NICOLET INSTRUMENT CORPORATION - Analytical Chemistry (ACS

1 Aug 1971 - NICOLET INSTRUMENT CORPORATION. Anal. Chem. , 1971, 43 (10), pp 32A–32A. DOI: 10.1021/ac60304a723. Publication Date: August ...
3 downloads 0 Views 176KB Size
THIS SIGNAL AVERAGING SYSTEM FILLS TODAY'S NEEDS YET ADAPTS EASILY TO FUTURE REQUIREMENTS. THE BASIC UNIT: Whether your application is in the medical or physical sci­ ences, analytical chemistry, or industrial research, the 1070 Signal Averaging System offers incredible flexibility for adapting to your specific sensitivity improvement require­ ment without compromising future needs. This flexibility results from the wide range of plug-in modules, readout capabilities, and computer compatibility offered by the 1070 System. Memory capacity is 1Κ or 4K by 18 bits.

THE OPTIONS: 19 PLUG-IN MODULES with 12-, 16-, or 18-bit word length generalpurpose com­ puters for fur­ ther processing of a c q u i r e d data.

are presently offered for high resolution A/D con­ version, auto- and crosscorrelation, normalized or exponential averages, s w e e p c o n t r o l , NMR sweep c o n t r o l , pulse height analysis, voltage distribution analysis, sig­ nal delay sweep control, parametric sweep con­ t r o l , one m i c r o s e c o n d s i g n a l d i g i t i z i n g , and time and frequency histo­ gram analysis.

HARD COPY ANALOG READOUT

MAGNETIC TAPE OUTPUT

HARD-WIRE INTERFACE

provides "library" storage of data, transfer of ac­ cumulated data to a large G.P. computer, fast dump­ ing of averager memory (560 m i l l i s e c o n d s for 1,024 words), and addi­ tive or subtractive trans­ fer of 4,096-word blocks of data to or from one another.

o u t p u t s are a v a i l a b l e as well as oscillo­ scope readout of analog dis­ plays and digit­ al n u m e r i c a l display of any memory ad­ dress and its contents.

For a brochure containing 1070 details and specifications write or call collect. A demonstration in your laboratory is available

NICOLET INSTRUMENT CORPORATION In A p r i l 1 9 7 1 , F a b r i - T e k I n s t r u m e n t s , i n c . , changed its name to Nicolet Instrument Corpora­ tion, Personnel, products, service, contractual obligations, and the address and telephone n u m b s i remain the same. We appreciate your past interest in Fabri-Tek instruments, Inc.. and assure you that Nicole! Instrument Corporation stands ready to help solve your signal a v e r a g i n g / d a t a processing problems.

5225 Verona Road, Madison, Wisconsin 53711 Phone: 608/271-3333 TWX: 910-286-2713 (formerly Fabri-Tek Instruments, Inc.)

CIRCLE 122 ON READER SERVICE CARD

32 A ·

ANALYTICAL CHEMISTRY, VOL. 43, NO. 10, AUGUST 1971