KEITHLEY INSTRUMENTS - ACS Publications - American Chemical

May 25, 2012 - KEITHLEY INSTRUMENTS. Anal. Chem. , 1963, 35 (7), pp 132A–132A. DOI: 10.1021/ac60200a841. Publication Date: June 1963. Copyright ...
1 downloads 0 Views 351KB Size
NEW

PRODUCTS

THERMOLYNE

measures .002 microvolts!

KEITHLEY MILLIMICROVOLTMETER T h e Keithley Model 149 is t h e m o s t sensitive electronic v o l t m e t e r avail­ able today, having a signal-to-noise ratio t h a t a p p r o a c h e s t h e t h e o r e t i c a l limit. R e c o m m e n d e d f o r u s e with t h e r m o c o u p l e s or t h e r m o p i l e s , t h e Model 149 is also ideal in cryogenics investigations and Hall Effect studies. Zero s u p p r e s s i o n u p t o 100 t i m e s full scale adds versatility for t h e user. L i n e - o p e r a t e d , t h e M o d e l 149 can a c c o m m o d a t e either a float­ i n g or g r o u n d - r e f e r e n c e d i n p u t . O u t p u t is 5 ν or 5 m a on all ranges. Brief s p e c i f i c a t i o n s :

The Model 2 2 - 0 2 Triple ADC, multi­ parameter analysis system, will con­ vert experimental data t o computer language. The three channels pro­ vide 3 pulse amplifiers, 3 analog t o digital converters giving up t o one part in a 1 0 0 0 (or 1024) resolution, t r i p l e 0.5-μ, second coincidence shap­ ing circuits, 3 6 b i t register for " o n e event" buffer storage and binarycoded-decimal data format. Radia­ tion Instrument Development Labora­ tory, 4 5 0 1 West North Ave., Melrose Park, III. 409

Pyrolyzate

• - i finest lipwrtj hot plate value

NOW greatly refined and

Spectra

The infrared spectra of 500 com­ mercial materials have been prepared by examination of pyrolysis products. Included are selected polymers, rub­ bers, elastomers, and related ma­ terials. Each spectrum is labeled with commercial name, manufacturer, in­ strument used, Sadtler serial number, and other technical information. Sadtler Research Laboratories, Inc., 1517 Vine St., Philadelphia 2, Pa. 4 1 0

THERMOLYNE TYPE A 1 9 0 0 N o w e v e n f i n e r hot plate per­ f o r m a n c e . . . Fast h e a t i n g . . .

• range: 0.1 microvolt to 100 millivolts in 13 overlapping l x and 3x steps • noise: less than 6 χ 10-'° ν rms with shorted input J input impedance: 10K ohms on 0.1 μν range rising to 10 megohms on 100 μν scale stability: within 0.01 μν per hour speed of response: to 90% fs in .5 seconds on most ranges • accuracy: 2% fs on all ranges • price: $895.00

W i d e temperature range.

Close

Other MICROVOLTMETERS: Model 150A 1 μν sensitivity $750.00 Model 151 100 μν sensitivity $420.00

w o r k . . . . Stainless steel case is

stepless t h e r m o s t a t i c c o n t r o l f r o m 1 0 " F above room temperature to 7 0 0 D F . . . I m p r o v e d i n s u l a t i o n , baffles, and control unit . . . . A t t r a c t i v e , e a s y - t o - r e a d a n d set control dial. Use this 6 " s q u a r e h o t p l a t e f o r a v a r i e t y o f r o u t i n e a n d critical c o r r o s i o n resistant a n d s c i e n t i f i c a l l y v e n t i l a t e d f o r c o o l , safe o p e r a t i o n on table t o p or f i x t u r e .

full details in latest catalog ... 115 ν A C

KEITHLEY INSTRUMENTS 12415 Euclid Avenue · Cleveland 6, Ohio Circle No. 199 on Readers' Service Card 132 A

·

ANALYTICAL CHEMISTRY

The atmosphere controller shown adapts to most conventional instru­ ments to provide a gaseous at­ mosphere for the spectrographic analysis of metals. Angstrom, Inc., 2 4 5 4 West 3 8 t h St., Chicago 3 2 , III.

411

700 w

$22.75

Write f o r literature and name o f nearest

leader.

THERMOLYNE CORPORATION Dept. 478, 2555 Kerper Blvd., Dubuque, Iowa Circle No. 118 on Readers' Service Card