Molecular Analysis for Screening Human Bacterial ... - ACS Publications

Sep 2, 2014 - wastewater treatment plant in Abu Dhabi, UAE. PCR-DGGE with universal 16S rRNA gene primers has been widely used to study the structural...
0 downloads 0 Views 1MB Size
Article pubs.acs.org/est

Molecular Analysis for Screening Human Bacterial Pathogens in Municipal Wastewater Treatment and Reuse Rajkumari Kumaraswamy,† Yamrot M. Amha,† Muhammad Z. Anwar,‡ Andreas Henschel,‡ Jorge Rodríguez,† and Farrukh Ahmad*,† †

Institute Center for Water and Environment (iWATER), Masdar Institute of Science and Technology, P.O. Box 54224, Abu Dhabi, UAE ‡ Institute Center for Smart and Sustainable Systems (iSmart), Masdar Institute of Science and Technology, P.O. Box 54224, Abu Dhabi, UAE S Supporting Information *

ABSTRACT: Effective and sensitive monitoring of human pathogenic bacteria in municipal wastewater treatment is important not only for managing public health risk related to treated wastewater reuse, but also for ensuring proper functioning of the treatment plant. In this study, three different 16S rRNA gene molecular analysis methodologies were employed to screen bacterial pathogens in samples collected at three different stages of an activated sludge plant. Overall bacterial diversity was analyzed using next generation sequencing (NGS) on the Illumina MiSeq platform, as well as PCR-DGGE followed by band sequencing. In addition, a microdiversity analysis was conducted using PCR-DGGE, targeting Escherichia coli. Bioinformatics analysis was performed using QIIME protocol by clustering sequences against the Human Pathogenic Bacteria Database. NGS data were also clustered against the Greengenes database for a genera-level diversity analysis. NGS proved to be the most effective approach screening the sequences of 21 potential human bacterial pathogens, while the E. coli microdiversity analysis yielded one (O157:H7 str. EDL933) out of the two E. coli strains picked up by NGS. Overall diversity using PCR-DGGE did not yield any pathogenic sequence matches even though a number of sequences matched the NGS results. Overall, sequences of Gramnegative pathogens decreased in relative abundance along the treatment train while those of Gram-positive pathogens increased.



INTRODUCTION The demand for water around the globe for agriculture and other forms of irrigation is exponentially growing as a result of population growth and urbanization.1,2 The use of treated wastewater to augment freshwater supply is often projected as a solution to overcome water scarcity.3,4 Consequently, various countries around the world are adopting treated wastewater reuse practices for irrigation, with the highest volumes reported in Mexico and Egypt, with approximately 4 million and 2 million m3/day, respectively.5 However, treated municipal wastewater carries the risk of contamination from pathogenic microorganisms owing to incomplete disinfection of recalcitrant organisms. Therefore, treated wastewater requires vigilant monitoring for the presence of pathogens prior to reuse. Developing reliable procedures to screen pathogens is crucial for setting guidelines on restricted and unrestricted treated wastewater reuse.6,7 Traditional culture-based microbiological methods, such as Most Probable Number (MPN) and plating have been widely used for wastewater quality assessment.8,9 However, monitoring pathogens using conventional methods based on indicator organisms has been demonstrated to be inadequate at detecting the presence and levels of pathogens, especially in warmer climates.10,11 Nucleic acid−based molecular methods have overcome the shortcomings of culture-based © 2014 American Chemical Society

methods, by enabling higher sensitivity of pathogen detection, minimizing long-term costs, and by reducing analysis time.12−15 Molecular methods, such as microarrays (a hybridization assay method) and quantitative polymerase chain reaction (qPCR) have been used as targeted approaches in the detection of specific pathogens in wastewater samples enabling a semiquantitative and a direct-quantitative analysis, respectively.16−18 However, these molecular approaches are pathogen-specific and therefore fail to detect the presence of nontargeted pathogens, and overlook overall diversity shifts in microbial community composition.19 The use of 16S rRNA gene analysis to study bacterial diversity and taxonomy has been by far the most common approach in environmental microbiology, and is becoming popular in clinical and food microbiology owing to the availability of standardized techniques and comprehensive databases.20,21 Additionally, it is useful as an exploratory tool for studying poorly characterized mixed-culture samples. In this study, two different 16S rRNA gene analysis methodologies, Received: Revised: Accepted: Published: 11610

May 28, 2014 August 27, 2014 September 2, 2014 September 2, 2014 dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

Figure 1. Flow map of the methodology and data analysis used for microbial macro-diversity study of all bacteria and microdiversity study of Escherichia coli. The approach used for nontargeted pathogen analysis is indicated in orange boxes, whereas the targeted pathogenic organism analysis is indicated with blue boxes.

note that apart from being considered as an indicator microorganism, some of its strains such as E. coli O157:H7, are pathogens causing serious health effects in human beings. Routinely used culture-based E. coli detection methods are inadequate in differentiating between pathogenic and nonpathogenic strains of E. coli. Thus, some researchers have used real-time nested PCR to quantify pathogenic E. coli O157:H7.34 Nevertheless, the development of 16S rRNA DGGE as a fingerprinting tool in the current study will be helpful in analyzing microdiversity directly from genomic DNA extracted from water samples, bypassing pure culture isolation. Furthermore, subsequent sequencing of DGGE bands (band length of ∼550 bp) can reveal the identity of the strains. This study demonstrates three different approaches (Figure 1) to study the presence and distribution of pathogens in the wastewater treatment plant (WWTP) at three different stages of treatment. The study brings a new perspective to wastewater quality monitoring by demonstrating the efficacy of various molecular approaches for the initial screening and diversity analysis of pathogens at different stages of wastewater treatment.

namely, (i) PCR-denaturing gradient gel electrophoresis (PCRDGGE) and (ii) Illumina NGS, were adopted and compared to study bacterial diversity and to screen human pathogens in samples obtained along the process train of the central wastewater treatment plant in Abu Dhabi, UAE. PCR-DGGE with universal 16S rRNA gene primers has been widely used to study the structural bacterial diversity in wastewater treatment.22 In addition, this method has previously been adopted for rapid detection of pathogens23 and tickinfecting bacteria.24 Owing to the low-cost and relatively less intensive data analysis, PCR-DGGE was recommended as a prescreening method for a more efficient use of advanced molecular biology tools such as next generation sequencing (NGS).25 Illumina sequencing, a high-throughput NGS platform utilizing surface-attached automated dye sequencing, enables the identification and characterization of microbial community members in an ecosystem at a depth of up to millions of sequences per sample.26,27 Therefore, Illumina sequencing with universal 16S rRNA gene primers can possibly be used to screen potential pathogens, which would otherwise go undetected using targeted methods. Although frequently applied in medical research,28,29 only one study to date has adopted Illumina sequencing for pathogen analysis in wastewater samples.30 While few researchers have compared the outcomes of PCR-DGGE and NGS,31,32 to the best of our knowledge, this type of analysis has not been conducted in treated wastewater for quality assessment purposes. As a third and targeted approach, a nested PCR based DGGE methodology was developed to analyze the microdiversity of pathogenic and nonpathogenic Escherichia coli in the wastewater treatment train samples. In routine treated wastewater quality monitoring, screening for indicator organisms such as E. coli has been considered an alternative to screening for individual pathogens, in order to enhance sensitivity by circumventing low pathogenic abundance.33 It is important to



MATERIALS AND METHODS Sample Collection. The wastewater treatment plant under study is the central activated sludge municipal wastewater treatment facility of the city of Abu Dhabi, United Arab Emirates, with a design capacity of 260 000 m3/ day. The plant employs chlorination for disinfection. A total of 18 one-liter grab samples were collected from the treatment train over two different time points, December 2012 and April 2013 (mean monthly ambient temperatures of 21 and 27 °C, respectively). In each sampling event, a total of three grab samples were collected from each of the three different stages (i.e., pretreated [PT], prechlorinated [PT], and postdisinfected [PD] samples, (Figure 2)) of municipal wastewater treatment. An important 11611

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

Figure 2. Sampling locations at three stages of the activated sludge wastewater treatment plant. In the first sampling grab samples were collected in December 2012 (mean ambient temperature 21 °C). The second set of samples collected in April 2013 (mean ambient temperature 27 °C) were composited from three grab samples collected over a 12 h period at each location; the sample collection periods at different points along the treatment train were time-staggered by the hydraulic retention time between them.

product obtained was used as a template for a second amplification with E. coli-specific primers 16E1 F and 16E2 R +16E3 R as per Tsen et al. (1998).37 For the second step of amplification with E. coli-specific primers, 25 μL volumes containing 12 μL Readymix Taq PCR reaction mix with MgCl2 (Sigma-Aldrich), 25 nmol Primer mix, and 2 μL of the PCR products from the first round were used. The reactions were carried out as follows: Initial denaturation (94 °C for 4 min); 35 cycles of denaturation (94 °C for 20 s), annealing (60 °C for 20 s) and extension (72 °C for 45 s); and a final extension (72 °C for 10 min). In order to generate products suitable for DGGE, the forward primer was attached to a GC-rich clamp.36 In samples showing no PCR product after the second step, an additional amplification using the same E. coli primers was performed. This approach was necessary mainly in postdisinfected samples, where the E. coli numbers were very low compared to the other water samples. A pure culture of E. coli (DSMZ 1116) from the German Collection of Microorganisms and Cell Cultures GmbH (DSMZ, Braunschweig, Germany) was used as positive control. In addition to the no-template negative control, genomic DNA of Desulfobacter sp. was used as the second negative control to check for nonspecific amplification of the E. coli specific primers and potential contamination due to pipetting. Denaturing Gradient Gel Electrophoresis (DGGE). DGGE was carried out on PCR amplicons (350 ng of PCR DNA) from the secondary nested amplification (341F-GC/ 907R primer set). The PCR amplicons were separated in a vertically oriented 20 cm × 15 cm × 1 mm polyacrylamide gel (7.5% w/v) with a denaturing gradient between 0% and 80% (no urea and formamide, and 5.6 M urea and 32% v/v formamide, respectively). Full denaturation conditions were defined as 7 M urea and 40% v/v of formamide. The gels were cast as per specifications using the GM-40 gradient maker (C.B.S. Scientific). The gels were immersed in 1×TAE buffer solution and electrophoresis was carried out in at 100 V for 18 h at 60 °C using the DGGE-2001 system (C.B.S. Scientific). The gels were stained with SYBR Green nucleic acid gel stain (Sigma-Aldrich) and the gel images were captured using the Gel Doc XR system (Bio-Rad Laboratories). Prominent bands from the DGGE gel containing the 16S rRNA gene PCR product were excised (SI Figure S1). The DNA was purified from the gel pieces by adding 10 μL of MilliQ water and incubating overnight at 4 °C. The eluted DNA was reamplified with PCR using primer pairs 341F/907R for all bacteria and 16E1F/16E2R +16E3R for E. coli. These DNA samples were sequenced on an ABI 3730xl capillary sequencer using Big Dye terminator chemistry v3.1 (Applied Biosystems). Sequencing was carried out unidirectionally using primers 907R for general bacteria and 16E1F for E. coli by Macrogen (South Korea). Sequences obtained from DGGE gels were checked for

difference in the April 2013 sampling event was that the grab samples were collected over a 12 h duration at each treatment stage, with collection at each stage time-staggered to account for the hydraulic retention time between stages. A portion of the April 2013 grab samples were retained to compare the results between grab and 12 h composite samples. A total of six sampling event- and treatment stage-specific composite samples resulted from the initial 18 grab samples for parallel analyses. The disinfection CT values for the sampling days ranged from 0.024−0.54 g-min/L (residual chlorine values in postdisinfected effluent presented in Supporting Information (SI) Table S1) DNA Extraction. Water samples (1 L) were vacuum filtered through 0.22 μm-pore nitrocellulose membrane filters (Millipore). Total DNA extraction was carried out on the membrane filter using UltraClean Soil DNA Isolation Kits (MO BIO Laboratories, USA). The manufacturer’s protocol for maximum DNA yield was used. Quantification of DNA yield was carried out by loading 1 μL in the NanoDrop 2000 spectrophotometer (Thermo Scientific). PCR Amplification of Bacterial and Escherichia coli 16S rRNA Gene Fragments. The variable V3 and V4 regions of 16S rRNA gene were amplified using PCR in a two-step nested approach. The primary amplification targeted nearly the full length (approximately 1500 bp) of the sequence using the universal bacterial primer set PB36F and PB38R.35 The PCR reactions were carried out using the Bio-Rad iQ5 PCR Thermal Cycler (Bio-Rad) in 25 μL volumes containing 12 μL Readymix Taq PCR reaction mix with MgCl2 (Sigma-Aldrich) and 25 nmol primer mix. The primary amplification was as follows: Initial denaturation (94 °C for 4 min); 30 cycles of denaturation (93 °C for 1 min), annealing (53 °C for 1 min.) and extension (72 °C for 2 min); and a final extension (72 °C for 10 min). For the second step of amplification, a universal bacterial primer set of 341 F-GC and 907 R36 was used. Twenty-five μL reactions with the same component concentrations were carried out as follows: Initial denaturation (95 °C for 4 min); 30 cycles of denaturation (95 °C for 20 s), annealing (53 °C for 20 s) and extension (72 °C for 45 s); and a final extension (72 °C for 10 min). PCR products were checked using agarose gel electrophoresis (1.5% w/v) in TBE buffer at 100 V for 30 min. Gels were stained with SYBR green and images were captured using a Gel Doc XR system (Bio-Rad Laboratories). In every PCR step, a negative no-template control and a positive control (genomic DNA of pure culture strains of E. coli or Desulfobacter sp.) were included. A two-step nested amplification was performed to obtain E. coli-specific 16S rRNA gene fragments suitable for DGGE. In the first step, a nearly complete 16S rRNA gene fragment was amplified using the universal primer pair PB36F and PB38R, following similar conditions as those explained earlier. The 11612

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

Figure 3. Schematic representation of bioinformatics analysis for Illumina sequencing using Quantitative Insights Into Microbial Ecology (QIIME). A total of six water samples from each stage of the treatment plant at two time-points were sequenced. Raw reads were merged with a 90% overlapping length (up to 200 bp). A total of 365 782 reads were taken for downstream bioinformatics analysis using closed reference OTU calling with two databases.

chimeras and trimmed using BioEdit software version 7.0.9 (Ibis Biosciences (http://www.mbio.ncsu.edu/BioEdit/bioedit. html), Carlsbad, CA). The sequences (400−500 bp) determined in this study have been deposited in GenBank (KM403162-KM403198). The DGGE sequences were blasted against the Illumina sequencing results with a threshold similarity of 99% or above. The raw DGGE sequences were clustered with the human pathogenic bacteria 16S rRNA gene database30,38 to identify potential pathogens. Illumina Sequencing and Data Analysis. The 16S rRNA gene libraries for paired-end Illumina sequencing were constructed with the primers targeting V4 region (U515-F and E786-R) of the 16S rRNA gene using a two-step amplicon approach.39 The libraries were multiplexed with other libraries not used in this study and sequenced using the paired-end approach on a MiSeq Illumina sequencing machine at the BioMicro Center (Massachusetts Institute of Technology [MIT], Cambridge). FASTA/Q clipper and FASTA/Q trimmer components of FASTX-toolkit40 were used for adaptor clipping and base trimming, respectively. FASTX-toolkit is distributed under the Affero GPL (AGPL) version 3. Forward and reverse reads that were long enough were turned into FastQ joined reads using the FLASH tool41 for merging the forward and reverse reads, thus capturing the complete V4 region of the 16S rRNA gene. Quantitative Insights Into Microbial Ecology (QIIME)42 was used for the processing and downstream analyses. The closed-reference operational taxonomic unit (OTU) calling was performed against Greengenes as a reference database.43 OTUs were assigned using QIIME implementation of the UCLUST44 algorithm for clustering, with a threshold of 0.97 (97%) similarity. 243 704 hits were identified when compared with Greengenes database sequences, and this gave rise to 5085 distinct OTUs (Figure 3). The unidentified 34% of sequences could be due to chimera, PCR artifacts, sequencing errors or novel sequences not present in Greengenes. Representative OTU sequences were classified taxonomically using the Ribosomal Database Project (RDP)45

classifier against RDP core-set, with a minimum confidence interval of 0.80 (80%). OTU heat maps and sequence counts were generated to summarize the taxonomic communities. In the second approach, the sequences after the initial preprocessing step were clustered against the human pathogenic bacteria 16S rRNA database38 which contains 259 annotated sequences of pathogenic bacteria. The threshold value was set to 0.99 (99%) similarity. For alignment of the OTUs we used the QIIME environment. Multiple sequence alignment was done using PyNast46 and sequences were filtered against RDP core set. The FastTree tool47 was used to generate phylogenetic trees of Gram-negative and Gram-positive pools including identified OTUs, sequence profiles from human pathogenic database, and closely related species from the reference database SILVA (ARB).48 FastTree tool implements neighbor-joining on sequence profiles and uses heuristics to identify candidate joins. Interactive Tree of Life (iTOL),49 visualization server, was used for visualizing the phylogenetic tree and making multivalue bar chart using the data set file constructed that indicates the relative abundance of each identified OTU in all samples.



RESULTS Screening of Microbial Diversity and Pathogens Using PCR-DGGE Analysis of 16S rRNA Genes. Out of six samples studied in duplicate runs, the postdisinfected samples showed the lowest diversity with some of its replicates having maximum of 5−8 bands (SI Figure S1a, lanes labeled PD). The pretreated and prechlorinated samples with higher diversity shared many prominent DNA bands of same melting behavior (SI Figure S1a, lanes labeled PT and PC). Although a significant shift in the population could be observed between the stages and time points, many prominent bands with similar melting behavior were detected between the two time points. However, some bands such as 10B and 9C were only prominent in April 2013 (SI Figure S1a). 11613

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

Figure 4. Phylogenetic analysis of pathogens detected with Illumina sequences obtained in this study, that were found a match with similarity of 99% and above in the analysis against the human pathogenic bacterial 16S rRNA database. Archeoglobus prof undus was used as an outgroup for tree drawing. The scale bar represents an estimated 10% sequence divergence. Escherichia coli 2−Escherichia coli 4 belong to the same strain of pathogenic E. coli O157:H7 str EDL933 and Escherichia 5 belongs to Escherichia coli CFT073.

Figure 5. Pathogens detected and the relative abundance in each sample using Illumina sequencing analysis against human pathogenic database from three stages of the treatment plant and at two time-points. The number in the paranthesis (X-axis) shows the sequence percentage obtained in each sample from the overall pathogenic pool. E. coli_1−E. coli_4 belong to the same strain of pathogenic E. coli O157:H7 str EDL933 and E. coli_5 belongs to Escherichia coli CFT073.

Approximately 60 prominent DGGE bands were excised for sequencing, out of which only 28 generated sequences of very high quality, ranging from 400 bp to 500 bp length. The sequences were initially blasted against the raw sequences obtained from Illumina sequencing of the same samples in order to compare the bacteria targeted by these two methods and their universal 16S rRNA primer pairs. Out of 28 sequences, 25 were found to have a 99% and above match with the sequences obtained with Illumina sequencing (SI Table S2). Additionally, 14 of these 25 sequences were classified up to the Genus-level using Greengenes and RDP as reference databases. The DGGE sequence analysis against the human pathogenic database30 showed that none of the seqeunces matched with 99% or above similarity. The DGGE profiles of individual grab samples from different WWTP stages

collected in the April 2013 event showed same profiling compared to composite samples which were used for final analysis (results not shown). Microdiversity Study of Escherichia coli. The primers 16E1F (forward) and 16E2R + 16E3R (reverse) orginally designed for identifying both pathogenic and nonpathogenic E. coli members in water samples37 were successfully used for DGGE profile analysis in this study by clamping a GC rich region to the forward primer. The DGGE profiling of E. coli 16S rRNA gene products showed maximum of 3−4 bands (SI Figure S1b) indicating a low diversity. Subsequently, the bands were excised and sequenced to determine the identity of the strains, and nine bands generated sequences of very high quality. The sequences were compared against raw sequences generated from Illumina sequencing in the current study and 11614

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

were 100% identical to the sequences of pathogenic E. coli O157:H7 str EDL933 (SI Table S3). The OTU calling procedure matched sequences of pathogenic E. coli O157:H7 str EDL933 also, when compared with the human pathogenic database. Screening and Relative Abundance Estimation of Potential Pathogens Using 16S rRNA Next-Generation Sequencing. Two different appoaches were used for analyzing the Illumina sequences (Figure 3). The raw Illumina sequences were compared against the human pathogenic sequences30 and, in addition, closed-reference OTU calling was conducted against Greengenes general database. 16S rRNA gene sequences matched 21 different pathogenic sequences belonging to various genera and species within the human pathogenic database. The relative abundance of each of these sequences of potential pathogens were calculated for all the three stages of WWTP samples collected in December 2012 and April 2013. Figure 4 displays the phylogenetic affiliations of the pathogens screened while Figure 5 shows their relative abundance in the different water samples. The most dominant sequences of all Gram-negative pathogens screened was Salmonella enterica, followed by strains of E. coli, Vibrio cholerae, and Yersinia pestis. Among the Gram-positive human pathogenic bacterial sequences identified, Mycobacterium tuberculosis, Bacillus anthracis, and Streptococcus agalactiae were present at significantly higher relative abundance in water samples when compared to other Gram-postive pathogens. There was a good indication that the relative abundance of sequences affiliated with Gram-negative enteric pathogens, such as Salmonella enterica and different strains of E. coli, decreased from pretreated to postdisinfected stage. Whereas, the abundance of sequences of Gram-positive pathogens, such as Mycobacterium tuberculosis and Bacillus anthracis, increased in the postdisinfected samples (Figure 5). However, with some Gram-negative pathogens such as Yersinia pestis and Vibrio cholerae there was also an increase in relative abundance along the treatment train, predominantly in December 2012. The closed-reference OTU calling against Greengenes general database showed that 243 704 of the seqeunces clustered to 5085 OTUs (Figure 3), from which 2523 were classified up to the Genus-level (SI Figure S4). The most relatively abundant genera were Mycobacterium, Arcobacter, and Clocibacterium. The results also showed high abundance of sequences belonging to various phyla such as Alpha-, Beta-, and Gamma-proteobacteria.

that all of these 28 sequences matched with greater than 99% similarity to the 16S rRNA sequences of nonpathogenic bacteria obtained through Illumina sequencing (SI Table S2). This result gave strong evidence that DGGE universal primers (341F and 907R) and Illumina primers (U 515F and E 786R) targeted the same kind of bacterial DNA in the PCR. The strategy of using DGGE anlaysis for pathogen detection can be improved dramatically by running a reference lane with DGGE fragments amplified from the pathogenic bacteria of interest along with the PCR products of water samples. This approach will help in excising only the DGGE bands with similar melting profiles to that of the bands of pathogenic bacteria rather than randomly excising dominant bands. It has been demonstrated in detection of fish pathogens, where universal primers were used with PCR-DGGE with a refence lane of known pathogens for a more focused detection.23 Another potential problem with sequencing of excised DGGE bands preamplified with universal primers is that DGGE bands from pathogens in the samples may not necessarily correlate with bands corresponding to pathogenic bacteria. E. coli detection and enumeration in WWTPs is normally performed using culture based methods such as MPN analysis and plating.8 Recently, many researchers have developed molecular methods such as PCR assays targeting toxic genes specific to E. coli such as uidA gene, rfbE gene, shiga toxin genes for detection of E. coli in water samples.50 Few studies have assessed diversity of different strains of E. coli through methodologies such as rep-PCR and pulsed field electrophoresis.51 In the current study, DGGE microdiversity analysis using 16S rRNA gene primers targeting both pathogenic and nonpathogenic E. coli in water samples demonstrated reliable and reproducible results. Apart from showing reproducible band patterns, this methodology was also useful in obtaining sequences of approximately 500 bp matching pathogenic E. coli O157:H7 str EDL933, which was also picked up by Illumina NGS (SI Table S3). The results proved that this methodology can be efficiently used for studying microdiversity of E. coli strains in different kinds of wastewater samples. Furthermore, it is important to note that the sensitivity of the E. coli PCR was significantly improved using a nested PCR approach and therefore it can be used to target E. coli strains of very low abundace in the samples analyzed. Methodologies such as repPCR and pulsed field electrophoresis have already been developed for microdiversity studies of E. coli51,52 and were reported to be more discriminatory between the closely related species than the 16S rRNA based molecular methods.53 However, methods such as rep-PCR need to have pure cultures for the PCR step. Therefore, a precultivation step and isolation of pathogens is required in these techniques, unlike DGGE where genomic DNA extracted from water samples can be directly used for the PCR. In addition, DGGE band sequencing gives phylogenetic affiliation of the bacteria present in the samples analyzed. It is also important to note that in addition to E. coli O157:H7, Illumina sequencing identified an additional E. coli pathogen (E. coli CFT073) which was not identified by DGGE anlysis using E. coli specific primers, possibly due to its very low abundance in the water samples. The main result of this study came via 16S rRNA gene Illumina sequencing of the water samples. NGS methods such as Illumina have several advantages over traditional molecular methods such as 16S rRNA DGGE and clone library analysis. The broader coverage in NGS enables one to identify the microorganisms present in low numbers, which would



DISCUSSION The results from the three 16S rRNA molecular approaches indicated the importance of choosing the right molecular tool for initial screening of human pathogenic bacteria as the approach determines the outcome and the future monitoring strategy. The 16S rRNA gene Illumina NGS with universal bacterial primers (targeting V4 region of the gene) is more effective at screening pathogens than 16S rRNA DGGE (with primers targeting both V3 and V4 regions) combined with the subsequent sequencing of DGGE bands. Around 28 DGGE bands generated 16S rRNA gene sequences of very high quality, however, none of the bands’ sequences were identical to the 16S rRNA gene sequences listed in the human pathogenic database used in this study.38 The main reason for this discrepancy was that not all bands in the DGGE gel (SI Figure S1a) could be sequenced with the approximate success percentage of only 50%. It is, however, important to note 11615

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

wastewater treatment plants such as activated sludge and posttreated storage tanks.57 It is important to note that the relative abundance estimation in Illumina sequencing cannot be the absolute quantification considering all the DNA extraction, PCR, sequencing biases, as well as unequal read depths and variable gene copy numbers among organisms in the samples. Moreover, bioinformatics tools such as QIIME can be used only to calculate relative abundance of the pathogen of interest in the water samples analyzed. Previous researchers58 have indicated the nonreliability of relative abundance by performing quantitative PCR using primers targeting Mycobacterium spp. Other researchers30 have recommended the use of qPCR to confirm and quantify the relative abundance data obtained from next generation sequencing. Therefore, the current screening results, though alarming for the reuse of postdisinfected water, should be further confirmed using qPCR or quantitative reverse transcription-PCR (qRT-PCR) targeting live cells. Although 16S rRNA gene NGS provides valuable indication about the presence of pathogens, even the sequences of >99% similarty to the reference sequences do not conclusively prove their presence. Researchers in clinical microbiology have recommended to use this 16S rRNA approach with the caution of using an approximately 500 bp read length and >99% similarity to the reference pathogenic sequences. They have highlighted that some genera need further validation in addition to 16S rRNA sequences for species classification.20 While the presence of pathogens such as Salmonella enterica and Escherichia coli (with the exception to E.coli 0157: H7, where virulent factors are normally targeted)59−61 have been confidently detected using 16S rRNA methods by previous studies, pathogens such as Vibrio cholerae, Mycobacterium tuberculosis, Bacillus anthracis, Streptococcus spp. and others need a second line of confirmation targeting their virulence factor genes or other functional genes that can be used as markers.20 This is due to the high similarity of 16S rRNA sequences of species within the genera, which makes the approach less discriminatory. However, a detailed phylogenetic analysis was performed for all the 21 pathogens screened using closely related pathogenic sequences from human pathogenic database and ARB database, which indicate the sequences identified could be potential pathogens (SI Figures S2 and S3). It is also important to note that the length of 16S rRNA fragment analyzed in this study is around ∼250 bp, relatively longer than the fragment length covered in other NGS studies,30 and with a higher degree (∼90%) degree of overlap between forward and reverse reads. Therefore, the confidence level here is much higher and could be used as an initial evidence. A detailed literature study on advantages and disadvantages of using 16S rRNA marker gene for the pathogens screened in our current study is provided in the SI (Section II). This study reconfirmed the proposition made by other researchers that molecular methodologies generate more information on the presence of pathogens than the culturebased methods.15,62 Salmonella spp, which were not identified using routine traditional selective enrichment plating at the wastewater treatment plant, were detected in signficant abundance with the Illumina sequencing (Figure 5). The E. coli numbers (through MPN analysis) obtained did not reveal the pathogenicity of the bacteria enumerated (SI Table S1), but the PCR-DGGE and Illumina sequencing screened pathogenic strain E. coli. This was also the case with screening of

otherwise go missing with traditional molecular tools such as PCR-DGGE that give information only on dominant and preferentially amplified sequences in the samples. There are only a few studies that have compared DGGE with next generation sequencing31,32 and, to the best of our knowledge, no such analysis has been conducted in studies to assess the quality and safety of treated wastewater. The raw Illumina sequences were initially compared with the Greengenes database using QIIME clustering alogrithm (SI Figure S4). Later, the sequences were compared with the human pathogenic database developed by Cai and Zhang (2013).30 As shown in Sontakke et al. (2009)54 broad range 16S rRNA amplification has proven to be a useful diagnostic tool in clinical microbiology, especially for well-documented pathogens. The method is limited due to unknown pathogenicity of closely related strains. However, in dealing with these false positives, the findings of our approach are instructive for quantification methods such as qPCR, where suitable marker genes can be selected due to the tight linking of the human pathogenic bacteria database deployed here and the Virulence Factor Database. On the other hand, it is likely that 16S rRNA profiles exhibit the lowest false negative rate as compared to shotgun metagenomics and marker gene identification. Finally, the substantially lower cost per sample makes 16S rRNA sequencing more feasible for successive sampling at high temporal resolution than shot-gun metagenomic analysis, thus enabling the monitoring of intruding and recalcitrant strains in WWTPs. This approach identified 21 different potential pathogens in water samples from different stages of the treatment plant (Figure 4 and SI Figures S2, and S3). Apart from E. coli, intestinal Enterococcus, and Salmonella spp., none of these other pathogens are routinely screened at the WWTP facility. Also, several of the pathogens were not included in the list of common pathogens associated with wastewater reuse in the WHO guidelines.6 The current results clearly indicate that the information obtained through next generation sequencing tools targeting 16S rRNA genes is more inclusive and has the advantage over pathogen targeted assays such as qPCR and microarray, which are more sensitive and specific but also introduce the risk of missing nontargeted pathogens. The results also showed a specific trend in the relative abundance of the pathogenic sequences. The sequences of Gram-positive pathogens such as Mycobacterium tuberculosis and Bacillus anthracis were more abundantly present in the postdisinfected water samples (Figure 5). The same trend was observed for other Gram-positive pathogens’ sequences belonging to the genus Clostrodium spp., Staphylococcu spp., Streptococcus spp. (Figure 5). Conversely, the relative abundance of sequences of Gram-negative pathogens steadily decreased from pretreated to postdisinfected with the exception of Yersinia pestis and Vibrio cholerae. A similar trend of increase in the abundance of Mycobacterium tuberculosis has been previously reported in municipal WWTP facilities.30 The Gram-positive bacteria are reported to have protective cell wall structure and spore forming ability, which allow them to better withstand disinfection processes such as chlorination that was used in this wastewater treatment plant.55,56 This could be one of the primary reasons for high abundance of the sequences of Grampositive pathogens in the postdisinfected water samples of the current study, which needs further detailed investigation. There are also studies which indicated that pathogens can effectively multiply and increase in number in the different stages of 11616

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

(4) Asano, T. Water from(waste) water- the dependable water resource. Water Sci. Technol. 2002, 45 (8), 24. (5) Qadir, M.; Wichelns, D.; Raschid-Sally, L.; McCornick, P. G.; Drechsel, P.; Bahri, A.; Minhas, P. S. The challenges of wastewater irrigation in developing countries. Agric. Water Manage. 2010, 97 (4), 561−568. (6) WHO. Guidelines for Safe Use of Wastewater Excreta & Greywater, Wastewater Use in Agriculture; World Health Organization Geneva: nSwitzerland, 2006. (7) U.S. EPA. Guidelines for Water Reuse, EPA/625/R-04/108, US EPA/625/R-04/108; Environmental Protection Agency, Municipal Support Division Office of Wastewater Management Office of Water, Agency for International Development: Cincinnati, OH, 2004, pp 90−118. (8) Rhee, H. P.; Yoon, C. G.; Son, Y. K.; Jang, J. H. Quantitative risk assessment for reclaimed wastewater irrigation on paddy rice field in Korea. Paddy Water Environ. 2010, 9 (2), 183−191. (9) An, Y.-J.; Yoon, C.; Jung, K.-W.; Ham, J.-H. Estimating the microbial risk of E. coli in reclaimed wastewater irrigation on paddy field. Environ. Monit Assess 2007, 129 (1−3), 53−60. (10) Blumenthal, U. J.; Mara, D. D.; Peasey, A.; Ruiz-Palacios, G.; Stott, R. Guidelines for the microbiological quality of treated wastewater used in agriculture: Recommendations for revising WHO guidelines. Bull. World Health Org. 2000, 78 (9), 1104−1116. (11) Stewart, J. R.; Gast, R. J.; Fujioka, R. S.; Solo-Gabriele, H. M.; Meschke, J. S.; Amaral-Zettler, L. A.; Del Castillo, E.; Polz, M. F.; Collier, T. K.; Strom, M. S. The coastal environment and human health: microbial indicators, pathogens, sentinels and reservoirs. Environ. Health 2008, 7 (Suppl 2), S3. (12) Jofre, J.; Blanch, A. R. Feasibility of methods based on nucleic acid amplification techniques to fulfil the requirements for microbiological analysis of water quality. J. Appl. Microbiol. 2010, 109 (6), 1853−1867. (13) Lemarchand, K.; Berthiaume, F.; Maynard, C.; Harel, J.; Payment, P.; Bayardelle, P.; Masson, L.; Brousseau, R. Optimization of microbial DNA extraction and purification from raw wastewater samples for downstream pathogen detection by microarrays. J. Microbiol. Methods 2005, 63 (2), 115−126. (14) Lemarchand, K.; Masson, L.; Brousseau, R. Molecular biology and DNA microarray technology for microbial quality monitoring of water. Crit. Rev. Microbiol. 2004, 30 (3), 145−172. (15) Gilbride, K.; Lee, D.-Y.; Beaudette, L. Molecular techniques in wastewater: Understanding microbial communities, detecting pathogens, and real-time process control. J. Microbiol. Methods 2006, 66 (1), 1−20. (16) Lee, D.-Y.; Lauder, H.; Cruwys, H.; Falletta, P.; Beaudette, L. A. Development and application of an oligonucleotide microarray and real-time quantitative PCR for detection of wastewater bacterial pathogens. Sci. Tot. Environ. 2008, 398 (1), 203−211. (17) Shannon, K. E.; Lee, D. Y.; Trevors, J. T.; Beaudette, L. A. Application of real-time quantitative PCR for the detection of selected bacterial pathogens during municipal wastewater treatment. Sci. Tot. Environ. 2007, 382 (1), 121−129. (18) Wéry, N.; Lhoutellier, C.; Ducray, F.; Delgenès, J.-P.; Godon, J.J. Behaviour of pathogenic and indicator bacteria during urban wastewater treatment and sludge composting, as revealed by quantitative PCR. Water Res. 2008, 42 (1), 53−62. (19) Aw, T. G.; Rose, J. B. Detection of pathogens in water: from phylochips to qPCR to pyrosequencing. Curr. Opin. Biotechnol. 2012, 23 (3), 422−430. (20) Janda, J. M.; Abbott, S. L. 16S rRNA gene sequencing for bacterial identification in the diagnostic laboratory: Pluses, perils, and pitfalls. J. Clin. Microbiol. 2007, 45 (9), 2761−2764. (21) Woo, P.; Lau, S.; Teng, J.; Tse, H.; Yuen, K. Y. Then and now: use of 16S rDNA gene sequencing for bacterial identification and discovery of novel bacteria in clinical microbiology laboratories. Clin. Microbiol. Infect. 2008, 14 (10), 908−934. (22) Boon, N.; Windt, W.; Verstraete, W.; Top, E. M. Evaluation of nested PCR−DGGE (denaturing gradient gel electrophoresis) with

pathogenic Enteroccoccus faecalis by Illumina sequencing (Figure 5). Finally, water reclamation and reuse is a growing practice around the world. Generally, recycled water is carefully matched based on its quality to a specific nonpotable restricted end-use.63 More recently, water scarcity has prompted several regions in the developed world to consider treated municipal wastewater as a source of direct or indirect augmentation of drinking water supplies. Regions such as Singapore and Southern California have implemented such reuse,64 albeit with further tertiary treatment such as reverse osmosis and advanced oxidation, thereby limiting the risk of human exposure to pathogens. However, much of the developing world still uses treated municipal wastewater directly for landscape irrigation, and in some cases the irrigation of edible crops,5,10 leaving the question of exposure risk from residual pathogens in treated effluent an open one. In conclusion, between the two different methods adopted, 16S rRNA gene Illumina sequencing clearly proved to be a more sensitive methodology compared to 16S rRNA DGGE for initial screening of pathogens. DGGE microdiversity analysis of 16S rRNA fragments of E. coli showed reliable and reproducible results, indicating this procedure can be applied in future E. coli microdiversity studies of water samples from various sources. The higher abundance of sequences of Gram-positive pathogens such as Mycobacterium tuberculosis and Bacillus anthracis, as well as Gram-negative pathogens Yersinia pestis and Vibrio cholerae present in the postdisinfected water samples revealed a significant health risk that needs further evidence such as the presence of toxic (or virulent) genes specific to the pathogens screened, and matagenomics or functional genomics approaches based on next generation sequencing.



ASSOCIATED CONTENT

S Supporting Information *

NGS datasets of this study were deposited in the SRA server (http://www.ncbi.nlm.nih.gov/sra) and accession numbers are listed in SI Table S4. Additional information as noted in the text. This material is available free of charge via the Internet at http://pubs.acs.org.



AUTHOR INFORMATION

Corresponding Author

*Phone: +971 2 810 9114; fax: +971 2 810 9901; e-mail: [email protected]. Notes

The authors declare no competing financial interest.



ACKNOWLEDGMENTS This research was funded under research grants 11WAAA1 and 13XAAA2 from the Masdar Institute of Science and Technology.



REFERENCES

(1) World Water Assessment Programme. Managing Water under Uncertainty and Risk: The United Nations World Water Development Report 4; UNESCO: Paris,́ 2012. (2) Vörösmarty, C. J.; Green, P.; Salisbury, J.; Lammers, R. B. Global water resources: Vulnerability from climate change and population growth. science 2000, 289 (5477), 284. (3) Aina, O. D.; Ahmad, F. Carcinogenic health risk from trihalomethanes during reuse of reclaimed water in coastal cities of the Arabian Gulf. J. Water Reuse Desalin. 2013, 3 (2), 175−184. 11617

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

(40) Gordon, A.; Hannon, G. Fastx-toolkit. FASTQ/A short-reads pre-processing tools (unpublished) 2010. http://hannonlab.cshl.edu/ fastx_toolkit. (41) Magoč, T.; Salzberg, S. L. FLASH: Fast length adjustment of short reads to improve genome assemblies. Bioinformatics 2011, 27 (21), 2957−2963. (42) Caporaso, J. G.; Kuczynski, J.; Stombaugh, J.; Bittinger, K.; Bushman, F. D.; Costello, E. K.; Fierer, N.; Pena, A. G.; Goodrich, J. K.; Gordon, J. I. QIIME allows analysis of high-throughput community sequencing data. Nat. Methods 2010, 7 (5), 335−336. (43) DeSantis, T. Z.; Hugenholtz, P.; Larsen, N.; Rojas, M.; Brodie, E. L.; Keller, K.; Huber, T.; Dalevi, D.; Hu, P.; Andersen, G. L. Greengenes, a chimera-checked 16S rRNA gene database and workbench compatible with ARB. Appl. Environ. Microbiol. 2006, 72 (7), 5069−5072. (44) Edgar, R. C. Search and clustering orders of magnitude faster than BLAST. Bioinformatics 2010, 26 (19), 2460−2461. (45) Maidak, B. L.; Olsen, G. J.; Larsen, N.; Overbeek, R.; McCaughey, M. J.; Woese, C. R. The RDP (ribosomal database project). Nucleic Acids Res. 1997, 25 (1), 109−110. (46) Caporaso, J. G.; Bittinger, K.; Bushman, F. D.; DeSantis, T. Z.; Andersen, G. L.; Knight, R. PyNAST: a flexible tool for aligning sequences to a template alignment. Bioinformatics 2010, 26 (2), 266− 267. (47) Price, M. N.; Dehal, P. S.; Arkin, A. P. FastTree 2− approximately maximum-likelihood trees for large alignments. PloS one 2010, 5 (3), e9490. (48) Pruesse, E.; Quast, C.; Knittel, K.; Fuchs, B. M.; Ludwig, W.; Peplies, J.; Glöckner, F. O. SILVA: a comprehensive online resource for quality checked and aligned ribosomal RNA sequence data compatible with ARB. Nucleic Acids Res. 2007, 35 (21), 7188−7196. (49) Letunic, I.; Bork, P. Interactive Tree Of Life (iTOL): an online tool for phylogenetic tree display and annotation. Bioinformatics 2007, 23 (1), 127−128. (50) Heijnen, L.; Medema, G. Quantitative detection of E. coli, E. coli O157 and other shiga toxin producing E. coli in water samples using a culture method combined with real-time PCR. J. Water Health 2006, 4, 487−498. (51) Dos Anjos Borges, L. G.; Dalla Vechia, V.; Corçaõ , G. Characterisation and genetic diversity via REP-PCR of Escherichia coli isolates from polluted waters in southern Brazil. FEMS Microbiol. Ecol. 2003, 45 (2), 173−180. (52) Casarez, E. A.; Pillai, S. D.; Di Giovanni, G. D. Genotype diversity of Escherichia coli isolates in natural waters determined by PFGE and ERIC-PCR. Water Res. 2007, 41 (16), 3643−3648. (53) Schloter, M.; Lebuhn, M.; Heulin, T.; Hartmann, A. Ecology and evolution of bacterial microdiversity. FEMS Microbiol. Rev. 2000, 24 (5), 647−660. (54) Sontakke, S.; Cadenas, M. B.; Maggi, R. G.; Diniz, P. P. V.; Breitschwerdt, E. B. Use of broad range16S rDNA PCR in clinical microbiology. J. Microbiol. Methods 2009, 76 (3), 217−225. (55) Ridgway, H.; Olson, B. Chlorine resistance patterns of bacteria from two drinking water distribution systems. Appl. Environ. Microbiol. 1982, 44 (4), 972−987. (56) Virto, R.; Manas, P.; Alvarez, I.; Condon, S.; Raso, J. Membrane damage and microbial inactivation by chlorine in the absence and presence of a chlorine-demanding substrate. Appl. Environ. Microbiol. 2005, 71 (9), 5022−5028. (57) Okoh, A. I.; Odjadjare, E. E.; Igbinosa, E. O.; Osode, A. N., Wastewater treatment plants as a source of microbial pathogens in receiving watersheds. Afr. J. Biotechnol. 2007, 6, (25). (58) Radomski, N.; Betelli, L.; Moilleron, R.; Haenn, S.; Moulin, L.; Cambau, E.; Rocher, V.; Gonçalves, A.; Lucas, F. S. Mycobacterium behavior in wastewater treatment plant, a bacterial model distinct from Escherichia coli and enterococci. Environ. Sci. Technol. 2011, 45 (12), 5380−5386. (59) Holland, J.; Louie, L.; Simor, A.; Louie, M. PCR detection of Escherichia coli O157: H7 directly from stools: evaluation of

group-specific 16S rRNA primers for the analysis of bacterial communities from different wastewater treatment plants. FEMS Microbiol. Ecol. 2002, 39 (2), 101−112. (23) Ji, N.; Peng, B.; Wang, G.; Wang, S.; Peng, X. Universal primer PCR with DGGE for rapid detection of bacterial pathogens. J. Microbiol. Methods 2004, 57 (3), 409−413. (24) Schabereiter-Gurtner, C.; Lubitz, W.; Rölleke, S. Application of broad-range 16S rRNA PCR amplification and DGGE fingerprinting for detection of tick-infecting bacteria. J. Microbiol. Methods 2003, 52 (2), 251−260. (25) Hanning, I.; Ricke, S., Prescreening of microbial populations for the assessment of sequencing potential. In High-Throughput Next Generation Sequencing; Kwon, Y. M.; Ricke, S. C., Eds.; Humana Press, 2011; Vol. 733, pp 159−170. (26) Morozova, O.; Marra, M. A. Applications of next-generation sequencing technologies in functional genomics. Genomics 2008, 92 (5), 255−264. (27) Caporaso, J. G.; Lauber, C. L.; Walters, W. A.; Berg-Lyons, D.; Lozupone, C. A.; Turnbaugh, P. J.; Fierer, N.; Knight, R. Global patterns of 16S rRNA diversity at a depth of millions of sequences per sample. Proc. Natl. Acad. Sci. U. S. A. 2011, 108 (Supplement 1), 4516−4522. (28) Nakamura, S.; Maeda, N.; Miron, I. M.; Yoh, M.; Izutsu, K.; Kataoka, C.; Honda, T.; Yasunaga, T.; Nakaya, T.; Kawai, J. Metagenomic diagnosis of bacterial infections. Emerging Infect. Dis. 2008, 14 (11), 1784. (29) Lazarevic, V.; Whiteson, K.; Huse, S.; Hernandez, D.; Farinelli, L.; Østerås, M.; Schrenzel, J.; François, P. Metagenomic study of the oral microbiota by Illumina high-throughput sequencing. J. Microbiol. Methods 2009, 79 (3), 266−271. (30) Cai, L.; Zhang, T. Detecting human bacterial pathogens in wastewater treatment plants by a high-throughput shotgun sequencing technique. Environ. Sci. Technol. 2013, 47 (10), 5433−5441. (31) Cleary, D. F.; Smalla, K.; Mendonça-Hagler, L. C.; Gomes, N. C. Assessment of variation in bacterial composition among microhabitats in a mangrove environment using DGGE fingerprints and barcoded pyrosequencing. PloS one 2012, 7 (1), e29380. (32) Martins, P.; Cleary, D. F.; Pires, A. C.; Rodrigues, A. M.; Quintino, V.; Calado, R.; Gomes, N. C. Molecular analysis of bacterial communities and detection of potential pathogens in a recirculating aquaculture system for Scophthalmus maximus and Solea senegalensis. PloS one 2013, 8 (11), e80847. (33) Campos, C. New perspectives on microbiological water control for wastewater reuse. Desalination 2008, 218 (1−3), 34−42. (34) Tserendorj, A.; Anceno, A. J.; Houpt, E. R.; Icenhour, C. R.; Sethabutr, O.; Mason, C. S.; Shipin, O. V. Molecular techniques in Ecohealth Research Toolkit: Facilitating estimation of aggregate gastroenteritis burden in an irrigated Periurban landscape. EcoHealth 2011, 8 (3), 349−364. (35) Foght, J.; Aislabie, J.; Turner, S.; Brown, C.; Ryburn, J.; Saul, D.; Lawson, W. Culturable bacteria in subglacial sediments and ice from two southern hemisphere glaciers. Microb. Ecol. 2004, 47 (4), 329− 340. (36) Muyzer, G.; De Waal, E. C.; Uitterlinden, A. G. Profiling of complex microbial populations by denaturing gradient gel electrophoresis analysis of polymerase chain reaction-amplified genes coding for 16S rRNA. Appl. Environ. Microbiol. 1993, 59 (3), 695−700. (37) Tsen, H.; Lin, C.; Chi, W. Development and use of 16S rRNA gene targeted PCR primers for the identification of Escherichia coli cells in water. J. Appl. Microbiol. 1998, 85 (3), 554−560. (38) Chen, L.; Yang, J.; Yu, J.; Yao, Z.; Sun, L.; Shen, Y.; Jin, Q. VFDB: a reference database for bacterial virulence factors. Nucleic Acids Res. 2005, 33 (suppl 1), D325−D328. (39) Preheim, S. P.; Perrotta, A. R.; Martin-Platero, A. M.; Gupta, A.; Alm, E. J. Distribution-based clustering: Using ecology to refine the operational taxonomic unit. Appl. Environ. Microbiol. 2013, 79 (21), 6593−6603. 11618

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619

Environmental Science & Technology

Article

commercial extraction methods for purifying fecal DNA. J. Clin. Microbiol. 2000, 38 (11), 4108−4113. (60) El-Hadedy, D.; Abu El-Nour, S. Identification of Staphylococcus aureus and Escherichia coli isolated from Egyptian food by conventional and molecular methods. J. Genet. Eng. Biotechnol. 2012, 10 (1), 129− 135. (61) Jeng, K.; Yang, S.; Won, H.; Gaydos, C. A.; Hsieh, Y.-H.; Kecojevic, A.; Carroll, K. C.; Hardick, J.; Rothman, R. E. Application of a 16S rRNA PCR−high-resolution melt analysis assay for rapid detection of Salmonella bacteremia. J. Clin. Microbiol. 2012, 50 (3), 1122−1124. (62) Toze, S. PCR and the detection of microbial pathogens in water and wastewater. Water Res. 1999, 33 (17), 3545−3556. (63) USEPA. Guidelines for Water Reuse (EPA/625/R-04/108); USEPA: Washington, DC, 2004. (64) Tortajada, C. Water management in Singapore. Water Resour. Dev. 2006, 22 (2), 227−240.

11619

dx.doi.org/10.1021/es502546t | Environ. Sci. Technol. 2014, 48, 11610−11619