"Toll
Gate"
for corrosive
flows
The Daniel Simplex Honed Flow Section In laboratories and plant installations where flow measure ment accuracy is a critical factor, you'll find the Daniel Simplex Honed Flow Section right at home, taking "toll" of corrosive fluids. This precise measurement tool is furnished in carbon steel or 304 stainless steel to withstand severe attack by cor rosive agents. Each tube is carefully honed to exact inside diameters and finished to a smooth, 45-60 micro-inch roughness. The popular Simplex orifice plate holder provides for fast, simple platechanging. It may be used with any type of differential recorder, and handles pressures from 0 to 1440 p.s.i. (Gage) c.w.p., or 600 lbs. A.S.A. in sizes from VA" to 6". The unit is shipped complete with one stainless steel orifice plate bored to your specifications. Send today for your copy of our catalog Section " O " for full details on Daniel Honed Flow Sections.
DANIEL ORIFICE
FITTING
COMPANY
I N C O R P O R A T E D
Houston, Texas P. 0. Box 19097 Homestead 5-3451
Los Angeles, California 3352 Union Pacific Ave. ANgelus 9-9206 M2
Circle No. 219 on Readers' Service Card
PHOTOVOLT
A complete line of pH meters, incorporating permanently frictionless taut-suspension indicating meters, modern electronic tubes and circuits. Simple in operation and maintenance; featuring sealed amplifier plug-in units.
Electronic pH METERS High Precision pH Meter Model 110
Two-way pH Meter Model 85
Single range 0-14, scale length 7", readable to 0.02 pH unit. Temperature control 0-100° C, voltage selector for 80-260 volts. Available — carrying cover and baseboard for bottles, beakers. Write for Bulletin #105
Single range 0-14, scale length 3", readable to 0.05 pH Unit. Available — compact battery pack for field use ($38.00 addtl.). Fully stabilized, simple, usable with all types of electrodes. Write for Bulletin #195
$235
$135
Standard Laboratory pH Meter Model 115
Portable pH Meter Model 125 Single range 0-14, scale length Wz", readable to 0.03 pH unit. Only 3 batteries, standard radio type, 2,000 hours of service. Available — carrying frame for instrument, beakers, bottles. Write for Bulletin #118
• Single range 0-14, scale length 4", readable to 0.05 pH unit. • Temperature control 20-100° C, available with carrying case. • Additional millivolt scale for redox measurements and titrations. Write for Bulletin #225
$175
$195
PHOTOVOLT
Tester Model 25 for Checking and Adjusting pH Meters A compact, inexpensive instrument without batteries; for checking performance of PH0T0V0LT and other pH meters. Requires neither electrodes nor buffers. Write for Bulletin #138 $ 6 8