New Products: New Products

A digital signal processor handles data on the fly and stores spectra at rates of up to. 100/s. HD Technologies. 413. LC detector. The DDW-10 LC detec...
1 downloads 15 Views 4MB Size
New

Products

Dissolution The MultiDose Plus workstation fully automates pharmaceutical dissolution testing by integrating a side-car workstation that attaches and detaches baskets

INSTRUMENTATION ICP-OES The Optima 3100,3200, and 3300 ICP-OES instruments are based on the Optima 3000. Each system is available in radially viewed, axially viewed, and dually viewed configurations. The upper wavelength limit of each system's UV detector has been extended from 375 nm to 403 nm by enlarging the detector. New subarrays have been added, and previous subarrays have been enlarged to provide an enhanced wavelength set. The 3100 is a single-detector version of the 3000. The 3200, also a single-detector version, uses a modified optical system that determines visible range elements at their optimum wavelength without a second detector. The 3300 is a dual-detector instrument with an optical system that offers simultaneous measurement and UV-vis coverage. Perkin-Elmer • 408 Evaporators The S-Evap (solvent) and N-Evap and Multivap (nitrogen) series of evaporators are benchtop apparatus designed to be used in a hood. The S-Evap has six models that can handle 5-8 samples at a time and can accommodate 125-1000 mL flasks. The SEvap uses either a shallow water bath for round flasks or a deep bath for Kuderna216 A

and retrieves spent capsule sinkers. When used with the VanKel 7(KK) dissolution apparatus, up to eight batches can run unattended. The system preheats and conditions the dissolution media, fills each vessel with the appropriate volume of media, verifies temperature, starts the dissolution test, removes sample aliquots at user-defined time intervals, and empties and cleans each vessel before starting another run. Samples can either be stored for off-line analysis or analyzed on-line with a spectrophotometer. Zymark • 409

Danish flasks. The N-Evap and Multivap has six models that can handle 6-100 samples at a time and can hold test tubes, vials, Erlenmeyers, and centrifuge tubes. Nitrogen or air can be used as the evaporative agent, and a water bath provides heat. Organomation Associates • 410 PAD The model 300 photoacoustic detector can handle macro- or microsamples; operate in diffuse reflectance, absorbance, and transmittance modes; and be used in all FTIR instruments. Microphone nominal sensitivity is 50 mV/Pa, mirror focusing factor is 2:1, the gain range is 2-10,000 in 12 steps, ,nd maximum sample size is 10 mm in diameter x 8 mm in height. The 300 ii sompatible with qualitative and quantitative FTIR applications software. MTEC • 411 Water analysis The APA 6000 process analyzer continuously monitors clean or dirty water and measures alkalinity, ammonia, low-range hardness or nitrate, and combined ammonianitrate. The AquaTrend Interface allows users to remotely control and monitor up to eight APA 6000s. Grab samples can be taken without interrupting water flow. Hach 1 4 1 2

Analytical Chemistry News & Features, March 1, 1998

GC/MS The SprinT benchtop GC/MS acquires fullscan mass spectra at rates of up to 100 kHz. A digital signal processor handles data on theflyand stores spectra at rates of up to 100/s. HD Technologies 413 LC detector The DDW-10 LC detector provides simultaneous absorbance information from two selected wavelengths. The double-beam optical system consists of a continuum energy source (deuterium for UV operation, tungsten for visible operation), beam-shaping optics, dual pathlength flowcell, a broadspectrum beamsplitter, two wavelengthselection filters, and two dual-channel UVvis silicon photodiodes. The detector comes standard for 214-nm and 280-nm operation, and other wavelengths in the UV-vis range can be accommodated. D-Star Instruments 414 Karl Fischer The model 758 Karl Fischer titrator displays a real-time titration curve, stores up to 100 methods, controls up to two additional model 685 titrating burets, and measures sample moisture from 10 ppm to 100% to performing a direct or back titration widi drift compensation. Brinkmann • 415

SPE manifolds The Spe-ed Mate-30 manifold holds up to 30 standard or large-reservoir cartridges and is available in stainless steel or shatterproof acrylic. The Spe-ed Mate-10 holds up to 10 cartridges and is available in stainless steel or acrylic. Glass manifolds are available in 12-, 16-, and 24position sizes. Accessories include collection racks for elution into various containers; luer-fitted needles in different sizes, lengths, and materials; and stopcocks. An inert polymer coating is available for stainless steel manifolds used in corrosive environments. Applied Separations • 416

Olfactroscopy The AromaScan is based on a 32 conductingpolymer sensor array that creates a pattern of the volatiles that can be examined visually or presented to an artificial neural network for characterization. The A32/50S Multisampler, which accommodates up to 50 samples, controls headspace parameters such as equilibration time, temperature, and humidity. The A32/8S LabStation accommodates up to eight single-use disposable 750-mL sample pouches, which can accommodate solid, liquid, gaseous, and powder samples. Samples can be stored in

a temperature-controlled conditioning cabinet (4-35 °C) so that the effect of temperature on the product's aroma can be measured. AromaScan • 418

Raman The Solution 633 dispersive CCD Raman system uses an external 633-nm, 40-W HeNe laser as the excitation source. The Solution 852 uses an internal 852-nm, 150-mW frequency-stabilized diode laser. These systems feature fiber-optic coupling between the laser, the remote mini-epiprobe, and the f/2 imaging spectrograph. D e t e c t i o n Limit • 419

Materials

Depth profiling

The SOC-100 hemispherical directional reflectometer, when coupled to the Nicolet 550/750 FTIR, provides polarized, angular diffusereflectance measurements for incident angles of 10-80° for the entire spectral region covered by the FTIR. The spectral region is nominally 2.025.0 um with standard I-TIR optics and can be extended to 45 urn with cesium-iodide optics. The SOC-100 uses a 2-n imaging heiniellipsoid to diffusely illuminate the sample with a 700 °C blackbody. A moveable overhead mirror captures the energy reflected at an angle and directs a collimated beam into the FTIR. Because the ellipsoid images the diffuse blackbody source onto the sample, energy throughput is maximized and polarized measurements can be taken in the far IR. Surface Optics H 4 1 7

The Phi Adept-200 automated depth-profiling tool uses dynamic SIMS to measure the distribution of dopants for shallow (100 eV)) medium (keV), and deep (MeV) implants. The stage offers fullX, Y travel for access to all points on a 200-mm wafer. Physical Electronics • 420

LC Genesis phenyl and amino columns are base-deactivated reversed-phase columns that provide pH stability and low secondary activity toward basic and acidic analytes. J o n e s Chromatography • 424

GC The CP-Lowox column can be used on-line for the determination of methanol and other oxygenates in hydrocarbon streams to avoid contamination and replacement of catalysts. Chrompack • 4 2 5

CHEMICALS Inorganic standards ICP and AA single-element EnviroConcentrates are manufactured under ISO 9001 and are NIST traceable. The concentration is 10,000 ug/mL in a 10-mL bottle. Ultra Scientific • 426

Chemiluminescence COLUMNS SEC The TSKgel Super SW size-exclusion column is an enhanced version of the TSKgel SWXL, with a particle size of 4 um and an i.d. of 4.6 mm. T o s o H a a s • 421

Diogenes is a superoxide-detecting chemiluminescent enhancer that is nondenaturing to living cells. It is based on luminolmediated chemiluminescence and increases the superoxide-to-photon-release ratio. National D i a g n o s t i c s • 427

LITERATURE

CEC c o l u m n s Nonporous silica capillary columns have a particle size of 1.5 um and come in a range of internal diameters and lengths for CE and LC/MS applications. MICRA • 422

CZE Application note 5965-8938 describes the analysis of cations and anions from electrolessplating baths by capillary zone electrophoresis. Hewlett Packard • 4 2 8

LC/MS/MS Lightning columns come in 3- and 4-um particle sizes; are based on base-deactivated C18, C8, CN, Si, phenyll and amino packing materials; and come in lengths of 10,20,30, 50, and 100 mm, and internal diameters of 2.1,3.0,4.0, and 4.6 mm. J o n e s Chromatography • 423

For more information, please circle the appropriate numbers on one of our Reader Service Cards.