Subscriber access provided by READING UNIV
Article
Highly Efficient Interception and Precipitation of Uranium (VI) from Aqueous Solution by Iron-Electrocoagulation Combined with Cooperative Chelation by Organic Ligands Peng Li, Bao Zhun, Xuegang Wang, Ping Ping Liao, Guanghui Wang, Lizhang Wang, Yadan Guo, and Weimin Zhang Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b05288 • Publication Date (Web): 28 Nov 2017 Downloaded from http://pubs.acs.org on December 2, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 33
Environmental Science & Technology
1
Highly Efficient Interception and Precipitation of Uranium (VI) from
2
Aqueous Solution by Iron-Electrocoagulation Combined with
3
Cooperative Chelation by Organic Ligands
4 5 6 7 8 9 10 11
Peng Lia,b* , Bao Zhunb, Xuegang Wanga,b, PingPing Liaob, Guanghui Wanga,b, Lizhang Wangc* Yadan Guoa,b and Weimin Zhanga,b a
State Key Laboratory Breeding Base of Nuclear Resources and Environment, East China University of Technology, Nanchang City, Jiangxi 330013, China, PR China
b
School of Water Resource & Environmental Engineering, East China University of Technology, Nanchang City, Jiangxi 330013, PR China c
School of Environment Science and Spatial Informatics, China University of Mining and Technology, Xuzhou City, Jiangsu 221008, PR China
12
ABSTRACT: A new strategy combining iron-electrocoagulation and organic ligands (OGLs)
13
cooperative chelation was proposed to screen and precipitate low concentrations (0–18.52 µmol/L)
14
of uranium contaminant in aqueous solution. We hypothesized that OGLs with amino, hydroxyl,
15
and carboxyl groups, hydrophobically/hydrophiliclly would realize precuring of uranyl ion at
16
pH IDA >
190
EDTA > PANI, which is in line with their uranium removal performance in the bulk experiments.
191
Interestingly, Figure 1 shows that the optimum pH for uranium iron-electrocoagulation after the
192
cooperative chelation by OGLs remained at 6.0. This was corroborated by the Zeta potential
193
measurements of the obtained precipitated flocs at different pH conditions in Figure 2b. The zeta
194
potential at pH 6.0 was much lower than at other pH conditions, while the reactions in the
195
iron-electrocoagulation system reached the highest level. The generated iron oxides and
196
hydroxides would be important for screening the U-OGLs and the accumulative crystallization.
197
The identical optimum solution pH for uranium removal by iron-electrocoagulation in the
198
presence and in the absence of cooperative chelation by OGLs also indicates that analogous
199
precipitate evolution processes took place before and after the intercalation of OGLs, and that the
200
added OGLs did not affect the intrinsic electrochemical reactions of the iron-electrocoagulation
201
system.
ACS Paragon Plus Environment
Uranium concentration (mg/L)
Environmental Science & Technology
a)
4
4
4
4
4
3
3
3
3
2
2
2
2
2
1
1
1
1
1
0 3.0
4.5
6.0
7.5
9.0
0
0 3.0
4.5
6.0
7.5
9.0
3.0
4.5
Solution pH
Solution pH
6.0
7.5
9.0
0 3.0
4.5
6.0
7.5
9.0
3.0
Solution pH
Solution pH
Initial After Treatment
e)
d)
3
0
202
c)
b)
Page 10 of 33
4.5
6.0
7.5
9.0
Solution pH
203
Figure 1. Precipitation of uranium from water with iron-electrocoagulation in the absence and in presence of
204
organic ligands: a) in the absence organic ligands; b) IDA; c) Alizarin S; d) PANI; e) EDTA. Initial uranium
205
concentrations were in the range of 8.35 to 15.70 µmol/L (2.255 to 4.238 mg/L) as indicated in the figure. The
206
current density 0.6 mA/cm2, OGLs-to-U (VI) mole ratio 3:1. The solid blue circles represent the initial
207
concentrations of uranium in aqueous solution, while the empty red ones symbol those after 24 mins reactions
-5
-5.0
a) Zeta potential (mV)
Zeta potential (mV)
-7 -8 -9
-6.0 -6.5 -7.0 -7.5
-10
-8.0
-11 Without U and OGLs
208
b)
-5.5
-6
U with no OGLs
EDAT
Alizarin S
PANI
IDA
3
4
Different ion-electrocoagulation condition
5
6
7
8
9
Solution pH
209
Figure 2. Zeta potential of the precipitated flocs obtained at (a) different ion-electrocoagulation condition and (b)
210
Alizarin S as organic ligands at different solution pH values. The experimental condition was initial uranium
211
concentrations 8.35 to 15.70 µmol/L (2.255 to 4.238 mg/L), current density 0.6 mA/cm2, and OGLs-to-U (VI)
212
mole ratio 3:1
213
Alizarin S, the best organic ligand for cooperative chelation in the efficient interception and
214
precipitation of uranium (VI) from water by iron-electrocoagulation, was selected for the next
ACS Paragon Plus Environment
Page 11 of 33
Environmental Science & Technology
215
steps of testing. Critical parameters that affect the uranium precipitation, including solution pH,
216
applied current density, OGLs-to-U(VI) mole ratio, and initial uranium concentration were
217
comprehensively investigated, and the results are presented in Figure 3. As depicted in Figure 3a,
218
the optimum solution pH was 6.0, which was consistent with the experimental results in Figures 1
219
and 2. A higher applied current density would increase the uranium removal efficiency (Figure 3b),
220
which was 60.29%, 73.22%, 90.96%, and 98.50% at the current density of 0.6, 0.8, 1.0, and 1.4
221
mA/cm2, respectively. In the presence of Alizarin S, the iron-electrocoagulation method could
222
effectively remove uranium to meet the discharge standard, by using a low cell voltage (2.2 V for i
223
= 1.0 mA/cm2 and 2.6 V for 1.4 mA/cm2) and a short treatment time. Therefore, both high
224
uranium removal efficiency and low treatment cost could be achieved with the proposed
225
iron-electrocoagulation method when combined with the OGLs cooperative chelation.
226
An appropriate amount of added OGLs is necessary to reach a satisfactory uranium removal
227
efficiency, by improving the uranium interception and reducing the Zeta potential of the growing
228
flocculation precursor. As shown in Figure 3c, when the OGLs-to-U(VI) mole ratio was small
229
(3:1) means that the
231
uranyl ion would be encapsulated by excess organic ligands, producing a higher net negative
232
charge. As a result, a higher input cell voltage is required to compress the newly formed double
233
layer structure. Meanwhile, the rubber and bonded organic ligands would affect the settlement
234
characteristics of the generated flocs. The OGLs-to-U(VI) mole ratio of 3:1 was found to be the
235
optimal for uranium iron-electrocoagulation precipitation. At this ligand mole ratio, current
236
density of 0.6 mA/cm2, initial uranium concentration of 11.36 µmol/L (3.067 mg/L), and solution
ACS Paragon Plus Environment
Environmental Science & Technology
237
pH of 6.0, the uranium removal efficiency reached 99.65% (Figure 1c). The change of Fe3+
238
concentration with Alizarin S as OGL under various pH conditions in the iron-electrocoagulation
239
system is provided in SI, Table S2. At low pH values, a high Fe3+ concentration was detected, and
240
it decreased dramatically with increasing of the solution pH value. At pH = 6.0, a very low Fe3+
241
concentration was detected in the effluent, indicating that Fe3+ pollution can be avoided.
242
The initial uranium concentration affects its removal efficiency and determines the bulk
243
electrolysis time needed to achieve an acceptable effluent concentration. Figure 3d shows that the
244
uranium removal efficiency decreases with increasing initial uranium concentration, being 60.29%,
245
49.95%, 32.13%, and 24.95% for the respective initial uranium concentrations of 12.57, 27.31,
246
38.80, and 53.87 µmol/L (3.395, 7.375, 10.475, and 14.544 mg/L), under the operating conditions
247
of solution pH 3.0, current density 0.6 mA/cm2, and OGLs-to-U(VI) mole ratio of 3:1. The results
248
revealed that uranium precipitation with the iron-electrocoagulation method was an energy reigned
249
electrochemical reaction, and the amount of the formed flocculation precursor (iron oxides/
250
hydroxides) determined the uranium removal efficiency. A high initial uranium concentration
251
should be accompanied by a high current density. After the intercalation of organic ligands, the
252
uranium precipitation process was found to also follow the second-order kinetic model (SI, Figure
253
S3-6 and Table S1).
ACS Paragon Plus Environment
Page 12 of 33
Page 13 of 33
Environmental Science & Technology
4
a)
pH=3.0 pH=5.0 pH=6.0 pH=7.0 pH=9.0
3
2
1
0
Uranium concentration (mg/L)
Uranium concentration (mg/L)
4
b)
2
i=0.6 mA/cm 2 i=0.8 mA/cm 2 i=1.0mA/cm 2 i=1.4 mA/cm
3
2
1
0
0
4
8
16
20
4
8
c)
mOLGs:U=1:1
3.5
mOLGs:U=3:1 mOLGs:U=6:1
3.0
mOLGs:U=9:1 2.5 2.0 1.5
Uranium concentration (mg/L)
16
12
Time (min)
16
20
24
d) c0=14.544 mg/L
12
c0=10.475 mg/L
8
c0=7.375 mg/L 4 c0=3.395 mg/L 0
1.0
254
0
24
Time (min)
4.0
Uranium concentration (mg/L)
12
0
4
8
12
Time (min)
16
20
24
0
4
8
12
16
20
24
Time (min)
255
Figure 3 Uranium concentration on dependent of reaction time with iron-electrocoagulation in presence of Alizarin
256
S at different pH (a) (i=0.6 mA/cm2, OGLs-to-U(VI)=3:1, c0=11.11-18.52 µmol/L (3.0-5.0 mg/L)), current density
257
(b) (pH 3.0, OGLs-to-U(VI)=3:1, c0=11.11-18.52 µmol/L (3.0-5.0 mg/L)), different OGLs-to-U(VI) molar ratio (c)
258
(pH 3.0, i=0.6 mA/cm2, c0=11.11-18.52 µmol/L (3.0-5.0 mg/L)), and initial uranium concentration 0 to 55.56
259
µmol/L (0 to 15.0 mg/L) (d) (pH 3.0, i=0.6 mA/cm2, OGLs-to-U(VI)=3:1)
260
Elimination of Organic Ligand Pollution. Figure 4 shows that adding the OGLs could raise the
261
organic pollution index, with the chemical oxygen demand (CODCr) value ranging from 40 to 80
262
mg/L. Fortunately, the introduced organics would also be removed during the subsequent
263
iron-electrocoagulation process. Hydrophilic macromolecule such as Alizarin S and EDTA (with
264
hydrophilic hydroxyl and carboxyl groups, respectively) present higher precipitation efficiency
265
than the hydrophilic small molecule IDA and the hydrophobic macromolecule of PANI. The COD
266
removal efficiency with IDA, PANI, EDTA, and Alizarin S as organic ligands were 82.97%,
ACS Paragon Plus Environment
Environmental Science & Technology
Page 14 of 33
267
71.61%, 88.97%, and 86.89%, respectively. The different CODCr removal for different organic
268
ligands would be ascribed to their affinity and nucleation-promotion capacity with the flocculation
269
precursors generated in the iron-electrocoagulation system. The hydrophilic substances would be
270
easily captured and encapsulated in the crystallized ferrite species. In other words, the hydrophilic
271
groups have an intrinsic affinity for the iron hydroxides. The larger molecular weight and fine
272
hydrophilicity of Alizarin S that endows adequate flocculation reactions in iron-electrocoagulation
273
system also facilitate its uranium precipitation in U-Alizarin S chelates.
274
a)
b) COD removal efficiency (%)
120 100 80 60 40 20 0 IDA
PANI
EDTA
Alizarin S
OGLs species
275 276
Figurer 4 The COD value (a) and removal efficiency (b) during uranium iron-electrocoagulation with different
277
organic ligands species. Experimental condition: pH 6.0, current density 0.6 mA/cm2, OGLs-to-U(VI) mole ratio
278
3:1, initial uranium concentration 11.11 to 18.52 µmol/L (3.0-5.0 mg/L)
279
Mechanism of Uranium Precipitation in Iron-electrocoagulation System. The precipitated
280
flocs in iron-electrocoagulation system were collected for the following three cases under the
281
initial uranium concentration of 11.11–18.52 µmol/L (3.0–5.0 mg/L): (1) with no uranium and
282
OGLs, (2) with uranium but no OGLs, and (3) with uranium and Alizarin S as OGL. The flocs
ACS Paragon Plus Environment
Page 15 of 33
Environmental Science & Technology
283
were characterized with SEM, elemental mapping, EDS, and TEM methods for their
284
microstructure observation and elemental composition detection. XRD, FT-IR, and XPS
285
techniques were employed to explore the corresponding precipitation mechanisms. As shown in
286
Figure 5a, d, and g, the colloidal aggregates of pure iron oxides/hydroxides were flake-shaped,
287
fully crystallized nanoparticles with size of appropriately 26.2 nm. The fine crystals on the
288
surfaces were sodium sulfate granules separated out during the bulk electrolysis. Once the
289
uranium participated in the iron-electrocoagulation reactions, crystalline uranium composites were
290
observed on the surface and edge of the particles of the iron oxides and hydroxides (Figure 5b),
291
and the morphology of the precipitated flocs became disorganized with a defective lattice structure
292
and marginal fault (shown in Figure 5b, e, and h). The size of the formed nanoparticles decreased
293
to 8.6 nm. After the intercalation of Alizarin S, the SEM image (Figure 5c) showed that fine
294
nanoparticles of uranium composites were gathered on the particle surface and edge of pure iron
295
oxides and hydroxides, the lattice structure of the flocs became increasingly disordered, and the
296
size of the formed nanoparticles further decreased to 4.7 nm. Uranium composites were also found
297
as fine nanoparticles on the surface and edge of iron oxides and hydroxides when IDA, PANI, or
298
EDTA was used as organic ligands in the iron-electrocoagulation system, with the respective
299
nanoparticle size of 4.7, 2.6, and