Subscriber access provided by UNIVERSITY OF THE SUNSHINE COAST
Article
Mercury re-emission in the smelting flue gas cleaning process: the influence of arsenite Zhilou Liu, Dongli Wang, Bing Peng, Liyuan Chai, Shu Yang, Cao Liu, Cong Zhang, Xiaofeng Xie, and Hui Liu Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.7b01733 • Publication Date (Web): 12 Sep 2017 Downloaded from http://pubs.acs.org on September 13, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 23
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
schematic diagram of reaction mechanism 222x120mm (150 x 150 DPI)
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
Mercury re-emission in the smelting flue gas cleaning
2
process: the influence of arsenite
3 4 5 6
Zhilou Liu, a Dongli Wang,b Bing Peng,b, c Liyuan Chai,b, c Shu Yang,b
7
Cao Liu,b Cong Zhang,b Xiaofeng Xie,b Hui Liu,b, c*
8
a
9
Technology, Ganzhou 341000, China
School of Metallurgy and Chemical Engineering, JiangXi University of Science and
10
b
11
China
12
c
13
Metal Pollution, Changsha 410083, China
School of Metallurgy and Environment, Central South University, Changsha 410083,
Chinese National Engineering Research Center for Control & Treatment of Heavy
14 15 16 17 18 19 20
* Corresponding author. Postal address: School of Metallurgy and Environment,
21
Central South University, 932 South Lushan Road, Changsha 410083, China. E-mail:
22
[email protected] 1
ACS Paragon Plus Environment
Page 2 of 23
Page 3 of 23
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
23
ABSTRACT:
24
Recently, the Hg0 re-emission from flue scrubbing solutions has become a research
25
focus. The objective of this study was to evaluate the influence of arsenite on Hg0
26
re-emission by investigating critical important parameters, including the arsenite ion
27
concentration, pH values, solution temperature, fluorine ion concentration, and
28
chlorine ion concentration. The experimental results indicate that arsenite could
29
directly reduce Hg2+ to Hg0 and promote the decomposition of Hg(SO3)22-. High pH,
30
temperature and chlorine ion concentration contributed to the inhibition of Hg0
31
re-emission, but the fluorine ions had little effect. The mechanism research suggests
32
that the formation of unstable HgH2AsO3+ at low arsenite concentration accelerates
33
Hg0 re-emission. For the Hg(II)-As(III)-S(VI) system, the formation of unstable
34
HgSO3H2AsO3- than Hg(SO3)22- could increase Hg0 re-emission. With an increase in
35
arsenite concentration, the formation of Hg(H2AsO3)2 (which comes from the reaction
36
between HgSO3H2AsO3- and H2AsO3-) contributes to the suppression of Hg0
37
re-emission. The results of this study are conducive to providing new insight into Hg0
38
re-emission and mercury control.
39
Keywords: Hg0 re-emission; cleaning process; arsenite ions; smelting flue gas
40 41 42 43 44 2
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
45
1. Introduction
46
Mercury (Hg), due to its characteristics of long-distance transmission, volatility,
47
toxicity and bioaccumulation, has drawn wide attention 1, 2. The atmospheric mercury
48
emissions from nonferrous metal industries, especially zinc, lead and copper smelting,
49
are regarded as one of the largest anthropogenic sources of mercury in China 3, 4.
50
Since Hg is an important trace element associated with heavy metal sulfide ores, the
51
concentration of Hg in heavy metal concentrates is relatively high. In roasting and
52
smelting processes, nearly all the mercury in the concentrates are transferred to the
53
flue gas, leading to the formation of flue gas with high Hg concentration. Therefore,
54
understanding how to effectively control mercury emissions from nonferrous metal
55
industries has become an urgent question.
56
Different air pollution control devices, such as electrostatic precipitators (EP), wet
57
flue gas cleanings (WFGC) device and electrostatic demisters (ED), are installed to
58
purify nonferrous metal smelting flue gas 5, 6. The WFGC process has been widely
59
applied in nonferrous metal smelters due to its high purification efficiency in
60
simultaneously removing multiple pollutants and its low operating cost 7-9. In the
61
WFGC process, most of the particulate matter and some other harmful elements such
62
as fluoride, chloride, oxidized mercury (Hg2+), etc. are removed. Many studies have
63
reported that the WFGC process is the most efficient process for Hg removal,
64
accounting for 60% to 70% of the total Hg in the flue gas 10-12. However, soluble Hg2+
65
in the solution can be deoxidized to elemental mercury (Hg0) by reducible matter,
66
which may be followed by the volatilization of Hg0 in the flue gas during the WFGC 3
ACS Paragon Plus Environment
Page 4 of 23
Page 5 of 23
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
67
process 13-15. After the WFGC process, a sulfuric acid production process is performed
68
to recover SO2 16. In such a case, the Hg0 in the flue gas will deteriorate the quality of
69
the sulfuric acid product. Therefore, it is very important to understand the reduction
70
behavior of Hg2+ to reduce Hg to sulfuric acid and protect the environment.
71
Recently, many studies have reported that Hg2+ could be reduced by SO32- to Hg0
72
during the scrubbing process, lowering the total Hg capture efficiency 17-19. The
73
studies indicated that the formation of unstable HgSO3 was the mechanism of Hg
74
re-emission. Moreover, Van Loon 23 reported that some potential intermediates of the
75
decomposition reaction of HgSO3 were formed by the transfer of a single electron,
76
such as mercurous species (Hg+) and the sulfite radical anion (SO3-). The
77
disproportionation of Hg+ is an additional pathway of Hg re-emission. Some water
78
soluble ions (e.g., chloride ions, sulfate ions, sulfide ions, selenite ions, and metal ions,
79
etc.) could affect Hg2+ reduction or Hg0 emission behaviors that are reported by some
80
researchers 20-23. Different ions in solution have various influences on Hg
81
re-emission24-26.
82
complicated effect on the reduction process: it would benefit Hg re-emission due to
83
the formation of HgSO3NO2- at low concentrations which was more unstable than
84
HgSO3; it would also play an inhibiting effect on Hg reduction because of the
85
formation of Hg(NO2) 42- at high concentrations 22.
For example, the presence of nitrite ions was proven to have a
86
Except for traditional gas pollutants such as NOx, HCl and SO3, large amounts of
87
arsenic oxide (As2O3) particles can also be captured in the WFGC process 27. During
88
the scrubbing process, As2O3 particles, a typical pollutant for nonferrous metal 4
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
89
smelting flue gas, can be dissolved into scrubbing solutions in the form of H3AsO3,
90
H2AsO3-, HAsO32- or AsO33- 28, 29. In some smelters, the concentration of arsenite ions
91
in the scrubbing solution can reach up to 3.3 mg/L 30. However, there is little research
92
that focuses on the effect of arsenite on Hg re-emission. Arsenite ions may play a
93
complex role in Hg reduction behavior. On one hand, arsenite ions have an
94
intermediate valence state and may deoxidize Hg2+ and accelerate the Hg re-emission.
95
On the other hand, arsenite ion may coordinate with Hg2+ to stabilize Hg2+ and reduce
96
the Hg0 re-emission. As such, the influence of arsenite ion on Hg0 re-emission is a
97
worth studying to elucidate the rule of Hg2+ reduction.
98 99
As a further contribution to the understanding and interpretation of Hg reduction and re-emission behavior, this work studies the influence of arsenite on Hg0
100
re-emission in a simulated WFGC system. Variables including the concentration of
101
arsenite, sulfite, fluorine and chlorine ions, solution temperature, and solution pH
102
were evaluated. In addition, the intermediates of Hg2+ reduction were characterized,
103
and a mechanism for Hg0 re-emission under different conditions is proposed.
104
2. Experimental section
105
2.1 Experimental system and method
106
A typical lab-scale device shown in Figure 1 was set up in this study to investigate
107
Hg reduction and re-emission behaviors under different conditions. A high purity
108
nitrogen gas was used as a carrier gas at a flow rate of 0.6 L/min, and was blown into
109
liquid and then used to take the re-emission Hg0 which was released from liquid phase.
5
ACS Paragon Plus Environment
Page 6 of 23
Page 7 of 23
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
110
The bubbling reaction equipment included a 500 mL, round bottom, 3-neck flask that
111
contained a carry gas inlet, gas outlet, and placement of electrode to measure the
112
solution pH. The flask was placed in a constant temperature water bath to control the
113
solution
114
temperature-controlled heating belt at 120 °C to avoid the condensation of moisture
115
and the adsorption of Hg0 on the tube surface. Before mercury levels were tested, a
116
solution containing 30% (w/v) NaOH was used to prevent the corrosion by acid gas.
117
After measuring the Hg0 concentration in the flue gas, the tail gas treated with a
118
solution containing 5% (w/v) KMnO4 and activated carbon (AC) to absorb Hg0.
temperature.
Teflon
tubing
was
used
and
heated
with
a
119
At the beginning of every experiment, the simulated solution, which contained a
120
certain arsenite concentration, was put into a flask. Then the solution was heated to a
121
setting temperature and adjusted for pH. Afterwards the solutions with a
122
pre-determined concentration of Hg2+ or SO32- were quickly injected. The total
123
reaction solution volume was 300 mL. During the experiment, airtightness was
124
ensured to avoid Hg0 emission.
125 126
Figure 1. Schematic diagram of simulate Hg0 re-emission experimental device
127 6
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
128
2.2 Measurement Method
129
The Hg0 from Hg2+ reduction in outlet gas was continuously monitored using a
130
Lumex Zeeman Mercury Spectrometer (RA-915M, detection limit = 2 ng/m3), which
131
employed the resonance absorption of mercury atoms at the wavelength of 253.7 nm.
132
The Mercury Spectrometer had to be calibrated by pure nitrogen before taking
133
measurements. The solution containing Hg2+ was diluted to a suitable concentration
134
that was determined using atomic fluorescence spectrometry. The sulfite, fluorine and
135
chlorine concentrations in solution were determined using an ion chromatograph (883
136
basic IC plus, Metrohm Ltd.). A S220-Basic Seven Compact Mettler Toledo apparatus
137
was used for pH measurements of the solution.
138
To identify the mechanism of Hg2+ reduction in the mixed solution, the UV-visible
139
spectrum (UV-vis DRS: UV2450, China) was employed in this research. The solution
140
containing Hg2+ was prepared by dissolving HgO in concentrated perchloric acid
141
(HClO4) or nitric acid (HNO3), and then diluted to the required concentration. The
142
arsenic and sulfite solutions were obtained by dissolving pure sodium arsenite and
143
sodium sulfite in the dilute HClO4 respectively. Before every measurement, the
144
baseline spectrum of a solution with ultrapure water was collected and would be
145
subtracted from the spectrum of sample solutions to ensure the accuracy and
146
correctness of the detector response. After obtaining a uniform mixture, the prepared
147
solutions were placed in quartz cuvettes with the volume of 4 mL. The pH of the
148
scanning solution was adjusted by the addition of NaOH and HClO4 solutions. The
149
range of scanning wavelengths was from 200 to 300 nm, with a scanning speed of 100 7
ACS Paragon Plus Environment
Page 8 of 23
Page 9 of 23
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
150
nm/min.
151
2.3 Materials
152
Sodium sulfite anhydrous, potassium permanganate, sodium chloride, sodium
153
fluoride and sodium arsenite were obtained from Sinopharm Chemical Reagent Co.,
154
Ltd. Perchloric acid (70 %), stannous chloride, sulfuric acid, hydrochloric acid and
155
nitric acid were purchased from Kemiou Chemical Reagent Co., Ltd. Sodium sulfite
156
anhydrous, sodium chloride, sodium fluoride are guarantee reagent while others are
157
analytical grade. Mercuric oxide (the purity is higher than 99.9 %) as the source of
158
divalent mercury are analytical grade and obtained from Kaihua Chemical Reagent
159
Co., Ltd.
160
3. Results and discussion
161
3.1 Mercury re-emission in presence of arsenite
162
The arsenite ion is one of the most common ions in the scrubbing solutions for the
163
nonferrous metal smelting industry and easily accumulates at high levels due to the
164
recycling of scrubbing solutions. To test the effects of arsenite content on Hg0
165
re-emission, a series of corresponding experiments were conducted under different
166
arsenite concentrations ranging from 0 to 0.48 mM and the results are shown in
167
Figure 2 (the online date shown in Figure 2 are provided in the Supporting
168
Information). Individual arsenite ions can result in Hg0 re-emission. The presence of
169
arsenite at low concentrations could significantly increase Hg0 re-emission. As the
170
arsenite concentration increased from 0.03 to 0.12 mM, the total amount of
8
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 10 of 23
171
re-emission Hg0 over one hour rose from 15.86 to 48.92 µg. However, the Hg0
172
concentration in the outlet was inhibited obviously by a further increase in the arsenite
173
concentration. Additionally, to further determine mercury transfer paths in the
174
cleaning solution, the mass balances of mercury were performed based on the
175
determined results of the mercury concentration in solution before and after the
176
experiments. The results in Table S1 show that the measured mercury amount in the
177
flue gas is in good agreement with the difference value in solution between before and
178
after experiments, with a relative error of less than 2%, which further proves the
179
experimental accuracy.
180
The primary species of arsenite in the acidic scrubbing solution is H2AsO3- (see
181
Figure S1). At low arsenite concentrations, a portion of Hg2+ would be deoxidized to
182
Hg0 by H2AsO3-. In that case, the reaction path is listed as R1. Meanwhile, it has been
183
widely recognized that arsenite ions can easily combine with heavy metal ions to form
184
coordination complexes. Therefore, H2AsO3- could react with Hg2+ to form a stable
185
Hg(II)-As(III) complex at high arsenite concentrations. This may be the reason why
186
high arsenite concentrations inhibit Hg0 re-emission. The detailed intermediate
187
products and reaction mechanisms are presented in the following sections.
188
Hg 2+ + H 2 AsO 3 − + H 2 O = Hg 0 + HAsO 4 2 − + 3H +
9
ACS Paragon Plus Environment
(R1)
Page 11 of 23
2500 0 mM NaAsO2 0.03 mM NaAsO2
Hg0 con. (µg/m3)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
2000
0.06 mM NaAsO2 0.12 mM NaAsO2 0.24 mM NaAsO2
1500
0.48 mM NaAsO2
1000
500
0 0
10
20
30
40
50
60
T (min)
189 190
Figure 2. Effect of arsenite concentrations ranging from 0 to 0.48 mM on Hg0 re-emission.
191
Experimental conditions: [Hg2+] = 0.02 mM; solution volume= 300 mL; solution temperature =
192
35 °C; initial pH value = 9.0; N2 flow rate = 600 mL/min.
193
3.2 Effect of solution temperature
194
Generally, the temperature of the actual scrubbing solution is between 30~60 °C.
195
To evaluate the effect of temperature on Hg0 re-emission, several tests were conducted
196
with the solution temperature ranging from 25 to 65 °C. The results shown in Figure 3
197
demonstrate that the Hg0 re-emission could markedly increase with the solution
198
temperature. As the temperature increased from 25 to 65 °C, the Hg0 concentration
199
increased by several times, from approximately 352 to 950 µg/m3. This consequence
200
can be explained by the following reasons. The proton diffusion in liquid-gas could be
201
accelerated with the temperature increase. The redox reaction rate is also improved
202
due to the reduction of energy barriers at high temperature. Additionally, Littel R 31
203
reported that the increase of temperature could speed up the deprotonation process of
204
arsenite in accordance to R2, leading to the increase of Hg re-emission.
205
H 2 AsO 3− → HAsO 32 − + H + → AsO 33− + 2H + 10
ACS Paragon Plus Environment
(R2)
Energy & Fuels
2500
Hg0 con. (µg/m3)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 23
25 35 45 55 65
2000
1500
1000
500
0 0
10
20
30
40
50
60
T (min)
206 207
Figure 3. Effect of solution temperatures on Hg0 re-emission. Experimental conditions: [Hg2+] =
208
0.02 mM; [H2AsO3-] = 0.06 mM; solution volume = 300 mL; N2 flow rate = 600 mL/min; initial
209
pH value= 9.0.
210
3.3 Effect of solution pH
211
Figure 4 shows the Hg0 re-emission under different pH values. The results indicate
212
that the Hg0 re-emissions increased as the pH values increased from 2 to 12.
213
Interestingly, the outlet Hg0 concentrations differed greatly under acidic and alkaline
214
conditions. When the pH values were below 6, the Hg0 concentrations were less than
215
50 µg/m3, whereas the Hg0 concentrations exceeded 450 µg/m3 under alkaline
216
conditions. This outcome illustrates that pH has a great influence on Hg0 re-emission
217
in the presence of arsenite. This may be because the pH can greatly affect the
218
distribution of arsenite species in solution (see Figure S1). Under acidic conditions,
219
the H3AsO3 molecule is the primary species. With the increase of pH (6