I N T R O D U C I N G NEW HPLC Systems from Scientific Systems, Inc.
Designed to be precise, reliable and affordable. High-quality, modular systems with upgradability in mind. We have served the HPLC market for over 21 years and are proud to introduce five completely new systems. Our new 402 series features 3 personal computer-based systems for high and low pressure binary and ternary gradients. The 401 series is a keypad-based system for high pressure binary gradient or low pressure binary/ternary gradients. Our 520 is a research-grade, variable wavelength isocratic system.
PITTCON 1:50 (1203) Modified Phase Correction Algorithms In VCD/FT-IR Spectrometry—C.A. McCOY, University of Georgia, J.A. de Haseth 2:10 (1204) The Application of Resolution Enhancement Techniques to the Study of Factors Affecting Group Frequencies—II. Coupling of Symmetric Methyl Deformation Vibrations In Dlmethylcyclohexanes—D.W. MAYO, Bowdoin College, C.S. Dinsmore, G.T. Merklin, R.W. Hannah 2:30 (1205) Some Special Quality Control Applications of FT-IR—RE. KLEBBA, Nicolet Instrument Corp., Inc., W.M. Grim, III 2:50 (1206) Elimination of Instrumental Artifacts from FT-IR Spectra—RE. FIELDS, III, University of Oklahoma, R.L. White 3:10 RECESS 3:25 (1207) What Price Sensitivity In an FTIR Experiment?—R.O. CARTER. Ill, Ford Motor Company, M.C. Paputa-Peck 3:45 (1208) A New Scanning Method for a Mid-Infrared FT-IR Spec trometer—R. RUBIN0VITZ, Bruker Instruments. Inc., A. Simon, M.A. Finch 4:05 (1209) Fourier Transform IR/UV-VIs Spectroscopy Using Step & Integrate Interferometry. Part I. Instrumentation and Theory—C.J. MANNING, Duke University, M.J. Smith, R.A. Palmer, J.L. Chao 4:25 (1210) Fourier Transform IR/UV-VIs Spectroscopy Using Step & Integrate Interferometry. Part II. Applications and Theory—J.L. CHAO, IBM Corporation, C.J. Manning, M.J. Smith, R.A. Palmer 4:45 (1211) New Uses of Photoacoustic Detection In FTIR Spectroscopy— J.F. McCLELLAND, Iowa State University, L.M. Seaverson, S.M. Kaushik
Laboratory Information Management Systems If your plans include a new HPLC system, call toll free 1-800-441-4752, in Pennsylvania, call 814-234-7311, or write to Scientific Systems, Inc., 1120 West College Avenue, State College, PA 16801.
Thursday Afternoon, Room 4/5, Rivergate P. Seelig, Presiding Merck and Company
SSI CIRCLE 156 ON READER SERVICE CARD
R I V Ε R G A Τ Ε
Fun Physical Science Activities for Children and Adults to Do Together • • • • •
colorful comic book format useful at home or in classrooms reinforces language and math skills relates science concepts to technology aimed at 4th through 6th graders Price per subscription (one-year, four-issues)
To continental US. addresses
Tc> addresses outside the continental LIS.
For subscription information write or call:
1-4 5_]9
$ 3 .oo
20 or more
$2.00 each
$4.00 each each
50 or more (minimum)
$3.00 each
American Chemical Society Prehigh School Science Program 1155 Sixteenth St., N.W. Washington, DC 20036 (202)452-2113
1:30 (1212) The Use of a LIMS System In the Process Control Laboratory in the Metals Industry—J. KIKKERT, Comlabs Systems and Designs 1:50 (1213) High Performance Laboratory Network Communica tions tor Distributed Processing—S.C. GATES, IBM T.J. Watson Research Center 2:10 (1214) LIMS: A High Volume Quality Control Laboratory with Data Transfer to a Mainframe Computer—C.W. MORRIS, IMC Fertilizer, Inc., C.W. Wilks 2:30 (1215) Introduction of a New Computer Analysis Package for Time-Temperature Superposition of Polymers—S.R. FARBER, Rheometrics, Inc. 2:50 (1216) A Customized LIMS tor a PC Workstation—BR. BEAR, 3M Company, P. Ihrig 3:10 RECESS 3:25 (1217) Data Management and Reporting for the Mass Spec Lab—N. LOW, Hewlett-Packard Company 3.45 (1218) A UNIX Based LMS (Laboratory Management System) tor the Small to Medium Sized Laboratory—L.K HALV0RSEN, Northwest Analytical, Inc., L.M. Kary, F.J. Barberis 4:05 (1219) Laboratory Management Using Commercial Software Products—J.L. CAWLEY, Northwest Analytical, Inc., D. Dickson, D. Shearer 4:25 (1220) Modern Database Technology Applied to Laboratory Information Management—D.P. BEGGS, Nelson Analytical, M.A. Ratcliff 4:45 (1221) Automated Analyses Using a Distributed Laboratory Network—F.W. K0ESTER, Spectra-Physics, Inc., TA. Rooney
Liquid Chromatography—Environmental, Organic and Fuel Applications Thursday Afternoon, Room 23/25, NOCC ft. Gilpin, Presiding Kent State University 1:30 (1222) Liquid Chromatographic Separation of Chlorophenols and Chloroblphenylols (PCB Metabolites) Using a β-Cyclodextrin Column—M. PALE0L0G0U, McGill University, W.C. Purdy 1:50 (1223) HPLC Fractionation Procedure for the Analysis of Dloxlns, Furans, and Other Polychlorlnated Pollutants In Fish Tissue Extracts—Τ S THOMPSON, University of Waterloo, K.P. Naikwadi, F.W. Karasek 2:10 (1224) Desorption from Carbon Blacks Into Synthetic Alveolar Surfactant and Zwltterionic Micelles—S.S SEHNERT, The Johns Hopkins Univer sity, T.H. Risby 2:30 (1225) Quantitative Group-Type Analysis of Diesel Fuels Using a Hydrocarbon Group-Type Analyzer System—S.D. ANDERSON, AFWAL/POSF. P.C. Hayes, Jr.
224 A · ANALYTICAL CHEMISTRY, VOL. 60, NO. 3, FEBRUARY 1, 1988