Salvaging of Silver Chloride Windows - ACS Publications

Salvaging of Silver Chloride Windows. Warren C. Schwemer, John E. Murphy, and Lee Williamson, Research and. Development Division, S. C. Johnson & Son,...
1 downloads 0 Views 2MB Size
Salvaging of Silver Chloride Windows Worren C. Schwemer, John E. Murphy, and l e e Williamson, Research and Development Division, S. C. Johnson & Son, Inc., Racine, Wis.

c

silver chloride windows used in infrared spectroscopy [Fuoss, R. M., Rev. Sei. Instr. 16, 154-5 (1945)) usually have a short life expectancy, as they are easily scratched and darken on exposure to light. These sil3er chloride windows, being insoluble in water, make possible the determination of the infrared spectra of wax and polymer films deposited on the silver chloride windows from water emulsions. A technique has been developed which restores these silver chloride plates to their original transparency and thus lengthens their life expectancy severalfold (Figure 1). The change in the absorbance of the silver chloride disk before and after treatment is shown in Figure 2. OSTLY

Pittsburgh Conference and the Anilysl

Figure 1.

coarseness. The window is then immersed in concentrated ammonium hydroxide for about 2 minutes, rinsed with water, and rnhhed dry with a lintless cloth. This ammonia treatment removes any layer of reduced silver which may have been present on the surface of the window [Giesecke, P., Colthup, N. B. (to American Cyanamid Co.), U. S. Patent 2,528,224 (Oct. 31, 1950)l. To remove the surface scratches from the windows, advantage is taken of the fact that silver chloride will flow under pressure. The windows are placed in a polished, chrome-surfaced die, l'/s inches in diameter, and pressed at a pressure of 8000 pounds per square inch. The die used for this purpose is a Carver test cylinder (Figure 3), the faces of which have been ground, lapped, and chrome-plated. The press used was a Carver laboratory press which was purchased for use in forming potassium bromide pellets. For use in PerkinElmer cells the pressed windows are trimmed with a 1-inch-diameter punch.

Silver chloride windows Leff. Dornoged Right. Salvaged

To restore these silver chloride disks to their original transparency, surface scratches and foreign material which may have reacted with the silver chloride must be removed. The foreign material is first removed from the silver chloride by scraping the surface of the window with a single-edge razor blade and sanding with No. 600-A wet-dry sandpaper or other paper of similar

Figure 3. Die used for removing scratches from silver chloride window

Bulb Tube Assembly for Vacuum Distillation Anthony W. Schrecker, Laboratory of Chemical Pharmocology, National Cancer Institute, Nationol Institutes of Health, Public Health Service, Bethesda

14, Md.

described is a modiT fication . of Kober's bulb tube [S. HE APP.%RATUS

Kober, Biochem. Z. 232, 274 (1931)], which has been used extensively for vacuum distillation and sublimation of small quantities. In its original form, it consists of three or more bulbs fused together by pieces of glass tubing. Figure 1 shows the design of the assembly. The bulbs, which may be constrncted from borosilicate glass round-bottomed flasks, are connected by means of B 14/35 standard-taper drip-tip ground joints (for which 14/20 joints could be substituted advantageously). Adapter D connects the assembly with the vacuum system hy rubber tubing. In operation, the distilland, dissolved if necessary in a solvent, is introduced into flask A . The solvent is evaporated in vacuo, most conveniently by use of a rotating evaporator (Rinco Instrument Co., Greenville, Ill.), to which the flask is attached by means of an enlarging adapter (19/38 outer, 14/35 inner joint). Parts A, B, C, and D are then assembled in series, clamped horizontally, and flask A and the adjoining length of tubing are inserted into a heating oven (FigureT2), so that bulb B iust Drotrudes. Tube D is attached to the Gacuum system, and the oven heated gradually. The distillate collects in B. By further inserting the assembly so that only bulb C protrudes from the oven, part or all of the material can be redistilled and some fractionation accomplished. The heating oven consists of a Transite box enclGed in an aluminum shell, 32 X 14 X 14 em., the space in between the two filled with rock wool. The

M

0s

01

e,

a-:

% ,

-..g: J

03 06

0.

DI

01

I I. 0

0.

a.

,o I

"S ..

Figure 2.

. I

_ I

," c * m

mw "m.

Infrared spectra of silver chloride window before (bottom) and after (top) treatment VOL 29. NO. 7, JULY 1957

11 13