Solubility of Thiophene+ Pentane and Thiophene+ Octane Binary

Jun 14, 2005 - Octavio Elizalde-Solis and Luis A. Galicia-Luna*. Instituto Polite´cnico Nacional, ESIQIE, Laboratorio de Termodina´mica, Edif. Z, Se...
0 downloads 0 Views 128KB Size
Ind. Eng. Chem. Res. 2005, 44, 5757-5760

5757

GENERAL RESEARCH Solubility of Thiophene + Pentane and Thiophene + Octane Binary Mixtures in Supercritical Carbon Dioxide at Temperatures from 333 to 383 K Octavio Elizalde-Solis and Luis A. Galicia-Luna* Instituto Polite´ cnico Nacional, ESIQIE, Laboratorio de Termodina´ mica, Edif. Z, Secc. 6, 1ER piso, UPALM, C. P. 07738, Lindavista, Me´ xico D. F., Me´ xico

The solubility of thiophene + hydrocarbon mixtures in supercritical carbon dioxide was studied in this work. Phase behavior for the ternary system thiophene + pentane + carbon dioxide was measured at 333.66, 362.13, and 382.71 K. Additionally, behavior for the ternary system thiophene + octane + carbon dioxide was determined at 334.25, 363.73, and 383.28 K. Measurements were carried out to analyze the influence of pentane and octane on the solubility of thiophene in carbon dioxide. The results show that, for the system thiophene + pentane + carbon dioxide, the solubility of thiophene in carbon dioxide was higher than that obtained for the system thiophene + octane + carbon dioxide. The Peng-Robinson equation of state (PReos) using classical mixing rules was used to predict the experimental vapor-liquid equilibium (VLE) data of both ternary systems. The calculated values agree within an average absolute deviation