Subscriber access provided by WEBSTER UNIV
Remediation and Control Technologies
Rapid Aerobic Inactivation and Facile Removal of Escherichia coli with Amorphous Zero-valent Iron Microspheres: Indispensable Roles of Reactive Oxygen Species and Iron Corrosion Products Hongwei Sun, Jian Wang, Yao Jiang, Wenjuan Shen, Falong Jia, Shaohui Wang, Xiaomei Liao, and Lizhi Zhang Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.8b06499 • Publication Date (Web): 28 Feb 2019 Downloaded from http://pubs.acs.org on February 28, 2019
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 35
Environmental Science & Technology
1
Rapid Aerobic Inactivation and Facile Removal of Escherichia
2
coli
3
Indispensable Roles of Reactive Oxygen Species and Iron
4
Corrosion Products
5
Hongwei Sun†, Jian Wang§, Yao Jiang§, Wenjuan Shen†, Falong Jia†,*, Shaohui Wang§, Xiaomei
6
Liao§,*, Lizhi Zhang†,*
7
†
8
Environmental & Applied Chemistry, College of Chemistry, Central China Normal University,
9
Wuhan 430079, P. R. China
with
Amorphous
Zero-valent
Iron
Microspheres:
Key Laboratory of Pesticide & Chemical Biology of Ministry of Education, Institute of
10
§
11
China Normal University, Wuhan 430079, P. R. China
Hubei Key Lab of Genetic Regulation and Integrative Biology, School of Life Sciences, Central
12 13
* To whom correspondence should be addressed.
14
Fax: +86 027 67867535; E-mail:
[email protected]. (F. J.)
15
Fax: +86 027 67861936; E-mail:
[email protected]. (X. L.)
16
Fax: +86 027 67867535; E-mail:
[email protected]. (L. Z.)
17
1
ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 35
18
ABSTRACT: Zero valent iron (ZVI) is recently regarded as a promising alternative for water
19
disinfection, but still suffers from low efficiency. Herein we demonstrate that amorphous zero valent
20
iron microspheres (A-mZVI) exhibit both higher inactivation rate and physical removal efficiency
21
for the disinfection of Escherichia coli (E. coli) than conventional crystalline nanoscale ZVI
22
(C-nZVI) under aerobic condition. The enhanced E. coli inactivation performance of A-mZVI was
23
mainly attributed to more reactive oxygen species (ROSs), especially free •OH, generated by the
24
accelerated iron dissolution and molecular oxygen activation in bulk solution. In contrast, C-nZVI
25
preferred to produce surface bound •OH, and its bactericidal ability was thus hampered by the
26
limited physical contact between C-nZVI and E. coli. More importantly, hydrolysis of dissolved iron
27
released from A-mZVI produced plenty of loose FeOOH to wrap E. coli, increasing the dysfunction
28
of E. coli membrane. Meanwhile, this hydrolysis process lowered the stability of E. coli colloid and
29
caused its rapid coagulation and sedimentation, favoring its physical removal. These findings clarify
30
the indispensable roles of ROSs and iron corrosion products during the ZVI disinfection, and also
31
provide a promising disinfection material for water treatment.
32 33
Keywords: Amorphous zero valent iron; Disinfection; E. coli; Reactive oxygen species; Physical
34
removal;
35 36
INTRODUCTION
37
Over the past decades, nanoscale zero-valent iron (nZVI) has been widely used to remove various
38
environmental pollutants, including heavy metals,1, 2 halogenated organics and nitroaromatics,3-5 etc,
39
owing to its high redox activity, facile synthesis and environmental benignancy.6-8 Recently, nZVI
40
was also reported to inactivate a broad spectrum of microbes such as virus, coliphage and bacteria, 2
ACS Paragon Plus Environment
Page 3 of 35
Environmental Science & Technology
41
making it a promising antimicrobial agent for water disinfection.9-11 In comparison with chlorine,
42
nZVI is attractive due to free of carcinogenic disinfection byproducts (DBPs) such as
43
trihalomethanes (THMs), haloacetic acids (HAAs), bromate and chlorite, which are listed as primary
44
contaminants in drinking water by the United States Environmental Protection Agency (USEPA),
45
European Union and World Health Organization (WHO). Meanwhile, nZVI disinfection is capable
46
of removing co-existing contaminants like heavy metals and organic pollutants simultaneously,
47
which is advantageous over chlorination especially in the scenario of wastewater disinfection, where
48
large amounts of pollutants are present. These pollutants might act as precursors of DBPs and must
49
be removed in advance in the case of chlorination, which would increase the operation cost.12,
50
More importantly, the concomitant physical removal of bacteria from water along with inactivation
51
through magnetic separation,14 was strikingly advantageous for practical disinfection by nZVI,
52
because this physical removal process could reduce the chemical oxygen demand (COD) of water by
53
removing the debris of inactivated microbes, and eliminate the risk from regrowth of inactivated
54
bacteria and potential spread of antibiotic resistance genes through horizontal gene transfer.15-18 In
55
addition, nZVI is easier for handling during transport, storage and deployment than chlorine,
56
therefore benefits its application in the disinfection of non-central water supply, and point-of-use
57
water purification.19
13
58
Despite its merits, the disinfection efficiency of nZVI was still inadequate for practical
59
application, especially under aerobic conditions. Therefore, relatively high doses were required to
60
achieve satisfactory disinfection effects, which might improve cost and cause iron sludge.20, 21 It was
61
reported that the aerobic inactivation of microorganism by nZVI mainly involved the generation of
62
reactive oxygen species (ROSs) via oxygenation of nZVI, and the direct physical disruption of cell
63
membrane components by adhered nZVI particles.9,
22
Normally, the oxygenation of nZVI would 3
ACS Paragon Plus Environment
Environmental Science & Technology
Page 4 of 35
64
produce surface oxide layers, which subsequently passivated nZVI and decelerated the further
65
outward electron transfer from Fe0 core to the oxide surface for activation of oxygen and production
66
of ROSs.7, 23 In addition, easy aggregation of nZVI particles, which was driven by electrostatic and
67
magnetic attractions, resulted in poor dispersibility of nZVI and less adhesion onto cells.24 Thus,
68
these two reasons accounted for the unsatisfactory disinfection reactivity of nZVI. Although doping
69
nZVI with precious metals such as Pt and Pd could avoid the unsatisfactory corrosion of iron core
70
and accelerate outward electron transfer through galvanic mechanism,25, 26 the high cost of precious
71
metals disfavored their field application. Surface coating with polymeric stabilizers such as starch
72
and cellulose was a common strategy to improve the dispersion and mobility of nZVI,27, 28 but was
73
always faced with a trade-off between the stability and reactivity of nZVI, and the decreased
74
bactericidal effect after polymer coating.29-32 Obviously, it is vital to develop new strategies to
75
improve the disinfection performance of nZVI.
76
In 2005, Lowry et al. investigated the influence of nZVI annealing treatment on its catalyzed
77
reductive trichloroethylene (TCE) transformation with H2. They found that poorly ordered pristine
78
nZVI could activate H2 to reduce TCE to ethane, but annealed nZVI of good crystallinity could not.
79
Meanwhile, the oxidative dissolution of nZVI was also retarded after annealing treatment.33 Later,
80
Nurmi and his coworkers revealed that nZVI, being prepared by borohydride reduction, was poorly
81
ordered, but outperformed its crystalline counterpart prepared through thermal reduction of goethite
82
with H2, on reducing pollutants like benzoquinone and CCl4.34 Moreover, Wang et al. demonstrated
83
that the recrystallization of aged nZVI was responsible for its activity loss of bromate reduction.35
84
On the basis of these results, we proposed that the disordered structure of nZVI might benefit the
85
electron donating capacity of iron core, and for the first time prepared amorphous zero valent iron
86
microspheres (A-mZVI) through Fe(II) reduction with borohydride in the presence of 4
ACS Paragon Plus Environment
Page 5 of 35
Environmental Science & Technology
87
ethylenediamine (EDA). However, it is still unknown how the amorphous structure will affect the
88
ROSs generation and disinfection performances of ZVI, which is crucial for us to clarify the
89
pollutant removal ability of A-mZVI.
90
In this study, we compared the inactivation and physical removal performances of A-mZVI and
91
zero-valent iron nanoparticles (C-nZVI) toward a typical Gram-negative bacterium Escherichia coli
92
(E. coli) under aerobic condition, aiming to unravel the aerobic disinfection mechanism of A-mZVI
93
through investigating the production and evolution of ROSs in the A-mZVI/air and C-nZVI/air
94
systems, and clarified the effects of dissolution processes and corrosion products of A-mZVI and
95
C-nZVI on the inactivation and physical removal of E. coli.
96 97
EXPERIMENTAL SECTION
98
Synthesis and Characterization of ZVI. To prepare A-mZVI, 75 mL of EDA (0.9 mol/L) was
99
added into 300 mL of 0.075 mol/L FeCl2 aqueous solution, after thoroughly mixed for 3 min under
100
stirring, 75 mL of 1.6 mol/L NaBH4 aqueous solution was introduced. The reduction process was
101
finished in 25 min until no obvious bubble emission was observed. The obtained black precipitate
102
was collected, washed with deionized water and absolute ethanol for 3 times, and dried under
103
infrared lamp. All these procedures were conducted under argon gas protection to avoid oxidation of
104
iron. C-nZVI was prepared with similar procedures without adding EDA. The as-prepared ZVI
105
samples were characterized with scanning electron microscopy (SEM, TESCAN MIRA 3, Czech)
106
and X-ray diffraction (XRD, D8 Advance, Cu Kα radiation, λ = 0.15418 nm, Bruker, Germany). The
107
content of nitrogen in the synthesized A-mZVI and C-nZVI was measured by elementary analysis
108
(vario Micro cube, Elementar) to check the residue of EDA, and the release of EDA from A-mZVI
109
during use was evaluated by measuring total nitrogen (TN) concentrations with a TOC/TNb 5
ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 35
110
Analyzer (vario TOC select, Elementar). Fe0 content was quantified by acid digestion and hydrogen
111
gas production assay.33 Specific surface area (SSA) was determined by Brunauer-Emmett-Teller
112
(BET) method with a N2 adsorption system (Micromeritics Tristar 3000). Details of characterization
113
methods are provided in Supporting Information (SI).
114
Disinfection Experiments. E. coli strain BW25113 was purchased from Coli Genetic Stock Center
115
of Yale University, USA. To prepare the bacterial suspension, E. coli was inoculated into 50 mL of
116
autoclaved nutrient broth and incubated overnight, then the bacteria were harvested and washed. The
117
pellet was resuspended in 0.85% NaCl and the optical density at 670 nm (OD670 nm) was adjusted to
118
0.06. ZVI at predetermined doses were added into 50 mL of the obtained bacterial suspension and
119
incubated at 250 rpm and 37 ℃ in an orbital shaker. To determine the survival ratio and physical
120
removal efficiency of E. coli, 5 mL of the slurry samples were collected at regular intervals and
121
magnetically separated to obtain the supernatant, which was subsequently stained with
122
LIVE/DEADTM BacLightTM Bacterial Viability Kit and analyzed with flow cytometry
123
(LSRFortessaTM, BD, USA). This Kit contains two fluorescent nucleic acids dyes, namely SYTOTM
124
9 and propidium iodide (PI). SYTOTM 9 is cell membrane permeable and can bind with bacterial
125
DNA to emit green fluorescence (530 nm) when excited at 488 nm. PI can quench SYTOTM 9 due to
126
its higher DNA binding affinity to generate red fluorescence (excitation wavelength of 488 nm and
127
emission wavelength of 630 nm). Nevertheless, PI is not permeable to intact membrane, and thus the
128
live cells with intact membrane can only be stained green by SYTOTM 9, and dead cells with
129
disturbed membrane can be stained red by PI. The numbers of fluorescent particles (E. coli cells) in
130
200 μL samples were recorded by volumetric counting hardware. In the two-parameter dot plots of
131
PI versus SYTOTM 9, four clusters could be distinguished by quadrants gate (Q1-4), which were
6
ACS Paragon Plus Environment
Page 7 of 35
Environmental Science & Technology
132
ascribed to dead, injured, live cells and negative background signals (SI Figure S1), respectively.
133
The survival ratio and removal efficiency of E. coli were calculated according to Equation 1-3:
134
Survival ratio = N3/(N1+N2+N3)
(1)
135
C = (N1+N2+N3) / 200 μL
(2)
136
Removal efficiency (%) = (C0-Ct)/C0
(3)
137
where N1-3 were the cell numbers in Q1-3, respectively, and (N1+N2+N3) referred to the total cell
138
numbers. C0 and Ct were the bacterial concentrations in the supernatant at time 0 and t, respectively.
139
E. coli inactivation efficiency was also monitored by the heterotrophic plate count (HPC) method at
140
a predetermined initial E. coli concentration of 1×106 colony forming unit per milliliter (CFU/mL) to
141
facilitate the comparison of A-mZVI with other ZVI in the literature. Details of the method were
142
provided in SI.
143
The survival states of the cells in sediment samples were determined by a fluorescent
144
microscope (EVOS FL Auto, Life Technologies Corporation) after staining with LIVE/DEADTM
145
Kit. Images of green (SYTOTM 9) and red (PI) fluorescent channels were captured simultaneously
146
for the same sample, and their merged images were used to depict the viable states of E. coli. The
147
intensities of green and red fluorescence were also integrated with ImageJ,36 and their ratio
148
(Green/Red) was used as an index of the E. coli viability in the sediments. Note that the Green/Red
149
ratio of E. coli cells at 0 min could not be calculated without red fluorescence signals. The ratio
150
could only be obtained after E. coli cells were inactivated by ZVI and the bacterial membrane
151
became disturbed and permeable to PI. Details of the method were described in the SI.
152
Analytical Methods. The mixtures after ZVI disinfection were left to settle for different durations,
153
and the turbidity of the supernatant was measured with a portable turbidimeter (2100Q, HACH).
154
Concentrations of dissolved Fe2+ and Fe3+ were determined by the 1,10-phenanthroline colorimetric 7
ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 35
155
method.37
156
5,5-dimethyl-1-pyrroline N-oxide (DMPO) were employed to detect •OH and •O2- with a JES FA
157
200 X-band spectrometer (JEOL, Japan). H2O2 concentration was tested with a modified
158
p-hydroxyphenylacetic acid (POHPAA) fluorescent method.38 Intracellular ROSs concentration was
159
measured fluorescently by utilizing 2,7-Dichlorodihydrofluorescein diacetate (DCFH-DA) as a
160
probe.39 Catalase and superoxide dismutase (SOD) activities were measured using Catalase Assay
161
Kit (S0051, Beyotime Institute of Biotechnology, China) and Superoxide Dismutase Assay Kit
162
(S0101, Beyotime Institute of Biotechnology), respectively. Membrane potential of E. coli was
163
measured with Rhodamine 123 (Rh123) probing method,22 and adenosine triphosphate (ATP)
164
production by E. coli was assayed by a BacTiter-GloTM Microbial Cell Viability Assay Kit (G8230,
165
Promega Corporation, USA). The sample preparation protocols of E. coli for SEM and transmission
166
electron microscopy (TEM, JEOL-2010, 200 kV) characterization were provided in SI. Magnetic
167
hysteresis loops of the oxidized ZVI were measured with a vibrating sample magnetometer (VSM) at
168
ambient temperature within the magnetic field of ± 10,000 Oe. Particle size distribution of ZVI-E.
169
coli suspension was measured by dynamic light scattering (Zetasizer Nano, Malvern), as described
170
in SI.
Electron
spin
resonance
(ESR)
spectra
and
the
radical
spin
trapper
171 172
RESULTS AND DISCUSSION
173
Synthesis and Characterization of ZVI. As shown in the SEM images, the as-synthesized C-nZVI
174
contained chains or aggregates assembled by spheres of 50-200 nm (Figure 1a), consistent with our
175
previous study.6 Differently, A-mZVI was composed of spheres in size of 0.8-1.2 μm (Figure 1b and
176
1c). XRD pattern suggested C-nZVI exhibited an obvious diffraction peak around 2θ value of 44.5°,
177
corresponding to α-Fe0 (JCPDS No. 87-722), which was the typical XRD pattern of nZVI produced 8
ACS Paragon Plus Environment
Page 9 of 35
Environmental Science & Technology
178
by NaBH4 reduction in solution.40,
179
A-mZVI, indicating the formation of amorphous structure of ZVI in the presence of EDA (Figure
180
1d). This amorphous nature of A-mZVI might benefit the production of ROSs and aerobic
181
disinfection of E. coli. The contents of N, C, H in C-nZVI were 0%, 0.47% and 0.48%, which were
182
0.90%, 1.16% and 0.55% in A-mZVI, respectively (SI Table S1). This comparison suggested the
183
EDA content in the as-prepared A-mZVI was rather low, as the washing with deionized water and
184
ethanol might remove most of EDA residue. Subsequently, the release of EDA from A-mZVI during
185
disinfection was evaluated. A-mZVI were subjected to aerobic corrosion for 1 h and then filtered.
186
The TN concentrations of filtrates were found to be 1.5, 1.8 and 3.2 mg/L for A-mZVI dosage of
187
200, 500 and 1000 mg/L, respectively (SI Figure S2). These values were much lower than the US
188
national criterions of nitrate nitrogen (N) and total ammonia nitrogen (TAN), which were 10 mg/L
189
for domestic water supply and 17 mg/L for fresh water, respectively.42, 43 TN concentrations of 1.5,
190
1.8 and 3.2 mg/L corresponded to EDA concentrations of 3.2, 3.9 and 6.9 mg/L, respectively,
191
assuming that all the nitrogen elements were originated from EDA. Since there is no guideline
192
concentration of EDA in water available, the lowest No Observed Adverse Effect Level (NOAEL, 9
193
mg/kg body weight per day) obtained from rat experiments was used to evaluate the toxicity and
194
overall risk of EDA oral intake, as recommended by WHO.44 The estimated daily intake (EDI) of
195
EDA through water consumption was calculated according to equation 4:45
196
41
However, no obvious diffraction peak was acquired for
EDI = Ci × CR / BW
(4)
197
where Ci is the concentration of EDA in water, CR represents the consumption rate of drinking
198
water (2 L/day), and BW stands for the average body weight (70 kg for adults). The EDIs were 0.09,
199
0.1 and 0.2 mg/kg body weight per day at A-mZVI dose of 200, 500 and 1000 mg/L, respectively,
200
which were far less than the NOAEL of 9 mg/kg body weight per day recommended by WHO. 9
ACS Paragon Plus Environment
Environmental Science & Technology
Page 10 of 35
201
Therefore, the toxicity and risk induced by the EDA residual in water were negligible.
202
Inactivation and Physical Removal of E. coli by ZVI. The as-prepared ZVI samples were then
203
used for the disinfection of E. coli under aerobic condition. The initial concentration of E. coli was
204
determined to be approximately 107 cells/mL by using flow cytometry (Figure 2a). In the
205
supernatant samples after C-nZVI disinfection, both the total and viable E. coli concentrations
206
decreased steadily, which were 8.4×105 and 5×105 cells/mL after 60 min, respectively. Impressively,
207
A-mZVI induced much sharper concentration decrease of total and live cells in the supernatant,
208
which were respectively down to 5×105 and 2×105 cells/mL after only 5 min (Figure 2a). The
209
survival ratios and removal efficiencies of E. coli were calculated according to Eqs 1-3. We found
210
that A-mZVI inactivated E. coli much more rapidly, and only 18% of the cells remained viable after
211
60 min, much lower than that (53%) of C-nZVI treatment (Figure 2b). More importantly, A-mZVI
212
also showed remarkably better physical removal performance. The removal efficiency of E. coli in
213
the C-nZVI system increased gradually to 95% after 1 h, but it just took 5 min for A-mZVI to reach
214
a comparable removal efficiency (Figure 2c).
215
Since the physical removal effect of ZVI would precipitate most of E. coli cells into the
216
sediment, it is essential to understand the fate of E. coli in this phase. Nonetheless, the survival status
217
of bacteria physically removed by ZVI has never been studied in previous reports.14, 46 Herein, we
218
utilized fluorescent microscope to check the viability of E. coli in the sediment samples, and found
219
that these cells were inactivated gradually, following similar trends with those in the supernatant (SI
220
Figure S3). As an index of E. coli viability, the fluorescent intensity ratio of Green/Red decreased
221
steadily from 4.82 at 5 min to 0.67 at 60 min in the C-nZVI/E. coli system, whereas the ratio was
222
1.24 after 5 min and further reduced to 0.46 at 40 min in the A-mZVI/E. coli system (Figure 2d).
223
This comparison confirmed that A-mZVI could also more efficiently inactivate E. coli in the 10
ACS Paragon Plus Environment
Page 11 of 35
224
Environmental Science & Technology
sediments.
225
The influence of ZVI dose on the inactivation and removal of E. coli was also investigated. As
226
expected, the inactivation of E. coli showed an obvious dose-dependent manner in the range of
227
20-400 mg/L, but A-mZVI exhibited apparent advantage over C-nZVI at identical dosage. For
228
example, virtually complete inactivation of E. coli was achieved at 400 mg/L of A-mZVI, whilst
229
16% of E. coli still survived at the same dose of C-nZVI (Figure 3a). Similar trends were observed in
230
the sediment samples via fluorescent microscopic images (SI Figure S4). The minimum doses of
231
C-nZVI and A-mZVI to physically remove 90% of E. coli from water were 50 and 20 mg/L,
232
respectively. This difference further confirmed the superiority of A-mZVI for physical removal of E.
233
coli (Figure 3b). Moreover, we conducted additional control experiments with crystalline
234
micro-scale zero valent iron (C-mZVI), which was prepared by annealing the A-mZVI at 500 °C for
235
4 h in Ar. SEM images indicated that the size of C-mZVI was in the range of 1-2 μm (SI Figure
236
S5a), similar with that of A-mZVI. As expected, the crystallinity of C-mZVI greatly improved after
237
annealing treatment, as revealed by the sharp diffraction peak at 2θ = 45° (JCPDS No. 87-722) in the
238
XRD pattern (SI Figure S5b). We thus compared the E. coli inactivation performance of A-mZVI,
239
C-nZVI and C-mZVI, and found that the disinfection capacity decreased following the order of
240
A-mZVI > C-nZVI > C-mZVI (SI Figure S5c). As both C-nZVI and C-mZVI were crystallized, the
241
lower disinfection activity of C-mZVI with larger particle size was consistent with previous reports
242
about the size effect on bactericidal capacity of ZVI.47 Although A-mZVI and C-mZVI had similar
243
particle size, C-mZVI of crystalline nature possessed a dramatically reduced antibacterial activity.
244
Therefore, we concluded that the improved disinfection performance of A-mZVI was arisen from its
245
amorphous structure, rather than the size effect. Moreover, the Fe0 content of A-mZVI (67%) was
246
only slightly higher than that (60%) of C-nZVI (SI Table S1), which further confirmed that the 11
ACS Paragon Plus Environment
Environmental Science & Technology
Page 12 of 35
247
improved E. coli inactivation of A-mZVI was not related to the Fe0 content, but to the amorphous
248
structure.
249
The E. coli inactivation efficiency of A-mZVI was also compared with previous reports. Since
250
most of the literatures determined the inactivation efficiencies of E. coli by using the HPC method
251
with initial E. coli concentration of 1×106 CFU/mL, we conducted similar experiments by using
252
A-mZVI for better comparison. The inactivation efficiency (log (N0/N)) was 2.4 ± 0.2 after treated
253
with 100 mg/L of A-mZVI for 60 min under aerobic condition. After settling for 0.5 h, the E. coli
254
concentrations in the supernatant decreased by 3.8 ± 0.04 log (SI Table S2). This inactivation
255
efficiency of A-mZVI was higher than those of many ZVI reported in the literature, including nZVI,
256
electrosprayed nZVI, commercial Nanofer 25 (Nano Iron s.r.o., Czech Republic), commercial
257
reactive nanoscale iron particles (RNIP, Toda Kogyo Corp.), and microscale iron powder.14, 21, 29, 47, 48
258
The cost of the A-mZVI synthesized was estimated to be ca. 0.6 USD/g (SI Table S3), which was
259
relatively high because the synthesis of A-mZVI was conducted in laboratory scale and the reagents
260
used were supplied in small packages and of high purity (AR). Nevertheless, the price of A-mZVI
261
could be significantly decreased in industrial production by scaling-up the fabrication and by
262
adopting much cheaper reagents of technical grade to meet the need of practical disinfection.
263
Subsequently, the turbidity of the ZVI treated water was also monitored, which were 158.0 and
264
88.6 nephelometric turbidity unit (NTU) for A-mZVI and C-nZVI right after the batch experiments.
265
The turbidity of the supernatant in the A-mZVI system decreased sharply to 19.2 NTU after only 0.5
266
h of settling, much faster than that (45.4 NTU) in the C-nZVI system. The turbidity further
267
decreased with prolonged settling duration (SI Figure S6a). Interestingly, a linear relationship was
268
revealed between Ln (turbidityt/turbidity0) and settling time, where turbidityt and turbidity0 were the
269
turbidity at settling time t and 0 h, respectively (SI Figure S6b). Therefore, the turbidity of effluent 12
ACS Paragon Plus Environment
Page 13 of 35
Environmental Science & Technology
270
after A-mZVI disinfection can be controlled by tuning the settling duration according to the purpose
271
of application. In the case of wastewater disinfection, the wastewater discharge standard of China
272
(GB 8978-1996) regulates the total suspended solids (TSS) from 20 to 100 mg/L in different
273
scenarios, which corresponds to turbidity values of ca.13-100 NTU according to a general rule of
274
thumb. This suggests that 1 mg/L of TSS approximately equals to 1.0-1.5 NTU of turbidity.49 Then
275
less than 1.3 h of settling after A-mZVI disinfection was required to meet the wastewater discharge
276
standard (13 NTU, SI Figure S6b). In the context of drinking water disinfection, the criteria of
277
turbidity for central water supply and non-central water supply were 1 and 3 NTU, which could be
278
raised to 3 and 5 NTU when the quality of water source or the technical conditions of water
279
purification were limited, according to the drinking water standard of China (GB5749-2006). Then
280
the necessary settling durations were 6.8, 9.7 and 16 h to meet the turbidity standards of 5, 3 and 1
281
NTU, respectively (SI Figure S6b). Therefore, A-mZVI is potentially used for water disinfection
282
with post-disinfection settling process. Alternatively, settling process might be omitted if
283
disinfection be carried out in a flow-through column packed with ZVI.
284
Mechanism of Inactivation. To unravel the mechanism of promoted E. coli inactivation
285
performance of A-mZVI, we first investigated the contribution of various ROSs by scavenging
286
experiments, since ROSs played vital roles in the aerobic inactivation of bacteria by ZVI.9,
287
Intriguingly, the inactivation performance of the two ZVI samples changed in significantly different
288
manners after ROSs quenching. In the C-nZVI/E. coli system, the scavenging effects descended
289
following the order of SOD > catalase > tert-butyl alcohol (TBA), which were used to quench •O2-,
290
H2O2 and •OH, respectively. This trend suggested that •O2- and H2O2 were responsible for the
291
inactivation of E. coli, whereas •OH was less important, which was consistent with previous
292
reports.9, 47 As for the A-mZVI/E. coli system, the addition of SOD, catalase and TBA resulted in
50
13
ACS Paragon Plus Environment
Environmental Science & Technology
Page 14 of 35
293
similar changes of survival ratio, highlighting the indispensable role of •OH for the E. coli
294
disinfection (Figure 3c and SI Figure S7), and also explaining the better bactericidal performance
295
of A-mZVI, because •OH is a much stronger oxidant than •O2- and H2O2.
296 297
Subsequently, we attempted to clarify how the amorphous structure altered ROSs production of ZVI. Generally, the evolution of ROSs by ZVI oxygenation could be described by Eqs 5-11:8, 51, 52
298
Fe0 → ≡Fe2+ + 2e-
(5)
299
≡Fe2+ → Fe2+
(6)
300
O2 + 2e- + 2H+ → H2O2
(7)
301
O2 + e- → •O2-
(8)
302
•O2- + e- + 2H+ → H2O2
(9)
303
≡Fe2+ + H2O2 → ≡Fe3+ + •OHsurface + OH-
(10)
304
Fe2+ + H2O2 → Fe3+ + •OH + OH-
(11)
305
where ≡ indicated surface bound species. As stated above, •OH more contributed to the disinfection
306
in the A-mZVI/E. coli system than in the C-nZVI/E. coli system, whereas •O2- and H2O2 served
307
mainly as the precursors of •OH in the A-mZVI/E. coli system. To clarify the ROSs production
308
processes, we first investigated the dissolution behavior of the two ZVI samples. The dissolution rate
309
of A-mZVI was higher, indicating that A-mZVI possessed stronger electron donating capacity than
310
C-nZVI (Figure 4a). Obviously, this stronger electron donating capacity should facilitate the ROSs
311
production via reduction of O2 by A-mZVI (Eqs 6, 7), which was confirmed by more •O2- generated
312
in the A-mZVI system (SI Figure S8 and Figure 4b). Moreover, more accessible electrons from iron
313
core and dissolved Fe2+ in the A-mZVI system would further accelerate the transformation of •O2-
314
into H2O2 and finally •OH (Eqs 9-11), and thus shorten the lifetime of •O2- and H2O2. Consequently,
315
•O2- and H2O2 would act as intermediates of •OH rather than direct bactericidal agents in the 14
ACS Paragon Plus Environment
Page 15 of 35
Environmental Science & Technology
316
A-mZVI system. To validate this hypothesis, we measured the concentrations of H2O2 and •OH.
317
Although the steady-state H2O2 were not detected due to its rapid in-situ decomposition, the
318
accumulated H2O2 concentrations produced by A-mZVI were higher than C-nZVI (Figure 4c),
319
confirming the enhanced transformation of •O2- into H2O2 by A-mZVI. A-mZVI also showed much
320
faster H2O2 depletion performance (Figure 4d), and the H2O2 decomposition rate constant of
321
A-mZVI was 0.708 min-1, much higher than that (0.109 min-1) of C-nZVI (SI Figure S9). Finally, the
322
•OH levels, as reflected by the ESR intensities of DMPO-OH adduct, were significantly elevated in
323
the A-mZVI system (Figure 4f). These results proved the accelerated transformation of H2O2 into
324
•OH by A-mZVI. The shortened lifetime of •O2- and H2O2 was further supported by the lowered
325
intracellular ROSs levels induced by A-mZVI (Figure 4e), because the limited lifespan rendered it
326
less likely for •O2- and H2O2 to penetrate the cytomembrane into cytoplasm before their
327
transformation, whereas their derivative •OH was also too active and short-lived to enter cells.53
328
As for the C-nZVI system, most of Fe2+ generated by oxidation of Fe0 would be
329
surface-associated rather than dissolved,6, 51 resulting in the decomposition of H2O2 dominantly at
330
the surface of C-nZVI to produce surface-bound •OH (•OHsurface, Eq. 10).54 In such a case, the
331
interaction between •OHsurface and E. coli would largely depend on the physical contact between
332
C-nZVI and cells. However, the poor dispersion of C-nZVI in the disinfection system disfavored the
333
direct contact between C-nZVI and E. coli and thus impeded the attack of •OHsurface to the cells.
334
Whereas in the case of A-mZVI, more Fe2+ was dissolved, resulting in more decomposition of H2O2
335
in the bulk solution to produce free •OH (Eq. 11), which could kill E. coli without the direct contact
336
between A-mZVI and cells. To verify the proposed mechanism, the fractions of •OHsurface among the
337
overall •OH (sum of •OHsurface and free •OH) were further investigated by using DMPO-trapped EPR
338
technique. F- was used to desorb the •OHsurface by forming strong hydrogen bond,55 thus the EPR 15
ACS Paragon Plus Environment
Environmental Science & Technology
Page 16 of 35
339
intensities without F- (I0) represented free •OH levels, and the intensities with F- addition (IF) was
340
attributed to overall •OH levels, assuming that F- could disassociate all the •OHsurface. We defined the
341
•OHsurface fractions as (IF-I0)/IF, and found the •OHsurface fractions (78.7-92.5%) of C-nZVI system
342
was much higher than those (36.1-57.9%) of A-mZVI system (Figure 4f). These results confirmed
343
that C-nZVI was dominated by •OHsurface whereas A-mZVI favored free •OH.
344
The intracellular ROSs did not play important role in E. coli inactivation in the A-mZVI-E. coli
345
system, because most of ROSs were generated and transformed in the extracellular bulk solution to
346
•OH, the predominant bactericidal ROSs. In the scavenging experiments, the scavengers
347
impermeable to the membrane were supposed to scavenge the extracellular ROSs. Therefore, the
348
significant inhibition of disinfection by TBA suggested the indispensable role of extracellular •OH
349
(Figure 3c). Although A-mZVI could inactivate E. coli much faster than C-nZVI, the intracellular
350
ROSs levels in the A-mZVI-E. coli system was much lower than those in the C-nZVI-E. coli system
351
(Figure 4e). In contrast, intracellular ROSs might play relatively more important role in the
352
C-nZVI-E. coli system because of its much higher intracellular ROSs concentrations. The
353
scavenging experiments also indicated the vital roles of extracellular •O2- and H2O2 for E. coli
354
inactivation, but neither •O2- nor H2O2 were efficient for the direct oxidative damage of E. coli cells.
355
Comparatively, •OH is a much stronger oxidant, but the contribution of extracellular •OH was
356
negligible in the C-nZVI-E. coli system because most of •OH were produced in the form of surface
357
associated species and had limited physical contact with E. coli cells. Therefore, it is highly possible
358
that •O2- and H2O2 entered E. coli cells and thus became intracellular •OH to inactivate E. coli, as
359
revealed by the high intracellular ROSs levels induced by C-nZVI.56, 57 Nevertheless, it is still a great
360
challenge to elucidate the role of intracellular ROSs because of the limited techniques to quantify or
361
quench intracellular ROSs. 16
ACS Paragon Plus Environment
Page 17 of 35
Environmental Science & Technology
362
The responses of E. coli to the oxidative stress were then checked to further reveal the
363
promotion of ROSs mediated disinfection by using A-mZVI. Increasing concentrations of H2O2 and
364
•O2- would respectively trigger the biosynthesis of SOD and catalase, which in turn quench
365
excessive •O2- and H2O2 to keep their concentrations at acceptable levels.56,
366
elevation of SOD and catalase activities are supposed to indicate more ROSs production. As
367
expected, the activities of both SOD and catalase increased more quickly when E. coli were treated
368
with A-mZVI, in agreement with its greater ROSs generating capacity. Moreover, the
369
overwhelmingly yielded ROSs by A-mZVI, especially the •OH which cannot be quenched
370
effectively by catalase or SOD, would then cause the oxidative damage of the antioxidative
371
enzymes,39, 56 resulting in the sharp decrease of enzymatic activities after only 10 min. In contrast,
372
the activities of both enzymes kept increasing until 40 min and decreased more slowly in the
373
C-nZVI/E. coli system (Figure 5a and 5b). These results further confirmed the indispensable role of
374
ROSs on the enhanced E. coli inactivation of A-mZVI.
58
Therefore, the
375
Besides the oxidative inactivation induced by ROSs, the physical disruption of cell membrane
376
by adhered ZVI particles might also contribute to the disinfection of E. coli,9, 22, 59, 60 since quenching
377
ROSs could not inhibit the inactivation of E. coli completely (Figure 3c). Therefore, we checked the
378
physical contact between ZVI and E. coli by using SEM and TEM. In the C-nZVI/E. coli system,
379
quasi-spherical nanoparticles were found to adhere to the outer surface of E. coli loosely after 1h,
380
similar with previous reports.46,
381
numerous interconnected flakes to wrap the E. coli cells more tightly (Figure 6). The different
382
shapes and adsorption of reacted A-mZVI suggested the corrosion process of ZVI was greatly
383
changed by the amorphous structure. It is well documented that the corrosion of C-nZVI took place
384
mainly at its outer surface, featured by slow leaching of Fe2+ and the onsite growth of oxide shells.61
47
Interestingly, A-mZVI formed a thick envelope assembled by
17
ACS Paragon Plus Environment
Environmental Science & Technology
Page 18 of 35
385
As a result, the adsorption of pristine or oxidized C-nZVI on the bacterial surface was hampered
386
owing to the poor dispersibility of C-nZVI. Differently, the fast dissolution of A-mZVI resulted in
387
more Fe2+ release, which was then hydrolyzed and oxidized to iron (hydro)oxide in the bulk
388
solution, thus the corrosion products of A-mZVI had easier access for the adsorption of E. coli. This
389
process was supported by the clear spatial separation of the spherical A-mZVI (denoted as
390
A-mZVI-2) from the laminar corrosion products (denoted as A-mZVI-1) in the SEM images (SI
391
Figure S10). More importantly, the iron (hydro)oxides species after corrosion were also altered by
392
the amorphous structure of A-mZVI. The XRD analysis showed that C-nZVI was converted to a
393
mixture of magnetite (Fe3O4, JCPDS No. 85-1436), akaganéite (β-FeOOH, JCPDS No. 75-1594) and
394
lepidocrocite (γ-FeOOH, JCPDS No. 70-0714), with magnetite as the dominant species, whereas
395
A-mZVI was mainly oxidized to lepidocrocite (Figure 6g), whose structure was more loosely than
396
that of magnetite and thus favored the sorption of E. coli cells. Meanwhile, it was reported that the
397
hydrolysis and oxidation of dissolved Fe2+ were able to produce polymeric Fe(OH)2 and Fe(OH)3
398
flocs as the precursors of lepidocrocite,62 and these flocs were also voluminous and favored the wrap
399
of E. coli cells.63 According to energy dispersive spectroscopy (EDS) analysis, the corrosion
400
products of A-mZVI (A-mZVI-1) possessed significantly higher carbon atomic percentage (36.41%)
401
than those (27.61% and 26.80%) of the remained spherical A-mZVI (A-mZVI-2) and used C-nZVI,
402
further confirming the higher E. coli adsorption capacity of the loose corrosion products of A-mZVI
403
(SI Figure S11).
404
The enhanced adsorption of A-mZVI corrosion products should cause more severe membrane
405
dysfunction of E. coli cells by physical disruption. Normally, the membrane potential and adenosine
406
triphosphate (ATP) synthesis capacity of cells were used as indicators of membrane dysfunction.
407
Membrane potential is crucial for the selectivity of plasma membrane,64 and the closely adhered ZVI 18
ACS Paragon Plus Environment
Page 19 of 35
Environmental Science & Technology
408
might block the ion channels and prevent the efflux of charged ions to construct the transmembrane
409
potential.65 After E. coli was treated with C-nZVI, the membrane potential maintained constant
410
during the initial 10 min, and dropped thereafter, but A-mZVI induced an instant membrane
411
potential decline as soon as E. coli was in contact with A-mZVI (Figure 5c). Moreover, the adsorbed
412
particles might isolate E. coli cells from their environment and prevent their consumption of
413
extracellular nutrients to synthesize ATP.59, 66 We collected the E. coli cells after different duration
414
of ZVI disinfection and measured their ATP synthesis rate (SI Figure S12), and found 5 min of
415
A-mZVI treatment drastically declined the rate from 4.75 to 0.87 nM/min, much faster than the case
416
of C-nZVI (Figure 5d). We thus concluded that the enhanced adhesion of corrosion products on E.
417
coli outer surface, originated from the amorphous structure of A-mZVI, also contributed to its better
418
disinfection performance.
419
It was known that the physical bacteria removal of nZVI relied on the adsorption of magnetic
420
iron oxide over bacterial surface and magnetic separation.14 However, the major corrosion product of
421
A-mZVI was lepidocrocite, whose saturation magnetization value was two orders of magnitude
422
lower than that (80-100 Am2/kg) of magnetite.62 As expected, the corrosion products of A-mZVI
423
were virtually non-magnetic (Figure 6h), and the sedimentation of the A-mZVI/E. coli mixture after
424
1 h of aerobic reaction was not affected by a magnet, different from the case of C-nZVI/E. coli
425
system (Figure 6i). These phenomena suggested that A-mZVI altered the E. coli physical removal
426
process thoroughly. Intrinsically, the suspension of E. coli is a kind of active colloid, and the rotation
427
of helical flagella endows E. coli with swimming motility, which is essential to maintain the cells
428
suspended against gravitational sedimentation.67 Therefore, the loss of motility would result in fast
429
precipitation and easy physical removal of E. coli. Although the inactivation of cells might decrease
430
motility, this reason could be ruled out because live cells were removed simultaneously with dead 19
ACS Paragon Plus Environment
Environmental Science & Technology
Page 20 of 35
431
cells by ZVI and ROSs scavengers had little impact on the removal efficiencies (Figure 3d). As
432
stated above, A-mZVI could form thick envelope to wrap the E. coli cells tightly. This might inhibit
433
the rotation of helical flagella, thus decrease the mobility of E. coli cells and the stability of the E.
434
coli colloid, and subsequently cause the aggregation and gravitational sedimentation of bacterial
435
cells. To support this hypothesis, the particle size distribution of the ZVI/E. coli mixture was
436
measured. C-nZVI treatment induced a slow increase of particle size from ca. 750 nm (bare E. coli
437
cells) at 0 min to ca. 1800 nm (nZVI bearing E. coli cells and their aggregates) at 60 min, indicating
438
the slow adsorption of C-nZVI onto E. coli. In contrast, A-mZVI caused a drastic increase of particle
439
size from ca. 750 nm to ca. 5300 nm within 5 min, confirming the effective generation of
440
voluminous corrosion products and their fast coating of cells. After 5 min, the particle size decreased
441
steadily, corresponding to the precipitation of large E. coli-iron coagulate (SI Figure S13). The
442
possible physical removal processes of two systems are illustrated in Scheme 1.
443 444
Environmental Implications. ZVI is a promising antimicrobial agent because of its low cost, high
445
activity and low toxicity. However, the antimicrobial activity of ZVI is often hampered greatly by
446
the presence of oxygen due to the growth of passivation layer and the subsequent decreased outward
447
electron transfer from iron core, which limit its use. In this study, we have revealed that
448
amorphorization is an effective strategy to improve the bactericidal ability of ZVI under aerobic
449
conditions by enhancing the electron donating capacity of iron core to produce more ROSs,
450
especially free •OH in bulk solution. More importantly, the production of abundant loose corrosion
451
products by oxygenation of A-mZVI facilitates the simultaneous inactivation and physical removal
452
of E. coli, very promising for water self-cleanup during disinfection. Since the bacteria can be
453
immobilized by the iron hydroxides and easily separated from the treated water, the release of 20
ACS Paragon Plus Environment
Page 21 of 35
Environmental Science & Technology
454
antibiotic resistance genes (ARGs) from these bacteria can be suppressed. With further
455
detoxification processes of the bacteria-containing iron sludge, the spread of ARGs in water systems
456
might be eliminated. Therefore, A-mZVI might reduce our dependence on chlorine and antibiotics to
457
tackle problems caused by carcinogenic disinfection byproducts, resistant bacteria and ARGs, etc.
458 459
AUTHOR INFORMATION
460
Corresponding Author
461
*Phone/Fax: +86-27-6786 7535; e-mail:
[email protected];
[email protected];
462
[email protected].
463
Notes
464
The authors declare no competing financial interest.
465 466
Acknowledgments: This research was financially supported by Natural Science Funds for
467
Distinguished Young Scholars (Grant 21425728), National Natural Science Foundation of China
468
(Grant 41601543 and 21777050), China Postdoctoral Science Foundation (Grant 2018T110782 and
469
2017M620327), Science Funds for Outstanding Postdocs of Hubei Province, China (Grant Z13), the
470
program of China Scholarship Council (Grant 201706775080), the 111 Project (Grant B17019), and
471
the CAS Interdisciplinary Innovation Team of the Chinese Academy of Sciences.
472 473
ASSOCIATED CONTENT
474
Supporting Information: characterization of ZVI; E. coli inactivation efficiency monitored by HPC
475
method; fluorescence images intensity processing procedures by using ImageJ; measurement of
476
dissolved iron; H2O2 determination; intracellular ROSs level detection; CAT and SOD activity 21
ACS Paragon Plus Environment
Environmental Science & Technology
Page 22 of 35
477
analysis; membrane potential measurement; ATP production rate assay; bacterial sample preparation
478
protocols for SEM and TEM; dot plots of bacterial samples in flow cytometer; TN concentrations;
479
fluorescent images of E. coli in sediment; SEM, XRD and E. coli inactivation performance of
480
C-mZVI; turbidity profile of treated water; ESR spectra of DMPO trapped •O2-; kinetic fitting of
481
H2O2 decomposition; SEM images and EDS of used ZVI; kinetics of ATP generation; particle size
482
distribution of E. coli-ZVI mixture; Comparison of the elementary and Fe0 content between the
483
C-nZVI and A-mZVI; Comparison of the E. coli inactivation performance by employing ZVI in
484
different studies.
485 486
References
487
(1) Rangsivek, R.; Jekel, M. R., Removal of dissolved metals by zero-valent iron (ZVI): Kinetics,
488
equilibria, processes and implications for stormwater runoff treatment. Water Res. 2005, 39, (17),
489
4153-4163.
490
(2) Zou, Y. D.; Wang, X. X.; Khan, A.; Wang, P. Y.; Liu, Y. H.; Alsaedi, A.; Hayat, T.; Wang, X.
491
K., Environmental Remediation and Application of Nanoscale Zero-Valent Iron and Its Composites
492
for the Removal of Heavy Metal Ions: A Review. Environ. Sci. Technol. 2016, 50, (14), 7290-7304.
493
(3) Liu, Y. Q.; Phenrat, T.; Lowry, G. V., Effect of TCE concentration and dissolved groundwater
494
solutes on NZVI-promoted TCE dechlorination and H2 evolution. Environ. Sci. Technol. 2007, 41,
495
(22), 7881-7.
496
(4) Agrawal, A.; Tratnyek, P. G., Reduction of nitro aromatic compounds by zero-valent iron metal.
497
Environ. Sci. Technol. 1996, 30, (1), 153-160.
498
(5) Jia, F. L.; Liu, J.; Zhang, L. Z., Copper Ions Promoted Aerobic Atrazine Degradation by Fe@
499
Fe2O3 Nanowires. Acta Chim. Sinica 2017, 75, (6), 602-607. 22
ACS Paragon Plus Environment
Page 23 of 35
Environmental Science & Technology
500
(6) Ai, Z. H.; Gao, Z. T.; Zhang, L. Z.; He, W. W.; Yin, J. J., Core–shell structure dependent
501
reactivity of Fe@Fe2O3 nanowires on aerobic degradation of 4-chlorophenol. Environ. Sci. Technol.
502
2013, 47, (10), 5344-5352.
503
(7) Qin, H. J.; Li, J. X.; Yang, H. Y.; Pan, B. C.; Zhang, W. M.; Guan, X. H., Coupled effect of
504
ferrous ion and oxygen on the electron selectivity of zerovalent iron for selenate sequestration.
505
Environ. Sci. Technol. 2017, 51, (9), 5090-5097.
506
(8) Mu, Y.; Ai, Z. H.; Zhang, L. Z., Phosphate shifted oxygen reduction pathway on Fe@Fe2O3
507
core–shell nanowires for enhanced reactive oxygen species generation and aerobic 4-chlorophenol
508
degradation. Environ. Sci. Technol. 2017, 51, (14), 8101-8109.
509
(9) Kim, J.; Lee, C.; Love, D. C.; Sedlak, D. L.; Yoon, J.; Nelson, K. L., Inactivation of MS2
510
coliphage by ferrous ion and zero-valent iron nanoparticles. Environ. Sci. Technol. 2011, 45, (16),
511
6978-6984.
512
(10) You, Y. W.; Han, J.; Chiu, P. C.; Jin, Y., Removal and inactivation of waterborne viruses using
513
zerovalent iron. Environ. Sci. Technol. 2005, 39, (23), 9263-9269.
514
(11) Oprckal, P.; Mladenovic, A.; Vidmar, J.; Pranjic, A. M.; Milacic, R.; Scancar, J., Critical
515
evaluation of the use of different nanoscale zero-valent iron particles for the treatment of effluent
516
water from a small biological wastewater treatment plant. Chem. Eng. J. 2017, 321, 20-30.
517
(12) Liu, J. L.; Li, X. Y., Biodegradation and biotransformation of wastewater organics as precursors
518
of disinfection byproducts in water. Chemosphere 2010, 81, (9), 1075-1083.
519
(13) Boyer, T. H.; Singer, P. C., Bench-scale testing of a magnetic ion exchange resin for removal of
520
disinfection by-product precursors. Water Res. 2005, 39, (7), 1265-1276.
521
(14) Chen, Q.; Gao, M.; Li, J.; Shen, F. X.; Wu, Y.; Xu, Z. Q.; Yao, M. S., Inactivation and
522
magnetic separation of bacteria from liquid suspensions using electrosprayed and nonelectrosprayed 23
ACS Paragon Plus Environment
Environmental Science & Technology
Page 24 of 35
523
nZVI particles: Observations and mechanisms. Environ. Sci. Technol. 2012, 46, (4), 2360-2367.
524
(15) Oguma, K.; Katayama, H.; Ohgaki, S., Photoreactivation of Legionella pneumophila after
525
inactivation by low- or medium-pressure ultraviolet lamp. Water Res. 2004, 38, (11), 2757-2763.
526
(16) Chávez de Paz, L. E.; Hamilton, I. R.; Svensäter, G., Oral bacteria in biofilms exhibit slow
527
reactivation from nutrient deprivation. Microbiology 2008, 154, (7), 1927-1938.
528
(17) Chang, P. H.; Juhrend, B.; Olson, T. M.; Marrs, C. F.; Wigginton, K. R., Degradation of
529
extracellular antibiotic resistance genes with UV254 treatment. Environ. Sci. Technol. 2017, 51, (11),
530
6185-6192.
531
(18) Huddleston, J. R., Horizontal gene transfer in the human gastrointestinal tract: potential spread
532
of antibiotic resistance genes. Infect. Drug. Resist. 2014, 7, 167-76.
533
(19) Li, J.; Chen, Q.; Li, X. Y.; Yao, M. S., Rapid point-of-use water purification using nanoscale
534
zero valent iron (nZVI) particles. Sci. Bull. 2014, 59, (29-30), 3926-3934.
535
(20) Diao, M. H.; Yao, M. S., Use of zero-valent iron nanoparticles in inactivating microbes. Water
536
Res. 2009, 43, (20), 5243-5251.
537
(21) Auffan, M.; Achouak, W.; Rose, J.; Roncato, M. A.; Chaneac, C.; Waite, D. T.; Masion, A.;
538
Woicik, J. C.; Wiesner, M. R.; Bottero, J. Y., Relation between the redox state of iron-based
539
nanoparticles and their cytotoxicity toward Escherichia coli. Environ. Sci. Technol. 2008, 42, (17),
540
6730-6735.
541
(22) Lv, Y. C.; Niu, Z. Y.; Chen, Y. C.; Hu, Y. Y., Bacterial effects and interfacial inactivation
542
mechanism of nZVI/Pd on Pseudomonas putida strain. Water Res. 2017, 115, 297-308.
543
(23) Stefaniuk, M.; Oleszczuk, P.; Ok, Y. S., Review on nano zerovalent iron (nZVI): From
544
synthesis to environmental applications. Chem. Eng. J. 2016, 287, 618-632.
545
(24) Phenrat, T.; Saleh, N.; Sirk, K.; Tilton, R. D.; Lowry, G. V., Aggregation and sedimentation of 24
ACS Paragon Plus Environment
Page 25 of 35
Environmental Science & Technology
546
aqueous nanoscale zerovalent iron dispersions. Environ. Sci. Technol. 2007, 41, (1), 284-290.
547
(25) Crane, R. A.; Scott, T. B., Nanoscale zero-valent iron: Future prospects for an emerging water
548
treatment technology. J. Hazard. Mater. 2012, 211-212, 112-125.
549
(26) Choi, H.; Al-Abed, S. R.; Agarwal, S.; Dionysiou, D. D., Synthesis of reactive nano-Fe/Pd
550
bimetallic system-impregnated activated carbon for the simultaneous adsorption and dechlorination
551
of PCBs. Chem. Mater. 2008, 20, (11), 3649-3655.
552
(27) He, F.; Zhao, D. Y.; Liu, J. C.; Roberts, C. B., Stabilization of Fe−Pd nanoparticles with sodium
553
carboxymethyl cellulose for enhanced transport and dechlorination of trichloroethylene in soil and
554
groundwater. Ind. Eng. Chem. Res. 2007, 46, (1), 29-34.
555
(28) He, F.; Zhao, D. Y., Preparation and characterization of a new class of starch-stabilized
556
bimetallic nanoparticles for degradation of chlorinated hydrocarbons in water. Environ. Sci. Technol.
557
2005, 39, (9), 3314-3320.
558
(29) Li, Z. Q.; Greden, K.; Alvarez, P. J. J.; Gregory, K. B.; Lowry, G. V., Adsorbed polymer and
559
NOM limits adhesion and toxicity of nano scale zerovalent iron to E. coli. Environ. Sci. Technol.
560
2010, 44, (9), 3462-3467.
561
(30) Zhou, L.; Thanh, T. L.; Gong, J.; Kim, J. H.; Kim, E. J.; Chang, Y. S., Carboxymethyl cellulose
562
coating decreases toxicity and oxidizing capacity of nanoscale zerovalent iron. Chemosphere 2014,
563
104, 155-161.
564
(31) Ayush, V.; Francesco, S., Effect of surface properties on nanoparticle–cell interactions. Small
565
2010, 6, (1), 12-21.
566
(32) Chen, J. W.; Xiu, Z. M.; Lowry, G. V.; Alvarez, P. J. J., Effect of natural organic matter on
567
toxicity and reactivity of nano-scale zero-valent iron. Water Res. 2011, 45, (5), 1995-2001.
568
(33) Liu, Y. Q.; Choi, H.; Dionysiou, D.; Lowry, G. V., Trichloroethene hydrodechlorination in 25
ACS Paragon Plus Environment
Environmental Science & Technology
Page 26 of 35
569
water by highly disordered monometallic nanoiron. Chem. Mater. 2005, 17, (21), 5315-5322.
570
(34) Nurmi, J. T.; Tratnyek, P. G.; Sarathy, V.; Baer, D. R.; Amonette, J. E.; Pecher, K.; Wang, C.;
571
Linehan, J. C.; Matson, D. W.; Penn, R. L.; Driessen, M. D., Characterization and properties of
572
metallic iron nanoparticles: Spectroscopy, electrochemistry, and kinetics. Environ. Sci. Technol.
573
2005, 39, (5), 1221-1230.
574
(35) Wang, Q. L.; Lee, S.; Choi, H., Aging study on the structure of Fe0-nanoparticles: Stabilization,
575
characterization, and reactivity. J. Phys. Chem. C 2010, 114, (5), 2027-2033.
576
(36) Yániz, J.; Palacín, I.; Vicente-Fiel, S.; Gosálvez, J.; López-Fernández, C.; Santolaria, P.,
577
Evaluation of a commercial kit based on acridine orange/propidium iodide to assess the plasma
578
membrane integrity of ram sperm. Span. J. Agric. Res. 2013, 11, (2), 362-365.
579
(37) Harvey Jr, A. E.; Smart, J. A.; Amis, E., Simultaneous spectrophotometric determination of iron
580
(II) and total iron with 1, 10-phenanthroline. Anal. Chem. 1955, 27, (1), 26-29.
581
(38) Chen, N.; Huang, Y. H.; Hou, X. J.; Ai, Z. H.; Zhang, L. Z., Photochemistry of hydrochar:
582
Reactive oxygen species generation and sulfadimidine degradation. Environ. Sci. Technol. 2017, 51,
583
(19), 11278-11287.
584
(39) Sun, H. W.; Li, G. Y.; An, T. C.; Zhao, H. J.; Wong, P. K., Unveiling the photoelectrocatalytic
585
inactivation mechanism of Escherichia coli: Convincing evidence from responses of parent and
586
anti-oxidation single gene knockout mutants. Water Res. 2016, 88, 135-143.
587
(40) Wang, C. B.; Zhang, W. X., Synthesizing nanoscale iron particles for rapid and complete
588
dechlorination of TCE and PCBs. Environ. Sci. Technol. 1997, 31, (7), 2154-2156.
589
(41) Chekli, L.; Bayatsarmadi, B.; Sekine, R.; Sarkar, B.; Shen, A. M.; Scheckel, K. G.; Skinner, W.;
590
Naidu, R.; Shon, H. K.; Lombi, E.; Donner, E., Analytical characterisation of nanoscale zero-valent
591
iron: A methodological review. Anal. Chim. Acta 2016, 903, 13-35. 26
ACS Paragon Plus Environment
Page 27 of 35
Environmental Science & Technology
592
(42) US EPA. Gold Book-Water Quality for Water, 1986.
593
(43) US PEA. Aquatic Life: Ambient Water Quality Criteria for Ammonia-Freshwater, 2013,
594
EPA-822-R-13-001.
595
(44) World Health Organization, Concise international chemical assessment document 15:
596
1,2-diaminoethane (ethylenediamine), Geneva, 1999
597
(45) Sun, H. W.; An, T. C.; Li, G. Y.; Qiao, M.; Wei, D. B., Distribution, possible sources, and
598
health risk assessment of SVOC pollution in small streams in Pearl River Delta, China. Environ. Sci.
599
Pollut. Res. 2014, 21, (17), 10083-10095.
600
(46) Chen, Q.; Li, J.; Wu, Y.; Shen, F. X.; Yao, M. S., Biological responses of Gram-positive and
601
Gram-negative bacteria to nZVI (Fe0), Fe2+ and Fe3+. RSC Adv. 2013, 3, (33), 13835-13842.
602
(47) Lee, C.; Kim, J. Y.; Lee, W. I.; Nelson, K. L.; Yoon, J.; Sedlak, D. L., Bactericidal effect of
603
zero-valent iron nanoparticles on Escherichia coli. Environ. Sci. Technol. 2008, 42, (13), 4927-4933.
604
(48) Dong, H. R.; Xie, Y. K.; Zeng, G. M.; Tang, L.; Liang, J.; He, Q.; Zhao, F.; Zeng, Y. L.; Wu,
605
Y. A., The dual effects of carboxymethyl cellulose on the colloidal stability and toxicity of nanoscale
606
zero-valent iron. Chemosphere 2016, 144, 1682-1689.
607
(49) Turbidity and TSS (accessed on Feb 21, 2019).
608
http://www.lakesuperiorstreams.org/understanding/param_turbidity.html
609
(50) Lefevre, E.; Bossa, N.; Wiesner, M. R.; Gunsch, C. K., A review of the environmental
610
implications of in situ remediation by nanoscale zero valent iron (nZVI): Behavior, transport and
611
impacts on microbial communities. Sci. Total Environ. 2016, 565, 889-901.
612
(51) He, D.; Ma, J. X.; Collins, R. N.; Waite, T. D., Effect of structural transformation of
613
nanoparticulate zero-valent iron on generation of reactive oxygen species. Environ. Sci. Technol.
614
2016, 50, (7), 3820-3828. 27
ACS Paragon Plus Environment
Environmental Science & Technology
Page 28 of 35
615
(52) Mu, Y.; Jia, F. L.; Ai, Z. H.; Zhang, L. Z., Molecular Oxygen Activation with Nano Zero-valent
616
Iron for Aerobic Degradation of Organic Contaminants and the Performance Enhancement. Acta
617
Chim. Sinica 2017, 75, (6), 538-543.
618
(53) Sun, H. W.; Li, G. Y.; Nie, X.; Shi, H. X.; Wong, P. K.; Zhao, H. J.; An, T. C., Systematic
619
approach to in-depth understanding of photoelectrocatalytic bacterial inactivation mechanisms by
620
tracking the decomposed building blocks. Environ. Sci. Technol. 2014, 48, (16), 9412-9419.
621
(54) Liu, W.; Ai, Z. H.; Cao, M. H.; Zhang, L. Z., Ferrous ions promoted aerobic simazine
622
degradation with Fe@Fe2O3 core–shell nanowires. Appl. Catal. B-Environ. 2014, 150-151, 1-11.
623
(55) Hou, X. J.; Huang, X. P.; Jia, F. L.; Ai, Z. H.; Zhao, J. C.; Zhang, L. Z., Hydroxylamine
624
promoted goethite surface Fenton degradation of organic pollutants. Environ. Sci. Technol. 2017, 51,
625
(9), 5118-5126.
626
(56) Ezraty, B.; Gennaris, A.; Barras, F.; Collet, J. F., Oxidative stress, protein damage and repair in
627
bacteria. Nat. Rev. Microbiol. 2017, 15, (7), 385-396.
628
(57) Kakhlon, O.; Cabantchik, Z. I., The labile iron pool: characterization, measurement, and
629
participation in cellular processes. Free Radical Bio. Med. 2002, 33, (8), 1037-1046.
630
(58) Cabiscol Català, E.; Tamarit Sumalla, J.; Ros Salvador, J., Oxidative stress in bacteria and
631
protein damage by reactive oxygen species. Int. Microbiol. 2000, 3, (1), 3-8.
632
(59) Akhavan, O.; Ghaderi, E.; Esfandiar, A., Wrapping bacteria by graphene nanosheets for
633
isolation from environment, reactivation by sonication, and inactivation by near-infrared irradiation.
634
J. Phys. Chem. B 2011, 115, (19), 6279-6288.
635
(60) Kim, J. Y.; Park, H. J.; Lee, C.; Nelson, K. L.; Sedlak, D. L.; Yoon, J., Inactivation of
636
Escherichia coli by nanoparticulate zerovalent iron and ferrous ion. Appl. Environ. Microbiol. 2010,
637
76, (22), 7668-70. 28
ACS Paragon Plus Environment
Page 29 of 35
Environmental Science & Technology
638
(61) Liu, A. R.; Liu, J.; Zhang, W. X., Transformation and composition evolution of nanoscale zero
639
valent iron (nZVI) synthesized by borohydride reduction in static water. Chemosphere 2015, 119,
640
1068-1074.
641
(62) Cornell, R. M.; Schwertmann, U., The iron oxides: structure, properties, reactions, occurrences
642
and uses. John Wiley & Sons: 2003.
643
(63) Noubactep, C., On the mechanism of microbe inactivation by metallic iron. J. Hazard. Mater.
644
2011, 198, 383-6.
645
(64) Shin, E. H.; Li, Y.; Kumar, U.; Sureka, H. V.; Zhang, X.; Payne, C. K., Membrane potential
646
mediates the cellular binding of nanoparticles. Nanoscale 2013, 5, (13), 5879-86.
647
(65) Warren, E. A. K.; Payne, C. K., Cellular binding of nanoparticles disrupts the membrane
648
potential. RSC Adv. 2015, 5, (18), 13660-13666.
649
(66) Xiu, Z. M.; Jin, Z. H.; Li, T. L.; Mahendra, S.; Lowry, G. V.; Alvarez, P. J. J., Effects of
650
nano-scale zero-valent iron particles on a mixed culture dechlorinating trichloroethylene.
651
Bioresource Technol. 2010, 101, (4), 1141-1146.
652
(67) Schwarz-Linek, J.; Arlt, J.; Jepson, A.; Dawson, A.; Vissers, T.; Miroli, D.; Pilizota, T.;
653
Martinez, V. A.; Poon, W. C. K., Escherichia coli as a model active colloid: A practical
654
introduction. Colloids and Surfaces B: Biointerfaces 2016, 137, 2-16.
655 656
29
ACS Paragon Plus Environment
Environmental Science & Technology
Page 30 of 35
657 658
Figure 1. The typical SEM images of (a) C-nZVI and (b, c) A-mZVI. (d) XRD of A-mZVI and
659
C-nZVI.
660 661
Figure 2. (a) The temporary change of E. coli concentrations in the supernatants during ZVI
662
inactivation processes. (b) The ratio of survived E. coli among the total cells in the supernatants 30
ACS Paragon Plus Environment
Page 31 of 35
Environmental Science & Technology
663
treated by C-nZVI and A-mZVI, respectively. (c) The removal efficiencies of total E. coli cells from
664
the supernatants by C-nZVI and A-mZVI as a function of time. (d) The temporary trend of the
665
bacterial viability in the sediment samples as reflected by the intensity ratios of green and red
666
fluorescence. The ZVI dose was 100 mg/L, and the initial concentration of E. coli was OD670nm =
667
0.06 in 0.85% NaCl.
668 669
Figure 3. (a) The survival ratio and (b) removal efficiency of E. coli in the supernatant as a function
670
of ZVI dose. The impacts of ROSs scavengers on (c) inactivation of E. coli and (d) removal
671
efficiency of E. coli in the supernatant. The duration of disinfection was 60 min, and the initial
672
concentration of E. coli was OD670nm = 0.06 in 0.85% NaCl. For scavenging experiments, the ZVI
673
dose was 200 mg/L and the concentrations of SOD, catalase and TBA were 100 mg/L, 100 mg/L and
674
1% (v/v), respectively.
31
ACS Paragon Plus Environment
Environmental Science & Technology
Page 32 of 35
675 676
Figure 4. (a) The temporary change of dissolved iron concentrations from C-nZVI and A-mZVI
677
during the disinfection process. (b) Time profiles of ESR intensities of DMPO-•O2- adduct. (c)
678
Accumulation of H2O2 as a function of time. (d) Decomposition profile of H2O2 by C-nZVI and
679
A-mZVI. (e) Evolution of intracellular ROSs level within E. coli treated by C-nZVI and A-mZVI. (f)
680
Time profiles of ESR intensities generated by DMPO trapped •OH (symbols + lines), and the
681
proportions of surface bound •OH among overall •OH production (bars). The ZVI dose was 100
682
mg/L and the concentration of F- was 2 × 10-3 mol/L.
32
ACS Paragon Plus Environment
Page 33 of 35
Environmental Science & Technology
683 684
Figure 5. The evolution of enzymatic activities of (a) catalase and (b) superoxide dismutase (SOD)
685
as a function of ZVI inactivation time. (c) The time profile of bacterial membrane potential
686
represented by the fluorescent intensity of Rh123 stained cells. (d) The impact of ZVI on ATP
687
synthesis capacity of E. coli. The ZVI dose was 100 mg/L.
33
ACS Paragon Plus Environment
Environmental Science & Technology
Page 34 of 35
688 689
Figure 6. The SEM (a, b, c) and TEM (d, e, f) images of the E. coli cells before (a, d) and after 1 h
690
of disinfection treating by C-nZVI (b, e) and A-mZVI (c, f). (g) The XRD patterns and (h) the
691
magnetic hysteresis loops of the corrosion products generated by C-nZVI and A-mZVI after 1 h of
692
aerobic disinfection. (i) The sedimentation curves of ZVI-E. coli mixture after 1 h of aerobic
693
disinfection, w/ and w/o a magnet.
694 695
Scheme 1. The possible physical removal processes of E. coli from supernatant by C-nZVI and
696
A-mZVI. 34
ACS Paragon Plus Environment
Page 35 of 35
697
Environmental Science & Technology
TOC Art Figure
698
35
ACS Paragon Plus Environment