Polyurethane Foam (PUF) Disk Samplers for Measuring Trace Metals in Ambient Air Eftade Emine Gaga, Tom Harner, Ewa Dabek-Zlotorzynska, Valbona Celo, Greg J. Evans, Cheol-Heon Jeong, Sabina Halappanavar, Narumol Jariyasopit, and Yushan Su Environ. Sci. Technol. Lett., Just Accepted Manuscript • DOI: 10.1021/acs.estlett.9b00420 • Publication Date (Web): 15 Aug 2019 Downloaded from pubs.acs.org on August 20, 2019
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 16
1 2
Environmental Science & Technology Letters
Polyurethane Foam (PUF) Disk Samplers for Measuring Trace Metals in Ambient Air
3 4 5
Eftade O.Gaga†∥*, Tom Harner†*, Ewa Dabek-Zlotorzynska♣, Valbona Celo♣, Greg Evans, Cheol-Heon Jeong, Sabina Halappanavar§, Narumol Jariyasopit†ψ, Yushan Su
6 7 8
†Air Quality Processes Research Section, Environment and Climate Change Canada, Toronto, Canada M3H 5T4
9
♣ Air Quality Research Division, Environment and Climate Change Canada, Ottawa, ON, Canada K1V 1H2
*
[email protected],
[email protected] 10
∥ Environmental Engineering Department, Eskişehir Technical University, Eskişehir, Turkey, 26555
11
Department of Chemical Engineering & Applied Chemistry, University of Toronto, Canada
12
§ Mechanistic Studies Division, ERHSD, HECSB, Health Canada, Ottawa, Canada K1A 0K9
13 14
ψSiriraj Metabolomics and Phenomics Center, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok,
15
Ontario Ministry of the Environment, Conservation and Parks, Toronto, Ontario, Canada M9P 3V6
M5S3E5
Thailand, 10700
16 17 18
Abstract
19
A new method is presented for measuring atmospheric concentrations of trace metals in
20
airborne particulate matter using polyurethane foam (PUF) disk passive air samplers (PUF-
21
PAS) and passive dry deposition air samplers (PAS-DD), which until now have mainly been
22
applied to organic pollutants in air. A field calibration study was conducted at one of the sites
23
where measurements of trace metals were available using conventional methods. Uptake
24
profiles of PUF-PAS and PAS-DD samplers were linear over the full 56 days that the samplers
25
were deployed. The results confirm the ability of both passive sampler types to provide time-
26
integrated measurements of airborne trace metals. For the PUF-PAS sampler, the derived
27
sampling rates (R) were generally in the range of default values derived for organic pollutants
28
(i.e. 4 ± 2 m3/day). For the PAS-DD sampler, the collection of the larger depositing particles
29
resulted in elevated effective sampling rates, which were up to ~4 times higher than for PUF-
30
PAS. Sampling rates for PAS-DD were more variable compared to PUF-PAS, probably due to
31
variability of the association of various trace metals with larger particles. Results from the PAS-
32
DD sampler were also converted to effective dry deposition fluxes and were as high as 6700 1 ACS Paragon Plus Environment
Environmental Science & Technology Letters
33
µg/m2/day for iron (Fe). This study provides a proof concept and methodology for the
34
application of PUF disk-based samplers as a versatile and cost-effective tool for studying trace
35
metals, in addition to organics, in ambient air. The method was used to assess concentrations
36
of 25 trace metals in ambient using PUF-PAS samples deployed across 6 urban sites in the
37
Greater Toronto Area, impacted by different emission sources to air. Highest trace metal
38
concentrations were measured at sites impacted by traffic.
39
Keywords: Polyurethane Foam (PUF) disk sampler, trace metals, passive sampling, urban air
40
pollution
41 42
Introduction
43
Due to the toxicity and health effects associated with exposure and inhalation of atmospheric
44
particulate matter (PM) there is an incentive for developing simple passive sampling tools that
45
measure PM and its related constituents in ambient air. The atmospheric deposition of PM is
46
also important as a delivery pathway to terrestrial surfaces (e.g. soils, vegetation etc) and
47
ecosystem exposure. Particle deposition is a function of particle size with larger particles
48
deposited closer to the source. 1,2,3,4
49
Passive samplers have been used for monitoring organic and inorganic pollutants in various
50
indoor and outdoor environments.5–10 Compared to active samplers, passive samplers are less
51
expensive, require less maintenance and infrastructure/electricity to operate and are easy to
52
use, which make them ideally-suited for spatial investigations of air pollutants.11,12 PUF disk
53
passive samplers have been shown to capture both gas-phase and particle-phase persistent
54
organic pollutants (POPs) in ambient air with an equivalent air sampling rate of about 4
55
m3/day. The porous nature of PUF helps to ensure that particles are entrained in the PUF
56
matrix once deposited and therefore less susceptible to resuspension to air. 7,13,14,15,16,17
57 58
We hypothesized that PM bound trace metals, which are important components of PM, can
59
also be effectively collected by PUF passive samplers. Polyurethane foam disk passive air
60
samplers (PUF-PAS) have been widely used to measure air concentrations of POPs and other
61
emerging organic chemicals at the local, regional and even global scale. 5,7,18,6 Recently, a new
62
program was initiated in Toronto, Canada called ATOUSSA (Assessing Toxicity of Organics in
63
Urban Source Sectors for Air) which targets polycyclic aromatic compounds (PACs) and other 2 ACS Paragon Plus Environment
Page 2 of 16
Page 3 of 16
Environmental Science & Technology Letters
64
POPs. The overarching objective of the ATOUSSA project is to link levels of these chemical
65
constituents in ambient air to potential adverse human health impacts. As part of a pilot study
66
under the ATOUSSA project PUF-PAS samplers were co-deployed at sampling locations over
67
one sampling period to assess trace metals in air.
68 69
At the same time, a calibration study was carried out at one of the ATOUSSA sites where trace
70
metals were being measured using conventional methods. The field uptake study evaluated
71
the performance of the PUF-PAS sampler as well as a second sampler type – the PAS-DD
72
(Passive Dry Deposition). Whereas the PUF=PAS sampler provides a measure of contaminants
73
present in ambient air, including those that can be inhaled, the PAS-DD sampler targets the
74
components that deposit from air to terrestrial surfaces, where they can be taken up by
75
ecosystems. In summary, the objectives of this study include,
76
(i)
polyurethane foam disks.
77 78
(ii)
To characterize and compare the uptake profiles of PUF-PAS and PAS-DD. samplers for measuring trace metals and deposition from ambient air.
79 80
To develop sampling methods for measuring trace metals collected by
(iii)
To employ this method to assess the spatial distribution of trace metals in ambient air.
81 82 83
Materials and Methods
84
Sampling
85
For the uptake study, two different samplers, PUF-PAS and PAS-DD were co-deployed in
86
duplicate at the Downsview site (DV, 43o46’48.03”N, 79o28’3.81”W) from March 29 to May
87
24, 2017 as shown in Figure 1 and Figure S1. Samplers were deployed approximately 2 m
88
above the ground. PUF disks (14 cm diameter × 1.35 cm thick; surface area 365 cm2, mass 4.40
89
g, volume 207 cm2, Tisch Environmental, Cleves, OH, USA) were precleaned prior to
90
deployment. Parallel samplers were deployed for 1, 2, 4, 6 and 8 weeks. During field sampling,
91
PUF disks were housed horizontally inside precleaned stainless steel chambers (PUF-PAS
92
sampler, Tisch Environmental, TE-200-PAS) and between the parallel plates of the PAS-DD
93
sampler (Tisch Environmental, TE-PAS-DD) (Figure 1). Field blanks (n=4) for both PUF-PAS and
94
PAS-DD were collected by exposing the sampling media for a few seconds to ambient air and
95
then storing and treating the same way as samples. 3 ACS Paragon Plus Environment
Environmental Science & Technology Letters
96
Double-bowl PUF disk samplers for trace metal determination were deployed during winter,
97
February to March 2017 (∼60 days), across 6 locations in Greater Toronto Area, at sampling
98
sites targeting organic pollutants as part of the ATOUSSA Project (Figure 2). The sampling
99
locations have different source characteristics as described in Table S1. All samples were
100
stored in pre-cleaned, solvent-rinsed glass jars following the GAPS network protocols.19
101
Sample Preparation, Analysis and QA/QC
102
As a first step, the homogeneity of the trace metals deposited onto the PUF disks was tested.
103
Subsamples of three PUF disks which were deployed for 2 months at the Downsview field site
104
were used for this purpose. The three disks were each cut into eight equal wedges using a
105
stainless steel blade that were used to obtain even smaller wedges (~0.1 g) for analysis.
106
Wedges from each disk were selected randomly for analysis including 3 wedges from disks 1
107
and 2 (SD1 and SD2 in Table S2) and 6 wedges from disk 3 (SD3). For the majority of the trace
108
metals (~80 %) the % RSD values were below 25 %. The higher RSD values were not associated
109
with detection limit issues and the data were not excluded from the analysis.
110 111
To assess blanks, experiments were first carried out on PUF disks that were precleaned using
112
long-standing methods that were developed for POPs analysis5. This revealed high blank
113
levels of trace metals and indicated that an additional cleaning step was required. Several
114
methods of precleaning the PUF disks were evaluated. The best method, which was applied in
115
this study, involved rinsing the PUF disk 3 times with fresh deionized (DI) water, followed by
116
ultrasonication in 1% HNO3 for 1.5 hours. The disks were then further rinsed several times
117
with DI water to remove acid residues, and dried under N2 gas. The success of the the acid
118
rinsing step on reducing blank levels is shown in Table S3. Sample to field blank ratios (S/B)
119
for the uptake study samples were calculated for each deployment step for both samplers and
120
results are shown in Table S4. The S/B ratios improved (increased) over time and were also
121
higher for PAS-DD samplers compared to PUF-PAS, due to higher loading rates for PAS-DD
122
compared to PUF-PAS. At the end of 8-weeks of deployment, S/B values were greater than 5
123
for most trace metals and greater than 100 for several of them. Low S/B values (i.e. close to
124
1), indicating blank contamination issues, were observed for Ni, Zn, Sr, and Mo.
125 126
Samples were analyzed for both water-soluble and acid-soluble trace metals. For acid-soluble 4 ACS Paragon Plus Environment
Page 4 of 16
Page 5 of 16
Environmental Science & Technology Letters
127
metals, PUF disk sub-samples (wedges) were processed by microwave assisted acid digestion
128
in preparation for analysis by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for
129
determination of total trace element concentrations. Briefly, 100 mg of PUF material was
130
accurately weighed directly into the 55-mL MARS Xpress digestion vials (CEM Corporation,
131
Matthews, NC) and pre-digested overnight at room temperature with a mixture of 7.5 mL of
132
40% (v/v) HNO3 and 2.5 mL of H2O2. Then, all samples were digested for 20 min at 200 C in
133
closed pressurized vessels in the microwave oven. The same digestion procedure was used
134
during the preliminary experiments for reducing blank trace element concentrations of PUF
135
disks. The extracted solutions were diluted to a final concentration of 4% (v/v) HNO3 prior to
136
ICP-MS analysis. For the water-soluble fraction, samples (0.25 g of PUF material) were
137
extracted with DI water (18 MΩ) in an ultrasonic bath for 30 min and then filtered using 0.22
138
µm syringe filters to remove insoluble materials. Samples were transferred to Nalgene bottles
139
and acidified with 1% (v/v) HNO3 prior to ICP-MS analysis of the water soluble fraction.
140
Analysis details and QA/QC parameters are given in Supporting Information (Text, S1,Table S5
141
to S7).
142 143
Results and Discussion
144
Uptake profiles for PUF-PAS and PAS-DD samplers
145
The uptake profiles of trace metals over time are shown in Figure S2 for both PAS-DD and PUF-
146
PAS samplers, which were deployed as duplicates, with raw data presented in Table S8.
147
Variability in duplicates is expressed as a ratio of sampler 1 to sampler 2 for each trace metal.
148
In the vast majority of samples, the variability was within a factor of 2 (i.e. ratio between 0.5
149
to 2) with only a few exceptions. This is consistent with variability reported for passive air
150
samplers measuring POPs in ambient air.18 Figure S2 indicates that most of the trace metals
151
exhibit near-linear uptake profiles with the amount of chemical collected on the samplers
152
proportional to the deployment time. This is consistent with previous calibration studies of
153
the samplers investigating particle-associated POPs. 20,21,22
154 155
The PAS-DD, which incorporates a PUF disk as the collection substrate positioned between
156
two open parallel flat plates that are shielded above, has a more “open” design compared to
157
PUF-PAS sampler (Figure 1). This allows larger particles (>10m) that are typically settling
158
through ambient air to flow between the parallel plates and be deposited onto the PUF disks 5 ACS Paragon Plus Environment
Environmental Science & Technology Letters
159
as they would onto other terrestrial surfaces 23; whereas the PUF-PAS, collects particles in a
160
similar size range (i.e.