HACH made a simple spectrophotometer into a whole analytical system
With the Hach DR/2 you will be able to: • Read concentration directly on the meter scale. The DR/2 comes with 62 different meter scales. • Hach's dependable, premeasured reagents match DR/2 meter scales. • Versatile! Read % Τ for "standard methods" or make your own meter scales. Open up a world of simplified test methods by owning the Hach DR/2 Spectrophotometer!
FREE:
With the purchase of your D R / 2 you will receive a 300 page book of simplified water test methods. An invaluable aid for anyone w h o must test water.
for further info:
HACH COMPANY P.O. Box 3 8 9 Loveland, CO 8 0 5 3 7
CALLTOLL FREE 800-525-5940
CIRCLE 96 ON READER SERVICE CARD
New β/R Still Saves €nerg^! *
Colorimeters Brinkmann Dipping Probe Colorimeters (available in four models) come with fiber optic bundles to read transmittance, absorbance, or concentration. The fiber optic probe tip is dipped di rectly into the sample solution. Read ings may be taken in luminous or nonluminous environments. Applications in clude colorimetric titrations, turbidity measurements, and in-line monitoring. Model PC/700 features an analog scale and a single slide-in filter; model PC/ 7 0 1 , an analog scale and multiple filter wheel; model PC/800, a digital readout and single slide-in filter; and model PC/801, a digital readout multiple filter wheel. Brinkmann Instruments, Inc. 409
Portable Digital Pyrometer with Thermocouple Switch Acu-therm Digital Portable Pyrometers and Thermocouple Switches measure and monitor temperatures of multiple thermocouples. They are made in 5, 10, or 20 switch positions and eight models with accuracies and repeatabilities of 1 ° F from - 1 0 0 to 1000 °F. Overall range is - 1 2 0 to 2000 ° F with 0.25% accuracy of reading. Features include 1/3 s response, peak hold with memo ry, one 9-V transistor battery, and sepa rate battery compartment. They are available in K, J, or Ε thermocouple cal ibrations. Weighs 2 lb. 14 oz. Electronic Development Laboratories, Inc. 412
! 1
γη
ij
New Products
'Λ
î|
The 40T Teflon or Monel Thirty Plate Spinning Bond Still with Over Temp Safety Shutdown. 6/R Instruments announces a newly devel oped spinning bond type distillation column that Is versa ti le enough to b e used over a very ujlde temperature ronge of 0°C to 180°C urfth
ι
il
.
[ /I
m^_z— ι
the teflon band. Applications under 180 C with the teflon bond are organic synthesis. HPLC grade purification, solvent recovery etc. UJith the metol mesh bond above 180°C Include crude oil samples, bitumen hl-temp. samples. etc. Vacuum operation to as low as .5Hg.
Write for features and technical data to:
*
B/R Instrument Corporation eox7.Posodeno.M