On-Pellet Digestion

Aug 5, 2018 - Surfactant Cocktail-Aided Extraction/Precipitation/On-Pellet Digestion Strategy Enables Efficient and Reproducible Sample Preparation fo...
0 downloads 0 Views 2MB Size
Subscriber access provided by UNIV OF DURHAM

Article

A Surfactant Cocktail-Aided Extraction/Precipitation/On-Pellet Digestion (SEPOD) Strategy Enables Rapid, Efficient and Reproducible Sample Preparation for Large-Scale Quantitative Proteomics Shichen Shen, Bo An, Xue Wang, Shannon P. Hilchey, Jun Li, Jin Cao, Yu Tian, Chenqi Hu, Liang Jin, Andrew Ng, Chengjian Tu, Miao Qu, Martin ZAnd, and Jun Qu Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.8b02172 • Publication Date (Web): 05 Aug 2018 Downloaded from http://pubs.acs.org on August 6, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

A Surfactant Cocktail-Aided Extraction/Precipitation/On-Pellet Digestion (SEPOD) Strategy Enables Rapid, Efficient and Reproducible Sample Preparation for Large-Scale Quantitative Proteomics #

Shichen Shen1,2, #Bo An1,2, Xue Wang2,3, Shannon P. Hilchey4, Jun Li1,2, Jin Cao5, Yu Tian6,

Chenqi Hu6, Liang Jin6, Andrew Ng2,7, Chengjian Tu1,2, *Miao Qu8, *Martin S. Zand4, *Jun Qu1,2 1

Department of Pharmaceutical Sciences, SUNY at Buffalo, Buffalo, NY 14214;

2

New York State

Center of Excellence in Bioinformatics & Life Sciences, Buffalo, NY, Buffalo, NY 14203; Park Cancer Institute, Buffalo, NY, Buffalo, NY 14263; Rochester Medical Center, Rochester, NY 14642;

5

4

3

Roswell

Division of Nephrology, University of

National Institute for Food and Drug Control,

Beijing, China 100050; 6AbbVie Bioresearch Center Inc., Worcester, MA 01605; 7 School of Dental Medicine, SUNY at Buffalo, Buffalo, NY 14214; 8 Department of Neurology, XuanWu Hospital, Capital University of Medicine, Beijing, China 100053;

#

The authors contributed equally to this article.

*

Corresponding Authors

Miao Qu, M.D., Ph.D. Department of Neurology, XuanWu Hospital, Capital University of Medicine, 45 Changchun Street, Beijing, China 100053 Phone: +86 13621104599 E-mail: [email protected]

ACS Paragon Plus Environment

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Martin S. Zand, M.D., Ph.D. Division of Nephrology, Strong Memorial Hospital 601 Elmwood Ave, AC-3 University of Rochester Medical Center, Rochester, NY 14642 Phone: (585)273-2819 E-mail: [email protected]

Jun Qu, Ph.D. Department of Pharmaceutical Sciences, 318 Kapoor Hall, State University of New York at Buffalo, Buffalo, NY 14214-1200 Phone: (716) 645-4821 Fax: (716) 645-3693 E-mail: [email protected]

ACS Paragon Plus Environment

Page 2 of 35

Page 3 of 35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Abstract For quantitative proteomics, efficient, robust, and reproducible sample preparation with high throughput is critical yet challenging, especially when large cohorts are involved, as is often required by clinical/pharmaceutical studies. We describe a rapid and straightforward surfactant cocktail-aided extraction/precipitation/on-pellet digestion(SEPOD) strategy to address this need. Prior to organic solvent precipitation and on-pellet digestion, SEPOD treats samples with a surfactant cocktail(SC) containing multiple non-ionic/anionic surfactants, which achieves: i)exhaustive/reproducible protein extraction, including membrane-bound proteins; ii)effective removal of detrimental non-protein matrix components(e.g.>94%

of phospholipids);

iii)rapid/efficient

proteolytic

digestion

owing

to

dual(surfactants+precipitation) denaturation. The optimal SC composition and concentrations were determined by Orthogonal-Array-Design investigation of their collective/individuals effects on protein extraction/denaturation. Key parameters for cleanup and digestion were experimentally identified as well. The optimized SEPOD procedures allowed a rapid 6h digestion providing a clean digest with high peptide yields and excellent quantitative reproducibility(esp.low-abundance proteins). Compared with filter-assisted sample preparation (FASP) and In-solution digestion, SEPOD showed superior performance by recovering substantially more peptide/proteins(including integral membrane proteins), yielding significantly higher peptide intensities, and improving quantification for peptides with extreme physicochemical properties. SEPOD was further applied in a large-cohort temporal investigation of 44 IAV-infected mouse lungs, providing efficient and reproducible peptide yields(77.9±4.6 %) across all samples. With the IonStar pipeline, >6,400 unique protein groups were quantified(≥2-peptide/protein, peptide-FDR