Subscriber access provided by Miami University Libraries
Article
On-capillary Surface Enhanced Raman Spectroscopy: Determination of Glutathione in Whole Blood Microsamples Ángel Sánchez-Illana, Fritz Mayr, Daniel Cuesta-García, José David Piñeiro-Ramos, Andres Cantarero, Miguel De La Guardia, Maximo Vento, Bernhard Lendl, Guillermo Quintas, and Julia Kuligowski Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.8b01492 • Publication Date (Web): 25 Jun 2018 Downloaded from http://pubs.acs.org on June 25, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
On-capillary Surface Enhanced Raman Spectroscopy: Determination of Glutathione in Whole Blood Microsamples Ángel Sánchez-Illanaa‡, Fritz Mayra‡, Daniel Cuesta-Garcíaa,b, José David Piñeiro-Ramosa, Andrés Cantarerob, Miguel de la Guardiac, Máximo Ventoa,d, Bernhard Lendle, Guillermo Quintásf,g*, Julia Kuligowskia* a
Neonatal Research Unit, Health Research Institute La Fe, Avda Fernando Abril Martorell 106, 46026 Valencia, Spain b Molecular Science Institute, University of Valencia , PO Box 22085, 46071 Valencia, Spain c Department of Analytical Chemistry, University of Valencia, 50 Dr. Moliner Street, 46100 Burjassot, Valencia, Spain b Division of Neonatology, University & Polytechnic Hospital La Fe, Avda Fernando Abril Martorell 106, 46026 Valencia, Spain e Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/151, A-1060 Vienna, Austria f Health and Biomedicine, Leitat Technological Center, Avda Fernando Abril Martorell 106, 46026 Valencia, Spain g Analytical Unit, Health Research Institute Hospital La Fe, Avda Fernando Abril Martorell 106, 46026 Valencia, Spain ‡ both authors contributed equally * e-mail:
[email protected];
[email protected] ABSTRACT Oxidative stress monitoring in the neonatal period supports early outcome prediction and treatment. Glutathione (GSH) is the most abundant antioxidant in most cells and tissues, including whole blood, and its usefulness as a biomarker has been known for decades. To date, the available methods for GSH determination require laborious sample processing and the use of sophisticated laboratory equipment. To the best of our knowledge, no tools suitable for point-of-care (PoC) sensing have been reported. Surface Enhanced Raman Spectroscopy (SERS), performed in a micro-volume capillary measurement cell, is proposed in this study as a robust approach for the quantification of GSH in human whole blood samples. The use of a silver colloid allowed a highly selective signal enhancement for GSH providing Analytical Enhancement Factors of three to four orders of magnitude. A highly accurate determination of GSH in whole blood samples with recoveries ranging from 99 to 107% and relative standard deviations ≤18% were achieved by signal normalization with the intensity of an isotopically labelled internal standard. GSH concentrations were retrieved within 4 min using small volume blood samples (2 µL). The developed procedure was applied to the analysis of blood of 20 healthy adults and 36 newborns, obtaining comparable results between literature and those found by SERS and a reference method. The characteristics of this novel tool are suitable for its implementation in a portable optical sensor device enabling PoC testing of oxidative stress levels in newborns. 1 ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 2 of 25
Keywords: Surface Enhanced Raman Scattering (SERS), isotopically labelled internal standard (IS), glutathione (GSH), oxidative stress, whole blood, silver colloid
2 ACS Paragon Plus Environment
Page 3 of 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
Under normal conditions, arterial oxygen saturation in the fetal-to-neonatal transition rises from 55% in the fetus up to >95% in the newly born infant within approximately 10 min, generating physiologic oxidative stress1,2. However, in very preterm infants (i.e.