Industrial Instruments - Analytical Chemistry (ACS Publications)

Anal. Chem. , 1964, 36 (9), pp 94A–94A. DOI: 10.1021/ac60215a789. Publication Date: August 1964. Copyright © 1964 American Chemical Society...
0 downloads 0 Views 325KB Size
MEASURING

SPECIFIC CONDUCTANCE?

may we recommend...

m Model RC-16B2... a general purpose conductivity bridge featuring extremely wide range, high sensitivity, and moderate accuracy of ± 1 % . The Model RC-16B2 has a dual calibration, in resistance and conductance units. Bridge current at 50-60 and 1000 cycles are provided, selected by a panel mounted switch. A sensitivity control is provided to permit increase of sensitivity without reducing the speed with which the instrument may be balanced. When used with conductivity cells of appropriate cell constants, the entire range of electrolytic conductance from that of ultra-pure demineralized water to concentrated acids is easily covered. Price $237.00

....

* . - ; ' •

Model RC-18 Conductivity Bridge... a precision laboratory instrument measuring electrolytic:;conductivity and resistivity in micromhos and ohms to ± 0 . 1 % accuracy. Internal generator frequencies of 1000 and 3000 cps are provided, and balance indication is by means of a selfcontained, two-inch oscilloscope. Bridge balance is obtained through operation, of 6 decades of cardwound resistors of 0.1 to 10,000 ohms each. The overall instrument range is 0-100,000 ohms. Sensitivity is better than ± 0 . 0 1 % . A decade of 100 pf mica capacitors and two 10-100 pf adjustable air capacitors permit balancing the reactive component of the conductivity cell: impedance, Price $850.00

Recording Requirements?.. .The Model RA-4 Solu Meter® is a direct-reading instrument providing a continuous indication of solution conductivity. In addition, a 0-10 mv DC signal proportional to conductivity is provided to operate a remote potentiometer recorder. A nonbridge type of measuring circuit is utilized, and meter scales are linear in conductivity. Accuracy is within 2% of scale span with supply voltages between 105 and 125. Adjustment of full scale meter deflection against a built-in standard resistor permits closer readings. Solu Meters can be supplied in a great many different ranges and calibrations. The Model RA-4 is provided with a temperature compensator to correct for the change of conductivity with temperature. A manual compensator is standard in the Solu Meters; automatic compensators are available as optional equipment for every service. Price $186.00

"W

Electrolytic Conductivity Cells. A most comprehensive line of cells and cell constants is available for every application from measurement of ultra-pure water to concentrated solutions of acids, alkalis and salts. Dip type glass and platinum conductivity cells are available in any cell constant from 1/10O to 100 with certified accuracy within ± 1 % of nominal value. Pipette cells, for making conductivity measurements with small volumes of solution, are furnished for samples as small as 1/100 ml. Cell constants range from 5 to 500/cm. Jones type cells in many cell constants can also be provided. Prices on request.

Industrial Instruments Inc. has pioneered in the field of electrolytic conductivity and offers a complete line of instrumentation and cells. In addition, we can supply a variety of gas analysis equipment for laboratory and plant use. We invite your inquiries on the application of our equipment to your particular requirements. AH prices FOB Factory

ELECTROLYTIC CONDUCTIVITY IS OUR BUSINESS!

Industrial Instruments 89 C o m m e r c e Road, Cedar Grove, Essex C o u n t y , N. J2 0 1 C E n t e r 9-6200 TWX: 2 0 1 239-4704

Circle No. 49 on Readers' Service Card

94 A

·

ANALYTICAL CHEMISTRY

;