokyo.

Physical Electronics

PERKIN-ELMER Responsive Technology CIRCLE 189 ON READER SERVICE CARD

ANALYTICAL CHEMISTRY, VOL. 53. NO. 2, FEBRUARY 1981

257 A

.. i

e

I I -_I__

.

I I

I

. . .

e

.

.I.

I 0

.

Flgure 3. Two-dimensional development. (a) Solvents A and B used successively at right angles. (b) Solvent flow from opposite edges permits simultaneous four-sample, two-dimensional development

4h. Resolution at high Rfvalues is reported to he favored by this approach, and, again, the speed of development is much greater than with linear flow. While each of the various systems may offer advantages in certain analytical applications, linear development does not require much in the way of sophisticated equipment, and in practice provides the resolution and reproducibility required for most quantitative determinations. Scanning Densitometry. Quantitation of the components separated by HPTLC is usually performed in situ with photometric measurement of ahsorbed light or emitted fluorescence. In absorption densitometry the spots on the HPTLC plate are scanned by a beam of monochromatic light formed into a slit image with the length of the slit selected according to the diameter of the largest spot. The diffusely reflected-or scattered-light may then he detected with a photomultiplier. Those areas of the plate that are free of light-ahsorbing materials will yield a maximum signal, and the separated spots will cause a diminution of reflected light that is concentration dependent. At this time there are three optical systems that are employed predominantly in scanning densitometers. The first, shown in Figure 5a, is a simple single beam arrangement with the light emerging from the monochromator perpendicular to the surface of the thin-layer plate. Diffusely reflected light is detected by a photomultiplier. The plate is mounted on a movable stage, usually motor driven in the direction perpendicular to the slit length, and either manually operated or motor driven in the orthogonal di258A

rection. This arrangement is quite capable of producing excellent quantitative results, but baseline drift may he troublesome due to extraneous ad. sorbed material in the thin-layer, which can move during chromatographic development. This problem may he overcome by using a double-beam scanner (Figure 5h) with a reference beam scanning the intervening space between sample lanes. The difference signal thus eliminates the contribution of general plate background. Small irregularities in the plate surface as well as undesired background contributed by the sample itself may still pose a problem. Consequently, the dual-wavelength system (Figure 5c) is designed to minimize these effects. Two monochromators alternately furnish to the same sample lane a reference wavelength with minimal sample absorbance and a sample wavelength chosen for maximum absorbance. The reference wavelength cancels out background and corrects for plate irregularities. These various densitometers provide for a choice of light sources and optics, permitting a range of wavelengths from helow 200 nm through the visible spectrum. An example of an ahsorhFlgure 4. Circular chromatography (a)

with development solvent introduced at a central point to a ring of initial sample spots. Anticircular chromatography (b) requires solvent delivery from an annular capillary space to the periphery of the circle enclosing the sample spots. A zone of adsorbent layer is removed to prevent solvent migration in the opposite direction, and the solvent converges at the center of the circle

ANALYTICAL CHEMISTRY, VOL. 53. NO. 2, FEBRUARY 1981

I

. .

. .

vow infrared I

c ad&&^ begiuning.

If you want to truly advance your laboratory’s infrared analysis capability, first consider the primary spectral data itself. The fundamental superiority of spectral quality is the overwhelming advantage of Nicolet’s Mx-1

1

whencomoaredtoa iispersive instrument 3r to any competitive Fourier transform IR system. This basic superiority arises from the Mx-l’s uncompromising design and its use of the Fourier transform technique, which provides the intrinsic advantages of speed, sensitivity, resolution, optical throughput, wavelength accuracy, and

negligible stray light In your laboratory, these advantages help you solve problems by saving time, increzing analytical produc tivity, assuring accurak quantitation, and allowing you to measure samples that you previously found extremely difficult or impossible, such as microsamples, highly absorbing or scattering materials, and dynamically changing samples. %se advantages cannot be gained @ adding a data starion to a diqersive @cm-

mtq as this unll not improve the quality of rht. primary data

co~pove

&ta

hnnrmng

capamities and ease of

operaaon

7

I

The I@-1 is based around the large-scale Mx-80 processor, giving computational power that is , conveniently implemented through

I

subtract spearahan- ‘ ually or automatically to remove solvent or interfering bands, smmth spectra, perform accurate quantitative analyses automatically, select a large variety of plot formats, and much more. This intrinsic computational power, coupled with the highspeed plotter, gives you a real cost saving while achieving performance superior to that of any dispersive spectrometer with added data station.

LiD-

-

-(w)

%e 3 ~ m ~ f$wthe i

%zz!t=zri “possihIebig:

The standard Mx-1 generates a Sadtler SpecFinder@d e so you can l m k up the compound in reference bmks available from Sadtler Research Laboratories. When supplied with the optional disk accessory, the Mx-I performs the search automatically, listing as many as 99 closest compounds and a metric number indicati closeness of the match. If your compound isn‘t in the library, the routine still gives you lots of information regard-

ing the class of compound and functional groupings.

or, create yo-

ovll library for sg -. With the diskette storage module, you on build your own custon library consisting of those compounds important to your work Each diskette holds up to 500 compressed library spectra.

Mdthedorfnl 12008 Data srstem, aplp.de your MX-1 to a

-b-

routintlrestoreh .ystemThis new interactive color-graphics data station facilitates spectral L

I

of background spectra in seven colors. Using simple command3, you can perform a full set of mathematical operations on spectra, integrate spectral peaks, and perform quantitative calculations. MACRO programming capabilities allow you to preprogram and store programs for sample measurement experiments and/or dap processing, and then perform these experiments later by simply pushing one of the eight exDeriment control b;ttons. NICFORTH language pro-

i

1

New 12009 imteIICtlve coler-p.pblu data t d u results ofa multlple subPnrrion M dlsptnyed h e .

L The

I

P -p

Flgure 5. (a) Simple, single beam scanning densitometer. L, lamp: MC, monochromator; PM, photomultiplier: P, thin-layer plate. (b) Dual beam arrangement with beam splitter. Reference beam corrects for plate background by scanning between sample lanes. (c)Single beam, dual wavelength scanner. A referencewavelength chosen for minimal sample absorption corrects for plate irregularitiesas well as background in the sample lane. CH, chopper Figure 8. Absorption-reflectance scan of imipramine (I) and desipramine (D) extracted from a 1.0 mL b l d plasma

sample, at concentration of 100 nglmL. Internal standard (IS) is butaperazine

ance scan of the tricyclic antidepressant drug imipramine and its metabolic product desipramine extracted from a blood plasma sample is shown in Figure 6. The response of such reflectanceabsorbance scans is nonlinear with concentration and, as would be expected, subject to perturbations not encountered in solution densitometry. This is not a serious problem because tbe multiple sample capability of HPTLC permits the inclusion of calibration standards with each sample run. Consequently, all samples, both standards and unknowns,me subjected to exactly the same chromatographic conditions, and systematic errors remain very much a t a minimum. The relative standard deviation of determinations such as that shown in Figure 6 is usually less than 4%, and may even fall below 2%. Determination of pure standards often produces errors less than 1%. Despite the excellent results ob-

-

o

262A

I 2

3 4cm

Flgure 7. Fluorescent scan of Prolixin

(fluphenazine)from blood plasma (upper trace) at a concentration of 0.6 nglmL. Internal standard is triflupromazine. Lower trace is blank blood plasma

ANALYTICAL CHEMISTRY, VOL. 53. NO. 2, FEBRUARY 1981

I

P

I L

-

0 1 2 3 4 e m

I

Though hidden in antiquity, dice probably evolved from prehistoric games of knucklebones. The use of dice for games developed first in the Orient, while dice similar to those in use today are depicted on Egyptian monuments and have been found in the ancient ruins of Thebes. Mark Antony was said to have wasted his time in Alexandria by playing dice. In 18th century England great fortunes were won and lost with the single roll of the dice. Today games of chance are still a major influence within our society. However, decisions regarding analytical instrumentation, although involving a degree of risk, should not be left to chance. When faced with decisions regarding plasma emission instrumentation, consider Spectra-

Metrics, the one company that provides an intelligent alternative to risk. The SpectraSpan 111-B from SpectraMetrics is the first plasma emission spectrometer offering either DCP or ICP excitation sources. Furthermore, the Multiple Source Spectraspan System 111-B offers both DCP and ICP sources in a configuration which provides for simple switchover from one source to the other. Utilizing the high-resolution echelle spectrometer, the System 111-B offers true simultaneous multi-element analysis in either ICP or DCP mode. Many factors come into play while making instrumentation decisions. DON’T TAKE A CHANCE, CALL SPECTRAMETRICS ...WHERE YOU HAVE A CHOICE.

See us a t Atlantic City, Booths 500-511 , 527-529 and Seminar Room SR 21 5.

.

SpectraMetrics, Inc 204 Andover Street Andover, MA 01810 (617) 475-7015 Telex 94-7134 A Subsidiary of Beckman Instruments, Inc.

____

.

CIRCLE 272 ON READER SERVICE CARD OSpectraMetrics, Inc., 1981

xtra-Physics is changing the m--quidchromatography. heart c-

Now determine As, Se, and Hg with a light heart and an I1AVA:"

220 240 260 280 300 320

220 240 260 280 300 320 Wavelength (nm)

Wavelength (nm)

Flgure 8. In situ UV spectra of four psychopharmacologic agents obtained by suacessive scans from 220 to 320 nm

tained with reflectance-absorbance densitometry, fluorescence measurements are usually preferred if the substance in question is or can be made fluorescent under appropriate excitation. The limit of detectability is considerahly enhanced-it is frequently in the low picogram range-and the linearity of response and selectivity of detection are much improved. A single beam mode of operation of the densitometer is usuaily quite sufficient for

Chlorpromazine

I! Imiprai

.......

\

Clozapine

\I

Thiothixir

I I

1

J

fluorescence photometry, with the simple addition of a cutoff filter ahead of the photomultiplier to block the excitation wavelength. Mercury or xenon lamps are available with most instruments to provide excitation. An example of a scan in this mode is shown in Figure 7. This, again, is a drug extracted from blood plasma and is illustrative of the sensitivity that can be attained with in situ fluorescent photometry. I t is of interest that this particular compound has a relatively modest fluorescent yield compared to such strongly fluorescent compounds as the porphyrins or the aflatoxins, which are detectable in amounts below 10 pg on the thin-layer plate (I, 3). Future Trends Although TLC is one of the oldest forms of chromatographic separation, HPTLC is still very much in its infancy. Refinement accompanies use, which has certainly been the case with GC and HPLC, and there remain many intriguing possibilities for improvements of HPTLC methodology. The HPTLC plates currently available from commercial sources, while very much better than TLC plates, cannot be regarded as the ultimate hy any means. Market demands will very likely stimulate development of plates with much smaller particle size distributions. more uniform adsorbent thicknesses, and even smaller average particle sizes. The minimum Rpot diameter that can be achieved on a developed plate is a function of plate ei-

Admit it: When you have to determine arsenic, selenium, or mercury, your heart sinks. The levels are low; the furnace is difficult; hydride/ mercury vapor systems are messy. No more. ICs new Atomic Vapor Accessory (AVA) completely automates the hydridehercury process. Just place the acidified sample, in any size up to 200 mL, in a Fleaker" and press START. AVA does the rest: adds the reagent, stirs, times the reaction, passes the sample vapor through a heated cell, and triggers the AA instrument to take the reading. You can use AVAwith any IL AA instrument. You can also use it to add a little class to most AA instruments from other manufacturers. Instrumentation Laboratory Inc , 56 Jonspin Road, Wilmington, MA 01887 Tel : 617-658-5125.

The leader in atomic spectroscopy has a new name...

I / ' 2

3

cn

Figure 9. Cross-correlation of a chro6togram against the UV spectrum of a single component (chlorpromazine)of a drug mixture. showing peak and background suppression

lnstrumentatlon laboratory CIRCLE 109 ON READER SERVICE CARD

ANALYTICAL CHEMISTRY, VOL.

53, NO. 2,

FEBRUARY 1981

265 A

P M P ~lrom P owe TEFLON" TFE

C ~ E M F L U O Rope and w m g s offer yo. a ne* cno,ce n 11- a trawler systems ha longer mLst you cnoose belween owel ~ W S S L Wplastic tioing syslems or exotic meta s CnEMFLUOR pipe IS more r q q e a and D ~ O Voes m,ch n qher warring pressbres tnan stanoard TFE tbb nq Wnen compared 10 meta s tne ne* T F E owe IS more cnemica y nerl ana non conlam nal ng 11 afso reo aces glass syslems m e r e orearaqe is a of00 em CHEMFLUOR p oe s arai able n slandard hPT sues ranqing tiom a Un w e NPT ( 312' 0 D I sue spec Ica y aesgned tor laooralory .re Io ' 2 . NPT 84. o D I w i n larger s zes availaQ e on reqiest For maximum venal lily Componenls are availaole to nterconnect tne neu DlDe to exist ng CHEMFLUOR Fluno Flow [LO nq s p m s an0 to CHEMWARE' aoo1aloly qlass adaotors n ado t an CHEMFLUOR olpe s rig 0 anD can be cut and lnreadea u I n s mole hand 100 s It s mucn eas er to set JD tnan mela, Pwe syslems

,

SEE US AT THE PITTSBURGH CONFERENCE BOOTH 4054

For more Infarmailon. call or wrlie:

C H ~ U ~ L U OCHEUWPPF R T ~ F L O ) ~ 0 ~ ~ o m n s I9

u

C n m ~ l a i1 l1 4 1

M \,,,l"I

CIRCLE 45 ON READER SERVICE CARD

ficiency which, in turn, is a reflection of these aforementioned factors. Bearing in mind that on a surface such as a TLC plate, concentration increases by the inverse square of its spot diameter, improvements of efficiency can greatly extend the sensitivity of detection as well as enhance resolution. Smaller developed spots also place greater demands on the optical systems of scanning densitometers, so it follows that improved instrumentation must surely be in the offing. With only one or two exceptions the scanners now in use were designed with macro TLC plates in mind and have merely been adapted to HPTLC. Thus, densitometers will most certainly be developed to answer the unique requirements of HPTLC from the standpoint of both refined optical systems and digitized control and data acquisition. The application of computer techniques to HPTLC scanners will also simplify the optical systems, because rapid scanning with data storage and processing is a very effective alternative to optical correction of baseline drift. An even more promising use of computer techniques is in the manipulation of the acquired data to suppress response of some peaks while preserving that of others. For example, the ultraviolet spectra obtained directly from scans of an HPTLC plate are shown for four drugs in Figure 8. By scanning a chromatogram at various selected wavelengths and then performing a cross-correlation operation against the previously determined UV spectrum for one of these compounds, only the peak which corresponds to that spectrum remains undiminished

L

in intensity (Figure 9). Similarly, correlations of in situ UV spectra and & values could lead to rapid identification of resolved (or even partially resolved) components of complex mixtures. Again, it should be emphasized that such operations are facilitated in HPTLC by the absence of time constraints in the detection process. It is not beyond the present state of mechanical, optical, and computer technology to design an instrument that can scan a plate containing as many as 60 samples (spotted and de. veloped in less than 10 min!) at a number of different wavelengths, identify the separated fractions by correlation against &values and UV spectra, correct baseline fluctuations, and quantitate selected components against generated calibration curvesall in a matter of minutes or less. These future prospects offer exciting possibilities in application to the many analytical problems now considered the exclusive province of column chromatography. References ( 1 ) Lee.K.Y.;Poole.C F.:Zlatkis.A.

Anal Chem. 19R0.52. R17-41. (21 1)avis.C. M.. Fentmore. D. C . J . Chro. molocr.. in pres,. (3) Zlatkis, A,; Kaiser. R. E. "HPTLC Hirh I'erformanre ThimLayer Chromstouraohv": Elsevier Scientific Publishine Company:'Amsterdam. New York, 1977. (4) Rertsch. W.; Ham. S.: Kaiser. R. E.; Zlatkis. A. "Instrumental HPTLC," Proceedinw of the First International Svrn&&on Instrumentalized High Pir.

~.~

.7"".

(5) Fenirnore, D. C.; Meyer, C. J. J. Chromologr. 1979,186,555-61.

David C.Fenimore (seated) received a BA from DePauw University in 1952 and. as a student of Albert Zlatkis a t the University of Houston, was awarded a PhD in 1966. He then joined the staff of the Texas Research Institute of Mental Sciences as head of the Instrumental Analysis Section, where he was engaged in the development of instruments and methods for the analysis of psychoactive compounds. He is presently chief executive officer of Clarke Analytical Systems, Sierra Madre. California.

Chester M. Davis received a BS from the University of Texas in 1966, and a PhD from the University of Texas Graduate School of Biomedical Sciences in 1975, under the supervision of Fenimore. Davis has now succeeded Fenimore on the staff of the Institute of Mental Sciences.