Novel off-Gas Treatment Technology To Remove Volatile Organic

Feb 10, 2016 - TEG (with a purity of 99.9%) to a gas ratio of 4:1 by weight, and .... (17) regeneration column, (18) condenser, (19) deep condenser, (...
0 downloads 0 Views 743KB Size
Subscriber access provided by La Trobe University Library

Article

A novel off-gas treatment technology to remove volatile organic contaminants with high concentration Hong Sui, Tao Zhang, Jixing Cui, Xiqing Li, John Crittenden, Xingang Li, and Lin He Ind. Eng. Chem. Res., Just Accepted Manuscript • DOI: 10.1021/acs.iecr.5b02662 • Publication Date (Web): 10 Feb 2016 Downloaded from http://pubs.acs.org on February 17, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Industrial & Engineering Chemistry Research is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 39

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1

A novel off-gas treatment technology to remove volatile

2

organic contaminants with high concentration

3 4

Hong Suia,c,d, Tao Zhangc, Jixing Cuic, Xiqing Lib, John Crittendene, Xingang Li a,c,d, Lin He a,d*

5 6

a

School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072, China

7

b

College of Urban and Environmental Sciences, Peking University, Beijing 10087, China

8

c

National Engineering Research Centre for Distillation Technology, Tianjin 300072, China

9

d

Collaborative Innovation Center of Chemical Science and Engineering (Tianjin), 300072, China

10

e

School of Civil and Environmental Engineering and the Brook Byers Institute for Sustainable

11

Systems, Georgia Institute of Technology, Atlanta, Georgia, 30332-0595, United States

12

*

13

EMAIL: [email protected]

Corresponding author: Lin He

14

1

ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1

Page 2 of 39

Graphic abstract:

2 Clean gas

Flesh solvent (or absorbents)

Regeneration column

Absorption column

Gas stream with high concentrations of VOCs

3 4

Solvents enriched with VOCs

Recovered VOCs

Recycled solvents

2

ACS Paragon Plus Environment

Page 3 of 39

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1

Abstract: :

2

The triethylene glycol (TEG) was used to treat the off-gas stream containing 16

3

volatile organic chemicals (VOCs) with high concentration (up to 15000 ppm) by

4

experimenal solvent absorption and ASPEN Plus computational simulation,

5

respectively. This solvent absorption technology (SAT) does not only purify the

6

off-gas, but also recover the VOCs. The effects of some typical operational

7

parameters, including temperature, pressure, liquid loading rate, ratio of absorption

8

liquid to gas flow rates, and absorption column height, on the absorption efficiency

9

have been systematically investigated. Simulation results show that the optimal

10

operational conditions are determined as: 30 ℃, 0.5 MPa (absolute), recycling TEG

11

(with a purity of 99.9 %) to gas ratio of 4:1 by weight, and 8 theoretical stages. In

12

addition, two stages of thermal coupling are applied to minimizing the energy

13

consumption of off-gas absorption process, leading to a reduction of 89.77 % in

14

energy consumption. Laboratory experiments and field tests show that both VOCs

15

absorption efficiency (using TEG as absorbent) and regeneration efficiency are highly

16

consistent with those of ASPEN Plus simulation, suggesting the feasibility of

17

simulation. Based on pilot-scale experiments, the equipment investment and

18

operational costs of SAT have been calculated and analyzed. Results show that the

19

SAT is comparable with the traditional thermal treatment, but with the advantages of

20

no secondary pollution. These findings indicate that solvent absorption method is a

21

promising green technology for treating high VOCs off-gas.

22

Keywords : off-gas, volatile organic chemicals (VOCs), solvent absorption, 3

ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1

triethylene glycol, ASPEN Plus simulation

4

ACS Paragon Plus Environment

Page 4 of 39

Page 5 of 39

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1

1. Introduction

2

Volatile organic chemicals (VOCs) exist in many places or gas streams, such as oil or

3

gas holders which are used to hold gasoline, jet fuel, heating oil, and other industrial

4

compounds found in soil and groundwater. The discharge of VOCs to the air without

5

treatment is unacceptable due to their toxicity to humans (e.g., carcinogenicity) and

6

ecosystems (e.g., tropospheric ozone)1 Therefore, some

7

standards have been set to restrict their discharge by many countries during the past

8

decades.

stringent professional

9

Two popular methods for VOCs removal from soil and groundwater are soil

10

vapor extraction (SVE) and air stripping (AS)1. In these technologies, further

11

treatments are still required to purify the off-gas before its final discharge to the air,

12

which could be categorized into four groups: thermal treatment, absorption method,

13

biological process and emerging technologies (e.g., photocatalysis and non-thermal

14

plasma treatment)1. Recently, condensation technology has been applied to recovered

15

VOCs from the off-gas vapor stream of SVE or dual phase extraction (DPE) systems2.

16

Among the above technologies, adsorption3, 4 and Biofiltration5, 6 are mainly used for

17

VOCs treatment with low concentrations, typically less than 5,000 and 1,500 ppmv

18

for total VOCs, respectively. However, during these processes, the widely used

19

adsorbent, granular activated carbon (GAC), works poorly when treating VOCs with

20

high polarity or high vapor pressures (i.e., highly volatile compounds)7. While,

21

Biofiltration is found to be sensitive to the variations of operational parameters, such

22

as moisture content, temperature, pH, and nutrient levels1. Although the thermal 5

ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1

method is able to be used to treat the off-gas with a broad range of concentration, it is

2

not suitable to process SVE off-gas with halogenated compounds due to the second

3

pollution by the newly generated acid gases8, 9. Additionally, incomplete combustion

4

would occur if the oxygen was not sufficient or the “three Ts (temperature, time, and

5

turbulence)” were not addressed adequately. Other off-gas treating technologies, such

6

as photocatalytic and non-thermal plasma, are also not being widely commercialized

7

due to their complexity and high cost during operation10-12. The Vapor Condensation

8

(VC) method sometimes works poorly in purifying off-gas containing materials with

9

low boiling point, although it may perform well in treating off-gas with high VOC

10

concentrations at low gas flow rates. In addition, VC would also be difficult in

11

meeting air emission standards due to the constraints of vapor liquid phase

12

equilibrium2.Therefore, due to the unavoidable disadvantages and limitations for the

13

above treatment methods, it is urgent to develop a green process which is capable of

14

removing high-content VOCs from off-gas streams in a cost-effective way.

15

Gas absorption technology has been considered as a promising method for

16

off-gas purification, which was reported in only a few studies13. In some cases, the

17

contaminants (e.g., acid gases) in vapor stream can react with a component in the

18

absorbent solution (e.g., caustic solution). While in some other cases, the

19

contaminants are able to be dissolved into the absorbent solution, which requires

20

further treatment for purifying the rich absorbent and recycling use1. During the past

21

decades, many solvents have been investigated such as water, mineral oils, biodiesel,

22

ionic liquids, vegetable and lubricant oils, and non-volatile petroleum oils14-16. Vuong 6

ACS Paragon Plus Environment

Page 6 of 39

Page 7 of 39

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1

et al.17 used Henry’s constant to characterize the absorption capacity of various

2

VOCs/solvent systems, and used the absorption rate and the overall liquid mass

3

transfer coefficient to evaluate absorption selectivity. Unfortunately, most solvents

4

only work well in absorbing a few kinds of specific VOCs, not all VOCs. Therefore, it

5

is important to screen appropriate solvents which are effective in removing a much

6

wider range of VOCs compositions, and find a reliable way to optimize the

7

operational conditions (a balance of best treat effect and low cost).

8

ASPEN Plus, a process simulation software possessing a powerful database, has

9

been widely used in chemical engineering research and made significant contributions

10

in many fields, such as oil refinery18, 19, off-gas and CO2 absorption from power

11

plant20, 21, coal chemical industry22, 23 and biomass power generation systems24, etc.

12

Here, a potential sight was brought out whether we could combine the process

13

simulation with experiments together, which reduces the operational cost and time for

14

design.

15

Accordingly, the aims of this study are to: a) evaluate VOCs removal efficiency

16

using ASPEN Plus simulation software, b) choose one environmentally friendly

17

absorbent (solvent), which can effectively remove VOCs in off-gas; c) understand the

18

effect of temperature, pressure, the ratio of recycling solvent flowrate to gas flowrate

19

(L/G ratio), absorption tower height and liquid and gas loading rate, on VOCs

20

removal efficiency, d) validate the industrial application; and evaluate the economics

21

of solvent absorption technology using a pilot-scale experimental set.

22

2. Materials and Methods 7

ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1

2.1 Materials

2

All chemicals for bench scale test were purchased at analytical grade from Tianjin

3

Jiangtian Technology Co. Ltd., China. The benzene series (a series of aromatic

4

hydrocarbons derived from benzene by replacing one or more of the hydrogen atoms

5

with one or more methyl groups), including benzene, toluene, xylenes and

6

haloalkanes (e.g., trichloroethylene, 1,1,1-trichloroethane, and methylene chloride),

7

were stored in two 100 ml flasks at the volume ratios, shown in Table 1. Triethylene

8

glycol (TEG) was chosen as the absorbent, because the simulation results suggested

9

that it was the optimal absorbent.

10

2.2 Experimental Solvent Absorption and Regeneration

11

The solvent absorption and regeneration experimental set-up is shown in Figure 1.

12

VOCs were placed in a closed container according to the proportions that were shown

13

in Table 1. An air blower was used to enhance the volatilization and delivery of the

14

VOCs into the absorption column (Φ32 mm × 1 m). The compositions of VOCs in the

15

gas stream were controlled by adjusting the flowmeter according to the quantitative

16

detection by GC with FID detector. The total flowrate of the gas stream was 1 m³•h-1.

17

TEG was sprayed from the top of the column through a sprayer with the flowrate of

18

90 mL•min-1. After absorbing the VOCs, the absorbent enriched with VOCs was

19

collected at the bottom of the absorption column and fed to the regeneration column

20

(Φ 32 mm × 0.6 m height). Gas chromatography (GC) was used to analyze the gas

21

samples from the column when the absorption was equilibrium (~20 minutes later).

22

To determine the industrial and economical feasibility, a pilot plant study with a 8

ACS Paragon Plus Environment

Page 8 of 39

Page 9 of 39

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1

treatment capacity of 500 m3•h-1 was conducted in a chemical plant in Baoding, China.

2

The absorption column and regeneration column were filled with Sulzer structured

3

packings (Mellapac 250Y) with the diameter of 0.35 m and 0.4 m, respectively. A

4

circulating water system was used to cool the absorbent after regeneration and the hot

5

heat-conducting oil which was used to heat the reboiler at the bottom of the

6

regeneration column. The off-gas was extracted from 4 soil vapor extraction wells and

7

was transported to the off-gas absorption column by pipeline. This system ran 20 days

8

continuously.

9

2.3 Simulation Models

10

As shown in Figure 2, a steady state simulation model using ASPEN Plus was

11

developed. Table 2 presented a brief description of each unit operation block shown

12

in ASPEN Plus flowsheet. The absorption column was operated at ambient pressure

13

and temperature. The NRTL thermodynamic model was used in this simulation. The

14

flowrate of off-gas was controlled at 500 m3•h-1 with VOCs at 11.38 kg•h-1 (1.5 wt%

15

of the off-gas b). The compositions of VOCs in off-gas are listed in Table 3.

16

2.4 Analytical Method

17

Total hydrocarbon concentration (without methane) was obtained using Portable

18

VOCs Detector (MiniRAE 3000 PGM 7320) of RAE Systems (Beijing) Co. Ltd. The

19

benzene series were analyzed by GC-FID. The injection and detector temperatures

20

were both set as 250 ºC. The injection volume was 0.2 µL with split ratio of 10:1.

21

VOCs were separated using a HP-5 capillary column (30 m × 0.32 mm internal

22

diameter) and nitrogen was used as the carrier gas. The oven temperature was 9

ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1

increased from 40 ºC to 120 ºC at 5 ºC•min-1 and kept at 120 ºC for 20 min.

2

GC-FID was also used for chlorinated hydrocarbon analysis. The injection and

3

detector temperatures were both set as 200 ºC. The injection volume was 0.2 µL with

4

split ratio of 5:1. VOCs were separated in a PE-FFAP capillary column (30 m × 0.32

5

mm internal diameter × 0.25 µm film thick). The nitrogen gas was used as the carrier

6

gas. The oven was kept at 70 ºC for 15 min.

7 8

3. Simulation Results and Discussion

9

3.1 Different Absorbents

10

To obtain the impact of the absorbent solution, TEG, methyl benzoate, butyrolactone,

11

salicylic acid and N-methyl-2-pyrrolidone (NMP) were used to test their absorption

12

efficiency by process simulation. Table 4 shows that the absorption efficiency of

13

methyl benzoate is the highest among the tested agents. The VOCs effluent

14

concentration reduced sharply to less than 3.85×10-2 (i.e., n-heptane) or even as low

15

as 3.11×10-18 mg•m-3 (i.e., o-xylene) when methyl benzoate was used as adsorbent.

16

However, large amount of absorbents (i.e., methyl benzoate, salicylic acid,

17

butyrolactone and NMP) were found to be lost during absorption due to volatilization

18

(Table 5), which limits their potential application in industry. After careful

19

comparison from the absorption efficiency and long-term operation, TEG was

20

considered as the optimal absorbent due to its high absorption ability to VOCs with

21

the lowest entrainment (1 ppm) in the treated gas. Therefore, TEG was selected as

22

adsorbent for further investigation in the following sections. 10

ACS Paragon Plus Environment

Page 10 of 39

Page 11 of 39

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1 2

3.2 Effect of Temperature and Pressure

3

Temperature and pressure are important operational factors which influence the

4

absorption efficiency. The lower the temperature, the higher the absorption efficiency

5

is. However, considering the energy consumption, the absorption should be better

6

operated at ambient temperature and pressure. Therefore, the simulation conditions

7

were set at the range from 20 to 40 ℃ and 0.1 MPa. Unfortunately, the treated gas did

8

not satisfy GB16297-96 limit level even at 20 ℃ (normal pressure). Take n-pentane as

9

an example, the discharge concentrations at 20 ℃, 30 ℃ and 40 ℃ were 534.6, 592.3

10

and 632.2 mg•m-3, respectively, as shown in Table 6, which were much higher than

11

the discharge standard for total alkanes (