SCHLUMBERGER WELL SURVEYING ... - ACS Publications

May 16, 2012 - SCHLUMBERGER WELL SURVEYING CORPORATION. Anal. Chem. , 1958, 30 (8), pp 71A–71A. DOI: 10.1021/ac60140a771. Publication ...
0 downloads 0 Views 199KB Size
NEW PRODUCTS modified to meet specific requirements. Weight is about 170 pounds, diameter is 18 inches, and height is 17 inches. The controls weigh about 10 pounds. P-21

Moisture Monitor

This Chemist has more time for Valuable Research thanks to the SCHLUMBERGER NMR Analyzer The remarkable simplicity of the Schlumberger Model 104 NMR Analyzer allows routine moisture determination by non­ technical personnel, freeing the chemist from humdrum labor and giving him more time for creative work. Nothing approaches the speed and accuracy of this new form of spectrography based on the principle of nuclear magnetic resonance. Once the instru­ ment is set up, just put in a sample, throw a switch, and read a scale—in less than a min­ ute your moisture determination is finished. The wide range of operational parameters of the Model 104 makes it, in the hands of a research chemist, a sophisticated analytical instrument for probing the make-up of matter. Schlumberger NMR analysis is non­ destructive, and the large, 40-cc sample size allows high sampling accuracy. Results are reproducible to within parts per thousand, and accuracy of 0.1 %, absolute, can be main­ tained. Industries where large numbers of moisture determinations are necessary can save considerably through the release of tech­ nical personnel for more valuable research with the very same instrument. For complete information, including the lat­ est material-study reports, and the address of your local Schlumberger Distributor-Service Organization, write to Department AC-7. RIDGEFIELD INSTRUMENTATION

DIVISION

SCHLUMBERGER WELL

S U R V E Y I N G

C O R P O R A T I O N

Ridgefield,

Connecticut

The Type 26-302 moisture monitor introduced by Consolidated Electrody­ namics Corp. measures minute quanti­ ties of water in gaseous mixtures. It measures accurately, according to the company, down to 10 p.p.m. full scale. And it permits meter readings over the range zero to 20,000 p.p.m. by means of a six-position attenuator. Output can be telemetered to a remote recorder for monitoring or control. In operation, an electrolysis cell con­ tinuously absorbs and electrolyzes all water present in a sample stream. A d.c. voltage is applied to the elements of the cell and the electrolysis current measured with a multirange meter. The electrolysis current, related di­ rectly to the mass rate of flow of water into the instrument, is an indication of water content. The instrument operates on 50/60 cycles, 105/125 volts, and normal line transients are said not to affect opera­ tion. Sample flow, at temperatures up to 100° C. and pressures of 10 to 40 p.s.i.g., are controlled at a selectable rate of· about 20 cc./min. A battery pack permits use where electric power is not available. P-22

Shadow Indicating Scale A gradient and calibration system of new design and assuring true linearity of calibration is a feature claimed for Pennsylvania Scale Co.'s Model 501 Pennograph. Gradient is supplied by two temperature compensated coil ten­ sion springs mounted in opposition on equal lever arms from the lever ful­ crum point. The springs, having a large number of coils and large outside diameter, are designed so that each coil deflects only a minute amount. This, as opposed to ordinary flat leaf flex design, assures a true linearity of cali­ bration, according to the company. The scale comes in five models with capacities from 100 grams to 1500 grams, and can be supplied in the metric or avoirdupois system. Sensi­ tivity is said to be 50 mg. to 400 mg, depending on the model chosen. The company also says the scale has an im­ proved optical system which eliminates parallax and provides easier reading of values. P-23

VITREOSIL

®

FUSED Q U A R T Z

MEETS YOUR CRITICAL REQUIREMENTS

CHECK WHAT VITREOSIL OFFERS: Absolute Chemical Purity Extreme Heat Resistance Thermal Shock Resistance Chemical Inertness Outstanding Electrical Properties Full-Range Radiant Energy Transmission

VITREOSIL fused quartz prod­ ucts can be supplied in an un­ usually large variety of types and sizes. Also fabricated to specification to meet semi-con­ ductor requirements.

TRANSPARENT VITREOSIL For u l t r a - v i o l e t a p p l i c a t i o n s , metallurgical investigations and processes, chemical research and analysis, photochemistry, spec­ troscopy and physical, optical and electrical research and pro­ duction operations. Send specifi­ cations for your requirements. Please use coupon below. See our ad in Chemical Engineering Catalog THERMAL A M E R I C A N FUSED Q U A R T Z C O . , I N C . 18-20 Salem Street, Dover, N e w Jersey

Please send technical d a t a on

Company N a m e & Title_

For f u r t h e r details, see ERS' I N F O R M A T I O N SERVICE f o l l o w i n g this section Circle Να. 71 A-1 on Readers' Service Card, page 77 A

Street City

_Zone_

_State_

C i r c l e N o . 71 A-2 on Readers' s e r v i c e Card, page 77 A

VOL 30, NO. 8, AUGUST 1958

·

71

A