Infrared Quantative Analysis Data. CS-115 Determination of

Determination of Benzene and the C7- to C10- Methylbenzenes. D. E. NICHOLSON and S. H. HASTINGS,Humble Oil & Refining Co., Baytown, Tex. CS-114...
1 downloads 0 Views 89KB Size
Determination of Benzene and the

C7- to CloMethylbenzenes CS-114

D. E. NICHOLSON a n d S. H. HASTINGS, Humble O i l 8 Refining Co., Bayfown, l e x .

Component Name

-

No.

Range

Accuracy

X or v

%

6.1. Pfs.

Formula

1

Slit ( m m )

1 ~

16.20~

hl.0

0-100

AX or Av __ 0.218

Cancn. g/liter length, mm

1 0.100

Methylbenzene

0-100

h0.5

1,4-Dimethylbenzene

0-100

h0.5

1,3-Dimethylbenzene

0- 100

10.5

1,B,J-Trimethyl benzene

0- 100

hl.0

19.36~

1,2,4-TrimethyIbenzene

0-100

zk0.5

18.49~

h1.5

18.54~

0-100

1

j

CiaHir

1,2,3,4-Tetramethylbenzene

CiaHir

I

1 0.100

1

0.324 ~

I

3~0.5

1,2,3,5-TetramethyIbenzene

'

11

22.93p

0.528

0.100

1,2,4,.5-Tetramethylbenzene

1

0.533

h0.5

1,2,3-TrimethyIbenzene

10

23.13~

0-100

1,2-Dimethylbenzene

0-100

1.0.5

18.17~

0-100

h0.5

18.06~

1

1 0.100

0.290

1

0*292 0.495

0.100 1 0.100 1 0.100 1 0.100

0.273

1 0.100

Instrument: Perkin-Elmer Model 1 12, CsBr prism Sample Phase: Solution in carbon tetrachloride Cell Windows: CsBr Absorbance Measurement: Calculation:

Base line-

Inverse matrixGraphical-

P o i n t X Successive a p p r o x . 2 -

Relative Absorbances-Analytical Matrix:

16.20~ 0.200 0.069 0.033 0.029 0.041 0.027 0.033 0.032 0.000 0.027 0.043

ComponentlX

1 2 3 4

5 6 7 8 9 10 11

21.50~ 0.01 6.89 0.22 0.05 0.05 0.03 0.07 0.04 0.06 0.03 0.15

20.60~ 0.01 0.13 12.10 0.03 0.05 0.02 0.04 0.10 0.00 0.03 0.14

23.13~ 0.06 0.06 0.05 3.61 1.49 0.02 0.61 0.03 0.12 0.02 0.03

22.93M 0.02 0.07 0.06 1.67 3.70 0.02 1.51 0.03 0.25 0.02 0.03

19.361 0.015 0.072 0.089 0.197 0.070 0.284 0.052

0.073 0.010 0.070 0.052

18.49~ 0.02 0.05 0.05 0.05 0.04 0.03 2.23 0.36 0.00 0.14 0.13

18.54~ 0.023 0.050 0.054 0.042 0.034 0.034 1.600 0.388 0.000 0.131 0.119

22.43~ 0.02 0.12 0.08 0.13 0.18 0.02 0.42 1.94 2.94 0.02 0.03

18.06~ 0.023 0.031 0.052 0.033 0.040 0.030 0.157 0.044 0.000 0.434 1.587

18.17~ 0.022 0.033 0.053 0.036 0.041 0.032 0.167 0.054 0.000 1.650 1.015

99.9%

Material Purity:

Comments: To obtain maximum accuracy in the final analytical result, it i s necessary to combine the infrared data on actual samples with molecular weight distribution b y mass spectrometry.

Determination of Methylindanes

S. H.

HASTINGS a n d D. E. NICHOLSON, Humble Oil 8 Reflning Co., Baytown, l e x .

CS-115

I

Insfrument. Perkin-Elmer Model 1 12, CsBr prism Sample Phase: Solution in carbon tetrachloride

I

Component mm

indane -I

2

11

2-Methylindane

-

indane

indane

138

1

Calculafion:

'

~ _ _ _ _ _ _ 0-100 f2 claH1'

1

I

~

iyG~1 2 -!

~

Cell Windows: CsBr Absorbance Measurement.

~

1 *'

ANALYTICAL CHEMISTRY

j I

__ 0.578

~ _I _ 2 0 . 2 6 ~ 0.360 ~

-1-

2 3 . 7 6 ~ 0.565 ~

0.100

1

___ 1

i

0.100 _

0.100 1

~

1

~

' o'loo 1

Base line-

Inverse matrixGraphical-_--

PointXSuccessive o p p r o x . 2 -

Relative Absarbance~AnalyticaIMatrix: Campanent/X _ _

21 3 4 Material Purity:

22.43~ 1.090 0.065 0.055 0.101 95%

24.03~ 0.508 1.562 0.035 0.840

20.26~ 0.061 0.402 0.279 0.093

23.76~ 0.407 0.946 0.033

1.779