Subscriber access provided by CORNELL UNIVERSITY LIBRARY
Article
Relative significance of the negative impacts of hemicelluloses on enzymatic cellulose hydrolysis is dependent on lignin content: evidences from substrate structural features and protein adsorption Hongmei Chen, Xuebing Zhao, and Dehua Liu ACS Sustainable Chem. Eng., Just Accepted Manuscript • DOI: 10.1021/ acssuschemeng.6b01540 • Publication Date (Web): 03 Oct 2016 Downloaded from http://pubs.acs.org on October 7, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
ACS Sustainable Chemistry & Engineering is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
1
Gradient
Elution
Moving
Boundary
2
Electrophoresis enables rapid analysis of acids in
3
complex biomass-derived streams
4
Matthew S. Munson†,‡,≠, Eric M. Karp¶, Claire T. Nimlos¶, Marc Salit†,‡,≠, and Gregg T.
5
Beckham¶,*
6 7 8
† Joint Initiative for Metrology in Biology, 443 Via Ortega, Shriram Center, Stanford University, Stanford CA 94305
9 10
‡ Genome Scale Measurements Group, 443 Via Ortega, Shriram Center, National Institute of Standards and Technology, Stanford, CA 94305
11 12
≠ Department of Bioengineering, Stanford University, 443 Via Ortega, Shriram Center, Stanford, CA 94305
13 14
¶ National Bioenergy Center, National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden CO 80401
15 16
* Corresponding Author Email
[email protected] 17
Key words
18
Biomass conversion, Biorefinery, Lignin, Analytical Chemistry, GEMBE
19 20 21 22
ACS Paragon Plus Environment
1
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 2 of 37
23
Abstract
24
Biomass conversion processes such as pretreatment, liquefaction, and pyrolysis often produce
25
complex mixtures of intermediates that are a substantial challenge to rapidly and reliably
26
analyze. To more comprehensively and efficiently characterize these complex streams, new
27
techniques are needed to track species through biomass deconstruction and conversion processes.
28
Here, we present the application of an emerging analytical method, Gradient Elution Moving
29
Boundary Electrophoresis (GEMBE), to quantify a suite of acids in a complex, biomass-derived
30
streams from alkaline pretreatment of corn stover. GEMBE offers distinct advantages over
31
common chromatography-spectrometry analytical approaches in terms of analysis time, sample
32
preparation requirements, and cost of equipment. As demonstrated here, GEMBE is able to track
33
17 distinct compounds (oxalate, formate, succinate, malate, acetate, glycolate, protocatechuate,
34
3-hydroxypropanoate, lactate, glycerate, 2-hydroxybutanoate, 4-hydroxybenzoate, vanillate, p-
35
coumarate, ferulate, sinapate, and acetovanillone). The lower limit of detection was compound
36
dependent and ranged between 0.9 µmol/L and 3.5 µmol /L. Results from GEMBE were similar
37
to recent results from an orthogonal method. Overall, GEMBE offers a rapid, robust approach to
38
analyze complex biomass-derived samples, and given the ease and convenience of deployment,
39
may offer an analytical solution for online tracking of multiple types of biomass streams.
40
ACS Paragon Plus Environment
2
Page 3 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
41
Introduction
42
Biomass conversion processes often rely on a combination of heat, catalysts, and/or mechanical
43
work to process lignocellulosic material. As plant cell walls are complex, composite materials
44
comprising several biopolymers, among other components, many biomass conversion processes
45
produce highly heterogeneous mixtures of compounds that are challenging to characterize.
46
Similar challenges exist in conversion processes of other heterogeneous biomass mixtures such
47
as in process streams of municipal solid waste and algae. The development of robust analytical
48
approaches to monitor solubilized biomass streams is a critical component of the continued
49
development of biomass valorization approaches, as measuring conversion of intermediates to
50
products is often both a challenge and a key need for process monitoring.
51 52
Alkaline pretreatment liquor (APL) is an exemplary complex, lignin-rich, solubilized mixture
53
generated during high pH treatment of biomass. It is composed of high molecular weight lignin,
54
low molecular weight aromatic compounds derived from lignin depolymerization, hydroxy acids
55
from sugar degradation reactions, alcohols, aldehydes, and other higher molecular weight
56
partially depolymerized biopolymers.1 Due to the high degree of chemical heterogeneity, these
57
types of solutions are generally metastable and the addition of solvents, acids, or other agents
58
during workup facilitates subsequent reactions making it difficult to derive quantitative
59
information from the original sample. In the case of APL, the solution generally has a pH > 102-3
60
and decreasing the solution pH < 5 causes much of the solubilized material to precipitate. This
61
characteristic rules out many liquid chromatography techniques that do not operate at high pH or
62
that use non-aqueous mobile phases. Additionally, the analytical technique of choice must be
63
able to separate a wide range of chemicals with varying functionalities. Thus, there are few non-
ACS Paragon Plus Environment
3
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 4 of 37
64
destructive methods available that apply to lignin rich solutions, such as APL, that are produced
65
in a biorefinery.1,
66
various lignin conversion processes that utilize these complex lignin rich materials is crucial for
67
the maturation of the technologies, and will require development of robust analytical techniques
68
for tracking organic compounds in these complex substrates.
4
However, assessing the merits of biological conversion5-8 or any of the
69 70
Electrophoretic techniques, namely capillary electrophoresis (CE), operate at high pH and have
71
demonstrated success in measuring inorganic and some organic components in kraft black
72
liquors, but run times are often long and the slate of compounds that can be measured via the CE
73
methods are somewhat limited.9-14 Gradient Elution Moving Boundary Electrophoresis
74
(GEMBE) offers the potential for faster and more robust analysis of these types of complex
75
samples.15-17 GEMBE (represented schematically in Figure 1) is injectionless, and relies on a
76
counterflow modulated over the course of the separation to achieve selectivity on the basis of
77
electrophoretic mobility. Briefly, a separation channel comprised of fused silica capillary bridges
78
a pressure controlled separation buffer reservoir and a sample reservoir. Voltage is applied
79
between the reservoirs driving electroosmotic flow towards from the buffer reservoir towards the
80
sample, and electromigration of charged species in the sample towards the buffer reservoir. A
81
pressure driven flow is superimposed on the electroosmotic flow to control the overall flow rate.
82
At the beginning of the separation, the convective velocity at the channel entrance exceeds the
83
electrophoretic velocity for all analytes of interest. The applied pressure is then gradually
84
reduced resulting in sequential elution of analytes into the capillary in the order of
85
electrophoretic mobility. The eluted boundaries are detectable as steps using a variety of
ACS Paragon Plus Environment
4
Page 5 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
86
detectors, in the case of this work, capacitively coupled contactless conductivity detection
87
(C4D).18-21
88 89
GEMBE can be operated using a wide range of conditions (pH, sample conductivity, etc.)22-24
90
with relatively inexpensive instrumentation25-27 and can utilize a diversity of detection modes.17,
91
25, 27-28
92
achieve demanding separations29, can handle samples containing particulates24, 30, and can be
93
used for online monitoring of reactions within a sample.25 The use of a “universal detector” is
94
enabled by orthogonal analysis methods that allow for peak identification, such as the GCxGC-
95
MS method described in our concurrent report.4
It has also been demonstrated that GEMBE can operate in multidimensional modes to
96 97
Once a select set of compounds are identified using a method such as the GCxGC-TOF/MS
98
method described by Karp et al.4, GEMBE can be applied to more rapidly analyze samples for
99
the identified compounds. In this work, we demonstrate the utility of GEMBE for the
100
quantification of the major lignin and sugar degradation products present in corn stover APL
101
over a variety of pretreatment conditions. Our results are then quantitatively compared to
102
samples representing identical process conditions analyzed by an orthogonal GCxGC-TOF/MS
103
method. GEMBE offers distinct advantages in terms of analysis time, sample preparation
104
requirements, and cost of equipment over the GCxGC-TOF/MS method.
105 106
Results and Discussion
107
Identification of Analytes of Interest
ACS Paragon Plus Environment
5
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 6 of 37
108
The use of a C4D as a detection mode in GEMBE requires a priori knowledge of what analytes
109
are likely to be present in the samples of interest. This method development knowledge
110
accelerates the identification of separation conditions, and enables the assignment of compounds
111
to corresponding electropherogram steps. For APL, a list of target analytes was constructed from
112
a combination of literature review and orthogonal methods that utilize MS for compound
113
identification.4 The compounds of interest are summarized in Table S1. APL is rich in both
114
monoaromatic compounds from the breakdown of lignin, and also organic acids from the
115
degradation of carbohydrates.1, 4
116 117
Identification of Separation Conditions
118
Optimization of separation conditions is strongly influenced by the physical properties of the
119
analytes of interest. The primary mechanism for resolving species in GEMBE is electrophoretic
120
mobility, which is determined by the ratio of the analytes electrical charge and hydrodynamic
121
drag. The pH of the separation buffer is therefore a critical parameter in resolving the analytes.
122
The effective charge for each species was estimated for pH values from 7 to 11. We used the
123
estimated charge-to-mass ratio as a prediction of the relative mobility of each analyte as a
124
function of pH, normalized to acetate, which was constant across the pH range examined (Figure
125
S1). While these calculations suggest a pH of 10 would be optimal, we implemented our method
126
using a background electrolyte (BGE) that had previously been used for GEMBE17 having a pH
127
of 8.3 (250 mM Tris, 250 mM Boric Acid). The consequence of this is that the several of the
128
suspected analytes are not anticipated to be detectable. These analytes are noted in Table S1.
129
ACS Paragon Plus Environment
6
Page 7 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
130
Other key operating parameters were optimized empirically. Reducing capillary inner diameter
131
can increase the peak capacity of the separation at the cost of limit of detection. A capillary ID of
132
10 µm was determined to give the best performance for these samples. After selecting a capillary
133
ID, the maximum field that can be applied without generating significant Joule heating was
134
determined to be 500 V/cm (or 2.5 kV across the 5cm capillary). The applied pressure was
135
reduced at a rate of -62.5 Pa/s starting at a value of +30 kPa and ending at -26 kPa. The starting
136
pressure for the separation is selected by determining the entry pressure for the fastest analyte of
137
interest. To account for experimental fluctuations, the starting pressure was set 1 kPa higher than
138
the calculated entry pressure. The ending pressure was determined by finding the applied
139
pressure that results in bulk reversal of flow. The separation time scales linearly, while the
140
resolution increases with the square root of the pressure ramp rate. We established an arbitrary
141
maximum separation time of 1,000 sec, including necessary rinse times to calculate the slowest
142
acceptable ramp rate. A characteristic electropherogram is presented in Figure 2A. Each stepwise
143
change in conductivity represents the elution front of an analyte (or unresolved group of
144
analytes). Interpretation of the electropherograms is aided by computing the time derivative of
145
the detector signal (Figure 2B) resulting in a conventional electropherogram. This report contains
146
a detailed discussion of the use of GEMBE for the analysis of corn stover APL and comparison
147
of the method to our GCxGC-MS method.4 The separation conditions identified are also
148
amenable to analysis of APL derived from other feedstocks (e.g. switchgrass, pine, etc.), and for
149
tracking bioconversion of these APL substrates. Representative electropherograms for samples
150
derived from materials other than corn stover are shown in the SI (Figure S2).
151 152
Sample Properties – Dynamic Range, Conductivity, and Particulates
ACS Paragon Plus Environment
7
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 37
153
The components of APL span a large dynamic range in concentration. This makes it challenging
154
to determine the optimal dilution factor for the raw samples in BGE that will allow low
155
abundance species to be detected without the high abundance species saturating the detector, or
156
electrostatically overloading the separation zones. This challenge was addressed by analyzing
157
each sample at two dilution levels. Samples were diluted 100x and 1,000x in BGE. High
158
concentration analytes were quantified from 1,000X dilution, while low concentration analytes
159
were determined from the 100X dilution.
160 161
The properties of APL samples vary as a function of pretreatment conditions. The conductivity
162
of the sample is of particular importance for GEMBE. The variation in conductivity of APL
163
arises primarily as a function of NaOH loading, which is trivially anticipated. The pretreatment
164
temperature also impacts the conductivity of the APL, however, as higher temperatures result in
165
the production of increasing levels of charged breakdown products. APL samples diluted in BGE
166
that have a different conductivity than the BGE will result in field amplified sample stacking at
167
the capillary entrance,27, 31 which results in an increase in step height when the sample is less
168
conductive than the BGE and a reduction in step height when the sample is more conductive than
169
the BGE. This effect limits the ability to compare samples with different conductivities and
170
construct calibrations that apply across all samples. One strategy to mask the variation in
171
conductivity between samples is to increase the conductivity of the BGE so that the conductivity
172
of the diluted APL sample is dominated by the BGE conductivity. Raising the conductivity of the
173
BGE has deleterious effects on the separation, as it raises the limit of detection (LOD) and
174
reduces resolution by decreasing the maximum applied voltage. Given the high conductivity of
175
the APL samples (between 7 and 120 mS cm-1) examined in this report (Table S2), this approach
ACS Paragon Plus Environment
8
Page 9 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
176
is not feasible. Alternatively, we employed an internal standard to track the extent of sample
177
stacking observed in each separation. Sodium bromide was added to each sample at a
178
concentration of 30 µM. The bromide ion was chosen as the internal standard because it is absent
179
in the APL samples and is both resolved from and higher in electrophoretic mobility than all the
180
other species present including chloride. All calculated step heights are then normalized by the
181
ratio of the bromide step in the sample and a sample containing only sodium bromide. The
182
elution time of the bromide zone was used to align all electropherograms.
183 184
APL samples also contain significant particulates of varying size. GEMBE can be adversely
185
impacted by sample particulates, and strategies have been developed to mitigate these effects.24
186
With the conditions employed in this report, biomass particulates were not observed to migrate
187
in the separation channel. We did however observe particulates in the BGE. We hypothesize that
188
these were likely borate precipitates. For samples where the passage of a particle would affect
189
determination of the step height associated with an analyte in a given sample, that step was
190
excluded from the data set. The frequency of this occurrence was less than 0.1% of all
191
sample/analyte combinations characterized in this study.
192 193
Assignment of Analytes to Corresponding Electropherogram Steps
194
Each analyte listed Table S1 was prepared separately at 130 µM in BGE with 30 µM NaBr and
195
analyzed, allowing us to determine the elution order and order of magnitude of the detector
196
response. Several of the listed compounds could not be detected. The resultant
197
electropherograms can be superimposed (Figure S3) to determine which analytes, if present in
198
the sample would be resolved. The mapping of compound to step numbers as noted in Figure 2B
ACS Paragon Plus Environment
9
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 10 of 37
199
is detailed in Table 1. Of the analytes listed, 15 were able to be adequately resolved from each
200
other, 9 were not detectable, and 10 were detected as part of co-eluting steps. Several other
201
compounds (noted in Table S1) were analyzed in an effort to identify unassigned steps in the
202
electropherogram resulting in the identification of steps corresponding to chloride, sulfate,
203
carbonate, and phosphate ions. Detectable analytes were pooled at known concentration ratios
204
and spiked into representative APL samples for final identification electropherogram steps. A
205
single representative compound was chosen to represent all the components of co-eluting steps.
206
Several steps in the electropherogram remain unidentified. The presence of unidentified steps
207
underscores the value of companion methods4 that allow for determination of chemical identity
208
to guide peak identification.
209 210
Standards of 2-hydroxybutanoic acid and salicylic acid coelute (step 13), vanillic acid and
211
gluconic acid coelute (step 15), and p-coumaric acid and 2-hydroxyisocaproic acid coelute (step
212
16). Our orthogonal characterization of comparable APL samples did not detect salicylic acid,
213
and detected gluconic acid and 2-hydroxyisocaproic acid at trace levels.4 We therefore consider
214
step 13 to be representative of the 2-hydroxybutanoic acid concentration, step 15 to be
215
representative of the concentration of vanillic acid, and step 16 to be representative of the
216
concentration of p-coumaric acid. Standards for ferulic acid, syringic acid, vanillin, and catechol
217
co-elute (step 17). Prior results show that vanillin is not present in similar samples, and syringic
218
acid is present at trace levels.4 Catechol was not quantifiable using the GCxGC-MS method, but
219
based on literature reports is likely to be present.1 The height of Step 17 is therefore assumed to
220
be proportional to the response-weighted sum of the concentrations of catechol and ferulic acid.
221
It is not possible to determine the distribution of components in the step from a single
ACS Paragon Plus Environment
10
Page 11 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
222
measurement of height. Catechol is also a key metabolic intermediate in biological conversion of
223
APL.32 Future adaptation of this technique to monitoring metabolite consumption and production
224
during biological conversion will benefit from resolution of catechol from ferulic and syringic
225
acid.
226 227
We also observe several system steps with this BGE. The system effects have an adverse impact
228
on quantification for several of the analytes of interest. The most significant system step arises
229
from the presence of carbonate in the BGE and samples. Carbonate forms a large system step at
230
an elution time of approximately 620 sec. We anticipate that the size and variability of the
231
carbonate step interferes with the quantification of muconate. Calibration of muconate was not
232
attempted in this report, as it was not observed to be at detectable concentrations in the APL
233
samples considered. Formic acid, succinic acid, and malic acid (steps 2, 3, and 4 respectively)
234
coelute with system steps. The contribution of the system steps to the observed signal for each of
235
these analytes was determined by analyzing a blank sample (containing only 30 µM NaBr in
236
BGE) each day, and subtracting the value of step height in the blank from the step height
237
determined in the sample.
238 239
The elution order generally followed the predicted mobility (Figure S1). The notable deviations
240
from predicted mobility are protocatechuic acid and catechol. Both compounds have higher
241
electrophoretic mobility that was anticipated by their charge to mass ratios, particularly catechol,
242
which should be neutrally charged at pH 8.3. As boric acid is known to form covalent anionic
243
complexes with polyhydroxy compounds,33-34 the apparent acceleration of catechol and
244
protocatechuic acid is likely a result of the formation such complexes. The steps corresponding
ACS Paragon Plus Environment
11
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 37
245
to these two compounds are significantly broadened in comparison to the characteristic step
246
width of other analytes, suggesting that under the conditions employed the relevant species are in
247
a dynamic equilibrium. Given these observations, and the number of target analytes that contain
248
multiple hydroxide groups, it is likely that the boric acid in the BGE is contributing to the
249
resolution of the method.
250 251
Calibration
252
System calibration was conducted using a mixed pool design. Six subpools consisting of
253
equimolar mixtures of three compounds were prepared. These pools were mixed at known ratios
254
to produce six calibration pools using a complete latin square design (Table S3). The calibration
255
pools were treated as though they were samples, i.e., diluted 100x and 1,000x prior to analysis
256
with GEMBE. The concentration range for each analyte in the diluted samples is from 6 µM to
257
300 µM. Calibration samples were analyzed in triplicate. Sulfate and phosphate were included in
258
the pool design in order to balance the number of analytes in each subpool. These analytes were
259
not of sufficient interest in our applications to warrant analysis. Calibration curves for 16 of the
260
calibrants are shown in Figure S4. The limit of detection (LOD) and limit of quantitation (LOQ)
261
are defined in this paper as 3 and 10 times the ratio of estimated standard error of the intercept
262
and the estimated slope of the regression line, respectively. The LOD and LOQ for each
263
compound are reported in Table 2, in units of µmol L-1, and mg mL-1.
264
We were not able to directly calibrate 3-hydroxypropionic acid because standards of sufficient
265
purity are not available. We applied the calibration curve for lactic acid to approximate
266
quantification of 3-hydroxypropionic acid. The two compounds are structural isomers, and
267
although the pKa’s of the carboxylic acid protons are different (3.8 for lactate and 4.2 for 3-
ACS Paragon Plus Environment
12
Page 13 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
268
hydroxypropionate), both should have identical valence (-1) and molecular mass at pH 8.3, and
269
thereby have nearly the same electrophoretic mobility. The signal generated using C4D is
270
proportional to the concentration of an analyte and its mobility relative to the mobility of both
271
buffer species,21 and as such, lactate and 3-hydroxypropionate should produce nearly identical
272
detector responses. The fact that the two compounds are resolvable, indicates that their mobilities
273
in this system are not identical, as such, we consider the results reported for 3-hydroxypropionic
274
acid to be approximations.
275 276
Analysis of APL samples
277
We demonstrated the utility of GEMBE by analyzing a series of corn stover-derived APL
278
samples representing a range of NaOH loadings at two processing temperatures. These samples
279
were process replicates of the samples analyzed with an orthogonal GCxGC-MS method
280
described elsewhere.4 Each sample was analyzed in triplicate. The 12 samples were randomized
281
across eight experimental days. Five of the samples were repeated within a single day. This
282
allows us to compare the interday and intraday repeatability of the method in aggregate, and for
283
each analyte. Considering only analytes that were determined to be present above the LOQ, the
284
aggregate relative standard deviation for these samples was 8.5%, and the relative standard
285
deviation for the samples repeated within a day was 4.6%.
286 287
Lignin degradation products: We were able to quantify four monoaromatic compounds present
288
in APL using GEMBE: p-coumaric acid, ferulic acid, vanillic acid, and 4-hydroxybenzoic acid
289
(Figure 3). For all these compounds except 4-hydroxybenzoic acid, the GEMBE and GCxGC-
290
MS results compare favorably with respect to the total amount present and the overall trend
ACS Paragon Plus Environment
13
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 14 of 37
291
associated with increasing NaOH loading. The results from the GC method detect 4-
292
hydroxybenzoic acid as a trace component, while GEMBE detects this compound at a
293
characteristic level of approximately 1 mg/mL, which is comparable (on a mass basis) to the
294
amount of vanillic acid detected by both methods. The GEMBE method presented here is also
295
capable of quantifying acetovanillone and protocatechuic acid, as demonstrated by the
296
construction of calibration curves. Both compounds were not present at concentrations high
297
enough to be quantifiable with GEMBE in the APL samples. Protocatechuic acid is anticipated
298
to be at trace levels by our GC method and is an important compound to track in bioconversion
299
samples. Acetovanillone is routinely detected by the GCxGC-TOF/MS method, but is between
300
the LOD and LOQ of the GEMBE method due to its partial charge at pH 8.3.
301 302
Sugar degradation products: The GEMBE method is capable of quantifying five of the six
303
sugar degradation products that were reported using GC analysis4: lactic acid, glyceric acid,
304
glycolic acid, 3-hydroxypropanoic acid, and 2-hydroxybutanoic acid, but unable to detect
305
glycerol. The impact of process temperature and NaOH loading on the concentration of these
306
analytes was determined (Figure 4). Failure to detect glycerol, although it is present at mmol L-1
307
levels in APL4 is due to the lack of charge on the analyte under the conditions utilized here. The
308
pH required for glycerol to have a comparable charge-to-mass ratio as the slowest eluting analyte
309
detected with the current method (acetovanillone) is approximately 13.3. The GEMBE method
310
was able to quantify five additional compounds that were unable to be quantified using the
311
GCxGC-TOF/MS method: acetic acid, formic acid, oxalic acid, succinic acid, and malic acid.
312
The impact of process temperature and NaOH loading on the concentration of these analytes was
313
determined (Figure 5). Acetic acid could not be quantified with GCxGC-TOF/MS due to its
ACS Paragon Plus Environment
14
Page 15 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
314
volatility during the dry-down phase, and formic acid was lost in the solvent. The remaining
315
three compounds -- succinic acid, malic acid, and oxalic acid – were all detected at trace (defined
316
as less than 0.1 mg/mL) levels by the GCxGC-TOF/MS method, but were quantified by GEMBE
317
at higher concentrations, within an order of magnitude of 0.1 mg/mL.
318 319
Method Comparison: The trends in concentration of sugar-derived compounds are comparable
320
to the trends demonstrated using GCxGC-TOF/MS analysis. Both methods show that higher
321
pretreatment temperatures increase the amounts of glycolic acid, 2-hydroxybutanoic acid, and
322
lactic acid present in the APL. Past work has shown that increasing pretreatment temperatures
323
solubilize more sugars2 thereby increasing the amount of sugar degradation products present in
324
APL. GEMBE analysis of APL samples shows that 3-hydroxypropionic acid (Figure 4), succinic
325
acid, and formic acid (Figure 5) also demonstrate this behavior. Succinic acid and formic acid
326
were not tracked with GCxGC-TOF/MS. The trend observed for 3-hydroxypropionic acid in the
327
GCxGC-TOF/MS method, however, is qualitatively different: the concentration profile plateaus
328
with increasing NaOH loading and is unaffected by increases in pretreatment temperature. It is
329
possible that the discrepancy in the two methods is a result due to a difference LOQ for this
330
relatively low abundance species. Concentrations profiles demonstrating this behavior are
331
suggestive of analytes that do not from originate sugar degradation reactions, but rather are likely
332
from another biomass component that is fully solubilized and degraded. Analytes demonstrating
333
this behavior with GEMBE characterization are acetic acid, glyceric acid, oxalic acid, and malic
334
acid.
335
ACS Paragon Plus Environment
15
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 16 of 37
336
For lignin degradation products, the trend associated with increasing temperature noted using the
337
GCxGC-TOF/MS method is not recapitulated in this report. In our prior study, it was observed
338
that for lower NaOH loading, more p-coumaric acid and ferulic acid were extracted at a process
339
temperature of 130°C. The GEMBE method shows comparable levels of these analytes for both
340
process temperatures across the entire range of treatment severity. The most likely source of this
341
difference is batch-to-batch variability, as the GCxGC-TOF/MS and GEMBE methods were
342
characterized using samples from different process batches. We cannot rule out the possibility
343
that source of the discrepancy was the co-elution of p-coumaric acid with 2-hydroxyisocaproic
344
acid and ferulic acid with catechol and syringic acid. If the extraction of 2-hydroxyisocaproic
345
acid, catechol, or syringic acid increases with temperature, the confounded measurement of the
346
two species by GEMBE could explain the elimination of the difference in extraction at the two
347
treatment temperatures observed by the GCxGC-TOF/MS analysis.
348 349
There were 8 analytes quantified using both methods. All of the analytes quantified show a high
350
degree of correlation between the measurements except 3-hydroxypropionic acid (Figure 6A-C).
351
The presence and nature of bias between the methods is shown with Bland-Altman35 plots
352
(Figure 6D-F). For four of the analytes (ferulic acid, vanillic acid, p-coumaric acid, and 2-
353
hydroxybutanoic acid), including all the lignin derived aromatic compounds, there appears to be
354
some constant bias, with GEMBE giving values on the order of 1 mg/mL higher than the
355
GCxGC-MS method (Figure 6D). The magnitude of this bias is larger for the samples processed
356
at 160°C. For the compounds that are correlated but not comparable, the nature of the bias
357
appears to be proportional to the signal (Figure 6E). The proportionality between the methods
358
indicates that relative changes between samples determined using one method would be
ACS Paragon Plus Environment
16
Page 17 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
359
recapitulated with the other. The samples analyzed were not duplicate samples, but rather
360
process replicates, and the analyses were conducted following different storage protocols prior to
361
analysis. Examination of the role these differences play in the observed bias between the
362
methods is the subject of future work.
363 364
Conclusions
365
In this report, we have demonstrated GEMBE can be used to quantify 17 compounds in APL
366
with a characteristic LOD on the order of 2 µM, and LOQ on the order of 6 µM. We compare the
367
results from our GEMBE characterization of a set of corn stover APL samples to results
368
generated by an orthogonal GCxGC-MS method.4 The analytical performance of the two
369
methods in terms of accuracy and LOD is comparable, but GEMBE offers distinct advantages in
370
terms of analysis time, sample preparation requirements, and cost of equipment. Opportunities to
371
further improve the resolution of the GEMBE method without substantially increasing the
372
analysis time include addition of selective agents and adjustment of BGE pH. Data analysis for
373
GEMBE requires custom written pipelines, which represents a significant effort that is not
374
required for the GCxGC-TOF/MS method. The sensitivity of the non-linear least squares curve
375
fitting to the initial guess for peak position, and peak asymmetry that results from sample
376
stacking play a role in the uncertainty of the measurement. Improvement of these pipelines
377
represents a significant avenue of improvement for future work. GEMBE is further limited in its
378
ability to detect neutral analytes e.g. glycerol. Our ability to detect catechol using our current
379
method suggests that BGE chemistries can be employed that generate complexes of neutral
380
analytes with a charged tag allowing their detection.
381
ACS Paragon Plus Environment
17
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 18 of 37
382
Taken together, the GCxGC-TOF/MS method and GEMBE are powerful companion methods
383
allowing unambiguous identification of target compounds and rapid quantification, respectively.
384
Preliminary characterization of other samples types indicates that GEMBE should be extendable
385
to the other sample types that the GC-based method has been applied to, such as pyrolysis oil,
386
and for tracking bioconversion. Given past success with GEMBE for real-time tracking of
387
chemical reactions, and the fact that dilution is the only preparative step required prior to
388
analysis, it is possible to envision GEMBE-instrumented bioreactors for automated real-time
389
monitoring with a time resolution on the order of the separation time (i.e., 20 minutes).
390 391
Materials and Methods
392
Production of APL: Alkaline pretreatment of corn stover and switchgrass were performed as
393
previously reported.2-3 Briefly, dried stover was loaded into sealed stainless steel vessels at mass
394
fraction of 10% in water. Sodium hydroxide was added at a concentration between 35 mg/g dry
395
stover and 660 mg/g dry stover, matching previous conditions.2 Vessel temperature was elevated
396
to 130°C or 160°C for 30 minutes at temperature. APL samples were aliquoted and stored at 4°C
397
prior to analysis. Repeated analysis of the same sample showed no changes in composition on a
398
time scale of months.
399 400
Preparation of Materials: Standard solutions of potential analytes were prepared at a nominal
401
concentration of 270 mmol/L in either pyridine or reagent grade deionized water (Sigma-
402
Aldrich) as indicated in Table S1. Standard solutions were stored in glass amber vials with PTFE
403
back silicon septa at room temperature. Background electrolyte (BGE) consisted of 250 mmol/L
404
tris(hydroxymethyl)aminomethane (Sigma-Aldrich) and 250 mmol/L boric acid (Sigma-Aldrich)
ACS Paragon Plus Environment
18
Page 19 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
405
and filtered with a 0.2 µm disposable vacuum filtration unit (Thermo). Sodium bromide (Sigma-
406
Aldrich) stock solution was prepared at a concentration of 0.5 mol/L in deionized water. Sample
407
dilution buffer was prepared by diluting the sodium bromide stock solution in BGE to a
408
concentration of 30 µmol/L. APL samples were diluted 100x in sample dilution buffer, these
409
samples were subsequently diluted 10x in sample dilution buffer for a net dilution of 1,000x.
410
Both dilution levels were analyzed for each sample. All analysis was completed with a single
411
batch of BGE. Since signal generation using capacitively coupled contactless conductivity
412
detection is a result of displacement of BGE ions, small batch-to-batch variations in buffer
413
composition can impact the slope and dynamic range of the calibration curve for each analyte.
414 415
Measurement of sample conductivity: The conductivities of diluted samples, BGE, and sample
416
dilution buffer were measured at room temperature using a conductivity meter (LAQUAtwin,
417
Horiba) following the manufacturer’s instructions. Briefly, the sensor was prepared by
418
application of a wetting solution for ten minutes followed by rinsing with deionized water, and
419
calibration using a manufacturer provided standard solution with a nominal conductivity of 1.4
420
mS/cm. The sensor was rinsed with deionized water until the meter read 1 µS/cm or less. The
421
sensor was then rinsed with an aliquot of sample, prior to measurement.
422 423
GEMBE Apparatus: The apparatus for performing GEMBE separations has been described
424
previously22,
425
(McMaster-Carr) to accommodate approximately 200 µL. The BGE reservoir was machined
426
from polyetherimide (LabSmith) to contain 2 mL. The separation channel consisted of a 5 cm
427
long fused silica capillary (Polymicro Technologies) with nominal outer and inner diameters of
30
(Figure 1). The sample reservoir was machined from acetal copolymer
ACS Paragon Plus Environment
19
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 20 of 37
428
360 µm and 10 µm, respectively. The separation channel was inserted approximately 1 mm into
429
the lumen of the sample reservoir through a 360 µm drilled hole, passed through a C4D detector
430
(TraceDec, Innovative Sensor Technologies) and approximately 4 mm into the BGE reservoir
431
through a miniature compression fitting (LabSmith). High voltage (PS350, Stanford Research
432
Systems) was applied using platinum wires inserted into the reservoirs. The polarity of the
433
voltage applied to the buffer reservoir was positive relative to the grounded sample reservoir, so
434
that the direction of electroosmotic flow would be from the BGE reservoir towards the sample.
435
A precision pressure controller (Series 600, Mensor), with air as the supply gas, was used to
436
control the headspace pressure inside the sealed run buffer reservoir. Instrument control and data
437
acquisition was automated using LabView software (National Instruments). The same capillary
438
was used in all experiments without repositioning. Changing or repositioning the capillary can
439
slightly alter the calibration due to shifts in the detection volume relative to the sample reservoir.
440 441
GEMBE Separation Procedures. Samples were removed and/or added to the sample reservoir
442
using a pipette. A 200 µL sample volume was used in all experiments. To prevent carryover
443
between samples, prior to sample loading, the sample reservoir was rinsed three times with 200
444
µL of BGE and once with an aliquot of interest. During sample loading the applied pressure was
445
set to 32 kPa to ensure a flow of run buffer through the capillary and prevent air bubbles. After
446
sample loading, high voltage was applied (2500 V) and the pressure was maintained at 32 kPa
447
for approximately 10 s. The applied pressure was then ramped downward at a rate of 63 Pa/s for
448
900 s. To rapidly rinse the separated sample from the capillary, the pressure was then increased
449
again to 68 kPa, and held for approximately 20 s, after which the high voltage was turned off.
450
The pressure was then set to 32 kPa for 30 seconds prior to evacuating the sample from the
ACS Paragon Plus Environment
20
Page 21 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
451
reservoir. The detector settings were frequency, 2x high; voltage, 0 dB; gain, 200%; offset, 0;
452
filter, slow; and data acquisition rate, 19.8 Hz.
453 454
Calibration: Mixtures were prepared from standard stocks as follows. Six equimolar sub-pools
455
were composed by mixing equal volumes of three standard solutions. Each sub pool consisted of
456
one aqueous standard and two with pyridine as solvent. The assignment into sub-pools was based
457
on elution order in order to maximize the elution time difference between members of a sub-
458
pool; e.g., sub-pool 1 consisted the first (sulfuric acid), seventh (acetic acid), and thirteenth
459
(sulfuric acid) species. Sub-pools were then mixed at fixed ratios using a latin square design (ESI
460
Table SIII), resulting in six calibration pools each with 3 components nominal concentrations of
461
at 30 mmol/L, 24 mmol/L, 18 mmol/L, 12 mmol/L, 6 mmol/L, and 0 mmol/L. The pools were
462
structured such that adjacent analytes were at disparate or comparable levels to enable
463
assessment of crosstalk between analytes. Calibration pools were diluted 100x in sample dilution
464
buffer, these samples were subsequently diluted 10x in sample dilution buffer for a net dilution
465
of 1,000x prior to analysis, resulting in a calibration range for each analyte of 6 µM to 300 µM at
466
10 levels and duplicate null measurements. Calibration curves were collected in full on three
467
different days, along with appropriate blank samples to normalize for stacking. The order of
468
analysis of the calibrants was randomized within a day.
469 470
Data Processing: Data processing pipelines were custom coded in R. Raw electropherograms
471
were converted to peaks for data visualization using a 161-point Savitsky-Golay derivative.
472
Individual steps were modeled as the sum of an error function and a quadratic baseline. Steps
473
were fit individually when there was adequate resolution. Bromide, oxalic acid, formic acid,
ACS Paragon Plus Environment
21
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 22 of 37
474
protocatechuic acid, and acetovanillone were fit as single species. Other analytes were combined
475
into a single zone and fit simultaneously as the sum of the appropriate number of error functions
476
as follows: succinic acid/system peak/malic acid, acetic acid/glycolic acid, 3-hydroxypropanoic
477
acid/lactic acid/glyceric acid, 2-hydroxybutanoic acid/4-hydroxybenzoic acid, vanillic acid/p-
478
coumaric acid, and ferulic acid/impurity/sinapic acid. Steps corresponding to chloride, sulfate,
479
and muconate/carbonate/phosphate were not fit as they were of limited interest. Step heights for
480
each analyte zone were determined for either the 100x or 1,000x dilution sample. Oxalic acid,
481
formic acid, and acetic acid/glycolic acid zones were fit using the 1,000x dilutions. Remaining
482
analytes were determined from the 100x dilution samples. Due to the sensitivity of the parameter
483
algorithm to the initial values, the data processing pipeline supplied graphical summaries of all
484
curve fits. Initial positions and data windows were adjusted as necessary for individual
485
electropherograms until stable representative fits were obtained for all species of interest.
486 487
The height of the bromide step was fit for every sample to compensate for differences in stacking
488
arising from differences in sample conductivity. For each sample the “stacking ratio” was
489
defined as the ratio of the height of the bromide step in the sample to the height of the bromide
490
step in a control sample consisting only of sample dilution buffer (corrected for the small
491
differences in bromide concentration arising from dilution of the sample). The stacking ratio was
492
used to scale the heights determined for each step in the electropherogram. Calibration curves
493
(described above) were used to determine the concentration of each analyte in the diluted
494
sample, which was then scaled by the dilution factor to recover the concentration in the raw
495
sample.
496
ACS Paragon Plus Environment
22
Page 23 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
497
Supporting Information.
498
Measurement error and chemical identification information is included as Supporting
499
Information. This material is available free of charge via the Internet at http://pubs.acs.org.
500
Corresponding Author
501
Gregg T. Beckham
502
*Email
[email protected] 503
Funding Sources
504
EMK, CTN, and GTB thank the U.S. Department of Energy Bioenergy Technologies Office
505
(DOE-BETO) for funding via Contract No. DE-AC36-08GO28308 with the National Renewable
506
Energy Laboratory.
507
Acknowledgements
508
MSM and MS would like to acknowledge Drew Endy and Christina Smolke for graciously
509
hosting this work in their laboratories, Stephanie Galanie for logistical support, Sarah Munro,
510
Ariel Hecht, and Jerod Parsons for useful support in the construction of data analysis pipelines,
511
and Scott Pine for assistance in designing calibration pools. The U.S. Government retains and the
512
publisher, by accepting the article for publication, acknowledges that the U.S. Government
513
retains a nonexclusive, paid up, irrevocable, worldwide license to publish or reproduce the
514
published form of this work, or allow others to do so, for U.S. Government purposes. Certain
515
commercial equipment, instruments, or materials are identified in this report to specify
516
adequately the experimental procedure. Such identification does not imply recommendation or
517
endorsement by the National Institute of Standards and Technology, nor does it imply that the
518
materials or equipment identified are necessarily the best available for the purpose.
ACS Paragon Plus Environment
23
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 24 of 37
519
References
520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563
1. Sjöström, E.; Alén, R., Analytical Methods in Wood Chemistry, Pulping, and Papermaking. Springer: Berlin, New York, 1999. 2. Karp, E. M.; Donohoe, B. S.; O'Brien, M. H.; Ciesielski, P. N.; Mittal, A.; Biddy, M. J.; Beckham, G. T., Alkaline Pretreatment of Corn Stover: Bench-Scale Fractionation and Stream Characterization. ACS Sust. Chem. Eng. 2014, 2 (6), 1481-1491. 3. Karp, E. M.; Resch, M. G.; Donohoe, B. S.; Ciesielski, P. N.; O'Brien, M. H.; Nill, J. E.; Mittal, A.; Biddy, M. J.; Beckham, G. T., Alkaline Pretreatment of Switchgrass. ACS Sust. Chem. Eng. 2015, 3 (7), 1479-1491. 4. Karp, E. M.; Nimlos, C. T.; Deutch, S.; Salvachua, D.; Cywar, R. M.; Beckham, G. T., Quantification of Acidic Compounds in Complex Biomass-Derived Streams. Green Chem. 2016. 5. Beckham, G. T.; Johnson, C. W.; Karp, E. M.; Salvachua, D.; Vardon, D. R., Opportunities and Challenges in Biological Lignin Valorization. Curr. Opin. Biotech. 2016, 42, 40-53. 6. Linger, J. G.; Vardon, D. R.; Guarnieri, M. T.; Karp, E. M.; Hunsinger, G. B.; Franden, M. A.; Johnson, C. W.; Chupka, G.; Strathmann, T. J.; Pienkos, P. T.; Beckham, G. T., Lignin Valorization through Integrated Biological Funneling and Chemical Catalysis. Proc. Natl. Acad. Sci. USA 2014, 111 (33), 12013-12018. 7. Salvachua, D.; Karp, E. M.; Nimlos, C. T.; Vardon, D. R.; Beckham, G. T., Towards Lignin Consolidated Bioprocessing: Simultaneous Lignin Depolymerization and Product Generation by Bacteria. Green Chem. 2015, 17 (11), 4951-4967. 8. Vardon, D. R.; Franden, M. A.; Johnson, C. W.; Karp, E. M.; Guarnieri, M. T.; Linger, J. G.; Salm, M. J.; Strathmann, T. J.; Beckham, G. T., Adipic Acid Production from Lignin. Energy Env. Sci. 2015, 8 (2), 617-628. 9. Käkölä, J. M.; Alén, R. J.; Isoaho, J. P.; Matilainen, R. B., Determination of LowMolecular-Mass Aliphatic Carboxylic Acids and Inorganic Anions from Kraft Black Liquors by Ion Chromatography. J Chromatography A 2008, 1190 (1), 150-156. 10. Kuban, P.; Karlberg, B., On-Line Monitoring of Kraft Pulping Liquors with a Valveless Flow Injection–Capillary Electrophoresis System. Analytica chimica acta 2000, 404 (1), 19-28. 11. Masselter, S. M.; Zemann, A. J.; Bonn, G. K., Determination of Inorganic Anions in Kraft Pulping Liquors by Capillary Electrophoresis. Journal of High Resolution Chromatography 1996, 19 (3), 131-136. 12. Salomon, D. R.; Romano, J., Applications of Capillary Ion Electrophoresis in the Pulp and Paper Industry. Journal of Chromatography A 1992, 602 (1), 219-225. 13. Sullivan, J.; Douek, M., Analysis of Hydroxide, Inorganic Sulphur Species and Organic Anions in Kraft Pulping Liquors by Capillary Electrophoresis. J Chromatography A 2004, 1039 (1), 215-225. 14. Volgger, D.; Zemann, A.; Bonn, G., Determination of Phenols, Inorganic Anions, and Carboxylic Acids in Kraft Black Liquors by Capillary Electrophoresis. Journal of High Resolution Chromatography 1998, 21 (1), 3-10. 15. Ross, D., Step Width, Spacing, and Resolution in Gradient Elution Moving Boundary Electrophoresis. Part 1. Theory and Comparison with Zone Electrophoresis. Electrophoresis 2010, 31 (22), 3650-3657. 16. Ross, D., Step Width, Spacing, and Resolution in Gradient Elution Moving Boundary Electrophoresis. Part 2. Results from Experiment. Electrophoresis 2010, 31 (22), 3658-3664.
ACS Paragon Plus Environment
24
Page 25 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609
ACS Sustainable Chemistry & Engineering
17. Shackman, J. G.; Munson, M. S.; Ross, D., Gradient Elution Moving Boundary Electrophoresis for High-Throughput Multiplexed Microfluidic Devices. Anal. Chem. 2007, 79 (2), 565-571. 18. da Silva, J. A. F.; do Lago, C. L., An Oscillometric Detector for Capillary Electrophoresis. Anal. Chem. 1998, 70 (20), 4339-4343. 19. Guijt, R. M.; Evenhuis, C. J.; Macka, M.; Haddad, P. R., Conductivity Detection for Conventional and Miniaturised Capillary Electrophoresis Systems. Electrophoresis 2004, 25 (2324), 4032-4057. 20. Zemann, A. J.; Schnell, E.; Volgger, D.; Bonn, G. K., Contactless Conductivity Detection for Capillary Electrophoresis. Anal. Chem. 1998, 70 (3), 563-567. 21. Brito-Neto, J. G. A.; da Silva, J. A. F.; Blanes, L.; do Lago, C. L., Understanding Capacitively Coupled Contactless Conductivity Detection in Capillary and Microchip Electrophoresis. Part 1. Fundamentals. Electroanalysis 2005, 17 (13), 1198-1206. 22. Flanigan, P. M.; Ross, D.; Shackman, J. G., Determination of Inorganic Ions in Mineral Water by Gradient Elution Moving Boundary Electrophoresis. Electrophoresis 2010, 31 (20), 3466-3474. 23. Kralj, J. G.; Munson, M. S.; Ross, D., Total Protein Quantitation Using the Bicinchoninic Acid Assay and Gradient Elution Moving Boundary Electrophoresis. Electrophoresis 2014, 35 (12-13), 1887-1892. 24. Strychalski, E. A.; Henry, A. C.; Ross, D., Expanding the Capabilities of Microfluidic Gradient Elution Moving Boundary Electrophoresis for Complex Samples. Anal. Chem. 2011, 83 (16), 6316-6322. 25. Ross, D.; Kralj, J. G., Simple Device for Multiplexed Electrophoretic Separations Using Gradient Elution Moving Boundary Electrophoresis with Channel Current Detection. Anal. Chem. 2008, 80 (24), 9467-9474. 26. Ross, D.; Romantseva, E. F., Gradient Elution Moving Boundary Electrophoresis with Channel Current Detection. Anal. Chem. 2009, 81 (17), 7326-7335. 27. Sikorsky, A. A.; Fourkas, J. T.; Ross, D., Gradient Elution Moving Boundary Electrophoresis with Field-Amplified Continuous Sample Injection. Analytical Chemistry 2014, 86 (7), 3625-3632. 28. Ross, D.; Munson, M. S., Gradient Elution Moving Boundary Electrophoresis with Channel Current Detection in Relatively Long Capillaries. Electrophoresis 2014, 35 (5), 770776. 29. Ross, D.; Shackman, J. G.; Kralj, J. G.; Atencia, J., 2d Separations on a 1d Chip: Gradient Elution Moving Boundary Electrophoresis-Chiral Capillary Zone Electrophoresis. Lab Chip 2010, 10 (22), 3139-3148. 30. Strychalski, E. A.; Henry, A. C.; Ross, D., Microfluidic Analysis of Complex Samples with Minimal Sample Preparation Using Gradient Elution Moving Boundary Electrophoresis. Anal. Chem. 2009, 81 (24), 10201-10207. 31. Munson, M. S.; Danger, G.; Shackman, J. G.; Ross, D., Temperature Gradient Focusing with Field-Amplified Continuous Sample Injection for Dual-Stage Analyte Enrichment and Separation. Anal. Chem. 2007, 79 (16), 6201-6207. 32. Fuchs, G.; Boll, M.; Heider, J., Microbial Degradation of Aromatic Compounds - from One Strategy to Four. Nat. Rev. Microbiol. 2011, 9 (11), 803-816. 33. Boeseken, J., The Use of Boric Acid for the Determination of the Configuration of Carbohydrates. Adv. Carb. Chem. 1949, 4, 189-210.
ACS Paragon Plus Environment
25
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
610 611 612 613 614
Page 26 of 37
34. Zittle, C. A., Reaction of Borate with Substances of Biological Interest. Advances in Enzymology and Related Subjects of Biochemistry 1951, 12, 493-527. 35. Altman, D. G.; Bland, J. M., Measurement in Medicine - the Analysis of Method Comparison Studies. Statistician 1983, 32 (3), 307-317.
ACS Paragon Plus Environment
26
Page 27 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
615
Figure 1: Schematic representation of GEMBE. A separation capillary bridges reservoirs containing sample and background electrolyte (BGE). The BGE reservoir is pressure controlled, in order to tune bulk flow, which is directed from the BGE reservoir towards the sample. As the applied pressure is reduced, electrophoresis of sample ions is able to overcome convection at the capillary inlet, and ions elute into the capillary in order of decreasing mobility. 616 617
ACS Paragon Plus Environment
27
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 28 of 37
Figure 2: Representative electropherogram from separation of corn stover APL using GEMBE (A). The heights of the steps in the raw detector signal are proportional to the concentration of species eluting at that step. To facilitate visual inspection and identification of step positions, the derivative of the detector signal is calculated (B,C). Labeled steps have been identified by spiking standards of compounds identified by orthogonal analyses of similar samples, and are detailed in Table 1.4 Unknown peaks are labeled U and system peaks are labeled S. 618
ACS Paragon Plus Environment
28
Page 29 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
Table 1: Correspondence between analyte and step number
Step Number
Compound
1
oxalic acid
2
formic acid
3
succinic acid
4
malic acid
5
muconic acid
6
acetic acid
7
glycolic acid
8
protocatechuic acid
9
propionic acid
10
3-hydroxypropionic acid
11
lactic acid
12
glyceric acid 2-hydroxybutanoic acid
13 salicylic acid 14
4-hydroxybenzoic acid vanillic acid
15 gluconic acid vanillic acid 16 2-hydroxyisocaproic acid ferulic acid syringic acid 17 catechol vanillin 18
sinapic acid
19
acetovanillone
619 620 621
ACS Paragon Plus Environment
29
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 30 of 37
Table 2: Limit of detection and limit of quantification for analytes LOD
LOQ
Analyte
μmol/L
mg/mL
μmol/L
mg/mL
oxalic acid
1.05
0.09
3.51
0.31
formic acid
2.49
0.11
8.29
0.37
succinic acid
1.26
0.15
4.19
0.49
malic acid
2.12
0.28
7.06
0.93
acetic acid
1.61
0.09
5.36
0.32
glycolic acid
2.27
0.17
7.56
0.57
protocatechuic acid
1.26
0.19
4.20
0.65
3-hydroxypropionic acid
2.00
0.18
6.66
0.60
lactic acid
2.00
0.18
6.66
0.60
glyceric acid
1.95
0.21
6.49
0.69
2-hydroxybutanoic acid
2.27
0.20
7.55
0.68
4-hydroxybenzoic acid
1.12
0.15
3.73
0.51
vanillic acid
3.57
0.65
6.11
1.11
p-coumaric acid
1.87
0.30
6.22
1.02
ferulic acid
0.86
0.17
2.88
0.56
sinapic acid
2.45
0.55
8.16
1.82
acetovanillone
2.34
0.39
7.81
1.30
622 623
ACS Paragon Plus Environment
30
Page 31 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
Figure 3: The four most abundant lignin degradation products p-coumaric acid (A), ferulic acid (B), and vanillic acid (C), and 4-hydoxybenzoic acid (D) are quantified as a function of
ACS Paragon Plus Environment
31
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 32 of 37
pretreatment severity. Corn stover pretreatments were performed for 30 minutes at temperatures of 130°C and 160°C over NaOH loadings ranging from 35 to 660 mg/g dry stover. A replicate of this figure with mmol/L units is shown in Figure S5. Error bars are the standard deviation of three replicate measurements conducted on different days.
Figure 4: Hydroxyacid products resulting primarily from sugar degradation reactions and extractives in the alkaline media during pretreatment are quantified and tracked as a function of pretreatment severity that were also tracked using the GCxGC-TOF/MS-based method.4 General trends are seen in that increasing pretreatment temperature creates more glycolic acid (A), 2hydroxybutanioc acid (B), 3-hydroxypropionic acid (C), and lactic acid (D) in the APL sample. Glyceric acid (E) production was not effected by temperature, but does increase with hydroxide loading. A replicate of this Figure with mmol/L units is shown in Figure S6. Error bars are the
ACS Paragon Plus Environment
32
Page 33 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
standard deviation of three replicate measurements conducted on different days. 624
Figure 5: Hydroxyacid products resulting primarily from sugar and extractives degradation reactions in the alkaline media during pretreatment, are quantified and tracked as a function of pretreatment severity. These compounds could not be tracked using the GCxGC-TOF/MS-based method.4 General trends are seen in that increasing pretreatment temperature creates more succinic acid (A) and formic acid (B) in the APL sample. Oxalic acid (C) production was not effected by temperature, but does increase with hydroxide loading. Acetic acid (D) and malic acid (E) production were not observed to be a strong function of either temperature or hydroxide loading. A replicate of this Figure with mmol/L units is shown in Figure S7. Error bars are the
ACS Paragon Plus Environment
33
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 34 of 37
standard deviation of three replicate measurements conducted on different days. 625 626
ACS Paragon Plus Environment
34
Page 35 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
Figure 6: Comparison of measured concentrations for analytes quantified using both the GCxGC-TOF/MS and GEMBE methods. Results from the two methods are correlated for glyceric acid, glycolic acid, and lactic acid (A) comparable for p-coumaric acid, ferulic acid, vanillic acid, and 2-hydroxybutanoic acid (B) but not well correlated for 3-hydroxypropionic acid (C), and. The nature of the bias between the two methods is demonstrated using BlandAltman plots. Ferulic acid, p-coumaric acid, vanillic acid, and 2-hydroxybutanoic acid show constant bias that is temperature dependent (D) while lactic acid, glycolic acid, and glyceric acid each demonstrate proportional bias (E). Differences are calculated by subtracting GEMBE values from GCxGC-TOF/MS values. Error bars are the standard deviation of three replicate
ACS Paragon Plus Environment
35
ACS Sustainable Chemistry & Engineering
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 36 of 37
measurements conducted on different days. 627
ACS Paragon Plus Environment
36
Page 37 of 37
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Sustainable Chemistry & Engineering
628
For Table of Contents Use Only
629
Title: Gradient Elution Moving Boundary Electrophoresis enables rapid analysis of acids in
630
complex biomass-derived streams
631
Authors: Matthew S. Munson, Eric M. Karp, Claire T. Nimlos, Marc Salit, and Gregg T.
632
Beckham
633
Synopsis
634
GEMBE is able to rapidly and efficiently quantify multiple compounds in complex biomass
635
streams with little to no expensive equipment.
636 637
TOC Figure.
638 639 640 641
ACS Paragon Plus Environment
37