Rheodyne, Inc

service, phone (415) 548 5374. ... which usually requires two pump systems of the conventional type. Typical ... Siemens AG, Postfach 3240, D-8520...
1 downloads 0 Views 859KB Size
New Products

Our new HPLC Columns ore well pocked! Guaranteed peak symmetry and minimum plates per meter doubly assure you of optimum column performance. A completely new line of "stateof the-art" packed columns for high pressure liquid chromatography is now available in the U.S. and Canada from Rheodyne. All columns are 4.6 mm ID χ 25 cm long. Each column is tested and supplied with its own chromatogram. Currently six columns are available over a price range of $180 to $240. The table below showing column performance specifications and typical test conditions offers an excellent argument for the addition of these columns to your HPLC equipment. COLUMN TYPE Particle size

SI-100·

NHÎ

DIOL

RP-8·

10 Mm

5 μΠΊ

5 μΓη

10 μτη

M in. plates per meter

36,000

14,000

Max. peak asymmetry

1.6

1.6

1.6

This high-pressure liquid chromatograph uses a new type of three-rotor piston pump that delivers greatly reduced, nearly pulse-free, continuous liquid stream volumes. The new pumping system is called Tri Rotar. Because of its unique design, one single pump can be used for gradient work which usually requires two pump systems of the conventional type. Typical pump outputs range from 0.1 to 9.9 mL/min in 0.1-mL/min steps with a flow accuracy of 1 %. Operation is at 7100 psig with automatic overpressure cutoff. A wide variety of columns, detectors, and other ac­ cessories are available with the Tri Rotar for different applications. Jasco Inc. 404

Nd:YAG Laser Systems The DCR series features a proprietary unstable resonator design that results in very high output energies in a pulsed 1064-nm beam having diffraction-limit­ ed divergence characteristics. The Model DCR-1A (oscillator and amplifier) produces over 500 m j in a 10-ns pulse

at a repetition rate variable from 2 to 20 pps. Provision is made for input and output signal synchronization allowing maximum experimental flexibility. The Model DCR-1 (oscillator only) produces in excess of 150 mJ/pulse in a diffrac­ tion-limited beam. Priced at $33 000 and $23 0 0 0 , respectively. Quanta-Ray, Inc. 420

26.000

Solvent

hexane

hexane

hexane

4 0 % ace tonitrile

Flow, ml/min

2.0

2.0

2.0

2.0

Pressure, psi

1640

280

280

3000

Test substance

nitrobenzene

nitrobenzene

nitrobenzene

diethyl phthalate

'available in 10 μπ\ particle size also, " u n d e r evaluation

Made by Brownlee Labs, the columns are guaranteed by both Brownlee and Rheodyne. Column packings are LiChrosorb (a registered T. M. of E. Merck Darmstadt Germany). For More Information. A detailed technical brochure is available for the asking. Address Rheodyne, Inc., 2809 Tenth Street, Berkeley, CA 94710. For even faster service, phone (415) 548 5374.

RHEODYNE

The combined gas chromatograph/mass spectrometer system features a quadrupole mass spectrometer that can be linked with any type of gas chromatograph. The mass spectrometer system is made up of completely digitized, binary-coded functional units and is designed for connection to a computer. An open coupler is used for connection to chromatographic columns. Gas chromatograms can be recorded simultaneously and independently of each other. A detector and filter permit independent measurement of the total ion flow and mass spectrum out of one specimen stream, thus permitting unique correlation without loss in information. All setting parameters for the control console, the internal memory, and the external process computer are jointly transmitted via an information bus. Siemens AG, Postfach 3240, D-8520 Erlangen 2, Federal Republic of Germany

CIRCLE 180 ON READER SERVICE CARD 336 A · ANALYTICAL CHEMISTRY, VOL. 49, NO. 3, MARCH 1977