Subscriber access provided by University of Florida | Smathers Libraries
Article
In situ quantification of [Re(CO)3]+ by fluorescence spectroscopy in simulated Hanford tank waste Shirmir D. Branch, Amanda D. French, Amanda M. Lines, Brian M Rapko, William R. Heineman, and Samuel A. Bryan Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b04222 • Publication Date (Web): 14 Dec 2017 Downloaded from http://pubs.acs.org on December 21, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 24
Environmental Science & Technology
1
In situ quantification of [Re(CO)3]+ by fluorescence
2
spectroscopy in simulated Hanford tank waste
3
Shirmir D. Branch,a,b Amanda D. French,b Amanda M. Lines,b Brian M. Rapko,b William R.
4
Heineman,a* Samuel A. Bryanb*
5
a
Department of Chemistry, University of Cincinnati, Cincinnati, OH, 45221-0172, USA
6
b
Pacific Northwest National Laboratory, Richland, WA, 99352, USA
7
ABSTRACT
8
A pretreatment protocol is presented that allows for the quantitative conversion and subsequent
9
in situ spectroscopic analysis of [Re(CO)3]+ species in simulated Hanford tank waste. In this test
10
case, the non-radioactive metal rhenium, is substituted for technetium (Tc-99), a weak beta
11
emitter, to demonstrate proof of concept for a method to measure a non-pertechnetate form of
12
technetium in Hanford tank waste. The protocol encompasses adding a simulated waste sample
13
containing the non-emissive [Re(CO)3]+ species to a developer solution that enables the rapid,
14
quantitative conversion of the non-emissive species to a luminescent species which can then be
15
detected spectroscopically. The [Re(CO)3]+ species concentration in an alkaline, simulated
16
Hanford tank waste supernatant can be quantified by the standard addition method. In a test case,
17
the [Re(CO)3]+ species was measured to be at a concentration of 38.9 µM, which was a
18
difference of 2.01% from the actual concentration of 39.7 µM.
ACS Paragon Plus Environment
1
Environmental Science & Technology
19
Page 2 of 24
INTRODUCTION
20
The Hanford Site in southeastern Washington State is one of the largest and most costly
21
remediation efforts in the United States. The Site is home to 9 decommissioned nuclear reactors
22
and numerous associated processing facilities, including 177 underground nuclear waste storage
23
tanks containing approximately 55 million gallons (2.1 × 105 m3) of waste generated as a result
24
of decades of plutonium production.1 Consequently, it has been declared a major EPA Superfund
25
site that is undergoing cleanup. One aspect of the remediation efforts includes the separation of
26
low- and high-level activity waste.2 The need to characterize and monitor various constituents of
27
interest in these underground storage tanks presents a major scientific challenge, particularly
28
concerning moving high activity constituents, such as water-soluble radionuclides, prior to
29
immobilization. Current methods of analysis are hazardous, expensive, and time consuming.3, 4
30
These methods typically require extensive sample collection and preparation, putting workers at
31
risk of exposure, as well as lengthy analysis and data interpretation. A more efficient approach
32
might be to use sensors to perform rapid, sensitive, and economic in situ analyses for key
33
constituents. A major issue for the environmental remediation of the Hanford site is the ability to
34
measure for specific contaminants of interest given the chemical complexity, harsh radiological
35
environment, and limited tank access complicating well-established laboratory-based analytical
36
techniques employed to analyze the wastes. This paper continues our interest in developing
37
sensors based on optical spectroscopy, electrochemistry and selective partitioning for the direct
38
measure of specific target analytes within the waste.5
39
Technetium (Tc) is one such constituent where an analytical method exists, but a rapid, direct
40
sensor does not.6 Technetium is not found in substantial quantities in nature. However, the
41
isotope
99
Tc is a byproduct of the thermal nuclear fission of
235
U,
233
U, and
239
Pu (at yields of
ACS Paragon Plus Environment
2
Page 3 of 24
Environmental Science & Technology
42
6.1%, 5.0%, and 6.2%, respectively),7, 8 and therefore is generated in large quantities at nuclear
43
sites. 99Tc accounts for ~100% of all Tc isotopes sources. The total 99Tc content at the Hanford
44
Site approximates to 2000 kg (~36,000 Ci), of which ~4% has been lost to the environment.9
45
Although 99Tc exhibits only a weak β- decay (0.292 keV), it is of environmental concern for two
46
reasons: (1) it has a half-life of 2.13 × 105 years,7 and (2) its most abundant environmental
47
species, pertechnetate, TcO4-, migrates quickly with groundwater.10 Pertechnetate has a very low
48
soil retention and a high solubility in water. These properties allow technetium, after leaking
49
from the underground storage tanks, to pass quickly through soil into subsurface waters.11, 12
50
One of the basic necessities in Tc remediation is to meet regulatory requirements for disposal
51
of Tc found in US Department of Energy (USDOE) waste streams and released into the
52
environment. Current techniques to analyze technetium include ion exchange chromatography
53
(IC),13 mass spectrometry (MS),3 capillary electrophoresis (CE),14 coulometric titration,15 surface
54
enhanced Raman scattering (SERS),16 and extended X-ray absorption fine structure (EXAFS).17
55
These techniques are often limited for routine analytical use by arduous sample treatment and
56
long processing times. Many of these techniques also lack the sufficient selectivity to identify the
57
Tc(CO)3+ species that this work is interested in, which presently inhibits the remediation of total
58
technetium from tank waste.
59
Several significant uncertainties remain regarding the understanding and modeling of the fate 99
99
60
and speciation of
61
Hanford tank wastes using ion-exchange or ion-pair extraction processes specific to
62
pertechnetate were only partially successful due to the presence of a significant fraction of other
63
valence and complexed forms of
64
reported evidence of a Tc(I)-tricarbonyl-type compound present in the waste.17 Under tank
Tc in Hanford tank waste. Previous attempts to remove
99
Tc from selected
Tc in the waste supernatants. A study into this problem
ACS Paragon Plus Environment
3
Environmental Science & Technology
Page 4 of 24
65
conditions, the tricarbonyl species is expected to react with constituents within the waste,
66
forming a [Tc(CO)3(L)3]n- complex, where (L)3 represents a multidentate ligand binding to the
67
metal center, such as citrate, oxalate, and gluconate. The presence of the non-pertechnetate
68
species (which has been found in select Hanford tank supernatants at concentrations ranging
69
from 2% – 60% of total Tc) has hampered the selective movement of Tc high level waste
70
streams prior to immobilization.9 It is also believed that the [Tc(CO)3(L)3]n- species have the
71
potential to leak from the tanks into the underlying vadose zone and groundwater. Once it
72
reaches this point, the species can change into the more prevalent TcO4- form, which has a high
73
mobility rate in the arid soil and groundwater, further impacting the environment around the
74
Hanford Site. 11, 12 The objective of this work is to develop a sensor for the direct detection of the
75
[TcI(CO)3]+ species that will help reduce the uncertainties in the fate and speciation of Tc in
76
Hanford waste storage tanks prior to immobilization.
77
Optical spectroscopy is a quick non-destructive method that would be useful for detection of
78
the [TcI(CO)3]+ species. Previously, the quantitative measurement of various Tc species using
79
both absorption2 and fluorescence spectroscopy,18 as well as the luminescence-based
80
spectroelectrochemical detection of Tc(II) species, both in solution19 and in film,20 have been
81
demonstrated. One challenge with detecting the [TcI(CO)3(L)3]n- species is that it does not have a
82
unique signature using routine optical spectroscopic techniques and is indistinguishable from
83
other constituents stored in the waste tanks. To overcome this challenge, a sensing method that
84
converts the non-emissive [TcI(CO)3(L)3]n- species into a luminescent species that would be
85
detectable at the concentrations found in tank waste, which are estimated to be in the range of 60
86
µM, will be developed. For optical detection at such low concentrations, fluorescence would be a
87
more suitable choice than other methods, such as UV-vis absorption spectroscopy. Absorption
ACS Paragon Plus Environment
4
Page 5 of 24
Environmental Science & Technology
88
spectroscopy is limited by several factors, including a high sample concentration and a long path
89
length required for signal collection, due to the relatively low molar extinction coefficient of the
90
analyte. Absorption spectroscopy is also limited by selectivity, in that many other species present
91
in Hanford tank supernatants also absorb light in the UV-vis region. Fluorescence spectroscopy
92
has the benefits of higher sensitivity and selectivity than absorption. Detection using
93
fluorescence can achieve detection limits at least 1,000-fold lower than absorption spectroscopy.
94
Fluorescence is also more selective in that while many of the constituents in tank waste absorb
95
light, far fewer also emit light. Selectivity is further increased in that very few constituents, if
96
any, both excite and emit light at the same wavelengths as the target species.
97
The direct reaction of [TcI(CO)(L)3]n- with bidentate and tridentate ligands has been
98
established under conditions (neutral and basic pH, at room temperature, saline) suitable for
99
radiotherapeutic applications.21-23 By complexing the Tc(I)-tricarbonyl species with sensitizing
100
ligands such as 2,2′-bipyridine (bpy), 1,10′-phenanthroline (phen), or functionalized bpy and
101
phen ligands, we propose to convert the [TcI(CO)3(L)3]n- species into optically emissive
102
complexes with the formula [Tc(CO)3(LᴖL)(L)]n- as shown in Figure 1, where LᴖL is a bidentate
103
sensitizing ligand.
104 105
Figure 1. Schematic of conversion of [TcI(CO)(L)3]n- to [Tc(CO)3(LᴖL)(L)]n-; LᴖL = bpy.
106
For initial laboratory testing, rhenium was used as the surrogate of technetium to study in
107
simulated tank waste. The conversion of [Re(CO)3(H2O)3]+ into a luminescent species has been
108
well characterized in the interest of radiopharmaceutical imaging.24,
25
A range of Re(I)
ACS Paragon Plus Environment
5
Environmental Science & Technology
Page 6 of 24
109
complexes, based on the Re(I)-tricarbonyl core, have previously been shown to be emissive,26
110
and are used in this work as a non-radioactive surrogate for the Tc(I)-tricarbonyl system.
111
Previous work has shown that the luminescence from technetium and rhenium, second- and
112
third-row congeners, containing the d2 metal-oxo core,
113
(where M = Re or Tc; and dmpe is bis-1,2-(dimethylphosphino)ethane)), 19, 29-31 are comparable
114
with respect to the lifetimes and electronic states of emission. In this study, a number of Re(I)-
115
carbonyl
116
[Re(CO)3(bpy)(H2O)]+, to serve as the standard species for comparison to the product formed in
117
the proposed conversion method. This conversion, or pretreatment method, starts by dissolving
118
the non-emissive [Re(CO)3]+ species in a solution matrix, either with or without simulated tank
119
waste. The pretreatment method performs the following elements: 1) dissolves the waste matrix
120
containing the non-emissive [Re(CO)3]+ species into a developer solution containing a high
121
concentration of sensitizing ligand, 2) introduces a high dilution factor to minimize matrix
122
effects from waste sample, and 3) is designed to optimize the conversion of the non-emissive
123
[Re(CO)3]+ species into the target luminescent species. The reaction is allowed to occur at a
124
chosen temperature for a short amount of time. Finally, the sample is excited and the
125
fluorescence is measured. We have purposely designed our methodology based on the
126
preparation and measurement of fluorescent complexes in order to decrease the LOD as well and
127
enhance the selectivity of target analyte detection. Fe and Cr are two competing metals known
128
to be present in actual tank waste samples, and whose complexation with the sensitizing ligand,
129
2,2′-bipyridyl (bpy) is known. For this reason, we have chosen to use a pretreatment method
130
containing a sensitizing ligand in large excess concentration sufficient to bind to the target Re (or
131
Tc) metal as well as any other competing metals. Using fluorescence detection instead of
complexes
have
been
synthesized,
27, 28
or the d5 [M(dmpe)3]2+ complexes
including
[Re(CO)3(H2O)3]+
and
ACS Paragon Plus Environment
6
Page 7 of 24
Environmental Science & Technology
132
absorption spectroscopy is extremely useful in this situation, as fluorescence is more selective
133
and sensitive for conditions such as these Cr-bpy and Fe-bpy species do not have the same
134
spectroscopic signature as the target Re-bpy, or the Tc-bpy species.
135
The quantity of [Re(CO)3]+ in the simulated waste samples is determined using the accepted
136
method of standard addition.32 The application of the standard addition method in conjunction
137
with the proposed pretreatment method greatly reduces the actions of interfering species – by
138
way of target species conversion and spectroscopic signature – in both simulated and real waste
139
samples. Preliminary studies have shown that this conversion can be successfully applied to
140
[Re(CO)3]+ and [Tc(CO)3]+ in simulated waste samples (Figure 2A), as well as [Tc(CO)3]+ in an
141
actual Hanford waste sample (Figure 2B). All three samples were treated as described above,
142
using a developer solution containing a high concentration of 2,2′-bipyridyl in acetonitrile. This
143
information indicates that the proposed method presents a convenient method for the detection of
144
[Tc(CO)3]+ species both in simulated waste and actual tank waste samples containing .
(A)
(B)
145 146
Figure 2. Measurement of [Re(CO)3]+ and [Tc(CO)3]+ in simulated and actual Hanford waste
147
samples using the Pretreatment Protocol Solution consisting of 0.125 M bpy in CH3CN. (A)
148
Excitation (red, dashed line) and emission (red, solid line) of [Re(CO)3]+ in simulated waste;
ACS Paragon Plus Environment
7
Environmental Science & Technology
Page 8 of 24
149
excitation (blue, dashed line) and emission (blue, solid line) of [Tc(CO)3]+ in simulated waste;
150
(B) emission of [Tc(CO)3]+ in simulated waste (blue, solid line) and an actual tank waste sample
151
(green, solid line). Actual tank waste was taken from tank 241-AN-102 at the Hanford Site.
152
EXPERIMENTAL SECTION
153
Chemicals and materials
154
The following chemicals and solvents were obtained from Sigma-Aldrich (unless otherwise
155
indicated) and used without further purification: dirhenium decacarbonyl (98%); 2,2′-bipyridyl
156
(≥99%); bromine (≥95%); dichloromethane (anhydrous, ≥99.8%); acetonitrile (anhydrous,
157
99.8%); methanol (≥99.8%; Fisher); diethyl ether (anhydrous, ≥99.0%). Aqueous solutions were
158
prepared with deionized water (D2798 Nanopure system; Barnstead, Boston, MA).
159
Instrumentation
160
Emission spectra were collected using a Horiba Jobon Yvon Fluorolog III fluorimeter
161
equipped with a 450-W xenon lamp, double-emission monochromator blazed at 500 nm, and a
162
single-excitation monochromator blazed at 300 nm, and an InSpectrum 150 spectrometer-CCD,
163
using SpectraSense data-acquisition software. A 405 nm laser source was used for excitation
164
with the InSpectrum 150 spectrometer. Signal integration times were 999 msec using a 2 mm slit
165
width using a 600-gr/mm grating blazed at 500 nm.
166
Preparation of Re-carbonyl complexes
167
The preparation of the target [Re(CO)3]+ species begins with Re2(CO)10, which is reacted with
168
elemental bromine to form the complex Re(CO)5Br (see Figure 3).33 The pentacarbonyl complex
169
is allowed to react with water under reflux conditions to yield the aquo complex,
170
[Re(CO)3(H2O)3]+ (1). This complex is then reacted with a sensitizing ligand, such as bpy, to
171
form the luminescent [Re(CO)3(bpy)(X)]+ (2) species (X = H2O or CH3OH). Complex 1 can also
ACS Paragon Plus Environment
8
Page 9 of 24
Environmental Science & Technology
172
be added to a waste simulant to prepare [Re(CO)3(L)3]n-, where R is some organic complexant,
173
such as oxalate. This serves as an analogue for the non-pertechnetate technetium species believed
174
to be within the tank supernatant.
175
[Re(CO)3(H2O)3]Br (1).34 Approximately 1.2 mmol Re(CO)5Br was added to a round-
176
bottomed flask, to which 20 mL of DI water was added. The starting material did not dissolve in
177
room-temperature water. The solution was allowed to reflux for at least 24 hours at 100°C.
178
Periodically, the condenser was rinsed as the starting material deposited at the bottom of the
179
condenser. Upon completion of the reflux, the solvent was removed using rotary evaporation.
180
The product remaining was a white solid and stored for later use.
181
[Re(CO)3(bpy)(X)]Br (2).35 Approximately 1 mmol [Re(CO)3(H2O)3]Br was added to a
182
round-bottomed flask, to which 40 mL of methanol was added. The solution was heated to 65°C,
183
while stirring. More solvent was added, as necessary, so that all of the [Re(CO)3(H2O)3]Br was
184
dissolved before the ligand addition. Approximately 1.1 mmol of the sensitizing ligand was
185
added to the flask. A color change was observed immediately upon ligand addition. The solution
186
was allowed to reflux for approximately 5 hours at 65°C. The solution was then allowed to cool
187
back to room temperature. If no precipitate was observed, the solvent was removed using rotary
188
evaporation. If a precipitate was observed, the sample was filtered and rinsed with diethyl ether.
189
The product [Re(CO)3(bpy)(X)]Br was dried and stored for use (where X = CH3OH). Other
190
solvates (where X = H2O or CH3CN) were prepared by substituting water or acetonitrile in place
191
of methanol.
ACS Paragon Plus Environment
9
Environmental Science & Technology
Page 10 of 24
192 193
Figure 3. Synthesis schematic for [Re(CO)3(bpy)(X)]+.
194
Preparation of simulated tank waste supernatant
195
The simulated waste supernatant is based on a generic Hanford tank waste supernatant
196
simulant composition used for flowsheet development testing.36 This simulant was chosen for its
197
high alkalinity, high ionic strength characteristics, the presence of interfering metal species, and
198
the presence of organic complexants. Table 1 lists the components of the simulated waste.
199
Table 1. Composition of Hanford Waste Supernatant simulant. Component
Chemical Formula
Concentration (g/L)
Sodium oxalate
Na2C2O4
1.9
Aluminum nitrate
Al(NO3)3•9H2O
78 (60% solution of Al(NO3)3•9H2O)
Sodium phosphate
Na3PO4•12H2O
25
Sodium sulfate (anhydrous)
Na2SO4
25
Sodium nitrate
NaNO3
104
Sodium hydroxide (50% solution)
NaOH
104 (50% solution of NaOH)
Sodium nitrite
NaNO2
35
Sodium carbonate (anhydrous)
Na2CO3
58.57
ACS Paragon Plus Environment
10
Page 11 of 24
Environmental Science & Technology
200 201
RESULTS AND DISCUSSION
202
Spectroscopic signature of [Re(CO)3(bpy)(X)]+
203
To establish the spectroscopic signature of the converted Re-tricarbonyl complexes by
204
pretreatment, the excitation and emission spectra were acquired for the luminescent Re species
205
synthesized by the standard route. The solvation of the [Re(CO)3(bpy)(X)]+ complex is verified
206
based on the known emission maximum for the aquated and acetonitrile complex: X = H2O, λmax
207
= 575 nm; X = CH3CN, λmax = 595 nm. Complex 2 (where X = CH3CN) excites at 396 nm and
208
fluoresces at 595 nm (Figure S1). The emission of complex 2 was measured at concentrations
209
ranging from 0 – 1 mM (Figure 4A). The linear range of the emission at 595 nm is plotted
210
against the concentration of 2 (Figure 4B). The limit of detection for [Re(CO)3(bpy)(CH3CN)]+
211
was 16.7 nM. The detection limit for rhenium was calculated using the equation:
212
=
∗
,
(1)
213
where s is the standard deviation for the noise measurements, and m is the slope of the linear
214
region of the plot. The full concentration range for the concentration-emission profile of complex
215
2 is shown in Figure S2.
ACS Paragon Plus Environment
11
Environmental Science & Technology
Page 12 of 24
emission intensity
(A)
max emission
(B)
216 217
Figure 4. Concentration-emission profile of [Re(CO)3(bpy)(CH3CN)]+ in acetonitrile. (A) Emission
218
spectra of [Re(CO)3(bpy)(CH3CN)]+ in acetonitrile; excitation at 405 nm. (B) Emission at 595 nm vs.
219
concentration of [Re(CO)3(bpy)(CH3CN)]+ (linear range). The equation for the line is y = 6.307e+09 x +
220
1168 (R2 = 0.9998).
221
Conditions of Pretreatment Protocol: [Re(CO)3]+ complex conversion
222
The purpose of the pretreatment protocol is to provide an alternative method of detection that
223
is quicker and less hazardous than other techniques currently being used to analyze tank waste
224
samples. The protocol comprises adding a tank sample (or simulated waste), to a developer
225
solution that enables the conversion of the target analyte into a rhenium (or technetium, in the
ACS Paragon Plus Environment
12
Page 13 of 24
Environmental Science & Technology
226
case of actual waste) complex that can be measure spectroscopically. The pretreatment protocol
227
is designed to accomplish several things simultaneously:
228 229 230 231 232 233
1. The developer solution contains a diamine sensitizing ligand in high enough concentration that allows for binding to the target [Re(CO)3]+ species. 2. The sensitizing ligand can be chosen based on its affinity for the target [Re(CO)3]+ species over other competing ligands in a waste sample. 3. The developer solution can also adjust the pH and/or ionic strength of the waste sample to diminish the interference of competing metals.
234
4. The developer solution is used at a volume to allow for high dilution of the waste
235
sample in order to diminish the competition from other organic ligands within the
236
waste matrix.
237 238 239
5. The waste/developer matrix can be heated to encourage quick formation of the target [Re(CO)3(LᴖL)(L)]+ species. 6. The solvent
in
the
developer solution
is
able to
dissolve the formed
240
[Re(CO)3(LᴖL)(L)]+ complex allowing for ease of measurement and simultaneously
241
enabling the precipitation of some interfering salt species.
242
A variety of adjustments were tested to ensure the final developer solution met the acceptable
243
criteria described above. Some parameters included: adjusting the pH of the simulated waste
244
sample before addition to the developer solution; testing a variety of aqueous and nonaqueous
245
solvents for the developer solution; adjusting the choice and concentration of the sensitizing
246
ligand in the developer solution, including mixed solvent solutions; optimizing the volume
247
dilution ratio of the simulated waste sample in the developer solution; and adjusting the heating
248
temperature and time to allow for species conversion. The decision to use 2,2′-bipyridyl in
ACS Paragon Plus Environment
13
Environmental Science & Technology
Page 14 of 24
249
acetonitrile was based on reducing the time/number of steps to pretreat a waste sample for
250
spectroscopic analysis. The simulated waste sample is added in a 1:200 volume dilution to the
251
developer solution. The chosen solvent for the developer solution is sufficient to keep the
252
sensitizing ligand, the target [Re(CO)3]+ species, and the converted [Re(CO)3(LᴖL)(L)]+ complex
253
in soluiton at high enough concentrations.
254
Pretreatment standard calibration
255
A solution of [Re(CO)3]+ in water was prepared, of which aliquots were added in increasing
256
amounts from 0 – 50 µL to 2 mL aliquots of the developer solution containing 0.125 M bpy in
257
CH3CN. The solutions were heated at 30°C for 10 min. The solutions were then allowed to cool
258
to room temperature, and the fluorescence was measured. The maximum fluorescence occurred
259
at 563 nm. This protocol was repeated with heating of the solution at either 40 or 50°C. Figure 5
260
shows the emission spectra at various concentrations of [Re(CO)3]+ added and a calibration plot
261
of the maximum emission at all three temperatures vs. the concentration of [Re(CO)3]+. Heating
262
at 40°C is shown to have the highest sensitivity, with a detection limit of 38.4 nM (Figure 5A).
263
Heating at 30°C and 50°C yielded detection limits of 42.3 nM and 42.0 nM, respectively (Figure
264
5B). Though it has been shown that the complete conversion of the non-emissive [Re(CO)3]+
265
species to the luminescent complex can occur within 30 min at 40°C,37 there was no significant
266
difference in the detection limit between heating at 10 min as opposed to 30 min. The in situ
267
detection limit of 38.4 nM is 56.5% higher than that of the complex synthesized by standard
268
route (16.7 nM). However, the fluorescence of the standard synthesized complex was measured
269
using a more selective detector in order to fully determine the excitation and emission
270
characteristics that set the basis for our pretreatment protocol. In either case, the detection limit
ACS Paragon Plus Environment
14
Page 15 of 24
Environmental Science & Technology
271
calculated using this protocol falls well under the expected concentration of [Tc(CO)3]+ species
272
in the Hanford tank waste estimated to be ~60 µM.
(A)
(B) 273 274
Figure 5. Pretreatment of [Re(CO)3]+ in water using 0.125 M bpy in CH3CN. (A) Emission spectra after
275
heating at 40°C (405 nm excitation). (B) Emission at 563 nm vs. [Re(CO)3]+ concentration; 30°C
276
regression line: y = 7.960 × 108 x + 186.2 (R2 = 0.9962); 40°C regression line: y = 8.789 × 108 x + 490.2
277
(R2 = 0.9973); 50°C regression line: y = 8.028 × 108 x + 249.0 (R2 = 0.9957).
278
The maximum emission intensity of the pretreated samples was shifted about 30 nm to higher
279
energy compared to the standard synthesis method, which could be due to the water environment
280
that the [Re(CO)3]+ species was in upon being introduced to the developer solution. The key
281
differences in the reaction conditions between this pretreatment method and the standard
ACS Paragon Plus Environment
15
Environmental Science & Technology
Page 16 of 24
282
synthesis method is the concentration of the sensitizing ligand and the time allowed for complex
283
formation. In the standard method, the ligand and metal are added in equal mole fractions and
284
any impurities are removed from the final product before characterization studies take place. The
285
standard synthesis process also involves more purification steps than would be required when
286
handling a real waste sample. In this protocol, the signal of the free ligand does not interfere with
287
the signal from the target [Re(CO)3(bpy)(H2O)]+ species.38
288
Pretreatment in simulated waste supernatant
289
A solution of [Re(CO)3]+ in water was added to a simulated waste supernatant to form a matrix
290
emulating a real waste sample. Aliquots of the matrix were added in increasing amounts from 0 –
291
50 µL to 2 mL aliquots of the developer solution containing 0.125 M bpy in CH3CN. The
292
solutions were then heated at 40°C for 10 min. The solutions were cooled to room temperature,
293
then the fluorescence was measured. Figure 6A shows the fluorescence of each solution. The
294
emission at 635 nm is plotted against the concentration of [Re(CO)3]+ in solution (Figure 6B),
295
showing a linear concentration-emission response, with a detection limit of 5.17 µM, well below
296
the concentration of [Tc(CO)3]+ reported to date in actual waste.9 Compared to the pretreatment
297
of Re(CO)3+ in water (Figure 5), the maximum emission of the [Re(CO)3]+ complex formed in
298
the simulated waste solution is shifted, as well as the intensity being reduced by a factor of ~50
299
(Figure 6). The components in the simulated waste were tested for quenching of the emission
300
(Figure S3) , results shown in Figure S3. The waste species including sodium salts of nitrate,
301
nitrite, sulfate, oxalate, and aluminum nitrate did not quench the emission signal of the Re-ligand
302
complex, even though these potential quenchers were added at significant levels relative to their
303
respective concentrations in actual waste solutions (Figure S3A). Sodium phosphate and sodium
304
carbonate did diminish the emission (Figure S3B) to approximately the same magnitude seen in
ACS Paragon Plus Environment
16
Page 17 of 24
Environmental Science & Technology
305
the simulated waste measurements, presumably due to chemical interaction with the Re center,
306
since the wavelength maximum emission was also shifted in measurements containing these
307
constituents. The linear concentration-emission response for the [Re(CO)3]+ in waste simulant
308
(Figure 6) with zero intercept, indicates the emissive complex observed is due to the formation of
309
the Re-carbonyl-bpy complex. Furthermore, the proportional response of emission intensity to
310
changes in Re concentration indicate this is a viable and successful route for sensing and
311
quantifying the target Re complex.
(A)
(B) 312 313
Figure 6. Measurement of [Re(CO)3]+ in waste simulant using the Pretreatment Protocol Solution
314
consisting of 0.125 M bpy in CH3CN. (A) Emission spectra at 405 nm excitation. (B) Emission at 635 nm
315
vs. [Re(CO)3]+ concentration. The equation of the line is y = 1.642 × 107 x + 1.527 (R2 = 0.9902).
ACS Paragon Plus Environment
17
Environmental Science & Technology
316
Page 18 of 24
Quantification of [Re(CO)3]+ in simulated waste through the use of standard addition
317
For the determination of [Re(CO)3]+ in simulated waste, the accepted method of standard
318
addition was used. A solution of [Re(CO)3]+ in water was added to a simulated waste supernatant
319
to form the matrix emulating a real waste sample. This served as the “unknown” matrix. 10 µL
320
aliquots of the “unknown” were added to 2 mL aliquots of the developer solution containing
321
0.250 M bpy in CH3CN. The simulated waste/developer matrix was spiked with a standard,
322
consisting of a known concentration of [Re(CO)3]+ in water, in increasing amounts over a range
323
of 0 – 50 µL. The spiked samples were heated at 50°C for 30 min. The solutions were cooled to
324
room temperature, then the fluorescence was measured. Figure 7A shows the fluorescence of
325
each solution. The emission at 635 nm is plotted against the concentration of [Re(CO)3]+ in
326
solution (Figure 7B). The concentration of [Re(CO)3]+ determined by the standard addition
327
method was 38.9 µM, which compares favorably to the actual value (39.7 µM) and results in a
328
2.01% difference from the “unknown” concentration.
ACS Paragon Plus Environment
18
Page 19 of 24
Environmental Science & Technology
(A)
(B)
329 330
Figure 7. Standard addition measurement of [Re(CO)3]+ in waste simulant using the Pretreatment
331
Protocol Solution consisting of 0.250 M bpy in CH3CN. (A) Emission spectra at 405 nm excitation. (B)
332
Standard addition plot of [Re(CO)3]+ in waste simulant; emission at 635 nm vs. [Re(CO)3]+ standard
333
concentration. The equation of the line is y = 5.503 × 106 x + 214.3 (R2 = 0.9954).
334
Based on these results using [Re(CO)3]+ in simulated waste, a proposed method for the
335
convient, direct detection of [Tc(CO)3]+ within tank waste is successfully demonstrated. Further
336
steps will involve optimizing this protocol as necessary for the detection of [Tc(CO)3]+ species
337
both within and out of a simulated waste environment, then applying this protocol to the
338
treatment of real waste supernatants. For example, the selectivity and sensitivity of this system
339
could be further enhanced by moving the conversion platform from solution into a chemically
ACS Paragon Plus Environment
19
Environmental Science & Technology
Page 20 of 24
340
selective polymer film environment. A polymer film works by charge selectivity, which would
341
isolate the target [Tc(CO)3]+ species from negatively-charged interferents, such as anionic
342
components within solution. It also may have the added benefit of preconcentrating the target
343
[Tc(CO)3]+ species within the film, further enhancing the sensitivity and limit of detection.39
344
ASSICOATED CONTENT
345
Supporting Information
346
The Supporting Information is available free of charge on the ASC Publications website.
347
Synthesis of Re(CO)5Br; excitation and emission of [Re(CO)3(bpy)(H2O)]+; and the full
348
concentration range for the emission profile of [Re(CO)3(bpy)(H2O)]+ in acetonitrile.
349
AUTHOR INFORMATION
350
Corresponding Authors
351
*E-mail:
[email protected] Phone: 509/375-5648;
352
*E-mail:
[email protected] Phone: 513/556-9210
353
Notes
354
The authors declare no competing financial interest.
355
ACKNOWLEDGMENTS
356
This research was supported by the U.S. Department of Energy’s Office of Environmental
357
Management and performed as part of the Technetium Management Hanford Site project at the
358
Pacific Northwest National Laboratory (PNNL) operated by Battelle for the U.S. Department of
ACS Paragon Plus Environment
20
Page 21 of 24
Environmental Science & Technology
359
Energy under Contract No. DE-AC05-76RL01830. The authors would like to especially
360
acknowledge Dr. N. P. Machara for the stewardship of this research. We would like to
361
acknowledge Zheming Wang and Jesus Romero for the use of instrumentation and of the
362
simulated Hanford waste supernatant.
363
REFERENCES
364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398
1. Research Needs for High-Level Waste Stored in Tanks and Bins at U.S. Department of Energy Sites: Environmental Management Science Program. The National Academies Press: Washington, DC, 2001. 2. Monk, D. J.; Stegemiller, M. L.; Conklin, S.; Paddock, J. R.; Heineman, W. R.; Seliskar, C. J.; Ridgway, T. H.; Bryan, S. A.; Hubler, T. L., Spectroelectrochemical Sensor for Technetium: Preconcentration and Quantification of Pertechnetate in Polymer-Modified Electrodes. In Subsurface Contamination Remediation, American Chemical Society: 2005; Vol. 904, pp 306-321. 3. Anderson, T.; Walker, R., Determination of picogram amounts of technetium-99 by resin bead mass spectrometric isotope dilution. Anal. Chem. 1980, 52, (4), 709-713. 4. Schroeder, N. C.; Ashley, K. R., Separation of non-pertechnetate species from Hanford AN-107 tank waste. J. Radioanal. Nucl. Chem. 2005, 263, (3), 567-573. 5. Stegemiller, M. L.; Heineman, W. R.; Seliskar, C. J.; Ridgway, T. H.; Bryan, S. A.; Hubler, T.; Sell, R. L., Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 11. Design and evaluation of a small portable sensor for the determination of ferrocyanide in hanford waste samples. Environmental Science & Technology 2003, 37, (1), 123-130. 6. Chatterjee, S.; Bryan, S. A.; Seliskar, C. J.; Heineman, W. R., Three-component spectroelectrochemical sensor module for the detection of pertechnetate (TcO4-). Rev. Anal. Chem. 2013, 32, (3), 209-224. 7. Nuclei Formed in Fission: Decay Characteristics, Fission Yields, and Chain Relationships. (issued by the Plutonium Project). J. Am. Chem. Soc. 1946, 68, (11), 2411-2442. 8. Nichols, A.; Aldama, D.; Verpelli, M., Handbook of nuclear data for safeguards: database extensions, August 2008. IAEA INDC (NDS)-0534 2008. 9. Serne, R. J.; Rapko, B. M. Technetium Inventory, Distribution, and Speciation in Hanford Tanks; PNNL-23319, EMSP-RPT-022, Rev. 1; Pacific Northwest National Laboratory: Richland, Washington, 2014. 10. Schwochau, K., Technetium: chemistry and radiopharmaceutical applications. John Wiley & Sons: 2008. 11. Strickert, R.; Friedman, A. M.; Fried, S., The Sorption of Technetium and Iodine Radioisotopes by Various Minerals. Nucl. Technol. 1980, 49, (2), 253-266. 12. El-Wear, S.; German, K. E.; Peretrukhin, V. F., Sorption of technetium on inorganic sorbents and natural minerals. J. Radioanal. Nucl. Chem. 1992, 157, (1), 3-14. 13. Duncan, J. B. The Removal of Technetium-99 from the Effluent Treatment Facility Basin 44 Waste Using Purolite A-530E®, Reillex HPQ®, and Sybron IONAC SR-7® Ion Exchange
ACS Paragon Plus Environment
21
Environmental Science & Technology
399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443
Page 22 of 24
Resins; RPP-RPT-23199, Revision 0; CH2M HILL Hanford Group. Ioc.: Richland, Washington, 2004. 14. Kasprzak, L.; Aubert, C.; Cossonnet, C.; Fattahi, M. A new measurement method for quantification and speciation of technetium-99 in sample at environmental concentrations; Second European IRPA congress on radiation protection - Radiation protection: from knowledge to action: 2006. 15. Terry, A. A.; Zittel, H. E., Determination of Technetium by Controlled-Potential Coulometric Titration in Buffered Sodium Tripolyphosphate Medium. Anal. Chem. 1963, 35, (6), 614-618. 16. Gu, B.; Ruan, C., Determination of Technetium and Its Speciation by Surface-Enhanced Raman Spectroscopy. Anal. Chem. 2007, 79, (6), 2341-2345. 17. Lukens, W. W.; Shuh, D. K.; Schroeder, N. C.; Ashley, K. R., Identification of the nonpertechnetate species in Hanford waste tanks, Tc (I)-carbonyl complexes. Environ. Sci. Technol. 2004, 38, (1), 229-233. 18. Chatterjee, S.; Norton, A. E.; Edwards, M. K.; Peterson, J. M.; Taylor, S. D.; Bryan, S. A.; Andersen, A.; Govind, N.; Albrecht-Schmitt, T. E.; Connick, W. B.; Levitskaia, T. G., Highly Selective Colorimetric and Luminescence Response of a Square-Planar Platinum(II) Terpyridyl Complex to Aqueous TcO4–. Inorg. Chem. 2015, 54, (20), 9914-9923. 19. Chatterjee, S.; Del Negro, A. S.; Smith, F. N.; Wang, Z.; Hightower, S. E.; Sullivan, B. P.; Heineman, W. R.; Seliskar, C. J.; Bryan, S. A., Photophysics and luminescence spectroelectrochemistry of [Tc(dmpe)3]+/2+ (dmpe = 1,2-bis(dimethylphosphino)ethane). J. Phys. Chem. A 2013, 117, (48), 12749-12758. 20. Chatterjee, S.; Del Negro, A. S.; Edwards, M. K.; Bryan, S. A.; Kaval, N.; Pantelic, N.; Morris, L. K.; Heineman, W. R.; Seliskar, C. J., Luminescence-based spectroelectrochemical sensor for [Tc(dmpe)3]2+/+ (dmpe = 1,2-bis(dimethylphosphino)ethane) within a charge-selective polymer film. Anal. Chem. 2011, 83, (5), 1766-1772. 21. Alberto, R., New Organometallic Technetium Complexes for Radiopharmaceutical Imaging. In Contrast Agents III: Radiopharmaceuticals – From Diagnostics to Therapeutics, Krause, W., Ed. Springer Berlin Heidelberg: Berlin, Heidelberg, 2005; pp 1-44. 22. Alberto, R.; Ortner, K.; Wheatley, N.; Schibli, R.; Schubiger, A. P., Synthesis and Properties of Boranocarbonate: A Convenient in Situ CO Source for the Aqueous Preparation of [99mTc(OH2)3(CO)3]+. J. Am. Chem. Soc. 2001, 123, (13), 3135-3136. 23. Alberto, R.; Schibli, R.; Egli, A.; Schubiger, A. P.; Abram, U.; Kaden, T. A., A Novel Organometallic Aqua Complex of Technetium for the Labeling of Biomolecules: Synthesis of [99mTc(OH2)3(CO)3]+ from [99mTcO4]- in Aqueous Solution and Its Reaction with a Bifunctional Ligand. J. Am. Chem. Soc. 1998, 120, (31), 7987-7988. 24. Fernandez-Moreira, V.; Thorp-Greenwood, F. L.; Amoroso, A. J.; Cable, J.; Court, J. B.; Gray, V.; Hayes, A. J.; Jenkins, R. L.; Kariuki, B. M.; Lloyd, D.; Millet, C. O.; Williams, C. F.; Coogan, M. P., Uptake and localisation of rhenium fac-tricarbonyl polypyridyls in fluorescent cell imaging experiments. Org. Biomol. Chem. 2010, 8, (17), 3888-3901. 25. Chan, C. Y.; Pellegrini, P. A.; Greguric, I.; Barnard, P. J., Rhenium and Technetium Tricarbonyl Complexes of N-Heterocyclic Carbene Ligands. Inorg. Chem. 2014, 53, (20), 10862-10873. 26. Richter, M. M.; Debad, J. D.; Striplin, D. R.; Crosby, G.; Bard, A. J., Electrogenerated chemiluminescence. 59. Rhenium complexes. Anal. Chem. 1996, 68, (24), 4370-4376.
ACS Paragon Plus Environment
22
Page 23 of 24
444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483
Environmental Science & Technology
27. Del Negro, A. S.; Wang, Z.; Seliskar, C. J.; Heineman, W. R.; Sullivan, B. P.; Hightower, S. E.; Hubler, T. L.; Bryan, S. A., Luminescence from the trans-dioxotechnetium(V) chromophore. J. Am. Chem. Soc. 2005, 127, (43), 14978-14979. 28. Chatterjee, S.; Del Negro, A. S.; Wang, Z.; Edwards, M. K.; Skomurski, F. N.; Hightower, S. E.; Krause, J. A.; Twamley, B.; Sullivan, B. P.; Reber, C.; Heineman, W. R.; Seliskar, C. J.; Bryan, S. A., Electronic and molecular structures of trans-dioxotechnetium(V) polypyridyl complexes in the solid state. Inorg Chem 2011, 50, (12), 5815-5823. 29. Del Negro, A. S.; Seliskar, C. J.; Heineman, W. R.; Hightower, S. E.; Bryan, S. A.; Sullivan, B. P., Highly oxidizing excited states of Re and Tc complexes. J. Am. Chem. Soc. 2006, 128, (51), 16494-16495. 30. Bryan, S. A.; Branch, S. D.; Heineman, W. R.; Rapko, B. M.; Lines, A. M.; Soderquist, C. Z., Non-pertechnetate Technetium Sensor Research and Development. In Pacific Northwest National Laboratory: Richland, WA, 2017. 31. Chatterjee, S.; Del Negro, A. S.; Edwards, M. K.; Bryan, S. A.; Kaval, N.; Pantelic, N.; Morris, L. K.; Heineman, W. R.; Seliskar, C. J., Luminescence-Based Spectroelectrochemical Sensor for [Tc(dmpe)(3)](2+/+) (dmpe=1,2-bis(dimethylphosphino)ethane) within a ChargeSelective Polymer Film. Anal Chem 2011, 83, (5), 1766-1772. 32. Harris, D. C., Quantitative Chemical Analysis. 8 ed.; W. H. Freeman: 2010. 33. Schmidt, S. P.; Trogler, W. C.; Basolo, F.; Urbancic, M. A.; Shapley, J. R., Pentacarbonylrhenium Halides. In Inorganic Syntheses, John Wiley & Sons, Inc.: 2007; pp 160165. 34. Lazarova, N.; James, S.; Babich, J.; Zubieta, J., A convenient synthesis, chemical characterization and reactivity of [Re(CO)3(H2O)3]Br: the crystal and molecular structure of [Re(CO)3(CH3CN)2Br]. Inorg. Chem. Commun. 2004, 7, (9), 1023-1026. 35. Kurz, P.; Probst, B.; Spingler, B.; Alberto, R., Ligand variations in [ReX(diimine)(CO)(3)] complexes: Effects on photocatalytic CO2 reduction. Eur J Inorg Chem 2006, (15), 2966-2974. 36. Levitskaia, T. G.; Anderson, A.; Chatterjee, S.; Cho, H. M.; Rapko, B. M.; Peterson, J. M.; Walter, E. D.; Washton, N. M. Speciation and Oxidative Stability of Alkaline Soluble, NonPertechnetate Technetium; PNNL-23654, EMSP-RPT-024, Rev. 0; Pacific Northwest National Laboratory: Richland, Washington, 2014. 37. Pitchumony, T. S.; Banevicius, L.; Janzen, N.; Zubieta, J.; Valliant, J. F., Isostructural Nuclear and Luminescent Probes Derived From Stabilized [2+1] Rhenium(I)/Technetium(I) Organornetallic Complexes. Inorganic Chemistry 2013, 52, (23), 13521-13528. 38. Henry, M. S.; Hoffman, M. Z., Photophysics and photochemistry of aromatic nitrogen heterocycles. Fluorescence from 2,2'-bipyridine and 1,10-phenanthroline. J. Phys. Chem. 1979, 83, (5), 618-625. 39. Heineman, W. R.; Seliskar, C. J.; Richardson, J. N., Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device: An overview. Aust. J. Chem. 2003, 56, (2-3), 93-102.
484 485
ACS Paragon Plus Environment
23
Environmental Science & Technology
486
Page 24 of 24
TOC graphic
487 488
ACS Paragon Plus Environment
24