Influence of Surface Potential on the Adhesive Force of Radioactive

Aug 23, 2013 - Georgia Institute of Technology, Atlanta, Georgia 30332-0373, United States. ‡. University of Tennessee, Knoxville, Tennessee 37996, ...
0 downloads 0 Views 2MB Size
Article pubs.acs.org/Langmuir

Influence of Surface Potential on the Adhesive Force of Radioactive Gold Surfaces Hyojin Kweon,† Sotira Yiacoumi,† Ida Lee,‡ Joanna McFarlane,§ and Costas Tsouris*,†,§ †

Georgia Institute of Technology, Atlanta, Georgia 30332-0373, United States University of Tennessee, Knoxville, Tennessee 37996, United States § Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6181, United States ‡

S Supporting Information *

ABSTRACT: Radioactive particles may acquire surface potential through self-charging, and thus can behave differently from natural aerosols in atmospheric systems with respect to aggregation, deposition, resuspension, and transport to areas surrounding a radioactive source. This work focuses on the adhesive force between radioactive particles and metallic surfaces, which relates to the deposition and resuspension of particles on surrounding surfaces. Scanning surface potential microscopy was employed to measure the surface potential of radioactive gold foil. Atomic force microscopy was used to investigate the adhesive force for gold that acquired surface charge either by irradiation or by application of an equivalent electrical bias. Overall, the adhesive force increases with increasing surface potential or relative humidity. However, a behavior that does not follow the general trend was observed for the irradiated gold at a high decay rate. A comparison between experimental measurements and calculated values revealed that the surface potential promotes adhesion. The contribution of the electrostatic force at high levels of relative humidity was lower than the one found using theoretical calculations due to the effects caused by enhanced adsorption rate of water molecules under a high surface charge density. The results of this study can be used to provide a better understanding of the behavior of radioactive particles in atmospheric systems.



INTRODUCTION The influence of radioactivity on human health has raised concerns about radioactivity transport in the environment. These concerns have increased since the nuclear accidents at Chernobyl, Ukraine (April 26, 1986) and more recently at Fukushima Daiichi, Japan (March 11, 2011). Problems related to radioactivity after such incidents may continue for several decades because of the generation of long-lived isotopes and the transport of radioactive particles in the environment. Radioactive fallout contaminates not only air but also water and soil, making contamination effects more harmful. Like other particulate matter, radioactive particles deposited onto soil and plants can be resuspended by natural and anthropogenic activities, such as wild fires and human-initiated burning,1,2 propagating radioactive contamination to uncontaminated areas long after a nuclear event. Because of health issues and longterm effects associated with aerosols contaminated by adsorbed isotopes,3 it is essential to monitor and control the transport of radioactivity. Transport of radioactive particles plays an important role in spreading radioactivity.4 Traditional models of particle transport, however, fail to predict the behavior of radioactive particles in atmospheric systems because of changes in their surface electrostatic potential due to radioactivity-induced charging.1,2,5−7 The charging process can be one of the most important features of radioactive particles, which acquire © 2013 American Chemical Society

surface charge through two main processes: (1) ionization due to the emission of either charged particles or electrons during radioactive decay, and (2) adsorption of ions generated in the surrounding medium.4,8−11 More specifically, the net surface charge depends on particle radioactivity and the ion concentration of the surrounding medium.9,11 Another factor that affects the surface charge of radioactive particles is their size.10,12 The transport of colloidal radioactive particles can be significantly different from that of larger particles. Surface charge acquired by the particles during the decay processes can affect their travel distance. Furthermore, the surface charge may attract particles to interacting surfaces, inducing an increase in the deposition rate of radioactive particles. The enhancement in the deposition of particles may be due to the increase of interaction force by the additional electrical Coulomb or image forces.11 Therefore, in order to develop a predictive model that accurately describes the behavior of radioactive aerosols, a study focused on surface forces of colloidal radioactive particles is required. The relative humidity (RH) plays an important role in the transport of particles in atmospheric systems. In general, a higher RH promotes particle adhesion due to the capillary force Received: March 11, 2013 Revised: August 23, 2013 Published: August 23, 2013 11876

dx.doi.org/10.1021/la4008476 | Langmuir 2013, 29, 11876−11883

Langmuir

Article

Figure 1. (a) Side view and (b) top view of an AFM tip. (c) Schematic of the adhesion of a spherical particle on a planar surface. glovebox. The foil was transported to an analytical laboratory at ORNL and attached to an AFM magnetic puck with double-sided tape, which securely held the sample on the AFM stage during the force measurements. The AFM head was located in a contamination zone, with shielding provided by a 6-mm-thick Lucite box positioned on a floating table. (ii). Application of Electrical Bias. A small rectangular piece (approximately 2 mm × 3 mm) of nonradioactive pure gold foil was attached onto a magnetic stainless steel disc with silver paint, which allowed the application of electrical bias to the foil. Prior to each measurement, the prepared sample was cleaned with ethanol and acetone and then thoroughly rinsed with deionized water. The clean sample was stored in a silica gel dehydrator about 24 h prior to the experiments. 2. Surface Potential Measurements. The surface potential of irradiated gold and its corresponding surface topography were obtained by combined AFM (Nanoscope IIIa, Veeco Instruments, Plainview, NY) and scanning surface potential microscopy (SSPM), also known as Kelvin probe force microscopy (KPFM), located at ORNL. Scanning probe microscopy was used with the objective to capture the physical properties of the surfaces, including surface topography and surface potential. First, the surface topography was measured by recording a line trace with the AFM instrument operating in tapping mode. By using the built-in lift-mode feature, the lift-mode scan tracked the previously stored surface topographic scan. The surface topography trace was stored and followed by a second, spatially elevated trace for the measurement of the electrical potential at a height of 50 nm above the sample surface. The lift-mode takes out the surface features in the SSPM image. The surface topography and corresponding SSPM map were recorded on a raster-by-raster basis with alternating sequential scans at a scan rate of 1 Hz; 265 lines were used to form two-dimensional images. The SSPM apparatus was calibrated with specially prepared surface structures in which gold was sputtered on ultraflat cover-glass slides. Various DC step voltages of 10 mV interval provided a constant voltage source correlated with the electrical-potential image map of the structures obtained with SSPM. An SSPM image with steps can be viewed and measured. The detailed calibration procedure has been published previously.20 The conducting tips were PPP-EFM purchased from Nanosensors. The tip geometry was determined by using calibration standards made by NT-MDT, and the approximate radius of the tip apex was found to be 100 nm. The tip was checked by applying external potentials for conductivity prior to the experiments. This procedure allowed the measurement of the surface potential value within a maximum error of 5%.21,22 Based on the theory of SSPM, when the tip charge is equal to the surface charge, the second derivative of the capacitance between

by forming a water meniscus between a particle and another interacting surface. At the same time, however, it can decrease the electrostatic force by dissipating the surface charge. In addition, a high surface charge density may lead to enhanced adsorption of water molecules from the surrounding atmosphere.13 Charge buildup due to the humidity has also been reported.14 Therefore, a possible competition of the influences of RH and radioactivity on the behavior of radioactive particles needs to be considered. The interaction forces of colloidal particles can be studied using atomic force microscopy (AFM).15,16 AFM has been used in our previous work to study the interaction forces between bacterial spores and various planar surfaces.17,18 The interaction forces of an individual particle and different surfaces were quantified under various conditions by obtaining the force− distance profile between the particle and the planar surface. The data were then analyzed by considering various mechanisms acting on the particles and surfaces, including van der Waals attraction, electrostatic interaction, and capillary forces. The present study aims at providing a fundamental understanding of the influence of radioactivity and RH on the interaction of colloidal radioactive particles by means of adhesive force measurements using AFM and theoretical calculations. The competition of radioactivity and RH effects is also investigated.



EXPERIMENTAL AND MODELING METHODS

1. Surface Preparation. (i). Activation of Gold by Neutron Irradiation. Gold foil was chosen as representative of metallic surfaces, which are of interest in particle resuspension mechanics. A pure gold foil was activated by neutron capture and used to measure surface potential and surface forces. A detailed procedure for the activation of gold can be found in previous work.19 In brief, small square pieces of gold foil were cleaned with ethanol to remove any traces of organic contamination. A single piece encased in a polyethylene vial was transported by pneumatic transfer tube PT-2 into the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). Coirradiated monitors were used to determine the neutron fluence. Both the gold sample and the monitor were carefully placed in the HFIR “rabbit” and irradiated for a few seconds. The resulting radioactivity of each gold sample was 150−500 μCi (microcuries), depending on the duration of irradiation. The dominant produced isotope was 198Au, which decays through beta and gamma emissions, with a half-life of 2.7 days. The sample was allowed to decay outside the reactor to a level of radioactivity permitting safe handling outside a 11877

dx.doi.org/10.1021/la4008476 | Langmuir 2013, 29, 11876−11883

Langmuir

Article

Figure 2. (a) Surface topography and (b) surface potential at 30.2 μCi and 55% RH; (c) surface topography and (d) surface potential at 108 μCi and 55% RH. Due to the random, nonuniformly distributed in time, emission charging and charging by diffusion of ionized molecules, the potential values in (b) vary with time. The values of the surface potential in (d) are greater than 10 V, which is the saturation limit of the SSPM instrument. the two is equal to zero.22 Ambient or humid conditions should not influence the capacitance unless it is in a highly conducting medium. 3. Adhesive Force Measurements. The adhesive force of the gold surface, prepared as discussed in subsection 2 under Experimental and Modeling Methods, was measured by AFM using a cantilever with a silicon nitride (Si3N4) tip. For the irradiated gold, the AFM Caliber (Veeco Instruments, Plainview, New York) instrument was used, whereas for the nonradioactive gold the AFM MultiMode V (Veeco Instruments, Plainview, New York) instrument, which allows the application of electrical bias and direct measurement of the cantilever spring constant, was used. The deflection signal, recorded in volts during the probe motion, was converted to force (nanonewtons) through Hooke’s law: F = kSΔV, where F, k, S, and ΔV are the force, spring constant, photodiode sensitivity, and change in deflection signal, respectively. The spring constant of the cantilevers was measured by the thermal tune method, which was performed using the Multimode V AFM instrument.23 The adhesive force was measured over a period of weeks following the radioactivity window. During the measurements, RH was controlled between