PIERCE CHEMICAL COMPANY

Rockford, 111. 61105. 815-968-0747. 503. Ampuls for Water ... P.O. Box 117 Rockford, Illinois 61105 U.S.A.. PHONE 815/96B-Q747. TWX 810-631-3419...
2 downloads 0 Views 220KB Size
NEW CHEMICALS

Cabinet of a thousand faces.

Recorder Inks

A new fast-drying, nonclogging recorder ink is available in blue or red. The new ink is completely dry by the time a pen has traveled 1 / 2 in. (at 4 in./hr chart speed). It also can remain in the recorder as long as 30 days and the pens will operate as well as usual. The inks are priced at $7.50 per package of three 1-oz bottles. Fisher Scientific Co., 312 Fisher Bldg., Pittsburgh, Pa. 15219. 412-391-1330 501 Reagent for Polynuclear Compounds and Carcinogens

2,4,7-Trmitro-9-fluorenone ( TNF ) forms complexes with aromatic polynuclear hydrocarbons and their derivatives which are bright colored, melt sharply with decomposition, and are easily recovered. These complexes are analytically useful for the identification of even trace amounts of these compounds. The melting points and physical characteristics of a large number of TNF complexes have been tabulated. Polysciences, Inc., Warrington, Pa. 18976. 215-343-6484 502

Switch doors to drawers, to shelves ... in the twist of a screwdriver Blickman's patented Conflex laboratory furniture adapts to changing lab needs in minutes. Without special tools. Nearly 1,000 door and drawer combinations. Mix and match doors and drawers . . . turn 3Vi "-deep drawers into 7Vi "-deep drawers . . . adjust shelves in 1/2 " increments. Specify Conflex furniture .. . the laboratory furniture that changes with the times! Send the coupon for complete details and specs.

n

Rush free Conflex Laboratory Furniture catalog Have a lab specialist phone us

Name/Title Institution Address City/State/Zip

A TYPICAL total time 6 minutes

FROM Place 10 mg glucose in vial.

RAW S A M P L E TO GAS C H R O M A T O G R A P H Y

Silylation makes possible the gas chromatographic analysis of thousands of compounds not formerly amenable t o GC and eases the problems of the GC analysis of many other polar substances. Most silylation techniques are rapid and easy, transforming many intractable substances into volatile and thermally stable trimethylsilyl ethers that give symmetrical GC peaks. We have just published a 60 page "Handbook of S i l y l a t i o n " that is a gold mine of information on silylation and other special techniques of gas phase analysis. It contains a wealth of practical suggestions, methods, references, data on reagents and accessories. "Handbook of S i l y l a t i o n " is yours for the asking; drop us a note—today.

Ampuls for Water Analysis

A series of ampuls sealed under vacuum and containing color-forming reagents can be used for quick, accurate water analysis. The Quantets, cigarette-sized ampuls, come in various packs to measure specific ingredients; dissolved oxygen, peroxide oxygen, ferric and ferrous iron, total iron, and chlorine. When the ampul tip is broken under the water to be tested, a measured amount of the sample is drawn in and mixed with the reagent. The resulting liquid changes color and can then be compared with a color chart supplied in each ampul pack. CHEMetrics, Inc., P.O. Box 515, Nitro, W. Va, 25143 504

D

Circle No. 18 on Readers' Service Card

Instant Aerosol

A new laboratory tool, Quixpray, makes an instant aerosol of any sprayable liquid. This provides a fast, convenient method for applying reagents and indicators for thin layer and paper chromatography; especially good for reagents that must be mixed for immediate use. The unit is available in kit. form containing complete spray unit, extra jars, and propellant refills (the propellant is an inert halocarbon). Pierce Chemical Co., P.O. Box 117, Rockford, 111. 61105. 815-968-0747 503

S. Blickman, Inc. 9608 Gregory Ave. Weehawken, N.J. 07087

PIERCE CHEMICAL COMPANY P.O. Box 117 Rockford, Illinois 61105 U.S.A. PHONE 815/96B-Q747

Shake

t o dissolve.

TWX 8 1 0 - 6 3 1 - 3 4 1 9 .

A l l o w to stand 5 minutes; w i t h d r a w sample for injection.

Inject sample into chromatograph.

Circle No. 12 on Readers' Service Card ANALYTICAL CHEMISTRY, VOL. 4 2 , NO. 9, AUGUST 1 9 7 0

·

75 A