Probing Solid−Liquid Interfaces Using Radiotracer Technology

Jul 30, 2008 - Leena Nebhani , Sebastian Sinnwell , Andrew J. Inglis , Martina H. Stenzel , Christopher Barner-Kowollik , Leonie Barner. Macromolecula...
2 downloads 0 Views 378KB Size
Chem. Mater. 2008, 20, 5375–5380

5375

Probing Solid-Liquid Interfaces Using Radiotracer Technology: Characterization of Functionalized Microspheres Stephen Huang,† Raymond Joso,‡ Alex Fuchs,† Leonie Barner,*,‡ and Suzanne V. Smith*,† Centre of Excellence Antimatter-matter Studies (CAMS), Australian Nuclear Science and Technology Organisation (ANSTO), P.O. Box No. 1, Menai, NSW 2234, Australia, and Centre for AdVanced Macromolecular Design (CAMD), School of Chemical Sciences and Engineering, The UniVersity of New South Wales, Sydney, NSW 2052, Australia ReceiVed January 25, 2008. ReVised Manuscript ReceiVed May 21, 2008

This study explores the use of nuclear probes (radiolabeling techniques) for the quantification of available, reactive groups on solid surfaces and their role in the engineering of materials for biosensor applications. Microspheres were synthesized with reactive carboxylate groups as conjugation sites for proteins. The carboxylate groups were reacted with three bifunctional ligands, sarar, aminobenzyl-cyclen, and aminobenzyl-dota. The reaction conditions used were similar to that employed for the conjugation of proteins and optimized for the concentration of reactants (bifunctional ligand and EDC), pH, and time at ∼21 °C. Of the three bifunctional ligands conjugated to the microsphere, sarar proved to be the most efficient. Optimum reaction conditions employed molar ratios of 1:20:100 for microspheres (estimated carboxylate groups of 1.1 × 10-7 per milligram of microspheres):sarar:EDC at pH 5.0 for 1 h, followed by 57/natCo radiolabeling at pH 7.0. The study demonstrates how nuclear probes with high specificity and sensitiviy can provide invaluable information on available reactive sites on solid surfaces at extremely low concentrations (>10-10 M) in a range of media. More importantly the nuclear probes enable the characterization of the surfaces of new materials in a non-destructive manner under conditions relevant to the engineering of the materials and ultimately the desired biosensor.

Introduction The demand for more rapid and accurate analytical techniques capable of providing reliable information about the presence of compounds such as drugs, metabolites, biomarkers, flavors, environmental, food contaminants, and toxic chemicals, without time-consuming isolation and sample preparation steps, continues to increase.1 The biosensor area therefore strongly attracts the attention of the nanotechnology field. However, the ability to assemble and integrate various nanoscale components is essential for their effective application. One significant challenge of this area is the ability to characterize functionalized surfaces and to connect biomarkers to these functionalized solid surfaces with molecular precision. Various strategies for the synthesis of polymeric microspheres using heterogeneous polymerization methods such as emulsion, suspension, dispersion, and precipitation polymerization continue to evolve.2 We are now able to prepare microspheres, of varying size, potentially large surface areas, and high mobility that can be easily recovered from suspension. The interaction of these materials with their environment is largely controlled * Corresponding authors. E-mail [email protected] (S.V.S.); leonie.barner@ macroarc.de (L.B.). Tel.: +61 2 9717 3125. Fax: +61 2 9543 7179 (S.V.S.). Tel.: +49 721 608 5641. Fax: +49 721 608 3153. Current address: Fraunhofer Institut for Chemische Technologie, Joseph-von-Fraunhofer-Str. 7, 76327 Pfinztal, Berghausen, Germany (L.B.). † Australian Nuclear Science and Technology Organisation. ‡ The University of New South Wales.

(1) Coelho, M. A. N.; Gliozzi, A.; Mo¨hwald, H.; Perez, E.; Sleytr, U.; Vogel, H.; Winterhalter, M. IEEE Trans. Nanobioscience 2004, 3, 3. (2) Kawaguchi, H. Prog. Polym. Sci. 2000, 25, 1171.

by their surface chemistry.3 Hence the ability to effectively functionalize the surfaces of these systems as part of, or during, their engineering is critical in order to capitalizing on the significant unique features of these materials.4 A vital part of the design of sensing materials is the physical and chemical characterization of the functionalized surfaces with or without the sensor. Essential to optimizing both the application and the engineering of these materials is the ability to obtain the information about these surfaces in a non-destructive manner or with minimal impact. Information such as the number and type of aVailable functional groups under the conditions that ultimately the sensor is to be applied is critical to optimizing the design and application of the biosensor. Hence for biosensors that may be used to determine the amount of protein or drug in an unknown solution, it is important that they are evaluated in relevant media systems.5 Conjugation of detection tags such as radiolabeled bifunctional chelators or fluorescence labels to complex tertiary structures such as proteins is well established.6 Conditions for conjugation of multiple tags to a protein (which can contain multiple reactive sites) in order to sustain the activity of the protein are well understood. These methodologies are highly relevant where there is an interest to attach proteins to the functionalized surface of micro- or nanoparticles. These tags can be used to determine the number of active sites on (3) (4) (5) (6)

Dai, L.; He, P.; Li, S. Nanotechnology 2003, 14, 1081. Grubbs, R. B. Nat. Mater. 2007, 6, 553. Okubo, M.; Suzuki, T.; Tsuda, N. Colloid Polym. Sci. 2006, 284, 1319. Shim, H. W.; Lee, J. H.; Hwang, T. S.; Rhee, Y. W.; Bae, Y. M.; Choi, J. S.; Han, J.; Lee, C. S. Biosens. Bioelectron. 2007, 22, 3188.

10.1021/cm800248s CCC: $40.75  2008 American Chemical Society Published on Web 07/30/2008

5376

Chem. Mater., Vol. 20, No. 16, 2008

Huang et al.

investigate which bifunctional chelator is more efficient for reacting with the surface of the microsphere and determining the number of aVailable carboxylates groups in the microspheres. Experimental Section

Figure 1. Bifunctional ligands used to radiolabel functionalized microspheres.

the microspheres and therefore predict the loading capacity of the desired protein. They can also be used to optimize the reaction conditions for further functionalization of the surface and provide valuable information for optimizing the engineering of the original microspheres. Radiotracers are particularly attractive for such applications as they are highly sensitive, non-destructive tools that can be used to probe solid-liquid interfaces. Detection limits of >10-3 ppb are readily achieved, and more importantly they are insensitive to matrix and media, that is, indiscriminate to whether the radioactive signals originate from solid surfaces or from media. Hence minimal sample sizes (0.8

0.8