The new LDC/Milton Roy spectroMonitor*D variable wavelength detector. On the outside, the newest variable wavelength detector from L D C / M i l t o n Roy looks very much like its predecessors. But on the inside, where it counts, the spectroMonitor®D variable wavelength detector sets new industry standards for quality and performance. LOWEST NOISE A N D D R I F T The new spectroMonitor D variable wavelength de­ tector delivers the lowest noise (2 χ 10" 5 A U peak to peak) and d r i f t (1 χ 10" 4 AU/hr.) specifications avail­ able today. Highly efficient dual beam optical system and state-of-the-art electronics make these specifi­ cations possible.

HIGHEST EFFICIENCY A N D S E N S I T I V I T Y STANDARD Our new max N ™ series high efficiency , high pressure (1000 psi) fluid cell is a standard feature in the spectroMonitor D. The competition makes you pay extra for high efficiency. In addition, the max Ν series f l u i d cell has optimized f l o w dynamics and a true 10mm pathlength to maximize sensitivity ac­ cording to Beer's Law. Others have tried t o beat our noise and d r i f t specifications by cutting cell pathlength, but in the process, they decreased sensitivity. With the spectroMonitor D you get it all - low noise, low drift and high sensitivity. U V / V I S MEASUREMENTS The spectroMonitor D also features absorbance measurements over the entire U V / V I S spectrum (190700nm) without a lamp change. One 35-Watt deute­ rium lamp is all you need to buy or replace.

^ - &

j£^-

*

2.64

D I G I T A L DIAGNOSTICS New LED diagnostic circuitry, introduced in the spectroMonitor D, provides you w i t h a switch select­ able digital display of absorbance units, reference and sample energy in m V , lamp current in m A , and zero offset.

3.34

0.001 A U F S

0.1 A U F S

TIME

PICO GRAM

NAME

TIME

PICO GRAM

2.64 3.34 4.15

31 11 26

BIPHEMYL ANTHRACENE PYRENE

2.64 3.34 4.14

3110 1138 2673

SPECTROMONITOR D WAVELENGTH 241 N i l RISE TIME 1.0 SEC RANGE 0.001 A.U.F.S.

Chromatogram spectroMonitor

illustrating D.

SPHERISORB ODS COLUMN 5 DM 4.6 * 260 MM ELUENT: 80% CH3CN 205Î.H2C 20 UL INJECTION

detection

limits

with

the

A T R A D I T I O N OF Q U A L I T Y A N D PERFORMANCE L D C / M i l t o n Roy pioneered HPLC technology over a decade ago. We have put all of our techno­ logical experience and knowledge into making an instrument that is worth much more than its $5890.00 price. Let us show how the spectroMonitor D can w o r k for y o u . For further information call our Technical Representatives at 8 0 0 - 3 2 7 - 6 1 8 2 .

U.S. H E A D Q U A R T E R S , P.O. Box 10235, Riviera Beach, F L 33404. Toll-free: 800-327-6182, I n Florida: (3051 844-5241 International Telex: 4 4 1 0 9 8 , Domestic Telex: 513479 S U N N Y V A L E O P E R A T I O N . 560 Oakmead Parkway, Sunnyvale, CA 9 4 0 8 6 Toll-free: 800-538-1595, In California: (4081 736-0300 U N I T E D K I N G D O M , L D C U K , M i l t o n Roy House, 52 High Street, Stone. Staffordshire ST15 8 A R England Phone: 785-81-3542 Telex: 36623 WEST G E R M A N Y , M i l t o n Roy (Deutschlend) GMBH Jahnstrasse 22-24 6 4 6 7 Hasselroth 2 , West Germany Phone: 6055-2031 (3366) Telex: 41843S7 J A P A N , M i l t o n R o y K.K.,Tekanawa Dai-lchi Building 2 1 - 4 1 , Takanawa 2-Chrome, M i n a t o - K u , T o k y o 1 0 8 . Japan Phone: {03} 473-3181 Telex: 242-4296

CIRCLE 131 ON READER SERVICE CARD

ANALYTICAL CHEMISTRY, VOL. 55, NO. 6, MAY 1983 · 677 A