oriel corporation - American Chemical Society

is determined by the rate of TMAE consumption relative to the ... with a fiber optic but readilycould be. ... BROADBAND GENERAL ILLUMINAXLC. 250 LONG ...
3 downloads 0 Views 1MB Size
VERSATILITY in

ANALYTICAL INSTRUMENTATION ORIEL'S modular design enables a DO-IT-YOURSELF component approach for SPECTROFLUORIMETRY ABSORPTION MEASUREMENTS TRANSMISSION MEASUREMENTS SCATTERING MEASUREMENTS MONOCHROMATIC ILLUMINATION SPECTRORADIOMETRY BROADBAND GENERAL ILLUMINAHQffe

Figure 6. N o n r e v e r s i b l e 0 2 sensor 0 2 diffuses through Teflon membrane, M, into reagent phase, R, where it reacts to yield chemiluminescence measured by detection system, D

steady-state mass transfer to get a constant signal. Any processes that perturb mass transfer are potential sources of error. The difference between reversible and nonreversible optical sensors is similar to the difference between potentiometric and amperometric electrodes. Amperometric electrodes, like nonreversible optical sensors, involve a reaction and require mass transfer to an electrode surface. The use of tetrakis(dimethylaminoethylene) (TMAE) to measure oxygen serves as an example of a nonreversible sensor (13). The device is illustrated in Figure 6. Oxygen in the sample diffuses through a hydrophobic 02-permeable membrane into a reservoir of TMAE. There it reacts with TMAE yielding chemiluminescence, which is measured by a light detection system. (No probe radiation is required for this device.) Steadystate chemiluminescence is proportional to the partial pressure of oxygen. Both the flow rate of O2 past the membrane and the temperature affect response because they affect the steady-state supply of 0 2 into the reagent phase. The lifetime of the sensor is determined by the rate of TMAE consumption relative to the total TMAE available. The lifetime can be quite long—months and even years— if a large TMAE reservoir is used with a low rate of oxygen permeation. Again, it should be noted that this particular reagent was not combined with a fiber optic but readily could be. Other nonreversible sensors include U 0 2 + and halide sensors (1). These devices differ from the O2 sensor in

For detail information write or call:

O R I E L CORPORATION 250 LONG BEACH BLVD., R0. BOX 872, STRATFORD. CT 06497 · [203) 377-8282 TWX 710-453-8719 FEDERAL REPUBLIC OF GERMANY ORIEL GmbH D a r m s t a d t . :06151) 83076

FRANCE ORIEL S.A.R.L Paris 371-00-60

UNITED KINGDOM ORIEL SCIENTIFIC, LTD Kingston-upon-Thames, Surrev 01 5d9 4525

ITALY ORIEL SRL Mliarto, 02-5392188

SWITZERLAND ORIEL Bureau Suisse Morges, 21-879509

CIRCLE 157 ON READER SERVICE CARD

FREE CATALOG Witty and wonderful!

ACS T-shirts Barbecue/lab aprons Tote bags And more! Experiment w i t h a Chemist! I have Designer Genes! Chemistry Spoken Here! A n d lots more! Choose your sentiment and wear it close t o your heart w i t h ACS sportswear. Sizes for men, w o m e n , and children. Quantity discounts, t o o . C a l l ( 2 0 2 ) 872-4588 o r m a i l coupon b e l o w for y o u r free c a t a l o g today.

Ed ucation Division, American Chemical Society 155 Sixteenth Street, N.W., Washington, D.C. 20036 3

lei se send free catalog listing ACS T-shirts and other ite < ;. NameAddress City, State, Zip_

ANALYTICAL CHEMISTRY, VOL. 56, NO. 1, JANUARY 1984 · 33 A