STANDARD SCIENTIFIC Supply Corp

graduated dial on front of the instrument. Knife edges are of hardened, polished steel. Bearing surfaces are of agate. Beam is provided with zero adju...
0 downloads 0 Views 2MB Size
NALGON flexibleplastic Tubing dimensional stability water-clear transparency high chemical resistance withstands autociaving

*β» j ϊγ-ψ& m

on

non-toxic economical absolute safety complete neutrality lasting flexibility heat resistance 4 0 different sizes cv&" ID to 2" ID)

PRODUCT

Our informative Catalog H-459 and a sample of NALGON will be sent re uest 1 • • · Write Dept. 22

W O R L D ' S

L A R G E S T

INSTRUMENTATION potentiometers a r c also coupled t o i t t o drive t h e recorders. T h e voltage across t h e p o t e n t i o m e t e r as well a s across t h e cold junction com­ pensation n e t w o r k is regulated w i t h Zener diodes. These various control devices a r e illustrated in Figure 1. Some other characteristics of this elegant i n s t r u m e n t a r e a s follows: Changes in sample weight from 0 t o 200 m g . can be m e a s u r e d w i t h a n a c ­ curacy of 1% of full scale with sample weights u p t o 10 grams. Controls p e r m i t t h e linear heating r a t e of t h e furnace t o be set a t 5 ° , 1 0 ° , 2 0 ° , 5 0 ° , 100°, 2 0 0 ° , 5 0 0 ° , o r 1000° C . per h o u r ; or for maintaining furnace a t constant t e m p e r a t u r e s . R e c o r d e r a d j u s t m e n t p e r m i t s X-axis spans (full scale deflection) for t e m ­ p e r a t u r e increments of 200°, 500°, a n d 1000° C . T h e T h e r m o - G r a v is a m o s t versa­ tile i n s t r u m e n t a n d can b e expected t o c o n t r i b u t e greatly t o a v a r i e t y of i n \ r cstigations.

TheNALGE Co. I n c . » m : i « n . j .

P R O D U C E R

O F

t

» l , i r i

P L A S T I C

L A B - W A R E

Circle No. 35 on Readers' Service Card

A New Concept in Moisture

Testing!

OHAUS MOISTURE DETERMINATION BALANCE A new type of balance for accurate determination of mois­ ture percent of any granular solid, semi solid or liquid which can be dried safely b y heat. A combination d r y i n g unit and precision balance f o r meas­ uring the moisture content o f 1 0 gram samples o f a w i d e vari­ ety o f materials w i t h a sensitivity of ± 0 . 1 % . Can aiso be used as direct reading balance, sensitivity 0.01 gram. Balance is o f the substitution type. Loss of w e i g h t caused by evaporation of moisture from the sample is compensated for by the a d d i t i o n of chain t o o n e arm of the beam by turning the graduated dial on front of the instrument. Knife edges are of hardened, polished steel. Bearing surfaces are of agate. Beam is p r o v i d e d w i t h zero adjustment and is magneticallv damped. Shadow-type indicating vane gives immediate indication o f balance position.

For Moisture Per Cent in:

The 6 5 0 w a t t infrared heater provides r a p i d , even evaporation and is adjustable both in percentage output and in distance above the sample. H e a t i n g chamber has heat-resistant handle and a Pyrex glass w i n d o w for observation of sample. Timer shuts off heat at any p e r i o d from 1 t o 6 0 minutes.

Cements, Chemicals, Detergents, Fertilizers, Flour, Food, G r a i n , Leather,

Cat. No. A 16080 Balance, Moisture Determination—Overall dimensions: 12'/ 2 x 10 χ 15 inches high. With 25 disposable pan liners. For 115 volts, 60 cycles A. G $295.00 Cat. No. A 16081 Pan Liners, Disposable—25 per box box $2.00

Paper, Pharmaceuticals, Seeds, Soils, Tobacco

STANDARD SCIENTIFIC

Supply

Corp.

8 0 8 NEW

B R O A D W A Y YORK 3, N Y .

Circle No. 113 on Readers' Service Card

80 A

·

ANALYTICAL CHEMISTRY

LABORATORY APPARATUS REAGENTS AND CHEMICALS

j I I

Figure 3. H e a t i n g system f o r vacuum thermobalance