Precise Three-Dimensional Scan-Free Multiple-Particle Tracking over

May 5, 2015 - Figure 4a shows an example raw-data frame (see also Supporting Information Movie 1) where three beads at different x,y,z positions can b...
0 downloads 11 Views 1MB Size
Subscriber access provided by CARLETON UNIVERSITY

Communication

Precise 3D scan-free multiple-particle tracking over large axial ranges with Tetrapod point spread functions Yoav Shechtman, Lucien E. Weiss, Adam S. Backer, Steffen J. Sahl, and W. E. Moerner Nano Lett., Just Accepted Manuscript • DOI: 10.1021/acs.nanolett.5b01396 • Publication Date (Web): 05 May 2015 Downloaded from http://pubs.acs.org on May 7, 2015

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Nano Letters is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Precise 3D scan-free multiple-particle tracking over large axial ranges with Tetrapod point spread functions Yoav Shechtman1, Lucien E. Weiss1, Adam S. Backer2, Steffen J. Sahl1┼, and W.E. Moerner1*

1

Department of Chemistry, Stanford University, 375 North-South Mall, Stanford, California 94305, USA

2

Institute for Computational and Mathematical Engineering, 475 Via Ortega, Stanford, California 94305, USA

ACS Paragon Plus Environment

1

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 23

ABSTRACT. We employ a novel framework for information-optimal microscopy to design a family of point spread functions (PSFs), the Tetrapod PSFs, which enable high-precision localization of nanoscale emitters in three dimensions (3D) over customizable axial (z) ranges of up to 20 µm, with a high numerical aperture objective lens. To illustrate, we perform flow profiling in a microfluidic channel, and show scan-free tracking of single quantum-dot-labeled phospholipid molecules on the surface of living, thick mammalian cells.

KEYWORDS. PSF engineering, single particle tracking, 3D imaging, single-molecule imaging, super-resolution microscopy, nanoscopy

ACS Paragon Plus Environment

2

Page 3 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Single-particle tracking (SPT), in which the trajectory of a moving individual molecular label, quantum dot, or nanoparticle is determined from a series of images, provides a valuable tool for a wide range of biological applications. Information inferred from the extracted particle trajectory can shed light on physical properties such as particle size, conformation, and the local environment

1-6

,because observing the motion of single particles directly unmasks nanoscale

behavior such as diffusion7, directed motion8, or anisotropy9; methods to enhance SPT would be valuable to many fields of study. SPT techniques are typically based on frame-by-frame localization of the particle. Namely, a series of time-sequential images (frames) is captured using a microscope, and each frame is analyzed to yield the current position of the particle. In some applications, the extracted positions are in two dimensions (2D), comprising lateral, or x,y coordinates. The noisy and pixelated 2D detector image of the particle is analyzed, e.g. by centroid or Gaussian fitting

10

, to yield the

estimated x,y coordinates of the particle. However, since most samples of interest are inherently three-dimensional (3D), the full physical behavior of the tracked object is in many cases only revealed by analyzing its 3D trajectory

1, 11

. The 3D trajectory of a moving particle can be

extracted in several ways. For example, a particle can be followed by using a feedback control loop based on moving a 3D piezo stage according to the reading of several detectors (e.g. photodiodes) 12, 13. While providing a very precise temporal and spatial trajectory this method is inherently limited to tracking a single particle. Alternatively, scanning methods, such as confocal microscopy

14

, can be implemented, in

which an illumination beam or the focal point of the microscope (or both) are scanned over time in three dimensions to yield a 3D image of the object. Naturally, any scanning method is limited

ACS Paragon Plus Environment

3

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 23

in its temporal resolution, since at a given time only a small region is being imaged. In order to realize fast, simultaneous tracking of several particles in 3D, a scan-free widefield approach is required. To efficiently encode information regarding the axial dimension (z), an optical system must be modified from that of a standard microscope. One possible modification is the “multi-plane” approach, based on simultaneous imaging of two or more planes in object space

15-17

. This

method requires simultaneous acquisition of multiple images, and is currently applicable to an axial range of ~4 µm 17. Importantly, it is possible to extract 3D position information from a single widefield 2D image, by modifying the microscope’s point spread function (PSF), namely, the image which is detected when observing a point source. Examples of PSF alterations which have been used for 3D tracking and imaging under biological conditions include astigmatism 18-20, the double-helix PSF 21-23

, the corkscrew PSF24, the bisected-pupil PSF25, and an Airy-beam-based PSF

26

, with

applicable z-ranges of ~1-2 µm for astigmatism and the bisected pupil PSF, and ~3 µm for the double-helix, corkscrew, and Airy PSFs. Recently, we developed a method to design information-optimal PSFs for 3D imaging

27

based on numerically maximizing the information content of the PSF. The resulting ‘SaddlePoint’ PSF exhibits superior 3D localization precision over existing PSFs. However, despite gradual improvements in PSF designs over recent years in terms of achievable precision, they are still quite limited in terms of their applicable z-range. Currently, the z-range of existing PSF designs is limited to ~3 µm, posing a major limitation for applications requiring ‘deep’ imaging. For example, the thickness of a mammalian cell can often be larger than 6 µm 28, and in the case

ACS Paragon Plus Environment

4

Page 5 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

of cells grown on cell feeder layers or in 3D cell cultures, which are becoming increasingly popular in the biological community – samples are obviously much thicker29. This means that, say, tracking the trajectory of a labeled protein over this axial range with high precision by using any existing PSF design cannot be accomplished without scanning or multi-plane imaging. Here, by utilizing the information maximization framework 27, we present PSFs which enable precise 3D localization over a depth range far larger than the applicable depth ranges of existing designs. By setting the optimization parameters to correspond to the desired depth range, we engineer specific PSFs yielding precise 3D localization optimized over that range. The resulting PSFs belong to a family we dub the Tetrapod PSFs, due to the tetrahedral shape they outline in 3D as a function of the emitter’s axial position. We demonstrate the utility of these exceptionally large-range PSFs for two experimental applications of wide interest: First, we optimize a Tetrapod PSF for a 20 µm z-range, and use it for flow-profiling in a microfluidic channel. We then use a Tetrapod PSF optimized for a 6 µm z-range under biological conditions; namely, we track single quantum-dot labeled lipid molecules diffusing in live mammalian cell membranes. The imaging system is a standard (inverted) microscope, augmented by a 4f optical processing system

30

, as shown in Fig. 1. The PSF of the microscope is modified from that of a standard

microscope by controlling the phase of the electromagnetic field in the Fourier plane of the 4f system. This can be done by placing a dielectric phase mask

31

or a liquid crystal-based spatial

light modulator (SLM) 6in the Fourier plane. For the experimental implementation here we use the SLM implementation31.

ACS Paragon Plus Environment

5

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 23

Figure 1. Experimental implementation of a 4f optical processing system. The PSF is modified by a phase mask (or spatial light modulator) placed in the Fourier plane.

With this imaging setup, the image formulation model is given by 32: , ; , , ∝ |   ,   ; , ,   ,   |,

(1)

where ,  is the image, or the intensity in the camera plane, of a point source located at position , , in sample space, relative to the focal plane and the optical axis (z). The field in the pupil plane, caused by the point source, is denoted by   ,   , and represents the 2D spatial Fourier transform with appropriate coordinate scaling. The complex function   ,   is the pattern imposed in the pupil plane by a mask or an SLM (see the Supporting Information for mathematical detail). Designing a PSF which enables precise 3D localization over a large z-range, under highbackground conditions (due to out-of-focus fluorescence or sample autofluorescence), is a challenging task. Consider the demands for such a PSF: On one hand, the microscope optics must concentrate the light into a relatively small region throughout the applicable z-range in order to overcome background noise. On the other hand, the PSF must contain high Fisher information, i.e., features which change sufficiently quickly as a function of z, such that its shape

ACS Paragon Plus Environment

6

Page 7 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

encodes the z position of the emitter with high “recognizability” or “z-distinctness”, which then translates into high statistical localization precision when localizing under noisy conditions. Fortunately, the theoretical precision of a given PSF can be quantified by the Cramer Rao Lower Bound (CRLB) 15, 33-35. The CRLB is a mathematical quantity indicative of the sensitivity of a measurement to its underlying parameters 36. More specifically, the CRLB corresponds to the lowest possible variance in estimating these parameters with an unbiased estimator. In our case, the measurement is a noisy, pixelated manifestation of the PSF (the 2D image), and the underlying parameters are the 3D coordinates of the emitter, as well as its brightness expressed as total signal photons, and a background level. Therefore, the challenge of designing an optimal PSF can be treated as an optimization problem, with the objective function being the CRLB, as we have recently demonstrated

27

.

Indeed, our approach to PSF design is purely algorithmic, and works as follows: Given the system parameters, such as magnification, numerical aperture, background and signal levels, and a (Poisson) noise model, we build a numerical imaging model, based on Eq. 1. We then use this model to solve the optimization problem of finding the Fourier phase pattern   ,   which would yield the PSF with the lowest theoretical localization variance (equivalently – the lowest CRLB). The CRLB is related to the Fisher information matrix – more specifically, it is the inverse of the Fisher information

36

. Practically, therefore, the objective function being

minimized is the mean trace of the Fisher information matrix (corresponding to mean x,y,z CRLB) over a finite set of N unique z positions in a defined z-range. That is, we wish to solve the following minimization problem:  : . . . :   , ′

!

*+ ∑! -. #$% &'() ,

(2)

ACS Paragon Plus Environment

7

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 23

Where in Eq. (2) above, '() is the 3-by-3 Fisher information matrix associated with the x-y-z localization precision associated with the PSF at the j’th z position. This optimization can be performed over a subset of functions, e.g. Zernike modes 37. See the Supporting Information and 27

for further details. Running our optimization routine with different specified z-ranges yields different phase

masks (and corresponding PSFs). However, the resulting PSFs share very strong common characteristics. Namely, for any tested z-range (from 2-20 µm), these PSFs consist, broadly, of two distinct lobes, with growing transverse distance between them as the emitter departs from the microscope’s focal plane. The orientation of the two lobes of the PSF is rotated by 90° above and below the focal plane. This family of PSFs is therefore dubbed the Tetrapod PSFs, due to the 3D tetrahedral shape they trace out as the point source is moved in z (the axial direction). Two example Tetrapod masks, along with the corresponding PSFs (calculated and experimentally measured), optimized for a 6 µm range and a 20 µm range, are shown in Fig. 2. These masks were optimized to work in a high background scenario, corresponding to live cell imaging conditions - namely, 3500 signal photons, and a mean background of 50 photons per pixels. We note that ‘signal photons’ refers to photons originating from the emitter and detected by the camera, integrated over the PSF. The PSF measurements are obtained by imaging a 200 nm fluorescent bead attached to a microscope cover slip, and scanning the microscope objective such that the focal plane is above or below the bead. Note that the physically ‘sensible’ requirements mentioned above, namely, concentrating the light into lobes and having the PSF shape vary quickly as a function of z, are indeed fulfilled by the resulting PSF, however this was

ACS Paragon Plus Environment

8

Page 9 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

achieved without adding these requirements explicitly – these beneficial features arise naturally as a consequence of optimizing our objective function based on the CRLB. The calculated precision (standard deviation, defined as

√0123

) for a signal of 3500 photons

over a mean background of 50 photons per pixel is also plotted (Figs. 2d and 2h). According to the CRLB calculations, under these signal-to-noise conditions, the PSF is capable of exhibiting a mean precision of 12 nm, 12 nm, 21 nm (29 nm, 29 nm, 53 nm) in estimating x, y and z, respectively, using the 6 µm PSF (20 µm PSF).

See the Supporting Information for further

details on the performance of Tetrapod PSFs optimized for different z-ranges.

Figure 2. Tetrapod masks, optimized for z-ranges of 6 µm (a-d) and 20 µm (e-h). 6 µm and 20 µm Tetrapod phase patterns (a,e). Numerical PSF calculation for various z positions (b,f), and experimentally measured bead images (c,g), each image normalized by maximum intensity. (d,h) Numerically calculated precision, defined as √0123 for x, y and z determination, using 3500 signal photons on a background of 50 mean photons per pixel.

ACS Paragon Plus Environment

9

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 10 of 23

In order to experimentally demonstrate the applicability of the Tetrapod PSFs, we first use the 20 µm Tetrapod mask for experimental flow profiling in a microfluidic channel (Fig. 3). Microfluidic devices are useful for obtaining various measurements of interest, ranging from molecular diffusion coefficients 38, 39 or pH 40, spanning 3D vascular modeling 41 to inexpensive clinical diagnostic applications 42. The use of PSF engineering provides a simple (scan-free) and precise method for 3D flow profiling in such devices. Initially, we investigate the well-studied laminar flow regime

43

.

Water with a low

concentration (~0.5 pM) of fluorescent beads is flowing through a glass microfluidic channel with a semi-circular cross-section (50 ± 8 8 width × 20 ± 3 8 height near the center of the channel). A 641 nm laser illuminates the sample, the widefield fluorescence signal from the flowing beads is recorded, and a video is taken (5 ms exposures at 20 Hz). The beads are localized as they flow, and the profile of the flow is then obtained by analyzing their trajectories, a technique known as particle-image-velocimetry (PIV

44, 45

). Three-dimensional localization of

each bead in each frame is achieved using maximum-likelihood estimation

15

based on fitting

each image to a numerical model of the PSF and taking into account objective defocus and refractive index mismatch between sample and mounting medium (see Supporting Information for details).

ACS Paragon Plus Environment

10

Page 11 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Figure 3. Micro-fluidic channel setup. Water with fluorescent beads (200 nm diameter, 625 nm absorption/645 nm emission) is flowing through a micro-channel, placed on top of a microscope objective of an inverted microscope. As the beads flow, they are excited by a laser (641 nm), and their fluorescence signal is captured. Two beads are illustrated. Figure 4a shows an example raw-data frame (See also Supporting Information Movie 1), where three beads at different x,y,z positions can be simultaneously seen. By accumulating many such frames (~16000), the mean flow velocity as a function of x, y and z (namely C , D , ( ) is calculated. Figure 4b shows the y-z profile of the flow (which is in the x direction), whereas Fig. 4c and 4d show 1D cross-sections near the center of the channel. The C profile (black) is seen to be quite reasonably parabolic, while the mean D and ( (blue, red), are very small in comparison (mean values of D , ( are 0.36, -0.39 /F , respectively – two order of magnitudes smaller than the maximal C ). This fits well with a laminar flow model, assuming no slip conditions

43

, which is applicable for our experimental conditions, where the Reynolds number

is 1 G 4 ⋅ 10*K .

ACS Paragon Plus Environment

11

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 23

Figure 4. Laminar flow measurement. (a) Example raw frame, showing three emitters at different x,y,z positions, flowing in the x direction. (b) Experimentally derived two-dimensional mean C map, averaged over x (y-z cross-section). (c),(d) One-dimensional slices from (b), showing mean C , D and ( velocities. As predicted by a laminar flow model, C (black) has a parabolic profile, whereas D and ( (blue, red) are negligible by comparison. Error bars represent +/- 1 s.d.

Various quantities of interest can be obtained by a quantitative study of the measured bead trajectories. First, by analyzing mean-squared-displacement (MSD) curves in the y and z directions (i.e., orthogonal to the flow), we infer a mean diffusion coefficient of 1.20 ± 0.13 1.24 ± 0.19 8 /F% in the y (z) direction. This compares very well with the theoretical value given by the Einstein–Smoluchowski relation for a 200 nm spherical diffuser in water 46, 47 of 1.08 ± 0.03 8 /F%. Secondly, from the MSD curve intercepts, the localization precision can be approximated

48

. The resulting derived precisions are 76 nm (87 nm) in the y (z)

estimation. See Supporting Information for MSD curves and further details. A total number of 3773 emitters were tracked, producing 52332 data-points (localizations).

ACS Paragon Plus Environment

12

Page 13 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

To demonstrate a full 3D velocity profile, we image the microfluidic channel right under the input facet where the bead solution enters the microfluidic channel (see inset cartoon in Fig. 5). The beads are then imaged as they enter the channel, thereby exhibiting considerable flow also in the z direction. Figure 5 shows the resulting flow profile. Figure 5a contains three-dimensional trajectories of 100 beads, with color coding normalized per trajectory start (blue = first frame in trajectory) to end (yellow = last frame in trajectory). A typical trajectory lasts ~1.5 seconds. Figure 5b shows an x-z cross-section of the flow, near the center of the channel (in y). See Supporting Information Movies 2 and 3 for further visualizations.

Figure 5. Three dimensional flow measurement. (a) Three-dimensional flow trajectories of a 100-bead subset at the entrance facet of the microfluidic channel (see inset in (b)), color-coded

ACS Paragon Plus Environment

13

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 23

by normalized trajectory duration (blue – start, yellow – end). Typical trajectory duration ~1.5 s. (b) An x-z slice. The flow is profiled over ~30 µm in z. The data is binned in 3x3x3 µm3 x-y-z bins, arrow length linearly encodes velocity (longest arrow corresponds to 22.5 µm/s).

There are several factors contributing to localization error in the described flow experiments: One factor is signal-to-noise ratio, determined by the finite number of signal photons relative to background photons. However, the measured beads are very bright (number of signal photons per frame on the order of ~100,000), and the background is sufficiently low (a few photons per pixel) such that this is not a major contributor. Motion blur is another cause for localization error, however this as well is probably not a major factor, since our exposure time (5 ms) is short in light of the velocities and diffusion rates of the measured beads, and our simulations indicate that this has minor effects on localization precision. The most dominant contribution to localization error comes from model mismatch – namely, the model to which each measured PSF is fit deviates from the real PSF. This is partly because of aberrations in the optical system, and mostly because of aberrations related to refractive index mismatch: As is well known

30, 49, 50

, the PSF of a point source (bead) in water is somewhat

different from the PSF of a bead on a cover-slip, and therefore difficult to calibrate experimentally because it is challenging to locate point sources at precisely known depths. Our imaging model does include the effect of refractive index mismatch, however even this modeling has limited precision. The problem of correcting for index-mismatch-related aberrations in microscopy is a long-standing one, and a subject of ongoing research.

The use of more

51

), will decrease any

sophisticated numerical models and possibly calibration methods (e.g. localization error that accompanies these kinds of measurements.

ACS Paragon Plus Environment

14

Page 15 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Another contribution to localization error comes from overlapping PSFs of closely spaced emitters: When localizing an emitter, photons from a different, nearby emitter can contribute to non-homogenous background noise, and degrade localization performance. For a qualitative discussion and an illustrative example see Supporting Information. Naturally, an appealing application of PSF optimization is the study of biological phenomena by 3D tracking of nanoscale objects. In order to demonstrate the utility of the Tetrapod PSF in real biological conditions, we use a Tetrapod mask optimized for a 6 µm z-range to track the diffusive motion of single quantum dots attached to lipid molecules in live-cell membranes. Figure 6a shows an example frame from a tracking experiment following the motion of a lipidanchored quantum-dot (phosphoethanolamine (PE)) on the surface of a living HeLa cell (see Supporting Information). The extracted 3D trajectory is plotted in Fig. 6b. The mean number of detected signal photons per 50 ms frame is ~10,000, with a mean background of ~40 photons per pixel. The precision in this measurement is estimated to be 10 nm in the x-y coordinates and 17 nm in the z coordinate. This is measured by localizing immobilized quantum dots on the surface of the sample’s cover-slip and averaging the standard deviation in localization, for several defocus values (see Supporting Information). Interestingly, the 3D trajectory of the molecule tracked in Fig. 6 seems to be constrained to an approximately spherical surface. The sphere that the trajectory outlines is in fact visible in the white light image (Fig. 6a), and is probably a detached bleb from a nearby cell, pressed against the cell membrane from the outside. When fitting the molecule’s trajectory to a sphere, the radius corresponds very well with the value obtained from the white light image (see Supporting Information Movie 4).

ACS Paragon Plus Environment

15

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 23

Figure 6. Long-term three-dimensional (3D) tracking of a Qdot-labeled phosphoethanolamine (PE) lipid on the surface of a live HeLa cell. (a) Brightfield impression with overlayed fluorescence channel (one 50 ms frame), showing signal from a quantum-dot-labeled PE lipid. Scale bar: 10 µm. (b) Inferred 3D trajectory as a function of time (55 seconds total), color-coded with time progression, and planar projections of the motion shown in gray on each of the bounding surfaces. The total motion over an axial range of 5.67 µm is mapped. Maximumlikelihood estimation on a frame-by-frame basis produces the trajectory. Measured fluorescence data is given in Supporting Information Movie 5.

While the example in Fig. 6 shows a single tracked molecule, a major advantage of the PSFengineering tracking method is that it allows for simultaneous tracking of multiple emitters. See the Supporting Information for additional cell tracking examples, containing multiple molecules tracked simultaneously. Importantly, these PSFs are directly applicable to single-molecule localization microscopy 55

.

52-

In order to demonstrate such capabilities, we first immobilize single fluorescent dye

molecules (Alexa Fluor 647) on a cover-slip. We then excite the molecules and measure their fluorescence, using a 6 µm Tetrapod PSF. Each molecule’s position is then localized repeatedly.

ACS Paragon Plus Environment

16

Page 17 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

We repeat this for various defocus values throughout a ~7 µm z-range. For a mean number of ~6000 detected signal photons and ~38 background photons per pixel, the mean statistical localization precision, namely the standard deviation of localizations, averaged over the entire zrange, is 15 nm, 12 nm and 29 nm in x, y and z, respectively. See the Supporting Information for this result. In summary, we present an imaging modality based on optimized Tetrapod PSFs, capable of high-precision imaging throughout an unprecedented and tunable axial range.

We

experimentally demonstrate large-axial-range tracking in a microfluidic device, tracking under biological conditions of a Qdot-labeled molecule diffusing on the membrane surface of live mammalian cells, as well as single-fluorophore localization capabilities over a ~7 µm axial range. Use of the Tetrapod PSFs provides a solution to a long-standing problem of highprecision, scan-free tracking of multiple emitters over an exceptionally large z-range. Note that the experiments described in this work were performed using a liquid-crystal-based SLM in the Fourier plane.

However, replacing the SLM with a specially fabricated phase mask will

substantially increase photon efficiency, which is a limiting factor in precision for singlemolecule imaging. Further, any localization shifts arising from fixed emission dipole orientations apply equally well to this PSF as to any other, and these may be addressed in various ways 23, 56, 57

.

ASSOCIATED CONTENT Supporting Information. Theoretical and numerical implementation details on imaging model and localization method, Tetrapod phase mask characterization, raw data movies, MSD curves

ACS Paragon Plus Environment

17

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 23

and analysis results, additional membrane tracking examples, and precision measurements. This material is available free of charge via the Internet at http://pubs.acs.org. AUTHOR INFORMATION Corresponding Author *Email: [email protected] Present Address ┼

S.J.S.: Max Planck Institute for Biophysical Chemistry, Am Fassberg 11, 37077 Göttingen, Germany.

Author Contributions The manuscript was written through contributions of all authors. All authors have given approval to the final version of the manuscript. Funding Sources This work was supported by the National Institutes of Health, National Institute of General Medical Sciences Grant No. R01GM085437. We also acknowledge funding from the U.S. National Institutes of Health, National Eye Institute, Grant PN2EY016525 for postdoc support (S.J.S.).

ACS Paragon Plus Environment

18

Page 19 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

REFERENCES (1) Dupont, A.; Lamb, D. C. Nanoscale 2011, 11, 4532-4541. (2) Gelles, J.; Schnapp, B. J.; Sheetz, M. P. Nature 1988, 450-453. (3) Qian, H.; Sheetz, M. P.; Elson, E. L. Biophys. J. 1991, 4, 910-921. (4) Saxton, M. J.; Jacobson, K. Annu. Rev. Biophys. Biomol. Struct. 1997, 373-399. (5) Fujiwara, T.; Ritchie, K.; Murakoshi, H.; Jacobson, K.; Kusumi, A. J. Cell Biol. 2002, 10711081. (6) Thompson, M. A.; Casolari, J. M.; Badieirostami, M.; Brown, P. O.; Moerner, W. E. Proc. Natl. Acad. Sci. U. S. A. 2010, 17864-17871. (7) Schmidt, T.; Schutz, G. J.; Baumgartner, W.; Gruber, H. J.; Schindler, H. Proc. Natl. Acad. Sci. U. S. A. 1996, 2926-2929. (8) Kim, S. Y.; Gitai, Z.; Kinkhabwala, A.; Shapiro, L.; Moerner, W. E. Proc. Natl. Acad. Sci. U. S. A. 2006, 29, 10929-10934. (9) Werley, C. A.; Moerner, W. E. J. Phys. Chem. B 2006, 18939-18944. (10) Small, A.; Stahlheber, S. Nat. Methods 2014, 3, 267-279. (11) Thompson, M. A.; Lew, M. D.; Badieirostami, M.; Moerner, W. E. Nano Lett. 2010, 1, 211218. (12) Peters, I. M.; de Grooth, B. G.; Schins, J. M.; Figdor, C. G.; Greve, J. Rev. Sci. Instrum. 1998, 7, 2762-2766. (13) Welsher, K.; Yang, H. Nature nanotechnology 2014, 3, 198-203. (14) Corle, T. R.; Kino, G. S. Confocal Scanning Optical Microscopy and Related Imaging Systems; Academic Press: San Diego, 1996; . (15) Ober, R. J.; Ram, S.; Ward, E. S. Biophys. J. 2004, 2, 1185-1200. (16) Ram, S.; Prabhat, P.; Chao, J.; Ward, E. S.; Ober, R. J. Biophys. J. 2008, 12, 6025-6043. (17) Hajj, B.; Wisniewski, J.; Beheiry, M. E.; Chen, J.; Ravyakin, A.; Wu, C.; Dahan, M. Proc. Natl. Acad. Sci. U. S. A. 2014, 17480-17485. (18) Kao, H. P.; Verkman, A. S. Biophys. J. 1994, 3, 1291-1300.

ACS Paragon Plus Environment

19

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 23

(19) Holtzer, L.; Meckel, T.; Schmidt, T. Appl. Phys. Lett. 2007, 053902. (20) Huang, B.; Wang, W.; Bates, M.; Zhuang, X. Science 2008, 5864, 810-813. (21) Piestun, R.; Schechner, Y. Y.; Shamir, J. J. Opt. Soc. Am. A 2000, 294-303. (22) Pavani, S. R. P.; Thompson, M. A.; Biteen, J. S.; Lord, S. J.; Liu, N.; Twieg, R. J.; Piestun, R.; Moerner, W. E. Proc. Natl. Acad. Sci. U. S. A. 2009, 9, 2995-2999. (23) Backlund, M. P.; Lew, M. D.; Backer, A. S.; Sahl, S. J.; Grover, G.; Agrawal, A.; Piestun, R.; Moerner, W. E. Proc. Natl. Acad. Sci. U. S. A. 2012, 47, 19087-19092. (24) Lew, M. D.; Lee, S. F.; Badieirostami, M.; Moerner, W. E. Opt. Lett. 2011, 2, 202-204. (25) Backer, A. S.; Backlund, M. P.; Diezmann, A. R.; Sahl, S. J.; Moerner, W. E. Appl. Phys. Lett. 2014, 19, 193701-1-193701-5. (26) Jia, S.; Vaughan, J. C.; Zhuang, X. Nat. Photonics 2014, 302-306. (27) Shechtman, Y.; Sahl, S. J.; Backer, A. S.; Moerner, W. Phys. Rev. Lett. 2014, 13, 133902. (28) Bettega, P.; Calzolari, S. M.; Doglia, B.; Duliom, L.; Tallone, A. M.; Villa, D. Int. J. Radiat. Biol. 1998, 3, 397-403. (29) Lee, J.; Cuddihy, M. J.; Kotov, N. A. Tissue Engineering Part B: Reviews 2008, 1, 61-86. (30) Backer, A. S.; Moerner, W. E. J. Phys. Chem. B 2014, 28, 8313-8329. (31) Gahlmann, A.; Ptacin, J. L.; Grover, G.; Quirin, S.; von Diezmann, A. R. S.; Lee, M. K.; Backlund, M. P.; Shapiro, L.; Piestun, R.; Moerner, W. E. Nano Lett. 2013, 987-993. (32) Goodman, J. W. Introduction to Fourier Optics; Roberts & Company Publishers: Greenwood Village, CO, 2005; . (33) Badieirostami, M.; Lew, M. D.; Thompson, M. A.; Moerner, W. E. Appl. Phys. Lett. 2010, 16, 161103. (34) Abraham, A. V.; Ram, S.; Chao, J.; Ward, E. S.; Ober, R. J. Opt. Express 2009, 2335223373. (35) Smith, C. S.; Joseph, N.; Rieger, B.; Lidke, K. A. Nat. Methods 2010, 373-375. (36) Kay, S. M. Fundamentals of Statistical Signal Processing: Estimation Theory; Prentice-Hall PTR: Englewood Cliffs, NJ, 1993; . (37) Born, M.; Wolf, E. Principles of Optics; Cambridge University Press: Cambridge, 1999; .

ACS Paragon Plus Environment

20

Page 21 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

(38) Kamholz, A. E.; Weigl, B. H.; Finlayson, B. A.; Yager, P. Anal. Chem. 1999, 23, 53405347. (39) Kamholz, A. E.; Schilling, E. A.; Yager, P. Biophys. J. 2001, 4, 1967-1972. (40) Weigl, B.; Yager, P. Sensors Actuators B: Chem. 1997, 1, 452-457. (41) Zervantonakis, I. K.; Hughes-Alford, S. K.; Charest, J. L.; Condeelis, J. S.; Gertler, F. B.; Kamm, R. D. Proc. Natl. Acad. Sci. U. S. A. 2012, 34, 13515-13520. (42) Yager, P.; Edwards, T.; Fu, E.; Helton, K.; Nelson, K.; Tam, M. R.; Weigl, B. H. Nature 2006, 7101, 412-418. (43) Batchelor, G. K. An introduction to fluid dynamics; Cambridge university press: 2000; . (44) Adrian, R. J.; Westerweel, J. Particle image velocimetry; Cambridge University Press: 2011; Vol. 30. (45) Cierpka, C.; Kähler, C. Journal of visualization 2012, 1, 1-31. (46) Einstein, A. Annalen der physik 1905, 8, 549-560. (47) Von Smoluchowski, M. Annalen der physik 1906, 14, 756-780. (48) Savin, T.; Doyle, P. S. 2005, 1, 623-638. (49) Hanser, B.; Gustafsson, M.; Agard, D. J. Microsc. 2004, 1, 32-48. (50) Hell, S. W.; Reiner, G.; Cremer, C.; Stelzer, E. H. K. J. Microsc. 1993, 3, 391-405. (51) Mcgorty, R.; Schnitzbauer, J.; Zhang, W.; Huang, B. Opt. Lett. 2014, 275. (52) Betzig, E.; Patterson, G. H.; Sougrat, R.; Lindwasser, O. W.; Olenych, S.; Bonifacino, J. S.; Davidson, M. W.; Lippincott-Schwartz, J.; Hess, H. F. Science 2006, 5793, 1642-1645. (53) Hess, S. T.; Girirajan, T. P. K.; Mason, M. D. Biophys. J. 2006, 11, 4258-4272. (54) Rust, M. J.; Bates, M.; Zhuang, X. Nat. Methods 2006, 10, 793-796. (55) Sahl, S. J.; Moerner, W. E. Curr. Opin. Struct. Biol. 2013, 5, 778-787. (56) Lew, M. D.; Backlund, M. P.; Moerner, W. E. Nano Lett. 2013, 9, 3967-3972. (57) Backlund, M. P.; Lew, M. D.; Backer A. S.; Sahl, S. J.; Moerner, W. E. ChemPhysChem 2014, 587-599.

ACS Paragon Plus Environment

21

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 23

For TOC only

ACS Paragon Plus Environment

22

Page 23 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

graphic for the Table of Contents 89x32mm (120 x 120 DPI)

ACS Paragon Plus Environment