Sequential Measurement of Intermodal Variability ... - ACS Publications

May 16, 2016 - Hong Kong is an example of a city heavily reliant on public transport. In Hong Kong, 12 million public transport passenger journeys are...
0 downloads 0 Views 1MB Size
Subscriber access provided by the University of Exeter

Article

Sequential Measurement of Intermodal Variability in Public Transportation PM and CO Exposure Concentrations 2.5

Wenwei Che, H. Christopher Frey, and Alexis K. H. Lau Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.6b01594 • Publication Date (Web): 16 May 2016 Downloaded from http://pubs.acs.org on June 4, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 39

Environmental Science & Technology

SEQUENTIAL MEASUREMENT OF INTERMODAL VARIABILITY IN PUBLIC TRANSPORTATION PM2.5 AND CO EXPOSURE CONCENTRATIONS

W. W. Che,1 H. Christopher Frey,1,2,3 Alexis K.H. Lau1,2,* 1

Division of Environment, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China 2 Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China 3 Department of Civil, Construction and Environmental Engineering, North Carolina State University, Campus Box 7908, Raleigh, North Carolina 27695-7908, United States

1

ACS Paragon Plus Environment

Environmental Science & Technology

1 2

ABSTRACT A sequential measurement method is demonstrated for quantifying the variability in exposure

3

concentration during public transportation. This method was applied in Hong Kong by

4

measuring PM2.5 and CO concentrations along a route connecting 13 transportation-related

5

microenvironments within three-to-four hours. The study design takes into account ventilation,

6

proximity to local sources, area-wide air quality and meteorological conditions. Portable

7

instruments were compacted into a backpack to facilitate measurement under crowded

8

transportation conditions and to quantify personal exposure by sampling at nose level. The route

9

included stops next to three roadside monitors to enable comparison of fixed site and exposure

10

concentrations. PM2.5 exposure concentrations were correlated with the roadside monitors,

11

despite differences in averaging time, detection method and sampling location. Although highly

12

correlated in temporal trend, PM2.5 concentrations vary significantly among microenvironments,

13

with mean concentration ratios versus roadside monitor ranging from 0.5 for MTR train to 1.3

14

for bus terminal. Measured inter-run variability provides insight regarding the sample size

15

needed to discriminate between microenvironments with increased statistical significance. The

16

study results illustrate the utility of sequential measurement of microenvironments and policy-

17

relevant insights for exposure mitigation and management.

18

KEYWORDS

19

Exposure, transportation mode, fine particulate matter (PM2.5), carbon monoxide (CO)

2

ACS Paragon Plus Environment

Page 2 of 39

Page 3 of 39

Environmental Science & Technology

20

INTRODUCTION

21

Numerous epidemiological studies have demonstrated associations between traffic-related air

22

pollution exposure and a variety of adverse human health effects, including cardiopulmonary

23

mortality, respiratory mortality, chronic bronchitis, asthma attacks, low birth weight, and

24

childhood respiratory symptoms1-5 Exposure related to transport has been recognized as a key

25

target for public-health action in many places.4,6-8

26

Public transportation is extensively used in modern cities.9-11 Hong Kong is an example of a city

27

heavily reliant on public transport. In Hong Kong, 12 million public transport passenger journeys

28

are made daily, of which 41% are by Mass Transit Railway (MTR), a subway system, 32% are

29

via diesel-fueled single- or double-decker buses, 15% are via liquefied petroleum gas (LPG)

30

public minibuses, and 2% are by tram.12 People spend on average one to two hours daily in

31

transit.13-14 Exposure during public transportation may contribute to a significant fraction of daily

32

exposure.

33

Roadside fixed-site monitors are an indicator of traffic-related exposure. Such monitors are

34

placed closed to traffic emission, and can provide measurement data with instruments of high

35

precision and accuracy.15-18 A statistically significant high correlation of 0.92 was observed

36

between pedestrian PM2.5 exposure and ambient concentration recorded by a roadside monitor in

37

Bangkok.18 However, studies conducted in Europe indicate that a roadside monitor can be a poor 3

ACS Paragon Plus Environment

Environmental Science & Technology

38

indicator of personal exposure to PM (r