Purity Determination by Capillary Electrophoresis Sodium Hexadecyl

Jan 22, 2018 - Biophysical Characterization Group, Bristol-Myers Squibb Company, 311 Pennington Rocky Hill Road, Pennington, New Jersey 08534, United ...
5 downloads 8 Views 1MB Size
Subscriber access provided by UNIV OF DURHAM

Article

Purity Determination by Capillary Electrophoresis Sodium Hexadecyl Sulfate (CE-SHS): A Novel application For Therapeutic Protein Characterization Jeff Beckman, Yuanli Song, Yan Gu, Sergey Voronov, Naresh Chennamsetty, Stanley R. Krystek, Nesredin A. Mussa, and Zheng Jian Li Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.7b03831 • Publication Date (Web): 22 Jan 2018 Downloaded from http://pubs.acs.org on January 23, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Purity Determination by Capillary Electrophoresis Sodium Hexadecyl Sulfate (CESHS): A Novel application For Therapeutic Protein Characterization

Jeff Beckman*1, Yuanli Song1, Yan Gu1, Sergey Voronov1, Naresh Chennamsetty2, Stanley Krystek3, Nesredin Mussa1, and Zheng Jian Li1.

1

Biologics Development, Bristol-Myers Squibb Company, 38 Jackson Road, Devens, MA 01434, USA.

2

Biophysical Characterization Group, Bristol-Myers Squibb Company, 311 Pennington Rocky Hill Road, Pennington, NJ 3

Drug Discovery Research, Bristol-Myers Squibb Company, R. 206 and Province Line Road, Princeton, NJ

*Corresponding Author: Jeff Beckman, PhD

[email protected]

Phone: 978-784-6916 Fax: 978-784-6381

1 ACS Paragon Plus Environment

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 23

1

ABSTRACT

2

Capillary Gel Electrophoresis using sodium dodecyl sulfate (CE-SDS) is used commercially to provide

3

quantitative purity data for therapeutic protein characterization and release. In CE-SDS, proteins are

4

denatured under reducing or non-reducing conditions in the presence of SDS and electrophoretically

5

separated by molecular weight and hydrodynamic radius through a sieving polymer matrix. Acceptable

6

performance of this method would yield protein peaks that are baseline resolved and symmetrical.

7

Nominal CE-SDS conditions and parameters are not optimal for all therapeutic proteins, specifically for

8

Recombinant Therapeutic Protein-1 (RTP-1), where acceptable resolution and peak symmetry were not

9

achieved. The application of longer alkyl chain detergents in the running buffer matrix substantially

10

improved assay performance. Matrix running buffer containing sodium hexadecyl sulfate (SHS) in-

11

creased peak resolution and plate count 3 and 8-fold respectively compared to a traditional SDS-based

12

running gel matrix. At BMS we developed and qualified a viable method for the characterization and

13

release of RTP-1 using an SHS-containing running buffer matrix. This work underscores the potential

14

of detergents other than SDS to enhance the resolution and separation power of CE-based separation

15

methods.

16

2 ACS Paragon Plus Environment

Page 3 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

17

INTRODUCTION

18

Commercialization of Therapeutic Proteins require analytical techniques that can measure product

19

heterogeneity from the complexity of biosynthesis (1,2). Towards this end, Capillary Gel Electrophore-

20

sis (CGE) contributes to our understanding of protein size heterogeneity by separating and quantitative-

21

ly detecting proteins by molecular weight and hydrodynamic radius (2-4). In this procedure, the protein

22

is denatured with charged detergent to produce protein-detergent complexes with a uniform mass/charge

23

ratio that is separated by molecular weight while sieving through a capillary filled with a hydrophilic gel

24

buffer solution. This is followed by UV detection ideally at a point along the capillary when quantifica-

25

tion of peaks can occur, which requires adequate protein peak separation efficiency (PSE), as defined by

26

high plate counts and resolution. CGE works well for most therapeutic proteins in this regard, specifi-

27

cally for IgGs, and has been accepted as standard for the evaluation of product purity in the biotechnol-

28

ogy industry (5).

29

Sodium dodecyl sulfate (SDS) has been used as the default detergent for CGE separations largely be-

30

cause of its establishment in conventional polyacrylamide gel electrophoresis (SDS-PAGE) (6,7). In

31

addition, SDS is able to uniformly bind to a typical protein at a ratio of 1.4 g SDS to 1 g protein, ensur-

32

ing uniform mass/charge ratios of SDS:Protein complexes in most cases (8). Hence CGE is commonly

33

referred to as SDS-CGE or CE-SDS.

34

However, there are situations where CE-SDS yields poor protein PSE, which suggests relatively low

35

SDS binding affinity and/or incomplete denaturation, which calls for an alternative method evaluation to

36

obtain the optimal purity data.

37

For this purpose we investigated alternatives to SDS. It is known that not all proteins bind SDS uni-

38

formly due to the charge or glycosylation profile of a protein, e.g. (9,10), and numerous studies have

39

demonstrated that the regulation of SDS affinity to protein requires specific modifications to the deter3 ACS Paragon Plus Environment

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 23

40

gent and/or protein (10-14). For example, elongating the SDS hydrocarbon chain from 12 to 14 carbon

41

lengths was shown to increase its protein affinity, underscoring the importance of hydrophobicity (14).

42

Thus, for proteins that exhibit poor PSE by CE-SDS it is reasonable to postulate that an increase in de-

43

tergent hydrophobicity can improve PSE by increasing the affinity of the detergent to the protein. Fig-

44

ure 1 shows overlay electropherograms of RTP-1, an Fc-Adnectin fusion protein with a molecular

45

weight of ~ 75 kDa (for a review of the characteristics of the Adnectin domain refer to (15)), run under

46

typical CE-SDS conditions and with gel matrix containing sodium hexadecyl sulfate (SHS). The pres-

47

ence of SHS led to a discernible improvement in PSE, resulting in baseline separation of the main Pro-

48

tein peak from a prominent impurity peak (Impurity Peak 1, or IP1, in Figure 1) which was identified as

49

a fragment of RTP-1 of ~ 2 kDa less than the parent molecule (data not shown). The improved peak

50

shape and resolution extended the working range for the assay with the potential to increase assay sensi-

51

tivity without compromising linearity. Specifically, the sample load could be increased 3-4 fold, im-

52

proving signal-to-noise by a comparable magnitude, and allowing better quantification of low abundant

53

peaks without causing significant migration overlap of the main and IP1 peaks (Figure 2; SHS Gel Buff-

54

er data). Overlap in this case led to a decrease in the relative amount of IP1 which compromised the as-

55

say by overestimating sample purity (Figure 2, SDS Gel Buffer data). Potential mechanisms for the im-

56

provements observed are discussed.

57 58

MATERIALS AND METHODS

59

Reagents. Glycerol (≥ 99%), Ethylenediaminetetraacetic acid (EDTA, ≥ 99%) dextran (MW ~ 2000

60

kDa), Tris(hydroxymethyl)aminomethane (Trizma, ≥ 99.9%), Boric acid (≥ 99.5%), and β-

61

mercaptoethanol (≥ 99%) were purchased from Sigma (St. Louis, MO). Powders of sodium undecyl

62

sulfate (SUS, ≥ 99%), sodium tetradecyl sulfate (STS, > 95%), and sodium hexadecyl sulfate (SHS, > 4 ACS Paragon Plus Environment

Page 5 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

63

98%) were purchased from Alfa Aesar (Wood Hill, MA). Powdered sodium dodecyl sulfate (SDS, >

64

99%) was purchased from Avantor (Center Valley, PA). For CGE assay applications, 10 kDa internal

65

standard (I.S.), 0.1 N acid/base wash solutions, SDS-MW gel and SDS-sample buffers, pre-assembled

66

bare-fused silica capillary cartridges, and 2 mL universal vials and caps were purchased from AB Sciex

67

(Framingham, MA).

68

Sample Preparation. Unless stated otherwise, protein samples were prepared at 0.9 mg/mL with

69

0.76% SDS, 5% β-mercaptoethanol and 76 mM Tris-HCl. 500 mM Tris-HCl pH 9.0 was prepared using

70

a Schott pH meter equipped with an SI Analytics probe then deionized water and detergent powder add-

71

ed to reach the desired concentrations. For relatively hydrophobic detergents, dissolving the powders

72

into the Tris-HCl buffer required a combination of sonication and heating in a 70° water bath.

73

Preparation of Gel Buffer Solutions. Gel buffers were prepared as follows: Trizma base, boric acid,

74

EDTA, and glycerol were mixed together and filtered through a 0.2 micron filter. Detergent(s) and dex-

75

tran were added subsequently. Once all components were in solution, the liquid was slowly poured into

76

appropriately sized PTFE bottles purchased from Thermo Scientific (Waltham, MA) and stored at room

77

temperature.

78

Capillary Electrophoresis. CGE experiments were performed on a PA800+ instrument equipped

79

with a photodiode array detector and 32Karat acquisition software (Version 9) (AB Sciex, Framingham,

80

MA). Electrophoretic separations occurred in 50 µm internal diameter pre-cut capillaries at 15kV con-

81

stant voltage with detection positioned 20 cm from the point of sample injection. Data from 32karat

82

was transferred to Empower 3 (Build 3471, Waters, Milford, MA) for data processing. Note that Em-

83

power is a chromatography-based software, thus migration times were converted to retention times and

84

calculated as such when assessing PSE, see Equations (1) and (2) below.

5 ACS Paragon Plus Environment

Analytical Chemistry

85

1 2 3 86 4 5 87 6 7 8 88 9 10 11 89 12 13 90 14 15 16 17 91 18 19 20 92 21 22 93 23 24 94 25 26 27 95 28 29 30 96 31 32 97 33 34 98 35 36 37 99 38 39 100 40 41 101 42 43 44 102 45 46 47 103 48 49 104 50 51 105 52 53 54 106 55 56 57 58 59 60

Page 6 of 23

Assessment of Peak Separation Efficiency (PSE). PSE was evaluated using the following equations for plate count (Equation (1)) and resolution (Equation (2)) (United States Pharmacopeia, Chapter 621). Empower calculates these values automatically as field options. N = 16(Rt/W)2

(1)

Where N = the number of theoretical plates (plate count), Rt is the retention/migration time of the peak, and W the peak width at baseline with tangents drawn to 61% of peak height. R = 2(Rt2 – Rt1)/(W2 + W1)

(2)

Where R = the resolution between two peaks, Rt1 and Rt2 the retention/migration times of peaks 1 and 2 respectively, and W2 + W1 the sum of peak widths at baseline with tangent lines drawn at 50% peak height. Differential Scanning Calorimetry. RTP-1 was diluted with 1 x PBS (150 mM NaCl and 20 mM phosphate pH 7.2) to 0.5 mg/mL with various amounts of SDS or SHS. Measurements were performed on a Malvern MicroCal VP-DSC system (Malvern Instruments, Northampton, MA) with a cell volume of approximately 0.5 mL. Temperature scans were conducted from 20 to 95°C at a scan rate of 1°C/min. A buffer reference scan was subtracted from each sample scan prior to concentration normalization. Baselines were created in Origin 7.0 (Origin Lab, Northampton, MA) by cubic interpolation of the pre- and post-transition baselines. Protein Modeling. The amino acid sequences of one of the two domains (domain 2) of RTP-1 was aligned to a similar domain with known structure as the template (data not shown). The 3D structures of the domain were built using the homology modeling tool MODELLER (16). The homology models were subjected to side chain optimization and minimization steps and followed by model validation. The surface charge of the domain was calculated according to the charge of residues and the accessibil6 ACS Paragon Plus Environment

Page 7 of 23

107

1 2 3 108 4 5 6 109 7 8 9 110 10 11 12 111 13 14 112 15 16 17 113 18 19 114 20 21 115 22 23 116 24 25 26 117 27 28 118 29 30 119 31 32 33 120 34 35 121 36 37 122 38 39 40 123 41 42 124 43 44 125 45 46 126 47 48 49 127 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

ity of the residue in the Propka output file using Adaptive Poisson-Boltzmann Solver (17). Finally, the electrostatic map was visualized by the program PyMOL (Schrödinger, LLC).

RESULTS AND DISCUSSION To keep the focus primarily on detergent hydrophobicity and its impact on PSE, the detergents evaluated all contained the same charged sulfate head group and sodium counter-ion, only varying in alkyl chain length. These included sodium undecyl sulfate (SUS), SDS, sodium tetradecyl sulfate (STS), and SHS. These detergents have alkyl chain lengths of 11, 12, 14 and 16 carbons respectively. This series was chosen because detergents with carbon lengths less than 10 weakly bind to protein (18) and, in our experience, carbon lengths longer than 16 are not readily soluble in the gel solutions. To directly attribute alkyl chain length to potential improvements in RTP-1 PSE, initial experiments included only the detergent of interest in both the running gel buffer and sample solutions. As shown in Figure 3, PSE significantly improved with longer alkyl chain length, with SHS improving plate count over SDS by 8fold (11820/1450, Figure 4) and resolution between the main peak and the impurity IP1 by 2.3-fold (1.8/0.8, Figure 4). SUS marginally improved PSE compared to SDS, a phenomenon observed previously with the slightly smaller sodium decyl sulfate (18) and was attributed to the ability of detergents with smaller alkyl chains to more uniformly coat elongated proteins (albeit with lower affinity). Interestingly, these authors also found that STS and SHS reduced PSE of their model proteins by PAGE (18). (We also observed this phenomenon. Refer to the section below entitled “Impact of SHS on the CGE Performance of Other Proteins”.) One explanation is that RTP-1 is not represented by these model proteins, as may be the case given its properties (discussed below).

7 ACS Paragon Plus Environment

Analytical Chemistry

128

1 2 3 129 4 5 130 6 7 8 131 9 10 132 11 12 13 133 14 15 134 16 17 135 18 19 136 20 21 22 137 23 24 138 25 26 139 27 28 29 140 30 31 141 32 33 142 34 35 36 143 37 38 39 144 40 41 145 42 43 146 44 45 46 147 47 48 148 49 50 149 51 52 53 150 54 55 56 57 58 59 60

Page 8 of 23

Note that the CGE resolving power by longer chain detergents was not simply dependent on concentration since SDS could not achieve the same level of PSE as SHS regardless of concentration (Figure 4). The Correlation Between Longer Hydrocarbon Chain Detergents and the Improved Resolution of RTP-1. Hypothetically, more stable detergent:protein complexes should result in higher separation efficiencies because the structure would be more homogeneous (18). Based on specific physical properties of RTP-1, SDS may be insufficient to stabilize a uniformly denatured RTP-1 complex and instead may require a more hydrophobic detergent. The Adnectin domain of RTP-1 is thermophilic, a property that suggests its overall structure is rigid (19) and contains a relatively hydrophobic core (20). Under native or denaturing conditions (with or without SDS), thermophilic proteins are often required to overcome higher transition-state energy barriers towards denaturation compared to typical proteins (19,21). Modeling studies show that one face of the Adnectin domain of RTP-1 has a high proportion of negative charge potential which would cause electrostatic repulsion of a detergent sulfate group. This repulsion may require the more hydrophobic tail of SHS to establish an overall energetically-favorable interaction with the hydrophobic core of the protein to initiate unfolding (Figure 5). Differential Scanning Calorimetry (DSC) was used to quantify the energy requirements of SHS and SDS to fully denature RTP-1 (22). Endotherm profiles of detergent:RTP-1 complexes were biphasic, represented as peaks E1 and E2 in Figure 6. E1 and E2 are attributed to RTP-1 Fc and Adnectin domains respectively (data not shown). Thermodynamic data are summarized in Table 1. The observed enthalpy changes during thermal denaturation of the Fc domain, represented by the E1 peak, are comparable for both detergents (Figure 6C). However, the thermal denaturation profiles of the thermophilic Adnectin, or E2, were different depending on the detergent as shown in Figure 6D. Less energy was required for SHS to denature this domain, specifically in the range of expected critical micellar concentrations

8 ACS Paragon Plus Environment

Page 9 of 23

151

1 2 3 152 4 5 6 153 7 8 154 9 10 155 11 12 13 156 14 15 16 157 17 18 158 19 20 21 159 22 23 24 160 25 26 161 27 28 162 29 30 31 163 32 33 164 34 35 165 36 37 38 166 39 40 41 167 42 43 168 44 45 169 46 47 48 49 170 50 51 171 52 53 172 54 55 56 57 58 59 60

Analytical Chemistry

(CMCs), which would be less than 8 mM for SDS and less than 2 mM for SHS (23) and suggests that the SHS:RTP-1 complex is more stable with SHS bound. Impact of SHS on the CGE Performance of Other Proteins. The antibody (mAb) RTP-2 also required SHS to ensure adequate CGE performance (Figure 7A). In contrast, mAb RTP-3 yielded comparable CGE performance using SDS or SHS (Figure 7B). Note that SDS added to SHS gel buffer solutions improved the PSE of the 10 kDa protein internal standard without impacting the PSE of RTP-1 (I.S.) (Figure 8). For this reason, CGE performance was optimized using a gel containing a mixture of SDS and SHS. Predicting When a Protein Requires SHS in the Gel Buffer. Given that the hydrophobic property of SHS is likely responsible for its relative impact on PSE, we attempted to correlate increased CGE resolving power using SHS and protein hydrophobicity in order to predict when to incorporate SHS into the gel. Each protein was ranked by its Spatial Aggregation Propensity (SAP) score, which measures the proportion of hydrophobic patches on the protein surface (24). The correlation appeared weak, however, since both relatively hydrophilic and hydrophobic proteins required SHS to improve CGE performance (data not shown). Alternatively, it appears that proteins with unusually high thermal stability require SHS to optimize CGE performance. This prediction is based on the characteristics of the Adnectin domain, which is both highly thermostable and resistant to SDS denaturation (Figure 6 and (15)). RTP-2 fit this prediction since its highest transition Tm exceeded that of RTP-3 by ~ 10°C (data not shown). Overall, the intention of this work is to make available a second viable option if SDS does not deliver optimal resolving power. It would be ideal to establish a model that would predict when to use SHS. For this, more relevant Protein examples are needed that would cover wide ranges in thermal stability 9 ACS Paragon Plus Environment

Analytical Chemistry

173

1 2 3 174 4 5 175 6 7 8 176 9 10 177 11 12 13 178 14 15 179 16 17 180 18 19 20 181 21 22 23 182 24 25 26 27 183 28 29 184 30 31 185 32 33 186 34 35 36 187 37 38 188 39 40 189 41 42 43 190 44 45 46 191 47 48 49 192 50 51 193 52 53 54 194 55 56 57 58 59 60

Page 10 of 23

and other physical properties, such as molecular weight. The trend in the biotechnology industry is to engineer proteins to have relatively high thermal stability so as to improve pharmaceutical stability, e.g. to maximize shelf-life (25), thus we should encounter increasingly more proteins like RTP-1 and -2. Development of an SHS-Containing Gel Buffer and Qualification of a CE-SHS Purity Method for Product Release. The SHS gel buffer composition was developed to be robust, reproducible and stable, with an expiry of ≥15 months. The final RTP-1 purity method was successfully qualified with a nominal protein load 3-4 fold higher than otherwise obtained under fully optimized CE-SDS conditions (Figure 2).

CONCLUDING REMARKS SDS has long been the default detergent used for size-separation electrophoresis since the inception of PAGE (6), with some studies attempting to identify superior alternatives (18,26-28). Otzen reviewed recent efforts and concluded that SDS remains the best detergent for PAGE (7). This work underscores how alternative detergents can be of potential use to improve CGE resolving power of some proteins and related impurities. SHS is an example of one of these alternatives, with its effect likely induced by specific thermophilic/hydrophobic properties of select proteins. We postulate that similar improvements would be observed by SDS-PAGE using SHS with RTP-1 and RTP-2.

ACKNOWLEDGMENT The authors wish to thank Dr. Jeff Meyer and Devi Visone from Zymogenetics, a subsidiary of BristolMyers Squibb, Seattle, WA for supplying us with RTP-2 material and for helping to confirm the applicability of the SHS gel to RTP-2, and to Dr. Ming Zeng from Bristol-Myers Squibb, New Brunswick, 10 ACS Paragon Plus Environment

Page 11 of 23

195

1 2 3 196 4 5 197 6 7 198 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

NJ for participating in the initial assessment of the SHS gel.

We would also like to thank Drs. Julia

Ding and Roberto Rodriguez for their critical review of the manuscript.

REFERENCES

1.

Chirino, A. J., and Mire-Sluis, A. Nat Biotechnol. 2004, 22, 1383-1391

2.

Zhao, S. S., and Chen, D. D. Electrophoresis 2014, 35, 96-108

3.

Rustandi, R. R., Washabaugh, M. W., and Wang, Y. Electrophoresis 2008, 29, 3612-3620

4.

Chen, T., Chen, Y., Stella, C., Medley, C. D., Gruenhagen, J. A., and Zhang, K. J. Chromatogr. B 2016, 1032, 39-50

5.

Nunally, B., Park, S. S., Patel, K., Hong, M., Zhang, X., Wang, S.-X., Rener, B., Reed-Bogan, A., Salas-Solano, O., Lau, W., Girard, M., H., C., Garcia-Canas, V., Cheng, K. C., Zeng, M., Ruesch, M., R., F., Jochheim, C., Natarajan, K., Jessop, K., Saeed, M., Moffatt, F., Madren, S., Thiam, S., and Altria, K. Chromatographia 2006, 64, 359-368

6.

Laemmli, U. K. Nature 1970, 227, 680-685

7.

Otzen, D. E. Curr. Opin. Colloid Interface Sci. 2015, 20, 161-169

8.

Reynolds, J. A., and Tanford, C. Proc. Natl. Acad. Sci. USA 1970, 66, 1002-1007

9.

Guttman, A., and Nolan, J. Anal. Biochem. 1994, 221, 285 - 289

10.

Shaw, B. F., Schneider, G. F., Arthanari, H., Narovlyansky, M., Moustakas, D., Durazo, A., Wagner, G., and Whitesides, G. M. J. Am. Chem. Soc. 2011, 133, 17681-17695

11.

Williams, J. G., and Gratzer, W. B. J. Chromatogr. 1971, 57, 121-125

12.

Otzen, D. E., Christiansen, L., and Schulein, M. Protein Sci. 1999, 8, 1878-1887

13.

Dolnik, V., and Gurske, W. A. Electrophoresis 2011, 32, 2893-2897

14.

Shaw, B. F., Schneider, G. F., and Whitesides, G. M. J. Am. Chem. Soc. 2012, 134, 18739-18745

15.

Lipovsek, D. Protein Eng Des Sel. 2011, 24, 3-9

16.

Eswar, N., Webb, B., Marti-Renom, M. A., Madhusudhan, M. S., Eramian, D., Shen, M.-Y., Pieper, U., and Sali, A. Curr. Protoc. Bioinform. 2006, Chapter 5, Unit 5.6

17.

Baker, N. A., Sept, D., Joseph S., Holst, M.J. and McCammon, J.A. Proc. Natl. Acad. Sci. USA 2001, 98, 10037-10041 11 ACS Paragon Plus Environment

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 23

18.

Ospinal-Jimenez, M., and Pozzo, D. Langmuir 2011, 27, 928-935

19.

Manning, M., and Colon, W. Biochemistry 2004, 43, 11248-11254

20.

Banerji, A., and Ghosh, I. PLoS One 2009, 4, e7361

21.

Cunningham, E. L., Jaswal, S. S., Sohl, J. L., and Agard, D. A. Proc. Natl. Acad. Sci. USA 1999, 96, 11008-11014

22.

Deep, S., and Ahluwalia, J. C. Phys. Chem. Chem. Phys. 2001, 3, 4583-4591

23.

Evans, H. C. J. Chem. Soc. 1956, 0, 579-586

24.

Voynov, V., Chennamsetty, N., Kayser, V., Helk, B., and Trout, B. L. MAbs 2009, 1, 580-582

25.

Brader, M. L., Estey, T., Bai, S., Alston, R. W., Lucas, K. K., Lantz, S., Landsman, P., and Maloney, K. M. Molecular Pharmaceutics 2015, 12, 1005-1017

26.

Brown, E. G. Anal. Biochemistry 1988, 174, 337-348

27.

Lopez, M. F., Patton, W. F., Utterback, B. L., Chung-Welch, N., Barry, P., Skea, W.M., and Cambria, R. P. Anal. Biochemistry 1991, 199, 35-44

28.

Ospinal-Jimenez, M., and Pozzo, D. Langmuir 2014, 30, 1351-1360

ACS Paragon Plus Environment

12

Page 13 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

TABLES Table 1. RTP-1 Peak Separation Efficiency (PSE) Values Obtained Using Various Gel Buffer Detergents Detergent in the Gel Buff- Resolution Between Main Peak Theoretical er Solution (0.2%)a Main and IP1 Plates SUS (C11) 1.18 2530.0 SDS (C12) 0.77 1825.7 STS (C14) 1.63 6083.5 SHS (C16) 1.80 11815.9 a The RTP-1 sample solution contained the corresponding detergent

ACS Paragon Plus Environment

13

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 23

Table 2. DSC functions obtained from adding various concentrations of either SDS or SHS to RTP-1 Detergent

SDS

SHS

a, b c

[Detergent], mM None

Tm1 (°C)a 68.9

Tm2 (°C) b 77.1

E1, ΔH1 (cal/mol)(105) c 3.20

E2, ΔH2 (cal/mol)(105) d 1.68

0.050

68.9

77.1

3.35

1.81

0.10

69.1

77.1

3.87

2.03

1.0

63.9

77.1

1.29

2.17

8.0

50.4

74.7

0.53

1.16

None

68.9

77.1

3.20

1.68

0.0030

68.8

77.0

3.20

1.88

0.013

66.7

77.1

2.01

2.18

0.50

60.6

77.2

0.45

1.17

2.0

58.7

72.4

0.24

0.87

Comparable drop in Tm with [detergent] regardless of detergent type

Comparable drop in ∆H1 with [detergent] regardless of detergent type (Figure 6C)

d

∆H2 dropped more dramatically with SHS after reaching a particular concentration (0.1 mM SDS and 0.013 mM SHS) (Figure 6D)

ACS Paragon Plus Environment

14

Page 15 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

FIGURES

Figure 1. CGE Electropherograms of RTP-1 comparing results with or without 0.2% sodium hexadecyl sulfate (SHS) added to the gel buffer solution. Images were cropped to show only the regions of interest. Top view: high level overlay showing the relative differences in peak separation efficiency (PSE). Lower views: baseline zoomed-in views highlighting the SHS impact on IP1 resolution from the main RTP-1 peak

ACS Paragon Plus Environment

15

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 23

Figure 2. Impact of SHS on the RTP-1 purity method range (linearity). A) Apparent relative proportion of IP1 present with or without SHS in the sieving gel buffer solution. B) IP1 area signal linearity comparison with or without SHS. Note the consistency across the tested concentration range with SHS present. Combined, the data show that without SHS the assay range was limited to peak area signals ≤ 10k relative to ≥ 30k when SHS was used.

ACS Paragon Plus Environment

16

Page 17 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Figure 3. Electropherograms showing the impact of various detergents on RTP-1 PSE (narrowed into the relevant region with a slight offset). Inset: Structures of the detergents added to the gel buffer solutions. The injected RTP-1 sample and gel buffer contained only the detergent noted above the electropherogram. The impact of gel buffer detergent composition on main peak plate count and resolution between the main peak and IP1 are listed in Table 1.

ACS Paragon Plus Environment

17

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 23

1.0% SHS 0.2% SHS 4% SDS 2% SDS 1% SDS 0.2% SDS 0.0

5.0

10.0

15.0

Main Peak Plate Count (x10^3)

Figure 4. Effect of varying gel buffer SDS or SHS concentration on RTP-1 main peak plate count. The effect of SDS on plate count reached near saturation at concentrations > 2.0%

ACS Paragon Plus Environment

18

Page 19 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Figure 5. Charge surface profile of the Adnectin portion of RTP-1. Red and blue indicate negative and positive electrostatic charge, respectively. A and B show opposite surface exposed views. Note the high degree of negative charge on the surface shown in A, which may be a barrier to the binding of detergents except for those with longer hydrophobic tails like SHS which can better establish an energetically-favorable interaction with the hydrophobic core of the protein to initiate unfolding.

ACS Paragon Plus Environment

19

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 23

Figure 6. SDS:RTP-1 and SHS:RTP-1 Differential Scanning Calorimetry (DSC) profile comparisons. A) Impact of varying the SDS concentration on the RTP-1 DSC profile, and B) the impact of varying the SHS concentration. Two endothermal profiles are clearly visible, E1 and E2, representing the Fc and Adnectin domains respectively, which were assessed for denaturation temperatures (Tm1 and Tm2) and enthalpy (∆H1 and ∆H2). Values for these functions are listed in Table 2. Plots of the enthalpy changes of the two domains against detergent concentration are shown in C and D.

ACS Paragon Plus Environment

20

Page 21 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Figure 7. CGE profiles of other proteins obtained using SDS and SHS gel buffer solutions: mAbs RTP-2 (A) and RTP-3 (B). The light chain and heavy chain peaks are labeled LC and HC respectively. Black and red traces are electropherograms obtained from SDS and SHS gel buffer solutions respectively.

ACS Paragon Plus Environment

21

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 23

Figure 8. Comparison of RTP-1 electropherograms obtained with SDS (A), SHS (B) or both (C) in the gel buffer. (C) Inset: Close-up comparison of the 10 kDa I.S. under all three conditions. Note that the addition of SDS to the SHS gel buffer did not significantly impact the PSE profile of RTP-1 (compare panels B and C).

ACS Paragon Plus Environment

22

Page 23 of 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

For Table of Contents Only

ACS Paragon Plus Environment

23