(LDH). The activity of this.enzyme is frequently measured in serum of patients suspected of having had a heart attack. The decreasing absorbance "A" a...
3 downloads 0 Views 614KB Size
LDH A

LDH B

LDH

LDH C D

LDH/ Ι /LDH Ε/

Γ- / F

The chart above demonstrates the kinetic spectrophotomefric assay of lactic dehydrogenase (LDH). The activity of this.enzyme is frequently measured in serum of patients suspected of having had a heart attack. The decreasing absorbance " A " at 340 ηψ is recorded against time as LDH catalyzes the reaction. _|_ |_p|^ pyruvate + DPKH

£

ΟΡΗ + H+ + lactate

The rate of this reaction (slope of d A / d t during the initial " O " order portion) is a measure of the enzyme's activity. Extreme slopes and/or deviation from linearity are indicative of an LDH abnormality. 30 production runs in ό groups are recorded on one chart, at 3 minutes/ group-

NEW AUTOMATIC TECHNIQUE REDUCES ENZYME ANALYSIS COSTS You can d o all of your reaction kinetics experiments on this o n e instrument, a n d still have a double-beam, scanning UVVisible S p e c t r o p h o t o m e t e r f o r b i l i r u b i n , barbiturate and salicylate analyses. The Automatic Multiple Sampling System using Perkin-Elmer's M o d e l 202 Spectro­ p h o t o m e t e r , saves y o u vital l a b o r a t o r y

a n a l y s i s time in c l i n i c a l serum studies. Kinetic reactions may be studied spectrophotometrically, o n a production scale of hundreds of analyses per day, at a mini­ mum cost per analysis. The analysis proceeds at a fixed w a v e ­ length of light. The wavelength you select is held constant while the decrease in ab­ sorbance of one of the reactants is re­ c o r d e d as a function of time. Perkin-Elmer's Automatic Multiple Sampling System features... • A double beam, direct absorbance re­ cording spectrophotometer with analytical accuracy of ± .01 absorbance units; • A unique d o t readout system that pro­

vides, on one chart, a complete continuous record of absorbance as a function of time for a batch of 5 samples plus a separate reference blank; • A t h e r m o s t a t e d sample c o m p a r t m e n t , with temperature control within ± 0.5 C from 2 0 ° to 5 0 ° C plus automatic sample positioning,· • A n a d j u s t a b l e time interval b e t w e e n sample readings of 3 to 120 seconds. For more information about this new en­ zyme analysis technique plus details on the Perkin-Elmer M o d e l 202 S p e c t r o ­ photometer write t o : Instrument Division, P e r k i n - E l m e r C o r p o r a t i o n , 705 M a i n Avenue, N o r w a l k , Connecticut.