optimized sampling conditions for fecal volatile organic compounds

controls (HC) were used to assess effects of sampling conditions compared to .... Sample collection IBD and controls .... The flow rate was set on 2.0...
1 downloads 0 Views 927KB Size
Subscriber access provided by the Henry Madden Library | California State University, Fresno

Article

OPTIMIZED SAMPLING CONDITIONS FOR FECAL VOLATILE ORGANIC COMPOUNDS ANALYSIS BY MEANS OF FIELD ASYMMETRIC ION MOBILITY SPECTROMETRY Sofie Bosch, Sofia el Manouni el Hassani, James A. Covington, Alfian N Wicaksono, Marije K Bomers, Marc A Benninga, Chris JJ Mulder, Nanne KH de Boer, and Tim GJ de Meij Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.8b00688 • Publication Date (Web): 03 Jun 2018 Downloaded from http://pubs.acs.org on June 4, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 34 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

1

OPTIMIZED SAMPLING CONDITIONS FOR FECAL VOLATILE ORGANIC COMPOUNDS ANALYSIS

2

BY MEANS OF FIELD ASYMMETRIC ION MOBILITY SPECTROMETRY.

3 5

Sofie Bosch1, MD*, Sofia el Manouni el Hassani4, MD*, James A Covington2, Phd, Alfian N. Wicaksono2, SSi, Marije K Bomers3, MD, PhD, Marc A Benninga4, MD, PhD, Chris JJ Mulder, MD, PhD1, Nanne KH de Boer1, MD, PhD**, Tim GJ de Meij4, MD, PhD**

6

* Shared first, listed alphabetically

7

** Shared last, listed alphabetically

4

8 1

9 10

Department of Gastroenterology and Hepatology, VU University Medical Center, Amsterdam, The Netherlands

11

2

12

3

13

4

14

Amsterdam, The Netherlands

15 16

School of Engineering, University of Warwick, Coventry, United Kingdom Department of Internal Medicine, VU University Medical Center, Amsterdam, The Netherlands Department Pediatric Gastroenterology, Emma Children’s Hospital/Academic Medical Center,

5

Department Pediatric Gastroenterology, VU University Medical Center, Amsterdam, The

Netherlands

17

1 ACS Paragon Plus Environment

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 34

1

Conflicts of interest

2

The department of Gastroenterology and Hepatology of the VU University Medical Center

3

has no conflicts of interest to disclose

4

Financial disclosures

5

S Bosch has nothing to declare.

6

S el Manouni el Hassani has nothing to declare.

7

JA Covington has nothing to declare.

8

AN Wicaksono has nothing to declare.

9

MK Bomers has nothing to declare.

10

CJJ Mulder has served as a principal investigator for TEVA Pharma BV. He has received a

11

research grant from TEVA Pharma BV.

12

MA Benninga has served as speaker for Abbott and FrieslandCampina. He has served as

13

consultant for Shire, Takeda, Norgine, AstraZeneca, Danone, Friesland Campina, Novalac and

14

Mead Johnson

15

NKH de Boer has served as a speaker for AbbVie and MSD. He has served as consultant and

16

principal investigator for TEVA Pharma BV and Takeda. He has received a (unrestricted)

17

research grant from Dr. Falk and Takeda.

18

TGJ de Meij has served as a speaker for Mead Johnson. He has received a (unrestricted)

19

research grant from Danone

20 2 ACS Paragon Plus Environment

Page 3 of 34 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

1

Author contributions

2

TGJ de Meij and NKH de Boer were the guarantors of this article.

3

S el Manouni el Hassani and S Bosch collected the fecal samples and performed VOC

4

analysis.

5

JA Covington and AN Wicaksono analyzed the results.

6

S Bosch drafted the first version of the manuscript.

7

S el Manouni el Hassani, JA Covington, AN Wicoksono, MK Bomers, CJ Mulder, MA Benninga,

8

KHN de Boer, TGJ de Meij reviewed the manuscript for important intellectual content.

9

S Bosch finalized the manuscript.

10

All authors agreed to the final version of the manuscript.

11

Running title Optimized sampling conditions for fecal volatile organic compounds by means

12

of field asymmetric ion mobility spectrometry.

13 14

Word count 4423

15

Version 3.0

16

Key words Volatile organic compounds, VOC, Lonestar, FAIMS, Field Asymmetric Ion

17

Mobility Spectrometry, Inflammatory bowel disease,

18

3 ACS Paragon Plus Environment

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1

Corresponding author

2

Sofie Bosch, MD

3

Department of Gastroenterology and Hepatology

4

VU University Medical Center

5

Room PK 2X 136

6

De Boelelaan 1117

7

1081 HV Amsterdam

8

T: +31 (0)20 444 07 99

9

F: +31 (0)20 444 05 54.

10

Page 4 of 34

E: [email protected]

11

4 ACS Paragon Plus Environment

Page 5 of 34 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

1

Abstract (259 words)

2

Background Fecal volatile organic compounds (VOCs) are increasingly considered as

3

potential non-invasive, diagnostic biomarkers for various gastrointestinal diseases.

4

Knowledge of influence of sampling conditions on VOC outcomes is limited. We aimed to

5

evaluate effects of sampling conditions on fecal VOC profiles and to assess under which

6

conditions an optimal diagnostic accuracy in the discrimination between pediatric

7

inflammatory bowel disease (IBD) and controls could be obtained.

8

Methods Fecal samples from de novo treatment-naïve pediatric IBD patients and healthy

9

controls (HC) were used to assess effects of sampling conditions compared to the standard

10

operating procedure (reference standard), defined as 500mg of sample mass, diluted with

11

10mL tap water, using field asymmetric ion mobility spectrometry (FAIMS).

12

Results A total of 17 IBD (15CD and 2 UC) and 25 HC were included. IBD and HC could be

13