Subscriber access provided by Binghamton University | Libraries
Article
Performance and Mechanisms of Ultrafiltration Membrane Fouling Mitigation by Coupling Coagulation and Applied Electric Field in a Novel Electrocoagulation Membrane Reactor Jingqiu Sun, Chengzhi Hu, Tiezheng Tong, Kai Zhao, Jiuhui Qu, Huijuan Liu, and Menachem Elimelech Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b01189 • Publication Date (Web): 11 Jul 2017 Downloaded from http://pubs.acs.org on July 12, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 23
Environmental Science & Technology
1 2
Performance and Mechanisms of Ultrafiltration
3
Membrane Fouling Mitigation by Coupling
4
Coagulation and Applied Electric Field in a Novel
5
Electrocoagulation Membrane Reactor
6 7 8
Jingqiu Sun1, 2, Chengzhi Hu1, 3*, Tiezheng Tong3, Kai Zhao1, Jiuhui Qu1, Huijuan
9
Liu1, Menachem Elimelech3
10
1
11
Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China 2
12 13
Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-
3
University of Chinese Academy of Sciences, Beijing 100049, China
Department of Chemical and Environmental Engineering, Yale University, New Haven,
14
Connecticut 06520-8286, United States
15 16
*Corresponding
author: e-mail address:
[email protected] (C.H.); Tel: +86-10-62849160; Fax:
17
+86-10-62849160; Add: 18 Shuangqing Road, Haidian District, Beijing, 10085, P.R. China.
18
ACS Paragon Plus Environment
Environmental Science & Technology
19
ABSTRACT
20
A novel electrocoagulation membrane reactor (ECMR) was developed, in which ultrafiltration
21
(UF) membrane modules are placed between electrodes to improve effluent water quality and
22
reduce membrane fouling. Experiments with feed water containing clays (kaolinite) and natural
23
organic matter (humic acid) revealed that the combined effect of coagulation and electric field
24
mitigated membrane fouling in the ECMR, resulting in higher water flux than the conventional
25
combination of electrocoagulation and UF in separate units (EC-UF). Higher current densities
26
and weakly acidic pH in the EMCR favored faster generation of large flocs and effectively
27
reduced membrane pore blocking. The hydraulic resistance of the formed cake layers on the
28
membrane surface in ECMR was reduced due to an increase in cake layer porosity and polarity,
29
induced by both coagulation and the applied electric field. The formation of a polarized cake
30
layer was controlled by the applied current density and voltage, with cake layers formed under
31
higher electric field strengths showing higher porosity and hydrophilicity. Compared to EC-UF,
32
ECMR has a smaller footprint and could achieve significant energy savings due to improved
33
fouling resistance and a more compact reactor design.
34 35
TOC Art
36 37
1 ACS Paragon Plus Environment
Page 2 of 23
Page 3 of 23
Environmental Science & Technology
38
INTRODUCTION
39
Pressure-driven membrane filtration technologies are widely used in water treatment.1
40
Ultrafiltration (UF) in particular is commonly employed in drinking water treatment because it
41
removes multiple contaminants in one step and is economically feasible.2,
42
inherently constrained by membrane fouling, with dissolved organic substances (e.g., humic acid
43
and proteins) acting as major foulants.4-6 Membrane fouling compromises the performance and
44
lifetime of UF membranes, increasing the cost and energy demand of UF systems. Therefore,
45
effective strategies for fouling mitigation are highly desirable to improve the efficiency and
46
applicability of UF systems.7
3
However, UF is
47
Electrocoagulation (EC) is an attractive process in water treatment, and its performance and
48
mechanisms have been widely investigated.8 Since EC could effectively remove particles and
49
humic acid from raw water, applying EC as a pretreatment step is one of the promising solutions
50
to control UF membrane fouling.9-14 The properties of flocs generated by EC have a significant
51
influence on the structure of membrane cake layers and the extent of membrane fouling.9, 11 For
52
example, it has been reported that the steady-state normalized specific water flux increased from
53
51% for microfiltration to 72% for electrocoagulation-microfiltration.15 If the porosity and
54
structure of the formed cake layer can be effectively controlled in the EC process, a highly
55
porous protective layer could be formed to further alleviate membrane fouling.
56
Applied electric field has also been considered as an efficient method to reduce membrane 16-18
57
fouling.
It has been demonstrated that deposition of charged foulants, such as humic acid
58
and inorganic particles, was prevented by electrostatic repulsion induced by an electric field.19, 20
59
In this case, charged foulants migrate away from the membrane surface by electrostatic force.21,
60
22
61
fouling.23 Although electric field can alter the dipole moment of organic foulants, its effect on
62
cake layer structure has not been investigated. Furthermore, previous studies typically combined
63
EC with membrane filtration as separate units8, 24, 25, in which membranes were located outside
64
of the electric field zone. We hypothesize that when EC and UF are integrated in one unit,
65
membrane fouling would be mitigated by the combined effect of both coagulation and electric
66
field, leading to further improvement of membrane fouling control.
It was further suggested that the dipole moment of foulants can also influence membrane
2 ACS Paragon Plus Environment
Environmental Science & Technology
67
In this study, we designed an integrated electrocoagulation membrane reactor (ECMR), with
68
membrane modules placed between a pair of electrodes. We evaluated the efficiency of ECMR
69
in mitigating membrane fouling, and analyzed the effect of electrochemical parameters on the
70
ECMR performance. To better understand the antifouling mechanisms of ECMR, we focused on
71
the evolution of particle size and cake layer polarity in ECMR, which are influenced by
72
coagulation and electric field, respectively. Our study is the first to propose the concept of
73
ECMR and systematically delineate its design and working principles.
74
MATERIALS AND METHODS
75
Chemicals and Synthetic Feed Water. A stock solution of humic acid (Sigma-Aldrich,
76
U.S.A) was prepared in deionized water (DI, Millipore Milli-Q) after filtration through a 0.45
77
µm mixed cellulose ester membrane. The molecular weight of humic acid was mainly distributed
78
around ~270 kDa and ~10 kDa (Figure S1).The prepared stock solution had a dissolved organic
79
carbon (DOC) concentration of 777±20 mg/L and was stored at 4 °C until use. Sodium chloride
80
(50 mM) was added in the synthetic feed water as the background electrolyte, and sodium
81
bicarbonate (0.5 mM) was used to provide a buffer capacity. DOC of the synthetic feed water
82
was adjusted to 5 mg/L and clay (kaolinite) concentration to 50 mg/L. Sodium hydroxide and
83
hydrochloric acid were used to adjust the solution pH for experiments investigating the effect of
84
pH on ECMR performance. Sodium chloride, sodium bicarbonate, sodium hydroxide, and
85
hydrochloric acid were received at analytical pure grade; kaolinite was at chemical pure grade
86
with particle size ranging from ~400 to ~1200 nm (Figure S2). The ATR-FTIR spectra of humic
87
acid and kaolinite are presented in Figure S3. All reagents were purchased from Sinopharm
88
Chemical Regent Co., Ltd, China.
89
ECMR System and Membrane Fouling Experiments. Figure 1 describes the design
90
of the ECMR system and membrane modules. The UF membrane module was placed between
91
two plate electrodes, so that both the EC process and applied electric field could work in concert
92
to mitigate membrane fouling in one unit. When the membrane module was placed outside the
93
electrodes, the process was considered as an EC-UF system instead of ECMR. Unlike other
94
systems that combined (electro) coagulation with ultrafiltration or microfiltration10, 15, 26, EC-UF
95
was performed in one single reactor in our study. The effective volume of the reactor was 735
96
mL (14 cm ×5 cm ×10.5 cm). As shown in Figure 1b, hollow fiber membranes (PVDF, Tianjin
3 ACS Paragon Plus Environment
Page 4 of 23
Page 5 of 23
Environmental Science & Technology
97
MOTIMO Membrane Technology Co., Ltd., China) were used in the UF system. A membrane
98
module composed of ten fibers with a length of 3 cm was employed to provide an effective
99
membrane area of 24 cm2. A small tube was placed on top of the membrane module for permeate
100
collection. According to the manufacturer, the membrane average molecular weight cutoff was
101
100 kDa, which is corresponding to an average pore size of ~30 nm.
102
FIGURE 1
103
In each experiment, 1.4 L of synthetic feed water was recycled by two peristaltic pumps (36
104
mL/min) in order to generate cross-flow and keep a constant water level in the ECMR system
105
(Figure 1 and Figure S4). The membrane module was placed between two aluminum electrodes
106
parallel to the water flow, with the distance between the two electrodes fixed at 2.5 cm. The feed
107
water was well mixed by a magnetic stirrer at 300 rpm. A digital balance (ME2002E, Mettler
108
Toledo, Switzerland) connected to a personal computer was used to record the mass of permeate
109
during system operation. A pressure sensor was employed to monitor the transmembrane
110
pressure, which was maintained at 30 kPa by a peristaltic pump. The initial water flux of each
111
membrane module was 96.25 L·m-1·h-1. Unless otherwise specified, pH was adjusted to 7.0 and
112
the current density was 10 A/m2. When investigating the effects of electric field strength on
113
membrane fouling, different electrolyte concentrations were used to keep the current density
114
constant. The electrolyte concentration (measured as conductivity) exhibited little effect on water
115
flux in our experiments (Figure S5).
116
Analytical Methods. UV absorbance at 254 nm (UV254) was measured by an ultraviolet-
117
visible spectrophotometer (U-3010, Hitachi High Technologies Co., Japan) as an indicator of
118
humic acid concentration. Dissolved organic carbon (DOC, after filtration through 0.45 µm
119
mixed cellulose ester membranes) was determined with a total organic carbon (TOC) analyzer
120
(TOC-VCPH, Shimadzu, Japan).
121
In order to investigate cake layer properties, fouled membrane fibers were cut from the
122
membrane modules and dried at room temperature for 24 h. In the preparation of cross-section
123
samples of membranes, the hollow fiber membranes were frozen in liquid nitrogen, and then cut
124
instantly to preserve the cake layer attached to the membrane surface. The pristine and fouled
125
membrane samples were platinum-coated by a sputter and observed under a scanning electron 4 ACS Paragon Plus Environment
Environmental Science & Technology
126
microscope (SEM, JSM7401F, JEDL, Japan). Attenuated total reflectance Fourier transform
127
infrared (ATR-FTIR) spectra were collected by a Fourier Transform Infrared Spectrometer
128
(Nicolet 8700, Thermo Fisher Scientific, USA). Furthermore, the hydrophilicity of the fouled
129
membranes formed under different electric fields was measured by a dynamic contact angle
130
tensiometer (Data Physics DCAT, LPD Lab Services Ltd., UK). Floc size as a function of time
131
was directly monitored by a laser particle size analyzer (Mastersizer 2000, Malvern, UK).27 The
132
flocs were monitored by pumping water through the optical unit of the laser particle size
133
analyzer and back into the reactor by a peristaltic pump on the return tube (5 mm internal
134
diameter). Particle size was recorded every 20 seconds during the experiments by a computer.
135
RESULTS AND DISCUSSION
136
Performance of ECMR. The removal rate of humic acid (as measured by UV254) and
137
membrane water flux were measured to evaluate the performance of ECMR compared to EC-UF,
138
EC, and UF (Figure 2). As shown in Figure 2a, the removal rate of humic acid by ECMR
139
attained 93.7±0.2% within 10 minutes and maintained the same level afterwards. This removal
140
rate was comparable to that of EC-UF (94.0±2.5%), but significantly higher than those of EC
141
(61.1±2.9%) and UF (51.3±3.0%). For UF, size exclusion is the main mechanism for humic acid
142
removal. The low removal efficiency of humic acid by UF indicates that humic acid
143
macromolecules smaller than the membrane pore size were able to pass through the UF
144
membrane. Although higher removal efficiency (~80%) could be achieved by EC than UF,
145
longer time was needed for floc sedimentation. The ECMR and EC-UF processes combined the
146
advantages of the EC and UF processes to achieve a much higher removal efficiency of humic
147
acid within a short time.
148
FIGURE 2
149
As shown in Figure 2b, water flux decline of ECMR caused by membrane fouling was less
150
than that observed with EC-UF and UF. The flux decline curves for ECMR and EC-UF exhibited
151
two stages that corresponded to different fouling mechanisms, consistent with the pore
152
blockage–cake filtration model developed by Ho and Zydney.28 This model accounts for a
153
smooth transition of fouling mechanism from pore blockage to cake formation during filtration,
154
and has been successfully used in investigating humic acid fouling in microfiltration.29 Our
155
observation indicates that initial fouling was due to deposition of humic acid aggregates on the 5 ACS Paragon Plus Environment
Page 6 of 23
Page 7 of 23
Environmental Science & Technology
156
membrane surface blocking membrane pores, followed by formation of a cake layer on the
157
regions of membrane that had been covered by the foulant aggregates.
158
The water flux for UF alone decreased continuously within 15 min, suggesting that pore
159
blocking played a primary role. In contrast, a rapid flux decline was only observed in the
160
beginning period (i.e., the first 4-7 min) for ECMR and EC-UF. After this initial period, the
161
water flux was maintained at a relatively steady level, indicating that a cake layer had been
162
formed on the membrane surface. This two-stage mode of flux decline was consistent with the
163
results reported in other studies (Table S1).30-32 The final relative water flux, J/J0, of the ECMR
164
(87.2%) was higher than that of EC-UF (77.8%). Therefore, ECMR achieved comparable humic
165
acid rejection but provided a higher water flux than EC-UF. This finding indicates that
166
coagulation and electric field likely influence the structure and physicochemical properties of the
167
formed cake layer, which will be discussed in more detail in the following subsections.
168
Key Operational Parameters Governing EMCR Fouling Behavior. Water flux
169
decline by pore blockage mechanism depends on foulant size.33 Severe membrane fouling can be
170
caused by pore blocking when the particle size is comparable to the membrane pore size. As the
171
EC process proceeds, particle size increases in the coagulation process.34, 35 Furthermore, current
172
density and pH could control aluminum coagulant dosage and hydrolysis rate, respectively,
173
thereby leading to different sizes of generated flocs.36
174
FIGURE 3
175
As shown in Figure 3a, an increase of current density promoted fouling resistance in ECMR.
176
Under a current density of 2 A/m2, the water flux of ECMR decreased to 70.5% of the initial
177
value and kept steady afterwards. When the current density increased to 10 A/m2 and 20 A/m2,
178
the water fluxes were maintained at 83.1% and 97.3% of the original flux, respectively.
179
Furthermore, the applied current density influenced the growth of particles formed in ECMR. As
180
shown in Figure 3b, particles kept stable at first and then started to grow in size rapidly at 2 min,
181
4 min, and 11 min under current densities of 20 A/m2, 10 A/m2, and 2 A/m2, respectively.
182
Notably, this critical time for particle growth roughly matched the inflection point of the flux
183
decline curve when water flux became stable.
6 ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 23
184
The electric field strengths varied with the different current densities applied in ECMR,
185
thereby creating two variables (electric field strength and current density) that potentially
186
influenced membrane fouling. This dependence may interfere with the interpretation of the
187
observed flux decline curves under different current densities (Figure 3). Therefore, the effect of
188
current density on water flux was investigated in EC-UF (i.e. UF membrane outside the reactor
189
and under no electric field) to exclude the concomitant influence of electric field. As shown in
190
Figure S6, the trend of flux decline under various current densities in EC-UF was consistent with
191
that in ECMR. This observation suggests that higher current densities produced more aluminum
192
coagulant species per unit time, thus enhancing aggregation of foulants (humic acid and kaolinite)
193
and reducing membrane fouling.
194 195
FIGURE 4 Solution pH also influenced EMCR performance because pH governs the coagulation
196
mechanisms and the growth of particles by metal salt coagulants.35,
37, 38
197
previous work38, lower solution pH resulted in a more rapid growth of flocs with a more porous
198
structure, which might contribute to the mitigation of membrane fouling. As shown in Figure 4a,
199
J/J0 reached a steady state of 94.7% at pH 4.0, whereas it decreased to 87.6% and 77.4% at pH
200
7.0 and 9.0, respectively. Figure 4b shows that the particle size kept small initially and then
201
started to grow rapidly at 2 min, 4 min, and 6 min for pH at 4.0, 7.0, and 9.0, respectively.
202
Consistent with the phenomenon observed in Figure 3, the time when particle size started to
203
increase roughly matched the inflection point of the flux decline curves for every pH, which
204
underscores the importance of particle size in reducing membrane fouling in ECMR.
According to our
205
Our results demonstrate that current density and solution pH are two critical parameters for
206
membrane fouling control in ECMR. Hence, proper control of these operational parameters
207
could be used to optimize membrane resistance to pore blocking.
208
Cake Layer Properties under Applied Electric Field. Water flux decline curves
209
under various initial electric field strengths are presented in Figure 5. The current density was
210
kept constant, whereas the electric field strength was varied by altering the electric conductivity
211
of the feed solutions. Electrolyte concentration (measured as conductivity) exhibited negligible
212
effect on membrane fouling and humic acid removal in our experiments (Figure S5 and S7). 7 ACS Paragon Plus Environment
Page 9 of 23
Environmental Science & Technology
213
Feed solutions with lower conductivities resulted in stronger electric field strengths. Results
214
show that the final normalized water flux (J/J0) was positively correlated to the initial strength of
215
the electric field. Specifically, J/J0 values were 85.4%, 91.0%, and 94.9% under electric field
216
strengths of 0.5 V/cm, 1 V/cm, and 2 V/cm, respectively. Polarization effects induced by the
217
electric field likely played an important role in membrane fouling, especially during the process
218
of cake layer formation, as also recently observed by Fan et al.20. To further explore this
219
observation, we analyzed the morphology and hydrophilicity of the fouled membranes in order to
220
understand the alteration of cake layer properties under different electric fields.
221
FIGURE 5
222
The surface morphologies of the fouled membranes subjected to different electric field
223
strengths were observed by SEM (Figure 6a-c). The cake layers formed under different electric
224
field showed similar compositions (Figure S8). But when the strength of electric field increased,
225
the cake layer showed a more irregular and rougher surface with enhanced porosity. The
226
observed average pore sizes of the cake/fouling layers were 7.9 nm, 12.6 nm, and 12.8 nm under
227
electric field strengths of 0.5 V/cm, 1 V/cm, and 2 V/cm, respectively (Figure S9). Also, the
228
thickness of cake layers was larger at higher electric field strengths (Figure 6d-f).
229
FIGURE 6
230
As the electric field increases, the structure of the formed cake layers is increasingly
231
influenced by orientation polarization.40 Negatively charged functional groups would orient
232
toward the anode and positively charged groups would orient toward the cathode, which results
233
in more functional groups oriented parallel to the direction of electric field. In addition, the
234
surface charge of the foulants could be enhanced by displacement polarization.41 The foulant
235
molecules would be stretched along the direction of electric field, and the end functional groups
236
on foulants could concentrate more charges. Therefore, the interaction between foulants is
237
strengthened in the direction parallel to electric field. In contrast, this interaction was weakened
238
perpendicular to electric field, resulting in an increased pore size of cake layers. According to
239
this mechanism, charged foulants under higher electric field strengths were more prone to be
240
connected to attach to the membrane surface, contributing to an increase of cake layer thickness.
241
FIGURE 7 8 ACS Paragon Plus Environment
Environmental Science & Technology
Page 10 of 23
242
Figure 7 indicates that cake layers formed under higher electric field strengths were more
243
hydrophilic than those formed at a lower electric field strength. As the electric field strength
244
increased from 0.5 V/cm to 2 V/cm, the water contact angle of the fouled membrane surface
245
decreased from 114.7±5.3 ° to 99.4±6.3 ° (Figure 7a). It has been reported that a more
246
hydrophilic cake layer resulted in a greater membrane fouling resistance in UF.42 Furthermore,
247
ATR-FTIR was used to characterize the surface functionality of the fouled membranes. The
248
peaks at 2850~2880 cm-1, 2930 cm-1 (aliphatic C-H stretching), and 3300 cm-1 (O-H stretching
249
vibration), which are characteristic for humic substances,36, 43-45 showed higher signals as the
250
electric fields increased from 0 V/cm to 2 V/cm (Figure 7b). This result indicates an increase of
251
humic acid amount in the cake layers, which was in agreement with the thicker cake layer
252
observed at higher electric field strengths. Many functional groups of humic acid, such as
253
carboxyl, hydroxyl and amine groups, are known to be influenced by electric field,40 in particular
254
hydroxyl and amide groups that have higher electric dipole moments and are more readily
255
polarized. In addition, charge distribution with foulant (humic acid) molecules was induced by
256
the applied electric field, resulting in more charges being concentrated at both ends of the
257
molecules along electric field direction. These polarized functional groups rendered humic acid
258
more inclined to attach to the membrane surface at higher electric fields due to the stronger
259
electrostatic force. As a result, cake layers with higher polarity were formed, exhibiting high
260
affinity to water molecules and subsequently improving water permeability. An illustration of the
261
proposed mechanism for the impact of electric field on fouling is summarized in Figure 8.
262
FIGURE 8
263
ECMR Fouling Mitigation Mechanisms and Implications for System Operation
264
and Design. Particle size, which performed as a key factor in reducing membrane fouling in
265
ECMR, was controlled by the current density and solution pH. Particles with sizes larger than the
266
membrane pore size reduced membrane pore blocking and facilitated the formation of a cake
267
layer that served as a protective layer. Meanwhile, a loose and hydrophilic cake layer was
268
formed in ECMR, due to oriented polarization of foulants under the electric field. Charged
269
foulants on the membrane surface were aligned in accordance with the direction of the applied
270
electric field. The increased cake layer polarity induced by both coagulation and electric field
271
further improved the affinity of the membranes to water. Therefore, the combined effect of 9 ACS Paragon Plus Environment
Page 11 of 23
Environmental Science & Technology
272
coagulation and electric field in ECMR improved the fouling resistance of UF the membrane and
273
resulted in a higher water flux.
274
ECMR not only improves removal efficiency of organic matter but also greatly mitigates
275
membrane fouling. ECMR performs better at high current densities and under weakly acidic pH
276
conditions. It is also feasible to further minimize membrane pore blocking by starting the
277
membrane filtration process after the floc size becomes larger than the membrane pore size.
278
Furthermore, increasing the applied voltage can result in a more hydrophilic cake layer. The
279
above operation conditions favor effective mitigation of membrane fouling in practice.
280
Water production per unit volume of reactor can be increased with the design of multiple
281
electrodes and membrane modules in the ECMR. The energy consumption per unit water
282
production for ECMR at 2 A/m2 was comparable to that of EC-UF. When applying current
283
densities of 10 A/m2 and 20 A/m2, ECMR reduces energy consumption by 6.4% and 1.3%,
284
respectively, compared to EC-UF (Supporting information Table S2 and Equation S8). Therefore,
285
energy savings could be achieved by changing the water treatment system configuration from
286
EC-UF to ECMR. In addition, the land use of ECMR will be reduced due to a more compact
287
reactor design.
288 289
ASSOCIATED CONTENT
290
Supporting information available: molecular weight distribution of humic acid (Figure S1);
291
particle size distribution of kaolinite (Figure S2); ATR-FTIR spectra of humic acid and kaolinite
292
(Figure S3); supplementary scheme for the design of ECMR (Figure S4); normalized water flux
293
decline curves at different electric conductivity (Figure S5); calculation of particle size for light
294
scattering measurements; fitted parameters for pore blocking resistance-limited model (Table
295
S1); normalized water flux decline curves at different current densities in EC-UF (Figure S6);
296
influence of ionic strength on EC (Figure S7); energy dispersion spectrum analysis (Figure S8);
297
pore size analysis (Figure S9); parameters for energy consumption calculation (Table S2). This
298
material is available free of charge via the internet at http://pubs.acs.org.
299 300
AUTHOR INFORMATION 10 ACS Paragon Plus Environment
Environmental Science & Technology
301
Corresponding Author
302
*Chengzhi Hu, Phone: +86-10-62849160; fax: +86-10-62849160; email:
[email protected].
303
Author Contributions
304
The manuscript was written through contributions of all authors. All authors have given approval
305
to the final version of the manuscript.
306 307
ACKNOWLEDGMENT
308
The authors are grateful for financial support from the National Natural Science Foundation of
309
China (No. 51678556 and 51438011) and the Major Science and Technology Program for Water
310
Pollution Control and Treatment (2015ZX07402003-3).
311
11 ACS Paragon Plus Environment
Page 12 of 23
Page 13 of 23
Environmental Science & Technology
312
REFERENCES
313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357
1. Shannon, M. A.; Bohn, P. W.; Elimelech, M.; Georgiadis, J. G.; Marinas, B. J.; Mayes, A. M., Science and technology for water purification in the coming decades. Nature 2008, 452, (7185), 301-310. 2. Van der Bruggen, B.; Everaert, K.; Wilms, D.; Vandecasteele, C., Application of nanofiltration for removal of pesticides, nitrate and hardness from ground water: rejection properties and economic evaluation. J. Membr. Sci. 2001, 193, (2), 239-248. 3. Zhang, Q.; Vecitis, C. D., Conductive CNT-PVDF membrane for capacitive organic fouling reduction. J. Membr. Sci. 2014, 459, 143-156. 4. Saravia, F.; Zwiener, C.; Frimmel, F. H., Interactions between membrane surface, dissolved organic substances and ions in submerged membrane filtration. Desalination 2006, 192, (1-3), 280-287. 5. Jermann, D.; Pronk, W.; Meylan, S.; Boller, M., Interplay of different NOM fouling mechanisms during ultrafiltration for drinking water production. Water Res. 2007, 41, (8), 17131722. 6. Peiris, R. H.; Halle, C.; Budman, H.; Moresoli, C.; Peldszus, S.; Huck, P. M.; Legge, R. L., Idendifying fouling events in a membrane-based drinking water treatment process using principal component analysis of fluorescence excitation-emission matrices. Water Res. 2010, 44, (1), 185-194. 7. Chung, C. M.; Tobino, T.; Cho, K.; Yamamoto, K., Alleviation of membrane fouling in a submerged membrane bioreactor with electrochemical oxidation mediated by in-situ free chlorine generation. Water Res. 2016, 96, 52-61. 8. Bagga, A.; Chellam, S.; Clifford, D. A., Evaluation of iron chemical coagulation and electrocoagulation pretreatment for surface water microfiltration. J. Membr. Sci. 2008, 309, (1-2), 82-93. 9. Gamage, N. P.; Chellam, S., Aluminum electrocoagulation pretreatment reduces fouling during surface water microfiltration. J. Membr. Sci. 2011, 379, (1-2), 97-105. 10. Ben Sasson, M.; Adin, A., Fouling mechanisms and energy appraisal in microfiltration pretreated by aluminum-based electroflocculation. J. Membr. Sci. 2010, 352, (1-2), 86-94. 11. Hua, L.-C.; Huang, C.; Su, Y.-C.; Tran-Ngoc-Phu, N.; Chen, P.-C., Effects of electrocoagulation on fouling mitigation and sludge characteristics in a coagulation-assisted membrane bioreactor. J. Membr. Sci. 2015, 495, 29-36. 12. Huang, H.; Schwab, K.; Jacangelo, J. G., Pretreatment for Low Pressure Membranes in Water Treatment: A Review. Environ. Sci. Technol. 2009, 43, (9), 3011-3019. 13. Chellam, S.; Sari, M. A., Aluminum electrocoagulation as pretreatment during microfiltration of surface water containing NOM: A review of fouling, NOM, DBP, and virus control. J. Hazard. Mater. 2016, 304, 490-501. 14. Ibeid, S.; Elektorowicz, M.; Oleszkiewicz, J. A., Electro-conditioning of activated sludge in a membrane electro-bioreactor for improved dewatering and reduced membrane fouling. J. Membr. Sci. 2015, 494, 136-142. 15. Sari, M. A.; Chellam, S., Surface water nanofiltration incorporating (electro) coagulationmicrofiltration pretreatment: Fouling control and membrane characterization. J. Membr. Sci. 2013, 437, 249-256. 16. Bani-Melhem, K.; Elektorowicz, M., Development of a Novel Submerged Membrane Electro-Bioreactor (SMEBR): Performance for Fouling Reduction. Environ. Sci. Technol. 2010, 44, (9), 3298-3304. 12 ACS Paragon Plus Environment
Environmental Science & Technology
358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403
Page 14 of 23
17. Liu, L.; Liu, J.; Gao, B.; Yang, F.; Chellam, S., Fouling reductions in a membrane bioreactor using an intermittent electric field and cathodic membrane modified by vapor phase polymerized pyrrole. J. Membr. Sci. 2012, 394, 202-208. 18. Ronen, A.; Duan, W.; Wheeldon, I.; Walker, S.; Jassby, D., Microbial Attachment Inhibition through Low-Voltage Electrochemical Reactions on Electrically Conducting Membranes. Environ. Sci. Technol. 2015, 49, (21), 12741-12750. 19. Chen, J.-P.; Yang, C.-Z.; Zhou, J.-H.; Wang, X.-Y., Study of the influence of the electric field on membrane flux of a new type of membrane bioreactor. Chem. Eng. J. 2007, 128, (2-3), 177-180. 20. Fan, X.; Zhao, H.; Quan, X.; Liu, Y.; Chen, S., Nanocarbon-based membrane filtration integrated with electric field driving for effective membrane fouling mitigation. Water Res. 2016, 88, 285-292. 21. Tsai, Y.-T.; Weng, Y.-H.; Lin, A. Y.-C.; Li, K.-C., Electro-microfiltration treatment of water containing natural organic matter and inorganic particles. Desalination 2011, 267, (2-3), 133-138. 22. Chen, X.; Deng, H., Removal of humic acids from water by hybrid titanium-based electrocoagulation with ultrafiltration membrane processes. Desalination 2012, 300, 51-57. 23. Nghiem, L. D.; Schafer, A. I.; Elimelech, M., Pharmaceutical retention mechanisms by nanofiltration membranes. Environ. Sci. Technol. 2005, 39, (19), 7698-7705. 24. Zhu, B. T.; Clifford, D. A.; Chellam, S., Comparison of electrocoagulation and chemical coagulation pretreatment for enhanced virus removal using microfiltration membranes. Water Res. 2005, 39, (13), 3098-3108. 25. Tanneru, C. T.; Rimer, J. D.; Chellam, S., Sweep Flocculation and Adsorption of Viruses on Aluminum Flocs during Electrochemical Treatment Prior to Surface Water Microfiltration. Environ. Sci. Technol. 2013, 47, (9), 4612-4618. 26. Chen, Y.; Dong, B. Z.; Gao, N. Y.; Fan, J. C., Effect of coagulation pretreatment on fouling of an ultrafiltration membrane. Desalination 2007, 204, (1-3), 181-188. 27. Yu, W.; Hu, C.; Liu, H.; Qu, J., Effect of dosage strategy on Al-humic flocs growth and re-growth. Colloids and Surfaces a-Physicochemical and Engineering Aspects 2012, 404, 106111. 28. Ho, C. C.; Zydney, A. L., A combined pore blockage and cake filtration model for protein fouling during microfiltration. J. Colloid Interface Sci. 2000, 232, (2), 389-399. 29. Yuan, W.; Kocic, A.; Zydney, A. L., Analysis of humic acid fouling during microfiltration using a pore blockage-cake filtration model. J. Membr. Sci. 2002, 198, (1), 51-62. 30. Lee, S.; Cho, J. W.; Elimelech, M., Combined influence of natural organic matter (NOM) and colloidal particles on nanofiltration membrane fouling. J. Membr. Sci. 2005, 262, (1-2), 2741. 31. Xiao, F.; Xiao, P.; Zhang, W. J.; Wang, D. S., Identification of key factors affecting the organic fouling on low-pressure ultrafiltration membranes. J. Membr. Sci. 2013, 447, 144-152. 32. Yuan, W.; Zydney, A. L., Humic acid fouling during microfiltration. J. Membr. Sci. 1999, 157, (1), 1-12. 33. Howe, K. J.; Marwah, A.; Chiu, K.-P.; Adham, S. S., Effect of coagulation on the size of MF and UF membrane foulants. Environ. Sci. Technol. 2006, 40, (24), 7908-7913. 34. Xu, Y.; Chen, T.; Cui, F.; Shi, W., Effect of reused alum-humic-flocs on coagulation performance and floc characteristics formed by aluminum salt coagulants in humic-acid water. Chem. Eng. J. 2016, 287, 225-232. 13 ACS Paragon Plus Environment
Page 15 of 23
404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432
Environmental Science & Technology
35. Ching, H. W.; Elimelech, M.; Hering, J. G., Dynamics of Coagulation of Clay Particles with Aluminum Sulfate. J. Environ. Eng. 1994, 120, (1), 169-189. 36. Tremblay, L.; Alaoui, G.; Leger, M. N., Characterization of Aquatic Particles by Direct FTIR Analysis of Filters and Quantification of Elemental and Molecular Compositions. Environ. Sci. Technol. 2011, 45, (22), 9671-9679. 37. Cao, B.; Gao, B.; Liu, X.; Wang, M.; Yang, Z.; Yue, Q., The impact of pH on floc structure characteristic of polyferric chloride in a low DOC and high alkalinity surface water treatment. Water Res. 2011, 45, (18), 6181-6188. 38. Hu, C.; Sun, J.; Wang, S.; Liu, R.; Liu, H.; Qu, J., Enhanced efficiency in HA removal by electrocoagulation through optimizing flocs properties: Role of current density and pH. Sep. Purif. Technol. 2017, 175, 248-254. 39. Chen, M.-Y.; Lee, D.-J.; Yang, Z.; Peng, X. F.; Lai, J. Y., Fluorecent staining for study of extracellular polymeric substances in membrane biofouling layers. Environ. Sci. Technol. 2006, 40, (21), 6642-6646. 40. de Menezes, V. M.; Mota, R.; Zanella, I.; Fagan, S. B., Pristine and functionalized capped carbon nanotubes under electric fields. Phys. Status Solidi B 2014, 251, (3), 649-654. 41. Li, H.; Hu, T.; Zhang, R.; Liu, J.; Hou, W., Preparation of solid-state Z-scheme Bi2MoO6/MO (M=Cu, Co3/4, or Ni) heterojunctions with internal electric field-improved performance in photocatalysis. Appl. Catal. B: Environ. 2016, 188, 313-323. 42. Peter-Varbanets, M.; Margot, J.; Traber, J.; Pronk, W., Mechanisms of membrane fouling during ultra-low pressure ultrafiltration. J. Membr. Sci. 2011, 377, (1-2), 42-53. 43. Litvin, V. A.; Minaev, B. F., Spectroscopy study of silver nanoparticles fabrication using synthetic humic substances and their antimicrobial activity. Spectrochim. Acta A 2013, 108, 115-122. 44. Hatch, C. D.; Gierlus, K. M.; Zahardis, J.; Schuttlefield, J.; Grassian, V. H., Water uptake of humic and fulvic acid: measurements and modelling using single parameter Kohler theory. Environ. Chem. 2009, 6, (5), 380-388. 45. Jarusutthirak, C.; Amy, G., Role of soluble microbial products (SMP) in membrane fouling and flux decline. Environ. Sci. Technol. 2006, 40, (3), 969-974.
433 434
14 ACS Paragon Plus Environment
Environmental Science & Technology
Page 16 of 23
435 436
Figure 1. Schemes for (a) the design of ECMR system: 1.4 L of synthetic feed water was recycled by two
437
peristaltic pumps (36 mL/min) in order to generate cross-flow and keep a constant water level in the
438
ECMR system. The membrane module was placed between two aluminum electrodes parallel to the water
439
flow, with the distance between the two electrodes fixed at 2.5 cm. A pressure sensor was employed to
440
monitor the transmembrane pressure, which was maintained at 30 kPa by a peristaltic pump. Permeate
441
water was generated via peristaltic pump from UF membrane module and weighted by a digital balance,
442
which connected to a computer. (b) Hollow fiber membrane module (one eighth was cut off in order to
443
exhibit the inside structure of the membrane module). Water passed through membranes from the fiber
444
outside (brown arrow), flowed inside the membranes (purple arrow) and was collected by a small tube on
445
top of the membrane module (blue arrow).
446
15 ACS Paragon Plus Environment
Page 17 of 23
Environmental Science & Technology
(a)
UF EC EC-UF ECMR
1.0 0.8
C/C0
0.6 0.4 0.2 0.0 0
Normalized Water Flux
1.1
10
20
30
40
50
(b)
60
ECMR EC-UF UF
1.0 0.9 0.8 0.7 0.6 0.5 0
447
2
4
6
8
10
12
14
Time (min)
448
Figure 2. (a) Removal rate of humic acid (as measured by UV254) by UF, EC, EC-UF, and ECMR.
449
Removal rates were obtained from three independent fouling experiments. (b) Final relative water flux
450
(J/J0) of ECMR and EC-UF at 10 A/m2 and UF alone. Feed water was composed of sodium chloride (50
451
mM), sodium bicarbonate (0.5 mM), humic acid (5 mg/L DOC), and kaolinite (50 mg/L). Initial solution
452
pH was 7.0 and temperature was kept at 25 °C.
453
16 ACS Paragon Plus Environment
Environmental Science & Technology
Page 18 of 23
454 455
Figure 3. (a) Normalized water flux decline curves at different current densities in ECMR; (b) particle
456
size evolution with time at different current densities at initial pH 7. Feed solution composition is
457
described in the caption of Figure 2.
458
17 ACS Paragon Plus Environment
Page 19 of 23
Environmental Science & Technology
459 460
Figure 4. (a) Normalized water flux decline curves under different initial solution pH; (b) particle size
461
evolution with time under different initial solution pH at 10 A/m2. Feed solution composition is described
462
in the caption of Figure 2.
463
18 ACS Paragon Plus Environment
Environmental Science & Technology
Page 20 of 23
464 465
Figure 5. Normalized water flux decline curves under different initial electric field strengths. The
466
corresponding initial electric conductivities were 500, 1000, and 2000 µS/cm for 2.00 V/cm, 1.00 V/cm,
467
and 0.50 V/cm, respectively; current density was 10 A/m at pH 7.0. Feed solution composition is
468
described in the caption of Figure 2.
2
469
19 ACS Paragon Plus Environment
Page 21 of 23
Environmental Science & Technology
470 471
Figure 6. Scanning electron microscopy (SEM) images of fouled hollow fiber membrane surface under
472
electric fields of (a) 0.5 V/cm, (b) 1 V/cm, and (c) 2 V/cm and cross-sections under electric fields of (d)
473
0.5 V/cm, (e) 1 V/cm, and (f) 2 V/cm, respectively. The corresponding initial conductivities were 500,
474
1000, and 2000 µS/cm, for 2 V/cm, 1 V/cm, and 0.5 V/cm, respectively; current density was 10 A/m2 at
475
pH 7.0 and experiment time was 30 min. Feed solution composition is described in the caption of Figure
476
2.
477
20 ACS Paragon Plus Environment
Environmental Science & Technology
Page 22 of 23
478 479
Figure 7. (a) Contact angle and (b) attenuated total reflectance Fourier transform infrared spectroscopy
480
(ATR-FTIR) spectra of fouled membranes at different initial electric fields. The corresponding initial
481
conductivities were 500, 500, 1000, and 2000 µS/cm, for 0 V/cm, 2 V/cm, 1 V/cm, and 0.5 V/cm,
482
respectively; the current density was 10 A/m2 at pH 7.0. Contact angle measurements were repeated three
483
times.
484 21 ACS Paragon Plus Environment
Page 23 of 23
Environmental Science & Technology
485 486
Figure 8. Schematic description of the proposed mechanisms for membrane fouling mitigation in ECMR.
22 ACS Paragon Plus Environment