Microbial Dynamics in Multi-Chamber Ozone Contactors at a Full-Scale Drinking Water Treatment Plant Nadine Kotlarz, Nicole Rockey, Terese M Olson, SarahJane Haig, Larry Sanford, John J. LiPuma, and Lutgarde Raskin Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b04212 • Publication Date (Web): 04 Jan 2018 Downloaded from http://pubs.acs.org on January 4, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 33
Environmental Science & Technology
Microbial Dynamics in Multi-Chamber Ozone Contactors at a Full-Scale Drinking Water Treatment Plant
Nadine Kotlarz†, Nicole Rockey†, Terese M. Olson†, Sarah-Jane Haig†, Larry Sanfordǂ, John J. LiPuma§, Lutgarde Raskin*,†
†
Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan
48109, United States ǂ
Drinking Water Treatment Utility, Ann Arbor, Michigan 48103, United States
§
Department of Pediatrics and Communicable Diseases, University of Michigan Medical School, Ann
Arbor, Michigan 48109, United States
*Corresponding author: Lutgarde Raskin Department of Civil and Environmental Engineering University of Michigan 1351 Beal Ave., 107 EWRE Bldg. Ann Arbor, MI 48109-2125 Phone: 734-647-6920 Email:
[email protected] ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 33
1
ABSTRACT
2
Concentrations of viable microbial cells were monitored using culture-based and culture-independent
3
methods across multi-chamber ozone contactors in a full-scale drinking water treatment plant. Membrane-
4
intact and culturable cell concentrations in ozone contactor effluents ranged from 1,200 to 3,750 cells/mL
5
and from 200 to 3,850 colony forming units/mL, respectively. Viable cell concentrations decreased
6
significantly in the first ozone contact chamber, but rose, even as ozone exposure increased, in subsequent
7
chambers. Our results implicate microbial detachment from biofilms on contactor surfaces, and from
8
biomass present within lime softening sediments in a hydraulic dead zone, as a possible reason for
9
increasing cell concentrations in water samples from sequential ozone chambers. Biofilm community
10
structures on baffle walls upstream and downstream from the dead zone were significantly different from
11
each other (p = 0.017). The biofilms downstream of the dead zone contained a significantly (p = 0.036)
12
higher relative abundance of bacteria of the genera Mycobacterium and Legionella than the upstream
13
biofilms. These results have important implications as the effluent from ozone contactors is often treated
14
further in biologically active filters and bacteria in those effluents continuously seed filter microbial
15
communities.
Page 2 of 27 ACS Paragon Plus Environment
Page 3 of 33
Environmental Science & Technology
16
INTRODUCTION
17
Ozone, a strong oxidant, is widely used for water treatment as it inactivates microbial pathogens,1
18
decomposes natural organic matter (NOM), removes taste-, odor- and color-causing compounds,2,3
19
oxidizes inorganic contaminants,4,5 and improves clarification and filtration by inducing formation of
20
precipitates or through reducing the stabilizing effects of NOM6. Wastewater treatment, drinking water
21
treatment, and water reuse plants have increasingly been including ozonation in their treatment trains to
22
achieve contaminant removal.7-12 Particularly, ozone’s use has increased in some European countries for
23
tertiary treatment of micropollutants in wastewater,13 in North America for drinking water treatment
24
where ozone application followed by biofiltration has increased 10-fold from 1993 to 2013,14 and in
25
several water scarce regions of the world where ozone combined with biofiltration has been explored as
26
an alternative to reverse osmosis for direct or indirect potable reuse (e.g., in Virginia,15 Australia,7
27
California16).
28
Ozone inactivation kinetics can be difficult to resolve in lab-scale experiments because ozone’s
29
fast reactivity results in non-detectable microbial levels after short ozonation times.17 Nevertheless, viable
30
microbial cells have been reported to remain present after ozonation of raw water18 or partially treated
31
water19-21 in full-scale and pilot-scale water treatment systems. A few reasons may explain the presence of
32
viable microorganisms in ozone contactor effluents. First, it is not surprising that different types of
33
microbes exhibit differential ozone resistance since the effectiveness of a disinfectant varies based on
34
variations in cellular and physiological features such as cell envelope composition and growth rate,22
35
growth state such as planktonic or biofilm growth,23,24 and nutrient availability25. In particular, some
36
opportunistic bacterial pathogens exhibit higher ozone resistance than other bacteria.22,26 Second,
37
disinfection in full-scale systems is often less effective than predicted by lab-scale inactivation
38
experiments because of matrix effects, such as the protection of microorganisms from disinfectant
39
exposure when present in flocs21 and lower than intended disinfection concentrations due to oxidant
40
demand exerted by NOM27 or inorganic compounds in untreated or partially treated water.
Page 3 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 4 of 33
41
Reduced disinfection efficiency is relevant for drinking water treatment plants (DWTPs) that
42
employ vertically baffled, multi-chamber ozone contactors. Nonideal flow conditions such as short-
43
circuiting and internal recirculation in such contactors can lead to insufficient mixing and reduced ozone
44
exposure.28 A combination of nonideal hydrodynamic conditions and the production of readily
45
biodegradable substrates through oxidation of NOM may increase the potential for biofilm formation on
46
contactor surfaces. Biofilm formation would present problems for disinfection since biofilm extracellular
47
polymeric substances (EPS) may shield microorganisms from ozone exposure and cells grown in biofilms
48
exhibit reduced sensitivity to disinfection.23,24 Surveys of microbial communities in full-scale DWTPs
49
19,21,29,30
50
in contactor influents and effluents only. Research is needed to elucidate factors that explain the presence
51
of viable microorganisms in ozone contactor effluents.
have treated ozone contactors as “black boxes,” focusing on the planktonic microbial community
52
In this study, viable microbial cell concentrations were monitored at five locations across multi-
53
chamber ozone contactors at a full-scale DWTP to gain insight into processes that shape the microbial
54
quality (i.e., microbial concentrations and community composition) of ozonated water. Furthermore, we
55
evaluated the bacterial community structures in sludge and in biofilms on baffle walls to generate
56
hypotheses for how nonideal flow conditions influence the microbial community in ozone contactor
57
effluent.
Page 4 of 27 ACS Paragon Plus Environment
Page 5 of 33
Environmental Science & Technology
58
MATERIALS AND METHODS
59
Drinking Water Treatment Plant. The maximum capacity of the DWTP in Ann Arbor, MI is 50 million
60
gallons per day (MGD) (1.9 × 105 m3/day) and the average daily water production is 15 MGD (5.7 × 104
61
m3/day). Pinto et al. previously provided a description of the Ann Arbor DWTP.30 Briefly, raw water is
62
obtained from the Huron River (80-85%) and from groundwater wells (15-20%) and is treated using lime
63
softening, coagulation, flocculation, sedimentation, ozonation, filtration, and chloramination. Before
64
ozonation, CO2 contactors reduce the pH of the water to approximately 7.8 (mean pH was 7.8 ± 0.4 for
65
December 2015 through December 2016). Ozonated water is applied to biologically active, dual media
66
filters containing granular activated carbon and sand.
67
Ozone Contactors. The Ann Arbor DWTP has four parallel ozone contactors each containing seven
68
chambers separated by vertical baffle walls and inlet and outlet basins (Figure 1). Two of the four
69
contactors are typically operated to meet water demand. Onsite ozone generators are fed oxygen and
70
produce a gas stream with approximately 7-10% ozone. Ozone is dispersed by ceramic fine bubble
71
diffusers into chambers 2 and 3 of each contactor. Specifically, 70% of the ozone generated is dispersed
72
into chamber 2 and 30% is dispersed into chamber 3. Water flows by gravity counter-currently to the
73
ozone in chamber 2 and co-currently in chamber 3. A sufficient ozone dose is added to maintain 0.1 mg/L
74
ozone residual in the effluent of chamber 2 to achieve 1-log virus inactivation credit under the United
75
States Environmental Protection Agency (U.S. EPA) Surface Water Treatment Rule. The effluent of the
76
seventh chamber in each contactor flows over a weir to dissipate dissolved gases, and water from the two
77
contactors in operation is mixed in an outlet basin.
78
In each contactor, five sample lines extend from the contactor chambers to an ozone analyzer
79
(Figure 1). Samples collected from sample line 1 represent clarified water after pH adjustment but before
80
ozone exposure (CT = 0). Samples from sample lines 2, 3, and 4 represent water after contact with ozone
81
gas in chambers 2 and 3, and water after exposure to any residual ozone in chamber 4 and the outlet basin,
82
respectively. The residence time for a complete contactor is approximately 10 min (average was 9.8 ± 1.3
83
min across sampling events for heterotrophic plate count and flow cytometry analyses). The length of Page 5 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 33
84
chamber 3 (i.e., the distance between consecutive baffle walls) is twice the length of the other chambers.
85
While uniform chamber sizes are most common in ozone contactors, some contactor designs provide
86
larger chambers for ozone dissolution. The co-current flow in chamber 3 is hydraulically less optimal
87
relative to the counter-current flow in chamber 2.31 Longer chamber length provides additional contact
88
time in chamber 3.
89
Sample Collection. Water samples were collected from three contactors over the course of a year (Table
90
S1). Before sample collection, each sample line was flushed until meter readings of ozone concentration
91
were stable (approximately 3 min). 500 mL water samples were collected into sterile Nalgene
92
polypropylene bottles containing sodium thiosulfate (5 × stoichiometric requirement (SR)17,32 to quench
93
0.5 mg/L ozone) from each sample line. Separate 500 mL samples were collected into sterile, carbon-free
94
amber bottles containing sodium thiosulfate for assimilable organic carbon (AOC) analyses by Eurofins
95
Eaton Analytical (described below).
96
Ozone Exposure (CT) Calculation Method. Ozone concentration and temperature were monitored in
97
each sample line by online Ozone 499A OZ Sensors. The ozone exposure or CT (concentration × time)
98
for each chamber was calculated as the average ozone concentration (C) in the chamber multiplied by the
99
T10. The U.S EPA Surface Water Treatment Rule designates T10 as the time it takes for 10 percent of a
100
tracer to exit a disinfection contactor. For reaction chambers 4-7 (no ozone addition), a first order ozone
101
decay model was used to determine the average ozone concentration. Residual ozone concentrations at
102
sample line 5 (in the outlet basin) were typically below the quantification limit (0.01 mg/L). The CT
103
calculation method is described in detail in the Supporting Information (Table S2).
104
Heterotrophic Plate Counts (HPC). HPC were conducted using the pour plate method according to
105
Standard Methods 9215 B.33 Samples were diluted (1:100, 1:10; 1:5, or 1:2 depending on the sample)
106
with sterile phosphate buffered saline (PBS, pH = 7.2 ± 0.2) solution and 1 mL diluted sample was mixed
107
with liquefied R2A agar in triplicate and plated (n = 6 plates per sample). Colony forming units (CFUs)
108
were counted using a Quebec Darkfield Colony Counter (Reichert, Inc., Depew, NY) after seven days of
109
incubation at 28 °C. Ratios of culturability were calculated for water from sample lines 1 and 5, for each Page 6 of 27 ACS Paragon Plus Environment
Page 7 of 33
Environmental Science & Technology
110
of the two days when HPC and flow cytometry methods (described below) were both used. The values
111
reported in the manuscript are the mean ± range for sample lines 1 or 5 across the two days.
112
Taxonomic Classification of Isolates. For one of the sampling days, 190 isolates were cut from R2A
113
plates for taxonomic analysis of culturable populations. More information is provided in the Supporting
114
Information (Figure S5).
115
Flow Cytometry Analysis. Sample aliquots (1 mL) were stained with propidium iodide (PI,
116
ThermoFisher Scientific, Waltham, MA) and SYBR Green I (SGI, ThermoFisher Scientific) at final
117
concentrations of 3 µM PI and 1X SGI. After staining, samples were incubated at 37°C for 15 min to
118
improve cell staining.34,35 CountBrightTM absolute counting beads (Life Technologies, Carlsbad, CA) were
119
added to each sample per the manufacturer’s instructions to determine flow cytometer process volume.
120
All samples were stained and analyzed in duplicate and stored on ice until analysis with an LSR Fortessa
121
cell analyzer (BD Biosciences, San Jose, CA). Events were triggered off fluorescence in the SGI or PI
122
channels above a threshold of 200. For each sample, forward and side-scatter as well as fluorescence in
123
the 610/10, 530/30, and 780/60 nm wavelengths were measured for detection of PI positive, SGI positive,
124
and bead events, respectively. At least 10,000 events were collected for each sample, and no
125
compensation was applied to sample measurement. Data analysis was carried out using FlowJo software
126
(FlowJo, Ashland, OR). Electronic gating of events in a density plot of SGI and PI fluorescence channels
127
was used to determine the number of events positive for SGI and negative for PI (membrane-intact cells).
128
Organic Carbon Analysis. Each quenched sample was filtered through sterile 0.45 µm nylon syringe
129
filters (ThermoFisher Scientific) previously washed with 40 mL MilliQ water and 10 mL of sample, and
130
the filtrate was frozen for dissolved organic carbon (DOC) analysis with a Total Organic Carbon
131
Analyzer TOC-V CSH (Shimadzu, Columbia, MD).
132
Samples were submitted to Eurofins Eaton Analytical (South Bend, IN) for AOC analysis
133
according to Standard Methods 9217B.33 At Eurofins Eaton Analytical, water samples were aliquoted into
134
vials (40 mL each) and pasteurized (70-80 °C for 30 min). Spirillum NOX and Pseudomonas fluorescens
135
P-17 strains, which have different substrate specificities, were inoculated into each vial at an initial Page 7 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 33
136
concentration of 500 CFU/mL and then incubated at 25 °C. Growth in each vial was determined on R2A
137
agar plates in duplicate on days 5, 6 and 7 (n = 6 plates per sample). Average CFU was converted into
138
AOC concentration based on the growth yields of the NOX and P-17 strains for acetate (4.1 × 106 and 1.2
139
× 107 CFU/µg acetate-C for P17 and NOX, respectively). AOC determined by P-17 growth and AOC
140
determined by NOX growth were added and expressed as the total sample AOC.
141
Contactor Shutdown Experiment. Water flow and ozone supply for one of the contactors were turned
142
off. Samples were collected from chambers 2 and 3 before shutdown, and 2 h and 9.45 h after shutdown
143
for HPC and flow cytometry analyses as described above. The ozone contactor was kept dark and
144
relatively full during shutdown. Immediately after shutdown, water from chamber 2 was collected into a
145
sterile glass bottle protected from light and kept at room temperature to serve as an experimental control,
146
representing the bulk water in the contactor but without exposure to contactor surfaces. After shutdown,
147
the contactor could be considered a batch system, resulting in a low rate of microbial cell diffusion into
148
the bulk water, motivating the selected sampling time points on the order of hours (2 h and 9.45 h).
149
Residual ozone concentrations were monitored in chamber 2 by online Ozone 499A OZ Sensors.
Page 8 of 27 ACS Paragon Plus Environment
Page 9 of 33
Environmental Science & Technology
150
Ozone Contactor Biofilm and Sludge Samples. After the shutdown experiment, the contactor was
151
drained and, for safety purposes, ozone was allowed to degas from the concrete walls for two weeks
152
before we entered the contactor. Biofilm was swabbed from specific areas (18.8 cm2 each) on baffle
153
walls, at about 1.5 m from the floor, from chambers 2-5. Duplicate biofilm samples, collected for 3 out of
154
5 wall locations sampled, were swabbed next to each other. Biofilm from one diffuser in chamber 3 (n =
155
1) was collected. Each swab was placed in sterile PBS. Swabs were vortexed for 2 min and sonicated for
156
2 min in an ultrasonicator (ThermoFisher Scientific) to release biomass. The biomass was filtered onto
157
0.2 µm polycarbonate filters (Millipore) and filters were stored at -80 °C. Sludge from a hydraulic dead
158
zone in chamber 3 (n = 1), the chamber where sludge accumulation was the greatest, was collected into a
159
sterile Falcon tube (Corning, Corning, NY) and stored on ice for up to 1 h before storage at -80 °C. A
160
hydraulic dead zone is a zone of insufficient mixing resulting from internal recirculation inside the
161
chamber.36
162
Total DNA was extracted from biofilm and sludge samples using a modified recipe of the
163
Universal Extraction Lysis Buffer and a phenol-chloroform-isoamyl extraction protocol37,38 to improve
164
recovery of difficult-to-lyse bacteria. The controls were processed in parallel with the samples. PCR,
165
sample multiplexing, and Illumina MiSeq sequencing of partial 16S rRNA genes were performed by the
166
Microbial Systems Laboratory at the University of Michigan Medical School (Ann Arbor, Michigan).
167
Barcoded dual-index primers specific to the V4 region of the 16S rRNA gene39,40 were used to amplify
168
the DNA. PCR reactions included 5 µL of 4 µM forward and reverse primers, 0.15 µL of AccuPrime Taq
169
DNA High Fidelity Polymerase (Life Technologies), 2 µL of 10x AccuPrime PCR Buffer II
170
(ThermoFisher Scientific), 1 µL of DNA template, BSA (0.5 mg/mL final concentration), and nuclease-
171
free water. PCR conditions consisted of 2 min at 95 °C followed by 30 cycles of 95 °C for 20 s, 55 °C for
172
15 s, 72 °C for 5 min, followed by 72 °C for 10 min. Sequencing was done on the Illumina MiSeq
173
platform using a MiSeq Reagent Kit V2 500 cycles according to the manufacturer’s instructions with
174
some modifications.39
Page 9 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 10 of 33
175
16S rRNA gene sequences from all samples were curated using mothur (version 1.39.0).41
176
Sequences that were within two nucleotides of each other were merged using the pre.cluster command.
177
After preclustering, 439 sequences in the control samples (putative contaminants) were removed from the
178
6,429 unique sequences in the dataset using the remove.seqs command (6.8% sequences removed).
179
Curated sequences (131,264 total sequences) were clustered into OTUs using a 97% similarity cutoff with
180
the opticlust algorithm.42 Subsampling was performed based on the sample with the lowest number of
181
sequences, resulting in 4,387 paired-end reads per sample.39 Sequences were classified using a naïve
182
Bayesian classifier43 trained against a 16S rRNA gene training set provided by the RDP.44 An RDP
183
consensus taxonomy was generated for each OTU.
184
Thermal Gravimetric Analysis (TGA) of Sludge. TGA analysis was performed to estimate the
185
composition of contactor sludge. A sample of the sludge was weighed, dried in an oven at 103 °C for 1 h
186
and weighed again to determine water loss. The sludge was subject to TGA in an oxygen atmosphere. The
187
temperature was ramped up from ambient to 800 °C at a rate of 10 °C min-1 in a TA Q500 (TA
188
Instruments, New Castle, DE). Continuous online records of weight loss and temperature were used to
189
plot a derivative TGA curve.
190
Statistical Analyses. Results are reported as the mean ± standard deviation unless otherwise noted.
191
Statistical significance was based upon the probability of p < 0.05. A Wilcoxon test was used for
192
comparison of cell concentrations. An Analysis of Molecular Variance (AMOVA) was used to test for
193
significant separation of samples on the NMDS plot. A Pearson correlation coefficient was used for the
194
correlation analysis with individual OTUs and shifts in samples along axes in the NMDS plot.
Page 10 of 27 ACS Paragon Plus Environment
Page 11 of 33
Environmental Science & Technology
195
RESULTS
196
Because the Ann Arbor DWTP did not operate the same ozone contactors throughout the sampling
197
campaign, water samples were collected from three contactors on different days (Table S1). Plant
198
operators change ozone feed gas concentrations and influent flow rates through the contactors daily and
199
this contributed to the variability in ozone CT profiles across the sampling days (Figure 1). Therefore,
200
viable cell concentrations are plotted against sample line numbers (1-5) instead of ozone CT. The average
201
cumulative ozone CT was 0.96 ± 0.32 mg-min/L across eight sampling days (Figure 1).
202
Cell Concentrations Across Ozone Contactors. Culturing and culture-independent flow cytometry were
203
used to monitor microbial communities during ozone disinfection in multi-chamber contactors. Figure 2
204
shows viable cell concentrations measured by culturing and culture-independent flow cytometry. HPC
205
based inactivation monitoring indicated 1.88 ± 0.47 log reduction from 1,110 ± 420 CFU/mL before
206
ozonation to 17 ± 19 CFU/mL in chamber 2, the first chamber where ozone contact occurs (ozone
207
exposure of 0.26 ± 0.06 mg-min/L; Figure 1) (Figure 2a). As expected, greater numbers of intact cells
208
were measured using flow cytometry than with HPC. However, a similar log reduction of 1.86 ± 0.19 was
209
observed from 106,000 ± 31,000 intact cells/mL before ozonation to 1,610 ± 730 intact cells/mL in
210
chamber 2 (Figure 2b). The levels of culturable and membrane-intact cells increased in the third chamber,
211
even as ozone exposure increased by 0.63 ± 0.17 mg-min/L (Figure 1). Specifically, in chamber 3, there
212
was a significant (p < 0.0001) increase in the level of culturable cells to 750 ± 350 CFU/mL, and the level
213
of intact cells increased to 2,700 ± 1,100 cells/mL (p = 0.05). Intact cell concentrations increased further
214
in chamber 4 (p = 0.05), but culturable cell concentrations did not increase significantly. In spite of
215
increasing intact cell concentrations in chambers 3 and 4 on most days (Figure S1b), ozonation
216
significantly reduced intact cell concentrations overall (1.62 log reduction, p = 0.0001), with
217
concentrations ranging from 1,200 to 3,750 intact cells/mL in water from the outlet basin (sample line 5).
218
The levels of culturable bacteria in the outlet basin ranged over an order of magnitude, from 200 to 3,850
219
CFU/mL. In comparison with cell concentrations before ozonation (sample line 1), there was a slight
220
reduction in culturable cells after ozonation (sample line 5) on three sampling days, but a significant (p < Page 11 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 12 of 33
221
0.0001) increase in CFU concentrations after ozonation in one of the contactors sampled on three
222
different days during one week (Figure S1a). The culturability (i.e., the ratio of HPC to membrane-intact
223
cells) of water samples before ozonation was 0.9 ± 0.4% (mean ± range) but increased 12-fold to 10.4 ±
224
7.8% after ozonation (Figure S2).
225
Microbial Growth Substrates. Dissolved organic carbon (DOC) levels did not change significantly
226
during ozonation (p = 0.08) (Figure S3). The average concentration of DOC across the five sampling lines
227
was 4,000 ± 300 µg/L.. However, AOC levels increased significantly (p < 0.0001) after ozone exposure
228
began in chamber 2. The average AOC level was 36 ± 0.3 µg/L (mean ± range across two sampling
229
events) before ozonation and increased to 115 ± 12 µg/L (mean ± range) after ozonation. The increase in
230
AOC was caused by an increase in growth substrates specific for the Spirillum NOX strain, which
231
primarily uses carboxylic acids as growth substrates45.
232
Cell Concentrations after Contactor Shutdown. A “no flow” (batch) experiment was conducted in a
233
contactor to test whether walls and accumulated solids were the source of increasing cell concentrations
234
in the bulk water. Cell concentrations were monitored in stagnant water in chambers 2 and 3 after influent
235
water and ozone gas supply were shut off. Chambers 2 and 3 were chosen since chamber 2 is the contact
236
chamber where the greatest reduction in viable cell levels occurred and chamber 3 is where cell
237
concentrations increased (Figure 2). Immediately after contactor shutdown, water was collected from
238
chamber 2 and incubated at room temperature in the dark to serve as a control with the same planktonic
239
cell concentration and growth substrate level as the stagnant water in chamber 2 at the start of the
240
experiment. An increase in cell concentrations in the control would be explained by planktonic cell
241
growth or recovery, not detachment of cells from biofilm or sediments.
242
Residual ozone concentrations dropped to below quantification (0.01 mg/L) after 12 min in
243
chamber 2 (Figure S4). The initial CFU and intact cell concentrations in chamber 2 were 10 ± 4 CFU/mL
244
and 1,660 ± 110 intact cells/mL, respectively. The CFU concentration in chamber 2 increased
245
substantially to 800 ± 210 CFU/mL 2 h after shutdown, and then increased further to 4,800 ± 1,300
246
CFU/mL 9.5 h after shutdown (Figure 3a). The concentration of intact cells in chamber 2 increased Page 12 of 27 ACS Paragon Plus Environment
Page 13 of 33
Environmental Science & Technology
247
similarly (Figure 3b). The initial CFU and intact cell concentrations in chamber 3 were 600 ± 50 CFU/mL
248
and 1,400 ± 20 intact cells/mL, respectively. The CFU concentration in chamber 3 decreased to 160 ± 20
249
CFU/mL 2 h after shutdown, but then increased to 6,010 ± 1,800 CFU/mL 9.5 h after shutdown (Figure
250
3a). The concentration of intact cells in chamber 3 increased consistently at 2 and 9.5 h after shutdown
251
(Figure 3b). In contrast, the concentration of culturable cells in the control decreased and was below
252
detection after 2 h and remained below detection during the 9.5 h experiment. The levels of membrane-
253
intact cells in the control decreased slightly to 820 ± 30 intact cells/mL after 2 h, and then increased to
254
3,890 ± 4,400 intact cells/mL after 9.5 h (Figure 3b).
255
Taxonomic Classification of Isolates. The colonies on R2A plates generally became smaller and more
256
uniform (mostly white colonies) in water sampled from sequential chambers (Figure S5). Table 1 shows
257
taxonomic classification at the genus level of 190 isolates based on 16S rRNA gene sequencing.
258
Pseudomonas, Blastomonas and Limnobacter spp. predominated among the strains cultured from water
259
before ozone exposure (CT = 0 mg-min/L). The relative abundance of Pseudomonas strains decreased
260
and Blastomonas strains were not detected after ozone exposure began (CT = 0.30 mg-min/L), whereas
261
the relative abundance of Limnobacter strains increased substantially to greater than 80% after ozone
262
exposure began. Other bacteria cultured from water in the outlet basin (sample line 5) included
263
Hydrogenophaga strains and unclassified Comamonadaceae spp. Isolates obtained from water before
264
ozonation belonged to Alphaproteobacteria, Betaproteobacteria, and Gammaproteobacteria, but strains
265
isolated after ozonation began were mostly Betaproteobacteria and, by the end of ozonation, all cultured
266
populations were Betaproteobacteria.
267
Biofilm and Sludge Samples. Partial 16S rRNA gene sequencing of biofilms on walls in chambers 2
268
through 5 indicated that some taxa cultured from water samples collected during ozonation were also
269
detected in the biofilm samples. For example, an OTU classified as Limnobacter (OTU0004) was present
270
in biofilm sampled from the wall in chamber 2 (1.4% relative abundance), and its relative abundance was
271
substantially higher in biofilm on the left wall of chamber 3 (29%) (Table S5). This OTU was also present
Page 13 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 14 of 33
272
in biofilm on a diffuser in chamber 3 (2.1% relative abundance). However, Limnobacter spp. were not
273
detected in biofilm samples on the right wall in Chamber 3, or in biofilm samples from chambers 4 and 5.
274
Sludge had accumulated near the right wall in chamber 3 and TGA of a sludge sample (Figure
275
S6) showed significant weight loss occurred between 542 and 830 °C, corresponding to the decarbonation
276
of calcium carbonate46. This finding suggests sludge accumulation was due to incomplete removal of
277
calcium carbonate during lime softening. Smaller weight losses during TGA occurring at 502 °C and
278
between 183 and 407 °C may have corresponded to dihydroxylation of calcium hydroxide and
279
volatilization of organic content, respectively.47,48
280
DNA yields from baffle wall biofilm samples after the dead zone were significantly higher than
281
those before the dead zone (p = 0.036) (Table S3). Furthermore, non-metric multidimensional scaling of
282
ϴyc distance ordinations indicated that the biofilm community structures of samples collected before and
283
after the dead zone clustered separately (Figure 4), and the separation was statistically significant (p =
284
0.017). An OTU (OTU0001) classified as Gp4 in Acidobacteria became significantly more abundant in
285
biofilm samples after the dead zone (p = 0.036). The relative abundance of this OTU was significantly
286
correlated with a shift in the biofilm community structure along NMDS axis 1 (p = 0.002), shifting from
287
the community structure before the dead zone toward the community structure after the dead zone (Figure
288
4). In addition, the relative abundance of OTUs classifying as Mycobacterium and Legionella, two genera
289
that contain species of public health importance as opportunistic pathogens, increased significantly in
290
biofilm samples after the dead zone (p = 0.036 and p = 0.036 for Mycobacterium and Legionella,
291
respectively) (Figure 5). The bacterial community in the sludge that accumulated near the right baffle wall
292
in chamber 3 contained sequences classified as Gp4 OTU0001 (1.5% relative abundance) as well as
293
Mycobacterium and Legionella (0.41% and 2.4% relative abundance, respectively) (Figure 6). The
294
Shannon diversity indices of biofilms from baffle walls varied between 3.1 and 4.5 (mean of 4.02 ± 0.45,
295
Table S4), whereas the Shannon diversity indices of biofilm from a diffuser and from the sludge in
Page 14 of 27 ACS Paragon Plus Environment
Page 15 of 33
Environmental Science & Technology
296
chamber 3 were 5.2 and 5.0, respectively. Shannon evenness ranged from 0.58 to 0.86 across all samples,
297
with the sludge bacterial community being the most even.
298
DISCUSSION
299
Viable cell concentrations. The overall level of inactivation across each contactor, as determined by
300
culture-independent flow cytometry, was higher than inactivation measured by culture-based methods.
301
Across the contactors, 1.62 log reduction of membrane-intact cells was observed on average (Figure 2b),
302
which is consistent with 1-2 log reductions of membrane-intact cells, as measured by flow cytometry,
303
reported for ozonation (0.33-0.35 mg O3/mg C) of partially treated raw waters in two other full-scale
304
DWTPs49. However, on days when HPC levels were reduced across the contactors, the reductions
305
observed (0.32 ± 0.05 log for April 22, Oct 4, Oct 19, 2016) were lower than those reported for a pilot-
306
scale ozone contactor column (1.5 log)50 and a baffled ozone reactor treating secondary wastewater
307
effluent (1.4-1.6 log)21. The greater culturability of the bacteria in water samples after ozonation (Figure
308
S2) may have contributed to the modest reductions in HPC levels observed. The potential for changes in
309
culturability to impact estimates of microbial reductions is one reason why flow cytometry was used in
310
addition to HPC to enumerate viable cells. HPC levels in contactor effluents were sometimes higher than
311
influent levels (May 5, 9, 13, 2016; Figure S2). At a DWTP in the Netherlands, levels of heterotrophic
312
bacteria isolated on conventional plate count agar increased after ozonation, although the increase was not
313
observed when R2A agar was used.49 A major limitation of culture-based studies is that only a small
314
proportion of viable cells are amenable to cultivation. Therefore, HPC may not be as responsive to
315
changes in bacterial abundance as culture-independent methods such as flow cytometry.51-53 The observed
316
increase in HPC and intact cell concentrations in chamber 3 and subsequent chambers indicates that
317
microbial growth occurred or that viable cells were introduced to the water through another mechanism.
318
Most of the overall reduction of viable cells occurred in the first ozone contact chamber (chamber
319
2), where an approximate 2-log reduction of HPC and intact cell concentrations was observed. An
Page 15 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 16 of 33
320
investigation of bacterial concentrations at the same plant conducted three months after ozonation was
321
implemented reported 2.6-log reduction of HPC determined by culturing on R2A agar (5.43 × 103
322
CFU/mL in contactor influent to 13 CFU/mL in effluent).19 Results of this earlier study taken together
323
with our findings suggest the reductions originally achieved over the full contactor length were
324
constrained to the first ozone contact chamber. While the first contact chamber provides a disinfection
325
barrier to microorganisms present in the partially treated raw water given the significant reduction in
326
viable cells (Figure 2a and 2b) observed after chamber 2, our data suggest that characteristics of chambers
327
3-7 shape the microbial quality of the water exiting the contactors.
328
Biofilm Detachment. The increase in viable cell concentrations after the first contact chamber cannot be
329
attributed to planktonic cell growth considering the short residence time in the contactors (approximately
330
10 min). The doubling rates required to produce such an increase would be much shorter than the fastest
331
doubling rates reported for microorganisms (e.g., 9.8 min for Vibrio natriegens54). Within 2 h of shutting
332
off water flow and ozone gas supply, HPC and intact cell concentrations increased in chambers 2 and 3,
333
but not in a control (Figure 3), suggesting that the interaction of bulk water with contactor surfaces or
334
accumulated solids was necessary to produce the increasing cell concentrations observed.
335
The contactors are made from poured concrete. Carbonation, i.e., the replacement of calcium
336
hydroxide with calcium carbonate, reduces the pH of concrete over time55 thereby resulting in more
337
favorable conditions for biofilm formation. Passive biofilm detachment from contactor surfaces may
338
occur continuously by erosion56 or through discrete detachment events (i.e., sloughing),56,57 and may be
339
due to shear created by fluid moving past the biofilm58 and/or an increase in detachment rate caused by
340
higher growth rates due to greater AOC availability59. Had shear-based detachment been important,
341
higher effluent cell concentrations would have been expected with increased flow through a contactor.
342
However, the times when effluent CFU concentrations were greatest (May 5, 9, 13, 2016; Figure S2) did
343
not correlate with days when the plant was operating at higher flowrates (Table S1). Instead, microbial
344
levels in bulk water increased quickly under stagnant conditions (Figure 3). AOC in contactor influent
Page 16 of 27 ACS Paragon Plus Environment
Page 17 of 33
Environmental Science & Technology
345
and AOC generated in chamber 2 (Figure S3) provided a continuous supply of biofilm growth substrates.
346
The results support a scenario whereby AOC generated by ozonation provides growth substrate for
347
biofilm formation on contactor surfaces. Subsequently, biofilm detaches, thereby increasing planktonic
348
cell concentrations in contactor effluents.
349
Biofilm community structure. Results from the contactor shutdown experiment, and other evidence
350
discussed above, suggest that biofilm detachment may be responsible for the presence of microorganisms
351
detected in water samples. This underlines the importance of understanding the factors that shape the
352
microbial community structure of biofilms on contactor surfaces to control microbial quality of the
353
effluent. Biofilm microbes may have cellular and physiological features that facilitate their resistance to
354
ozone exposure. Additionally, biofilm EPS and carbonate on contactor surfaces may serve to protect
355
microorganisms from ozone and ozone decomposition products, respectively, as carbonate is an effective
356
hydroxyl radical scavenger60.
357
Recent research has focused on the potential for enrichment of disinfectant resistant,
358
opportunistic pathogenic bacteria through disinfection processes in water treatment.61,62 We detected
359
Mycobacterium and Legionella OTUs in biofilm samples from contactor walls in chamber 2, where the
360
highest ozone residuals were applied. Their resistance to ozone would be consistent with lab-scale
361
inactivation experiments demonstrating that certain Legionella and Mycobacterium species (e.g.,
362
Legionella pneumophila63 and Mycobacterium avium22) are more resistant to ozone exposure than E. coli.
363
The finding that ozonation of a wastewater treatment plant effluent selected for bacteria with high
364
genomic guanine-cytosine (GC) content is relevant for ozone selection of Mycobacterium species, which
365
have GC rich genomes.64 While we did not culture Mycobacterium spp. from the ozonated water samples,
366
in an earlier study performed shortly after the plant began ozonating, Mycobacterium was the most
367
common group and comprised 31% of bacterial isolates identified after ozonation.19 These results raise
368
the possibility that the presence of Legionella and Mycobacterium spp. in biofilm on contactor walls was
369
related to their resistance to ozone and not solely their protection from ozone exposure.
Page 17 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 18 of 33
370
Smaller colony sizes after ozone contact in chamber 2 (Figure S5) would be consistent with the
371
view that ozone exposure selected for disinfectant-resistant microorganisms as bacteria with lower
372
specific growth rates often exhibit higher resistance to stress,22,65,66 although this is not always the case23.
373
However, the ozone resistance of the cultured microorganisms was not tested in this study. Ozone
374
inactivation experiments are needed to confirm ozone resistance of microorganisms in contactor effluents.
375
Furthermore, given the range of viable cell concentrations we observed in contactor effluents,
376
fluorescence activated cell sorting of viable populations71 combined with amplicon sequencing could be
377
used for identification of viable cells in ozonated water. While the observed enrichment for Limnobacter
378
spp. in this study was consistent with their detection in biofilms from water distribution networks67,68 and
379
premise plumbing,69 their resistance to ozone is unknown since ozone inactivation kinetics for
380
Limnobacter spp. have not been reported. However, in a recent study, the relative abundance of
381
Limnobacter increased significantly in a surface water disinfected with photocatalytic ozonation.70 We
382
had expected that Limnobacter would be present in all biofilm samples based on its predominance among
383
isolates from contactor water samples (Table 1), but the community structure of biofilm samples on
384
contactor walls past a dead zone in chamber 3 was substantially different from those in chamber 2
385
(discussed below). The water samples for culturing were collected from a contactor in operation whereas
386
biofilm samples were collected from a contactor that had been taken out of operation. This contactor was
387
chosen for shutdown because ozone demand was unusually high. Upon inspection, we observed an
388
accumulation of sludge in the contactor, which may have caused the high ozone demand. It is likely that
389
this sludge had a greater impact on the biofilm community structure of the baffle walls in this contactor
390
than in the contactor from which water samples had been collected for culturing.
391
Dead zone effects. The length of chamber 3 is double the length of chamber 2 to provide for additional
392
disinfectant contact time. As the water velocity through chamber 3 decreases, more sediments are
393
deposited in chamber 3. This greater length is also expected to increase internal recirculation inside the
394
chamber and result in zones of insufficient mixing (dead zones).28 The accumulation of sludge observed
395
near the right baffle wall in chamber 3 was in a location predicted to be a dead zone by modeling of flow Page 18 of 27 ACS Paragon Plus Environment
Page 19 of 33
Environmental Science & Technology
396
through multi-chamber contactors.28 This sludge accumulation, and our data suggesting the presence of
397
biomass in the sludge, may be one way viable cells were introduced to the water in chamber 3.
398
Furthermore, the significantly different biofilm community structure past the dead zone raises the
399
possibility that microorganisms in sludge in the dead zone seeded biofilms downstream. However, it is
400
possible there was a greater impact of sludge on the biofilm community structure of baffle walls in this
401
contactor than in the contactor from which water samples for culturing were collected. Although lime
402
softening precipitates are expected to have a high pH unfavorable for microbial life, the Shannon diversity
403
of the bacterial community in a sludge sample from one dead zone was relatively high (5.0 ± 0.01, Table
404
S4), possibly due to the rapid decomposition of ozone when exposed to the high surface pH of the lime
405
softening precipitates, thus providing protection of microorganisms from ozone exposure. This notion
406
raises the possibility that sludge in dead zones harbor microorganisms that present a public health risk.
407
The presence of Mycobacterium and Legionella OTUs in sludge, and an increase in their relative
408
abundance in biofilms past the dead zone, suggest that adverse microbial effects of dead zones are an
409
argument for improving hydraulic efficiency in multi-chamber contactors by decreasing chamber length,
410
in spite of greater energy requirements to drive flow over and under more baffle walls36. Therefore,
411
chamber length should be an important feature for contactor design. Additionally, use of materials that are
412
less reactive with ozone and do not quench hydroxyl radicals (e.g., acidic materials) in contactor
413
construction may minimizes biofilm formation on contactor surfaces. As retrofitting ozone contactors is
414
not an option for many existing DWTPs, other options need to be considered to improve ozone
415
disinfection efficiency. Strategies that focus on increasing ozone dose to avoid biofilm formation need to
416
consider undesirable ozonation byproducts such as bromate72 and nitrosamines73. Better pretreatment
417
before ozonation and more frequent contactor cleanings are obvious strategies to reduce the effects of
418
sediments entering the ozone contactor in the present study. Our findings from one contactor need to be
419
confirmed with sampling campaigns in other full-scale, multi-chamber ozone contactors.
Page 19 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 20 of 33
420
While previous research has shed light on the importance of biofilms in determining microbial
421
water quality in distribution systems,74 our results provide a new appreciation for the potential role of
422
biofilm detachment in determining multi-chamber ozone contactor effluent water quality. Our findings
423
suggest implications for post-ozonation processes as ozone contactors may serve as an important seed
424
source of microorganisms to downstream biofilters. More research is needed to understand the interplay
425
between ozonation and biofiltration, two unit processes that may represent critical control points for
426
drinking water microbial quality30,75,76.
Page 20 of 27 ACS Paragon Plus Environment
Page 21 of 33
Environmental Science & Technology
427
ACKNOWLEDGEMENTS
428
We thank James Yonts, Ryan Justin, Jeff Keown, Matt Brown, Mike Switzenberg, Aaron Buza, Duane
429
Weible, Wendy Schultz and Brian Steglitz for assistance with sampling and data collection; Michael
430
Pihalja, Aaron Robida, Krista Wigginton, and Frederik Hammes for helpful discussions; and Johannes
431
Schwank, Xiaoyin Chen and Yun Shen for assistance with TGA analysis. We also thank anonymous
432
reviewers for their valuable feedback. Partial funding for this work was provided by the Cystic Fibrosis
433
Foundation and the University of Michigan MCubed Program. NK was supported by Dow Sustainability,
434
Rackham Merit and Integrated Training in Microbial Systems (ITiMS) Fellowships from the University
435
of Michigan (UM). The ITiMS program “Instructional Program Unifying Population and Laboratory
436
Based Sciences” at UM was funded by the Burroughs Wellcome Fund. NR was partially supported by a
437
U.S. National Science Foundation Graduate Research Fellowship. SJH was supported by Alfred P. Sloan
438
Foundation, Microbiology of the Built Environment (G- 2014-13739) and UM Dow Sustainability
439
Fellowships.
Page 21 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 22 of 33
440
SUPPORTING INFORMATION
441
Supporting Information for this study is provided and includes an overview of ozone contactors sampled,
442
description of the method used to determine ozone exposure, results of HPC analyses for each sampling
443
day, HPC and flow cytometry measurements on two days, results of organic carbon analyses, residual
444
ozone measurements after contactor shutdown, results of thermal gravimetric analysis of sludge, DNA
445
extraction yields and diversity estimates for biofilm and sludge samples, and taxonomy and relative
446
abundance of the top 10 most abundant OTUs in biofilm and sludge samples.
447
Page 22 of 27 ACS Paragon Plus Environment
Page 23 of 33
Environmental Science & Technology
448 449
References
450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494
1. 2. 3.
4. 5.
6. 7.
8.
9.
10.
11.
12.
13.
14. 15.
16.
Hunt, N. K. Mariñas, B. J. Inactivation of Escherichia coli with ozone: chemical and inactivation kinetics. Water Res. 1999, 33 (11), 2633-41. Nerenberg, R.; Rittmann, B. E., Soucie, W. J. Ozone/biofiltration for removing MIB and geosmin. J Am Water Works Assoc. 2000, 92 (12), 85. Saroj, D. P.; Kumar, A.; Bose, P.; Tare, V., Dhopavkar, Y. Mineralization of some natural refractory organic compounds by biodegradation and ozonation. Water Res. 2005, 39 (9), 192133. Zhang, Y. Pagilla, K. Gas-Phase Ozone Oxidation of Hydrogen Sulfide for Odor Treatment in Water Reclamation Plants. Ozone Sci. Eng. 2013, 35 (5), 390-8. Sung, B.; Chu, K.; Yun, S.; Ahn, J.; Lee, J.; Yoo, S.; Lee, J., Ko, K. Removal of iron and manganese ions from abandoned neutral or alkaline mine drainage via ozone oxidation and micro-sand filtration: a pilot-scale operation. Desalin Water Treat. 2015, 53 (9), 2354-62. Jekel, M. R. Effects and mechanisms involved in preoxidation and particle separation processes. Water Sci Technol. 1998, 37 (10), 1-7. Blackbeard, J.; Lloyd, J.; Magyar, M.; Mieog, J.; Linden, K. G., Lester, Y. Demonstrating organic contaminant removal in an ozone-based water reuse process at full scale. Environ Sci Wat Res. 2016, 2 (1), 213-22. Gerrity, D.; Gamage, S.; Holady, J. C.; Mawhinney, D. B.; Quiñones, O.; Trenholm, R. A., Snyder, S. A. Pilot-scale evaluation of ozone and biological activated carbon for trace organic contaminant mitigation and disinfection. Water Res. 2011, 45 (5), 2155-65. Hollender, J.; Zimmermann, S. G.; Koepke, S.; Krauss, M.; McArdell, C. S.; Ort, C.; Singer, H.; von Gunten, U., Siegrist, H. Elimination of organic micropollutants in a municipal wastewater treatment plant upgraded with a full-scale post-ozonation followed by sand filtration. Environ. Sci. Technol. 2009, 43 (20), 7862-9. Huber, M. M.; GÖbel, A.; Joss, A.; Hermann, N.; LÖffler, D.; McArdell, C. S.; Ried, A.; Siegrist, H.; Ternes, T. A., von Gunten, U. Oxidation of pharmaceuticals during ozonation of municipal wastewater effluents: a pilot study. Environ. Sci. Technol. 2005, 39 (11), 4290-9. Reungoat, J.; Escher, B.; Macova, M.; Argaud, F.; Gernjak, W., Keller, J. Ozonation and biological activated carbon filtration of wastewater treatment plant effluents. Water Res. 2012, 46 (3), 863-72. Rosal, R.; Rodríguez, A.; Perdigón-Melón, J. A.; Petre, A.; García-Calvo, E.; Gómez, M. J.; Agüera, A., Fernández-Alba, A. R. Occurrence of emerging pollutants in urban wastewater and their removal through biological treatment followed by ozonation. Water Res. 2010, 44 (2), 57888. Eggen, R. I.; Hollender, J.; Joss, A.; Schärer, M., Stamm, C. Reducing the discharge of micropollutants in the aquatic environment: the benefits of upgrading wastewater treatment plants. Environ. Sci. Technol. 2014, 48 (14), 7683-9. J, B.; G, U.; J, C., T, B., Water Research Foundation North American Biofiltration Knowledge Base Project #4459. 2016. Schimmoller, L.; Bott, C.; Mitchell, J.; Bernas, J.; Henifin, T.; Snyder, E., Holloway, D. Comparing Advanced Treatment Approaches for a Large-Scale Potable Reuse Project in Southeastern Virginia. Proc Water Env Fed. 2016, 2016 (12), 4792-806. Gerrity, D. Snyder, S. Review of ozone for water reuse applications: toxicity, regulations, and trace organic contaminant oxidation. Ozone Sci. Eng. 2011, 33 (4), 253-66.
Page 23 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545
17.
18.
19. 20. 21.
22.
23. 24.
25. 26.
27. 28. 29. 30. 31. 32. 33. 34.
35. 36. 37.
Page 24 of 33
Ramseier, M. K.; von Gunten, U.; Freihofer, P., Hammes, F. Kinetics of membrane damage to high (HNA) and low (LNA) nucleic acid bacterial clusters in drinking water by ozone, chlorine, chlorine dioxide, monochloramine, ferrate (VI), and permanganate. Water Res. 2011, 45 (3), 1490-500. Hammes, F.; Berney, M.; Wang, Y. Y.; Vital, M.; Koster, O., Egli, T. Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes. Water Res. 2008, 42 (1-2), 269-77. Lee, J. Deininger, R. A. Survival of bacteria after ozonation. Ozone Sci. Eng. 2000, 22 (1), 65-75. Vital, M.; Hammes, F., Egli, T. Competition of Escherichia coli O157 with a drinking water bacterial community at low nutrient concentrations. Water Res. 2012, 46 (19), 6279-90. Czekalski, N.; Imminger, S.; Salhi, E.; Veljkovic, M.; Kleffel, K.; Drissner, D.; Hammes, F.; Bürgmann, H., von Gunten, U. Inactivation of Antibiotic Resistant Bacteria and Resistance Genes by Ozone: From Laboratory Experiments to Full-Scale Wastewater Treatment. Environ. Sci. Technol. 2016, 50 (21), 11862-71. Taylor, R. H.; Falkinham, J. O.; Norton, C. D., LeChevallier, M. W. Chlorine, chloramine, chlorine dioxide, and ozone susceptibility of Mycobacterium avium. Appl. Environ. Microbiol. 2000, 66 (4), 1702-5. Berry, D.; Xi, C., Raskin, L. Effect of Growth Conditions on Inactivation of Escherichia coli with Monochloramine. Environ. Sci. Technol. 2009, 43 (3), 884-9. Steed, K. A. Falkinham, J. O. Effect of growth in biofilms on chlorine susceptibility of Mycobacterium avium and Mycobacterium intracellulare. Appl. Environ. Microbiol. 2006, 72 (6), 4007-11. Du, Z.; Nandakumar, R.; Nickerson, K. W., Li, X. Proteomic adaptations to starvation prepare Escherichia coli for disinfection tolerance. Water Res. 2015, 69, 110-9. Lezcano, I.; Pérez Rey, R.; Baluja, C., Sánchez, E. Ozone Inactivation of Pseudomonas aeruginosa, Escherichia coli, Shigella sonnei and Salmonella typhimurium in Water. Ozone Sci. Eng. 1999, 21 (3), 293. Broadwater, W. T.; Hoehn, R., King, P. Sensitivity of three selected bacterial species to ozone. Appl. Microbiol. 1973, 26 (3), 391-3. Kim, D.; Kim, D.-I.; Kim, J.-H., Stoesser, T. Large eddy simulation of flow and tracer transport in multichamber ozone contactors. J. Environ. Eng. 2009, 136 (1), 22-31. Vital, M.; Stucki, D.; Egli, T., Hammes, F. Evaluating the Growth Potential of Pathogenic Bacteria in Water. Appl. Environ. Microbiol. 2010, 76 (19), 6477-84. Pinto, A. J.; Xi, C. W., Raskin, L. Bacterial Community Structure in the Drinking Water Microbiome Is Governed by Filtration Processes. Environ. Sci. Technol. 2012, 46 (16), 8851-9. Langlais, B.; Reckhow, D. A., Brink, D. R., Ozone in water treatment: application and engineering. 1991: American Water Works Research Foundation, CRC press. Hunt, N. K. Mariñas, B. J. Kinetics of Escherichia coli inactivation with ozone. Water Res. 1997, 31 (6), 1355-62. APHA AWWA. WEF, 2005. Standard Methods for the Examination of Water and Wastewater. 2005, 21, 258-9. Barbesti, S.; Citterio, S.; Labra, M.; Baroni, M. D.; Neri, M. G., Sgorbati, S. Two and three‐ color fluorescence flow cytometric analysis of immunoidentified viable bacteria. Cytometry. 2000, 40 (3), 214-8. Van Nevel, S.; Koetzsch, S.; Weilenmann, H.-U.; Boon, N., Hammes, F. Routine bacterial analysis with automated flow cytometry. J. Microbiol. Methods. 2013, 94 (2), 73-6. Zhang, J.; Tejada-Martínez, A., Zhang, Q. Hydraulic efficiency in RANS of the flow in multichambered contactors. J. Hydraul. Eng. 2013, 139 (11), 1150-7. Hill, V. R.; Narayanan, J.; Gallen, R. R.; Ferdinand, K. L.; Cromeans, T., Vinjé, J. Development of a Nucleic Acid Extraction Procedure for Simultaneous Recovery of DNA and RNA from Diverse Microbes in Water. Pathogens. 2015, 4 (2), 335-54. Page 24 of 27 ACS Paragon Plus Environment
Page 25 of 33
546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595
Environmental Science & Technology
38.
39.
40.
41.
42. 43.
44.
45. 46. 47.
48.
49.
50. 51.
52.
53. 54. 55.
Haig, S.-J.; Kotlarz, N.; LiPuma, J. J., Raskin, L. A high-throughput approach for identification of nontuberculous mycobacteria in drinking water reveals relationship between water age and Mycobacterium avium. Submitted. mBio. Kozich, J. J.; Westcott, S. L.; Baxter, N. T.; Highlander, S. K., Schloss, P. D. Development of a dual-index sequencing strategy and curation pipeline for analyzing amplicon sequence data on the MiSeq Illumina sequencing platform. Appl. Environ. Microbiol. 2013, 79 (17), 5112-20. Caporaso, J. G.; Lauber, C. L.; Walters, W. A.; Berg-Lyons, D.; Lozupone, C. A.; Turnbaugh, P. J.; Fierer, N., Knight, R. Global patterns of 16S rRNA diversity at a depth of millions of sequences per sample. Proc. Natl. Acad. Sci. 2011, 108 (Supplement 1), 4516-22. Schloss, P. D.; Westcott, S. L.; Ryabin, T.; Hall, J. R.; Hartmann, M.; Hollister, E. B.; Lesniewski, R. A.; Oakley, B. B.; Parks, D. H.; Robinson, C. J.; Sahl, J. W.; Stres, B.; Thallinger, G. G.; Van Horn, D. J., Weber, C. F. Introducing mothur: Open-Source, Platform-Independent, Community-Supported Software for Describing and Comparing Microbial Communities. Appl. Environ. Microbiol. 2009, 75 (23), 7537-41. Westcott, S. L. Schloss, P. D. OptiClust, an Improved Method for Assigning Amplicon-Based Sequence Data to Operational Taxonomic Units. mSphere. 2017, 2 (2), e00073-17. Wang, Q.; Garrity, G. M.; Tiedje, J. M., Cole, J. R. Naive Bayesian classifier for rapid assignment of rRNA sequences into the new bacterial taxonomy. Appl. Environ. Microbiol. 2007, 73 (16), 5261-7. Cole, J. R.; Wang, Q.; Cardenas, E.; Fish, J.; Chai, B.; Farris, R. J.; Kulam-Syed-Mohideen, A.; McGarrell, D. M.; Marsh, T., Garrity, G. M. The Ribosomal Database Project: improved alignments and new tools for rRNA analysis. Nucleic Acids Res. 2009, 37 (suppl 1), D141-D5. Van der Kooij, D. Hijnen, W. Substrate utilization by an oxalate-consuming Spirillum species in relation to its growth in ozonated water. Appl. Environ. Microbiol. 1984, 47 (3), 551-9. Alarcon-Ruiz, L.; Platret, G.; Massieu, E., Ehrlacher, A. The use of thermal analysis in assessing the effect of temperature on a cement paste. Cem. Concr. Res. 2005, 35 (3), 609-13. Ben‐Dor, E. Banin, A. Determination of organic matter content in arid‐zone soils using a simple “loss‐on‐ignition” method. Communications in Soil Science & Plant Analysis. 1989, 20 (15-16), 1675-95. Frost, R.; Hales, M., Martens, W. Thermogravimetric analysis of selected group (II) carbonateminerals—Implication for the geosequestration of greenhouse gases. Journal of Thermal Analysis and Calorimetry. 2008, 95 (3), 999-1005. Vital, M.; Dignum, M.; Magic-Knezev, A.; Ross, P.; Rietveld, L., Hammes, F. Flow cytometry and adenosine tri-phosphate analysis: alternative possibilities to evaluate major bacteriological changes in drinking water treatment and distribution systems. Water Res. 2012, 46 (15), 4665-76. Norton, C. D. LeChevallier, M. W. A pilot study of bacteriological population changes through potable water treatment and distribution. Appl. Environ. Microbiol. 2000, 66 (1), 268-76. Van Nevel, S.; Koetzsch, S.; Proctor, C. R.; Besmer, M. D.; Prest, E. I.; Vrouwenvelder, J. S.; Knezev, A.; Boon, N., Hammes, F. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring. Water Res. 2017, 113, 191-206. Berney, M.; Vital, M.; Hülshoff, I.; Weilenmann, H.-U.; Egli, T., Hammes, F. Rapid, cultivationindependent assessment of microbial viability in drinking water. Water Res. 2008, 42 (14), 40108. Ward, D. M.; Weller, R., Bateson, M. M. 16S rRNA sequences reveal numerous uncultured microorganisms in a natural community. Nature. 1990, 345 (6270), 63-5. Eagon, R. G. Pseudomonas natriegens, a marine bacterium with a generation time of less than 10 minutes. J. Bacteriol. 1962, 83 (4), 736-7. Pade, C. Guimaraes, M. The CO2 uptake of concrete in a 100 year perspective. Cem. Concr. Res. 2007, 37 (9), 1348-56.
Page 25 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645
56. 57. 58. 59.
60. 61.
62.
63. 64. 65. 66.
67.
68. 69.
70.
71. 72. 73.
74.
75.
Page 26 of 33
Rittmann, B., Detachment from biofilms. In: Characklis WG, Wilderer PA, editors. Structure and function of biofilms. 1989, New York: John Wiley & Sons. p. 49-58. Bester, E.; Wolfaardt, G. M.; Aznaveh, N. B., Greener, J. Biofilms’ role in planktonic cell proliferation. Int. J. Mol. Sci. 2013, 14 (11), 21965-82. Picioreanu, C.; Van Loosdrecht, M. C., Heijnen, J. J. Two-dimensional model of biofilm detachment caused by internal stress from liquid flow. Biotechnol. Bioeng. 2001, 72 (2), 205-18. Bester, E.; Kroukamp, O.; Wolfaardt, G. M.; Boonzaaier, L., Liss, S. N. Metabolic differentiation in biofilms as indicated by carbon dioxide production rates. Appl. Environ. Microbiol. 2010, 76 (4), 1189-97. Hoigne, J. Bader, H. Ozonation of water: selectivity and rate of oxidation of solutes. Ozone Sci. Eng. 1979, 1 (1), 73-85. Alexander, J.; Knopp, G.; Dötsch, A.; Wieland, A., Schwartz, T. Ozone treatment of conditioned wastewater selects antibiotic resistance genes, opportunistic bacteria, and induce strong population shifts. Sci. Total Environ. 2016, 559, 103-12. Chiao, T.; Clancy, T. M.; Pinto, A. J.; Xi, C., Raskin, L. Differential Resistance of Drinking Water Bacterial Populations to Monochloramine Disinfection. Environ. Sci. Technol. 2014, 48 (7), 4038-47. Botzenhart, K.; Tarcson, G., Ostruschka, M. Inactivation of bacteria and coliphages by ozone and chlorine dioxide in a continuous flow reactor. Water Sci Technol. 1993, 27 (3-4), 363-70. Wayne, L. G. Gross, W. M. Base composition of deoxyribonucleic acid isolated from mycobacteria. J. Bacteriol. 1968, 96 (6), 1915-9. Mah, T.-F. C. O'Toole, G. A. Mechanisms of biofilm resistance to antimicrobial agents. Trends Microbiol. 2001, 9 (1), 34-9. Berney, M.; Weilenmann, H.-U.; Ihssen, J.; Bassin, C., Egli, T. Specific growth rate determines the sensitivity of Escherichia coli to thermal, UVA, and solar disinfection. Appl. Environ. Microbiol. 2006, 72 (4), 2586-93. Liu, R.; Zhu, J.; Yu, Z.; Joshi, D.; Zhang, H.; Lin, W., Yang, M. Molecular analysis of long-term biofilm formation on PVC and cast iron surfaces in drinking water distribution system. J. Environ. Sci. (China). 2014, 26 (4), 865-74. Wang, H.; Hu, C.; Hu, X.; Yang, M., Qu, J. Effects of disinfectant and biofilm on the corrosion of cast iron pipes in a reclaimed water distribution system. Water Res. 2012, 46 (4), 1070-8. Feazel, L. M.; Baumgartner, L. K.; Peterson, K. L.; Frank, D. N.; Harris, J. K., Pace, N. R. Opportunistic pathogens enriched in showerhead biofilms. Proc. Natl. Acad. Sci. U. S. A. 2009, 106 (38), 16393-8. Becerra-Castro, C.; Macedo, G.; Silva, A. M.; Manaia, C. M., Nunes, O. C. Proteobacteria become predominant during regrowth after water disinfection. Sci. Total Environ. 2016, 573, 313-23. Müller, S. Nebe-von-Caron, G. Functional single-cell analyses: flow cytometry and cell sorting of microbial populations and communities. FEMS Microbiol. Rev. 2010, 34 (4), 554-87. von Gunten, U.; Bruchet, A., Costentin, E. Bromate formation in advanced oxidation processes. J Am Water Works Assoc. 1996, 88 (6), 53. Gerrity, D.; Pisarenko, A. N.; Marti, E.; Trenholm, R. A.; Gerringer, F.; Reungoat, J., Dickenson, E. Nitrosamines in pilot-scale and full-scale wastewater treatment plants with ozonation. Water Res. 2015, 72, 251-61. Liu, S.; Gunawan, C.; Barraud, N.; Rice, S. A.; Harry, E. J., Amal, R. Understanding, monitoring, and controlling biofilm growth in drinking water distribution systems. Environ. Sci. Technol. 2016, 50 (17), 8954-76. Lautenschlager, K.; Hwang, C.; Liu, W.-T.; Boon, N.; Köster, O.; Vrouwenvelder, H.; Egli, T., Hammes, F. A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks. Water Res. 2013, 47 (9), 3015-25.
Page 26 of 27 ACS Paragon Plus Environment
Page 27 of 33
646 647
Environmental Science & Technology
76.
Lin, W.; Yu, Z.; Zhang, H., Thompson, I. P. Diversity and dynamics of microbial communities at each step of treatment plant for potable water generation. Water Res. 2014, 52, 218-30.
Page 27 of 27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 28 of 33
Cumulative 75% + 1.5*IQR 25-75% 25% - 1.5*IQR Median Outliers
5 (Outlet basin)
Inlet Inlet basin
1
2
3
4
5
6
7
Outlet basin
Outlet
Ozone gas Sample Line
Figure 1. Box and whisker plot for ozone CT (average concentration × contact time) for each chamber across contactors sampled on eight days. Cumulative ozone exposure is represented by orange triangles (mean values measured on eight days; error bars represent standard deviations). Water from an inlet basin flows through seven chambers and then into an outlet basin. Ozone gas is added into chambers 2 and 3. The cumulative residence time in a contactor is approximately 10 min. The width of chamber 3 is larger than the widths of the other chambers to provide additional disinfectant contact time.
Page 1 of 5 ACS Paragon Plus Environment
Page 29 of 33
Environmental Science & Technology
75% + 1.5*IQR
a
25-75% 25% - 1.5*IQR Median Outliers
(200 - 3,850 CFU/mL)
b
(1,200 - 3,750 cells/mL)
Figure 2. Box and whisker plots representing viable cell concentrations of lime-softened water (sample line 1) and in different chambers during ozone exposure monitored by (a) HPC on six days, and (b) flow cytometry on four days. HPC data are reported as the average of duplicate dilutions plated in triplicate (n = 6 counts per sample except for chamber 1 and chamber 4 samples collected on May 13, 2016, which had only 5 and 4 counts, respectively). The numbers in parentheses indicate the range of cell concentrations at sample line 5.
Page 2 of 5 ACS Paragon Plus Environment
Environmental Science & Technology
a
Page 30 of 33
b Water in chamber 2
Water in chamber 2
Water in chamber 3
Water in chamber 3
Chamber 2 water in control
Chamber 2 water in control
Time after shutdown (h)
Time after shutdown (h)
Figure 3. Average concentrations of viable cells monitored by (a) HPC and (b) flow cytometry before, 2 h after, and 9.5 h after contactor shutdown in water sampled from chambers 2 and 3, and water sampled from chamber 2 stored separately as an experimental control. Error bars represent standard deviation of duplicate dilutions plated in at least triplicate (except the control at 9.45 h in which duplicate plates were counted) or range of duplicate flow cytometry measurements.
Page 3 of 5 ACS Paragon Plus Environment
Page 31 of 33
Environmental Science & Technology
Sludge
OTU0010 OTU0005 Diffuser OTU0004 2R 2R 3L
3R 3R
OTU0016
4R 4R 5R OTU0013 OTU0001 OTU00012 OTU00014
Figure 4. Non-metric multidimensional scaling (NMDS) plot of ϴyc distance ordinations showing differences in community structure for total bacteria in biofilm and sludge samples. Biofilm samples were collected from chambers 2-5 on right or left baffle walls (indicated by R or L). There was significant (p = 0.017) separation between bacterial communities in biofilm on baffle walls located before (green points) and after (blue points) a dead zone. Of the top 20 most abundant OTUs across the samples, the OTUs with relative abundances that increased or decreased significantly (p < 0.01) along NMDS axis 1 are shown in red. OTU00010, OTU0005, OTU0004, OTU00016, OTU00013, OTU0001, OTU0012, and OTU0014 were classified as Brevundimonas, Methylophilus, Limnobacter, Sphingomonas, Sphingopyxis, Gp4, Hyphomicrobiaceae, and Sphingomonadaceae, respectively.
Page 4 of 5 ACS Paragon Plus Environment
Environmental Science & Technology
Page 32 of 33
` Legionella spp. Mycobacterium spp.
2R
2R
1
3L Diffuser Sludge
2
3
3R
4
3R
5
4R
6
4R
5R
7
Inlet Inlet basin
2R
3L
3R
4R
5R
Diffuser
Outlet basin
Outlet
Sludge Sample Line
Figure 5. Relative abundance of 20 Legionella OTUs (red) and 4 Mycobacterium OTUs (blue) in biofilm samples collected from chambers 2-5 on right or left baffle walls (indicated by R or L), a diffuser (Diffuser), and sludge (Sludge) from one contactor. Chamber numbers 1-7 are shown at the top of the contactor schematic.
Page 5 of 5 ACS Paragon Plus Environment