The Fourth International Gas Chromatography Symposium - Analytical

Publication Date: September 1962. ACS Legacy Archive. Cite this:Anal. Chem. 34, 10, 77A-82A. Note: In lieu of an abstract, this is the article's first...
0 downloads 0 Views 2MB Size
ANALYTICAL CHEMISTRY

NEWS

The Fourth International Gas Chromatography Symposium H a m b u r g , G e r m a n y — A 10-Year A n n i v e r s a r y by Richard S. Juvet, Jr. Department of Chemistry, and Chemi­ cal Engineering University of Illinois, Urbana, Ill.

Several informal discussions of 1 t o 2 hours duration were organized to r u n concurrently with t h e regular scheduled sessions. Although these discussions will not a p p e a r in the Symposium P r o ­ ceedings, the free exchange of ideas given at these sessions was often par­ ticularly valuable. Informal discus­ sions were scheduled on trace analysis, inorganic analysis including transition metal halides, programmed t e m p e r a ­ t u r e G C , theory, flavor a n d essential oil analysis, t h e design and operation of detectors, and capillary column t e c h ­ nology.

T and

E N YEARS AGO in 1952, A. T. J a m e s

A. J . P . M a r t i n published a paper entitled, "Gas-Liquid Partition C h r o m a t o g r a p h y . " This p a p e r was destined to initiate one of the most actively investigated areas of analytical chemistry and to influence the research of scientists in all fields of chemistry. The F o u r t h International Gas Chro­ m a t o g r a p h y Symposium, marking the t e n t h anniversary of this i m p o r t a n t dis­ covery, was held J u n e 13-16 in the beautiful new Auditorium M a x i m u m of H a m b u r g State University. This is the newest University in t h e German Federal Republic and is situated in the largest industrial city in Federal Germany. T h e symposium a t t r a c t e d 694 registrants, an increase in a t t e n d ­ ance of 24 per cent over the previous International Symposium. Of these, 326 were from G e r m a n y and the Netherlands, 154 from Great Britain, 32 from the United States, and 14 from t h e Soviet bloc. F o u r registrants came from as far away as Australia. T h e symposium was organized b y t h e Analytical Chemical Division of the Gesellschaft Deutscher Chemiker and the Gas C h r o m a t o g r a p h y Discussion G r o u p under t h e auspices of the H y d r o ­ carbon Research G r o u p of the British I n s t i t u t e of Petroleum. Previous E u ­ ropean symposia have been held in London (1956), A m s t e r d a m (1958), and Edinburgh (1960). Welcoming addresses were presented b y D r . H . Kienitz, Chairman of the Analytical Chemistry Division of the Gesellschaft Deutscher Chemiker; D r . W. Drexelius, representative of the Senate of t h e City of H a m b u r g ; and D r . R . Sieverts, Rector of H a m b u r g State University. Following these ad­ dresses, opening lectures were pre­ sented b y early workers in the field of chromatography, R . K u h n , A. J. P . M a r t i n , and A. "V. Kiselev. K u h n dis­ cussed the development of a separation process; M a r t i n , in keeping w i t h his reputation as a prophet of future devel­ opments, discussed future possibilities in microanalysis and pointed out the

Theory

Dr. A. J. P. Martin, Nobel Prize winner for his discovery of partition c h r o m a ­ tography, is shown s p e a k i n g on fu­ t u r e possibilities in microanalysis a t t h e 4 t h International G a s Chroma­ tography Symposium need t o develop micro h a n d s a n d other micro instrumentation to handle the micro samples with which chemists of the future m a y be called u p o n to deal ; a n d Kiselev reviewed some adsorption studies, most of which h a d been carried out in Russia. One day each was devoted to sessions on Theory, A p p a r a t u s a n d Technique, and Applications. T h i r t y minutes were allowed each p a p e r for presentation and discussion. T h e 30 papers were a p ­ proximately evenly distributed between the G e r m a n and English languages. English p r e p r i n t s were mailed to all registrants prior t o the symposium al­ lowing time for preparation of con­ sidered contributions to t h e discussion; however, spontaneous contributions were also encouraged. An hour-long panel discussion, opened b y two short introductions, was also presented each afternoon. These included sessions on qualitative and q u a n t i t a t i v e aspects of G C a n d preparative-scale G C . B o t h t h e regular sessions and t h e panel dis­ cussions will a p p e a r in t h e "Proceed­ ings," of the H a m b u r g Symposium t o be published b y the end of this year.

T h e session on t h e o r y was opened b y K h a n who presented a nonequilibrium theory of capillary columns and de­ rived an equation for H E T P having identical form to t h e - Golay equation b u t including an additional t e r m ac­ counting for interfacial resistance, t h u s eliminating the restriction assuming dynamic equilibrium a t all points within the column. Several papers on adsorption chro­ m a t o g r a p h y and t h e measurement of heats of adsorption and adsorption iso­ therms were presented. Petrova, K h r a p o v a a n d Shcherbakova reported a study of physico-chemical adsorption characteristics b y G C methods. T h e rapidity with which heats of adsorption can b e measured b y G C compared w i t h the classical calorimetric method was emphasized. H u b e r and Keulemans compared t h e theoretical separating efficiency of gas solid a n d gas liquid chromatography in a paper- on non­ linear ideal c h r o m a t o g r a p h y and t h e potentialities of linear gas solid chro­ matography. Adsorption isotherms were constructed directly from chromatograms obtained with adsorption col­ u m n s demonstrating the validity of t h e t h e o r y developed. C. G. Scott meas­ u r e d the heats a n d standard entropies of adsorption for η-heptane, iso-octane, cyclohexane, and benzene on alumina modified b y heating a t elevated t e m ­ peratures with u p to 40 weight per cent sodium hydroxide. The aluminasodium hydroxide mixture, when used as a column packing material, gave symmetrical peaks for hydrocarbon VOL. 34, NO. 10, SEPTEMBER 1962 · 7 7

A

AUTOMATIC

NEWS

KARL FISCHER *

MOISTURE DETERMI NATION

The Karl Fischer method is now run on Technicon Auto Analyzer... Continuous / Automatic. Appli­ cable wherever Karl Fischer reagent is used. In the plant... AutoAnalyzer monitors and continu­ ously controls moisture in process streams. In the laboratory... AutoAnalyzer provides up to 40 determinations an hour automatically. Technicon® AutoAnalyzer® measures many other substances as well. Send for your free methodology literature kit KF2.

TECHNICON C O N T R O L S , INC. RESEARCH

PARK

·

C H A U Ν C Ε Υ, Ν . Y.

Circle No. 194 on Readers' Service Card

No surface protection n e e d e d

first cost is last cost

ALBERENE STONE

for 7 5 years t h e only perma­ nently satisfactory material for chemical laboratory table t o p s , shelving, sinks, splash backs, drain boards and fume hoods. Prompt delivery. ALBERENE S T O N E - A DIVISION OF THE GEORGIA MARBLE COMPANY. For FREE l i t e r a t u r e a n d t e c h n i c a l a s s i s t a n c e a d d r e s s : THE ALBERMAR COMPANY, 3 8 6 PARK AVE. SOUTH, NEW YORK 16, N. Y., DEPT. C Circle No. 1 on Readers' Service Card

7 8 A · ANALYTICAL CHEMISTRY

Main e n t r a n c e t o t h e A u d i t o r i u m Maximum, H a m b u r g S t a t e University

solutes. Partition and adsorption of these hydrocarbon solutes on a benzophenone-Celite column above and be­ low the melting point of the benzophenone was also studied. Vast differ­ ences were observed not only in reten­ tion volume, but also in elution order over small temperature changes near the melting point of the stationary phase. Desty, Swanton, and coworkers re­ ported that variations of solute reten­ tion with choice of carrier gas and column pressure are accounted for by changes in gas phase imperfections. Retention of a hydrocarbon solute on a particular stationary phase maintaining a constant column temperature and average column pressure decreases with carrier gas in the order helium, hy­ drogen, nitrogen, argon, oxygen, car­ bon monoxide, and carbon dioxide. The application of capillary columns for the accurate measurement of spe­ cific retention volumes and certain other fundamental thermodynamic quantities was compared by Adlard, Khan, and Whitham with similar meas­ urements carried out on packed col­ umns. It was found that a repro­ ducibility of about ± 1 % was ob­ tained for retention volumes, similar to results found for packed columns. It was pointed out that in certain respects capillary colums are more convenient for retention volume measurements. Freeguard and Stock discussed the advantages and disadvantages of a static method for measurement of ac­ tivity coefficient data at infinite dilution and made measurements with a McBain-type balance for comparison with gas chromatographic data. Studies of the partition isotherm and the effect of mixtures of liquid phases on the ab­ sorption of solute vapors were also reported.

NEWS Rotzsche prepared a series of cyanoalkyl substituted silicone oils and showed that the polarity, and hence the selectivity of these oils, could be changed by varying the number of nitrile groups in the molecule.

A p p a r a t u s and Technique An integrator making use of an analog digital converter coupled to the detector and the errors found for this arrangement were described by Kelker, Rohleder, and Weber. Golay, Ettre, and Norem presented a theoretical treatment for a pro­ grammed temperature gas chromato­ graphic system operated at constant inlet and outlet pressures as well as a nomographic solution for certain prob­ lems involved. Subambient pro­ grammed temperature techniques were discussed by Baumann, Klaver, and Johnson. An instrument useful from - 7 5 ° to +400° C. was described. Of the several liquid phases studied for application over wide temperature ranges, the nonpolar phase, silicone oil SF 96 (50) and polar phase, nitrile silicone fluid XF-1112 [both General Electric Co., Willoughby, Ohio], were found most useful at reduced tempera­ tures of —40° C. or below and yet were also useful at temperatures of 200° C. or above. Procedures for ap­ plying pressure drop corrections in PTGC were evaluated and the calcula­ tion of retention temperature from iso­ thermal data was illustrated. The performance of small diameter (1.5 mm.) columns packed with 3-6% hexanedione on 75- to 85-mesh firebrick and operated at high inlet pressures (up to 200 lb./sq. in.) was described by Amos and Hurrell. The columns pre­ pared had efficiencies of the order of 1000 plates per meter. Sample size for a C3-C5 hydrocarbon blend was restricted to less than 0.5 μΐ. to prevent overloading the column. The application of a catalytic com­ bustion cell as a sensitive detector was suggested in a paper prepared by Schay, Székely, and Traply. These authors point out that the sensitivity of a katharometer cell should be increased several orders of magnitude by running the cell at such a temperature that combustion takes place and advantage may be taken of the heat of combustion rather than simply the conductivity of the gas mixture. The cell was a 10-cm. glass capillary of 0.18 ml. volume containing an axial mounted platinum wire, 50 μ in diameter. When the wire was treated so that a catalytic coating was produced, a temperature of 200° in the presence of air as carrier gas was suf-

RADIATION INSTRUMENTS AND DETECTORS Liquid Scintillation Paper Chromatographic Scanner Density/Moisture Analyzers Transistorized Scalers Ratemeters 4TT Counter X-ray Proportional Counter Single Channel Spectrometer Laboratory Petroleum Sulfur Analyzer Portable Fast Neutron Monitor High P r e s s u r e Ion Chambers Area Radiation Monitoring Systems Personal Radiation Monitor Semi Conductor Nuclear Particle Detectors

NBCLEONIC PROCESS CONTROL EQUIPMENT Fixed Level Detector Systems Varying Level Detector Systems Density Analyzer Systems On-stream Petroleum Sulfur Analyzer Density/Moisture Gtfuges

RADIOACTIVE SOURCES AND COMPOUNDS Sealed Industrial Sources Research Sources Carbon-14, Tritium, Sulfur-35 Labelled Compounds

SHIELDING Isotope Shipping Casks Lead Disposal and Handling Containers Custom Lead Products Lead Bricks

SMALL PARTICLE SURFACE AREA APPARATUS All Metal Flow-type System All Metal Semi automatic B.E.T! System

ELECTROCHEMICAL ANALYTICAL INSTRUMENTS Controlled-Potential Coulometric Titrator (ORNL design) Controlled-Potential and Derivative Polarograph (ORNL design)

EDUCATIONAL MASS SPECTROMETI LOW VOLTAGE TRANSISTORIZED REGULATED POWER SUPPLIES

NUMEC Instruments and Controls Corporation

Apollo. Pennsylvania GRover 2-8411

Numinco Circle No. 205 on Readers' Service Card VOL. 34, NO. 10, SEPTEMBER 1962 · 7 9 A

MINI

NEWS

MONITOR THE ECONOMY TOOL FOR

ULTRA-VIOLET ANALYSIS OF COLUMN EFFLUENT

I n s t r u m e n t exhibition in the Lobby of the Auditorium Maximum, Hamburg State University

A great new labor-saver! Watches and records U V absorption of column effluent before the fraction collector, producing absorption peaks on a strip chart to tell you which fraction tubes contain material of interest. Entire instrument, including recorder, is self-contained in one cabinet only 7" cubed and weighing only 10 pounds. Mounts directly on the stand of any fraction collector. % T recording; 254 mu peak radiation; event m a r k e r to r e c o r d fraction changes; range expander for sensitivity adjustment. For use with proteins, nucleic acids, or other materials having reasonable absorption at 254 mu.

ORDER NOW FOR IMMEDIATE DELIVERY... ONLY $790 f.o.b.

Bethesda,

Md.

CANALCO CANAL INDUSTRIAL CORP. DepL A-J 4935 Cordell Avenue Bethesda 14. Maryland Circle No. 152 on Readers' Service Card 8 0 A

·

ANALYTICAL

CHEMISTRY

ficient for the combustion of even the slowest burning compounds. The sensitivity of detection was 12.5 mv. ju.gr1 seer 1 for amyl alcohol and was proportional to the heat of combustion of the solute. The combination of a conventional mass spectrometer with a gas chromatograph was shown to be useful for the identification of 37 components in a gasoline cut by Henneberg and Schomburg. The application of characteristic masses for class identification, such as mass 91 for alkylbenzenes, was reviewed. Jentzsch and Hôvermann, in a study of relatively large diameter (0.5 mm. i.d., 100 m. long), coated capillary columns, showed that samples as large as 50 jul. could be injected, allowing the use of thermal conductivity detectors and eliminating the need for sample splitters. Two methods for reducing tailing in capillary columns were suggested: (1) coating the capillary with an inert, temperature-stable "intermediate phase" such as silicone rubber SE-52 [General Electric Co.] prior to application of the stationary phase and (2) the addition of a corrosion inhibitor such as "Alkaterge T," as originally proposed by Averill at the 1961 Michigan State Symposium. The hydrogen isotopes and nuclear spin isomers, ortho- and parahydrogen, ortho- and paradeuterium and hydrogen deuteride were completely separated by Mohnke and Saffert by adsorption chromatography using capillary columns operated at 77.6° K. A 20 μ thick adsorptive layer on the inner wall of a glass capillary 80 m. in length

was prepared by etching the sealed capillary with a 17% aqueous ammonia solution at 170° for 70 hours. Neon was used as carrier gas. Schulz presented a quantitative dis­ cussion of the continuous countercurrent separation of a number of binary mixtures. A feed mixture of isobutene (b.p., —6.9°) and n-butene-1 (b.p., —6.26°) was separated, with both com­ ponents being reclaimed in greater than 99% purity, by continuous feed­ ing of the mixture into the center of the column while allowing a sorption material of silver nitrate in benzyl cyanide on Sterchamol to move in a countercurrent direction to the carrier gas flow. Kaiser and Kienitz pointed out that gas chromatographic equipment could pay for itself within a period of 10 days to 1 month when used under the right conditions in process control systems. The application of a process control unit to distillation problems was re­ viewed.

Applications T. R. Phillips and D. Neylan pre­ sented a statistical study of factors af­ fecting column performance in the separation of halogen and interhalogen compounds on Kel-F oils. One obser­ vation, not in accordance with estab­ lished theory, was that a liquid phase loading of 20% Kel-F oil on Kel-F Grade 300 molding powder gave better column performance with 50-70 mesh particles than with finer size particles while a high loading of 80% gave better

NEWS performance on finer particles of 70to 80-mesh. The authors explained this result by pointing out that the support was chemically similar to the liquid phase in these experiments and cannot be regarded as inert. A method for the determination of separation factors from unresolved twocomponent peaks was developed by Sideman and Giladi. A study of nitro­ gen isotope enrichment was used as an application of this method. A separa­ tion factor of 1.0011 for a 28/29 nitro­ gen isotope mass ratio obtained experi­ mentally was in good agreement with the value 1.0007 calculated from vapor pressure measurements. A detailed description of a GC ap­ paratus useful for the qualitative and quantitative analysis of microgram amounts of flavor volatiles from edible fats was given by Swoboda. Individ­ ual peaks were identified with the aid of Kovats' retention index method and the determination of the carbon skele­ ton by catalytic reduction of the com­ ponent to its corresponding hydrocar­ bon followed by GC identification of the product formed. Schomburg reviewed the chemistry of boron alkyls and hydrides and demonstrated the value of GC for de­ termining equilibrium concentrations of products formed in the transalkylation of boron alkyls, boracyclanes, and bisborolanes. Grant and Vaughan prepared trimethyl silyl ethers of phenols with hexamethyldisilazane for the separa­ tion of complex phenolic mixtures. Glass capillary columns coated with silicone oil MS 550 [Midland Silicones Ltd.] gave well defined symmetrical bands for silylated phenols, cresols, and xylenols boiling in the range 190300° C. The analysis of millimicroliter quan­ tities of the permanent gases hydrogen, oxygen, nitrogen, argon, methane, car­ bon monoxide, carbon dioxide, krypton, xenon, and neon was described by Berry. An ionization detector with high purity helium used as carrier gas was employed [metastable (23S) he­ lium atoms, 19.8 eV energy]. The limit of detection ranged from 5 X 10~8 to 5 Χ 10 -7 cc. of the permanent gases. A method for adequately purifying the helium carrier gas and the variation of detector signal with flow rate, gas pres­ sure, and detector temperature were discussed in detail. Trace analysis of hydrocarbons (up to C e ) was performed by Huyten, Rijnders and van Beersum on alumina columns containing ca. 2% water. Ap­ paratus was described which is useful for direct quantitative analysis in con­ centrations down to ca. 0.003 p.p.m.

Pt for

the

lab STANDARD LAB APPARATUS: a

complete

line of quality

SPECIAL LAB EQUIPMENT . send

us your

specifications

CHEMICALS: over

40 salts, solutions, powders

ware

in stock

Whatever your need for platinum, take advantage of BISHOP'S long experience (since 1842) and complete facilities for the fabrication, refining and recovery of the platinum group metals. And don't forget that your used lab ware and other platinum material has a high scrap value toward the purchase of new products. Send for our catalog PLATINUM

HMWJ* METMS wwooers

M E T A L S PRODUCTS N O .

P-6.

BISHOP J . B I S H O P & C O . platinum MALVERN, A

J O H N S O N

works

PENNSYLVANIA M A T T H E Y

A S S O C I A T E

Circle No. 51 on Readers' Service Card

VOL. 34, NO. 10, SEPTEMBER 1962 · 81

A

NEWS

HOW IWfflffillll DIETERT-DETROIT (BAHC0)

MICRO-PARTICLE CLASSIFIER

4principal

uses are:

Π

CLASSIFYING laboratory quantities of fine materials for product or new material research.

Q

CONTROLLING industrial processes using or producing fine materials.

0

DETERMINING the separating efficiency of air cleaners.

E l

PRE-TESTING dust collector requirements.

DETERMINE PARTICLE SIZE DISTRIBUTION below 60 microns, in materials such as: Beryllium Powder Grinding Sand Catalysts Metal Oxides Ceramic Powders Penicillin Chemicals Polymers Diatomaceous Earth Powdered Metals Drugs Milk Solids Dry Powders Standard Dust Fly Ash Samples

H A R R Y W. D I E T E R T CO. CONTROL 9330 R o s e l a w n

EQUIPMENT · D e t r o i t 4, Mich.

Send me details on Micro-Particle Name

Classifier

,

Address Company City

State

Circle Να. 63 on Readers' Service Card 8 2 A · ANALYTICAL CHEMISTRY

CALENDAR OF EVENTS Aug. 29 to Sept. 5

Fifth International Congress for Electron Microscopy, Philadel­ phia, Pa. Host: Electron Microscope Society of America. Con­ tact: Fifth International Congress for Electron Microscopy, 7701 Burholme Ave., Philadelphia 11, Pa. Page 50 A, Nov.

Sept. 5 to 7

Symposium on Measurement of Thermal Radiation Biltmore Hotel, Dayton, Ohio. Sponsors: U . S. National Bureau of Standards, National Aeronautics Administration. Contact: C. R. Andrews, University Dayton 9, Ohio. Page 53 A, June.

Sept. 9 to 14

American Chemical Society, 142nd National Meeting, Atlantic City. N . J . Page 39 A, Aug.

Sept. 10 to 15

International Symposium on Molecular Structure and Spectros­ copy, Tokyo, Japan. Sponsor: International Union of Pure and Applied Chemistry and Science Council of Japan. Contact : Secretary, International Symposium on Molecular Structure and Spectroscopy, Science Council of Japan, Ueno Park, Tokyo, Japan. Page 105 A, Feb.

Sept. 16 to 20

Second Annual Conference on Pharmaceutical Analysis, Kings Gateway, Land O'Lakes, Wis. Contact: R. S. Strommen, Uni­ versity of Wisconsin, Madison 6, Wis.

Sept. 16 to 22

Eighth Latin American Congress of Chemistry, Buenos Aires. Contact: Secretaria, Octavo Congreso Latino-Americano de Quimica, Casilla Correo 2153, Buenos Aires, Argentina. Page 105 A, Feb.

Sept. 17 to 19

Ninth Ottawa Symposium on Applied Spectroscopy, Ottawa, Canada. Sponsor: Canadian Association for Applied Spectros­ copy. Contact: Ben Farrar, J . T . Donald & Co., Ltd., 1181 Guy St., Montreal 25, Quebec. Page 63 A, March.

Sept. 26 to 28

Practice of Gas Chromatography. Michigan State University. Sponsors: ASTM Committee E-19 and Michigan State Univer­ sity. Contact: Nathaniel Brenner, T h e Perkin-Elmer Corp., Norwalk, Conn. Page 46 A, April.

Drawert reviewed several applica­ tions of chemical reactors positioned just ahead of the chromatographic column. The analysis of the lower fatty acids in the stomach of Colobinae monkeys was carried out· by esterification with methanol/boron trifluoride reagent. The esterified frac­ tion was then injected directly into a calcium hydride reactor for removal of water and acids without need for prior isolation of the esters. C14-labeled al­ cohols in aqueous solution were ana­ lyzed by dehydration to C14-olefins in an appropriate chemical reactor and de­ tection of the olefins at the column out­ let with proportional counting equip­ ment. The partial thermal decomposition and cracking patterns of some 23 hy­ drocarbons up to C 1 0 were studied by Keulemans and Perry. For controlled decomposition the sample was exposed for 20 sec. to temperatures of approxi­ mately 500° C , and quantitative meas­ urements of the decomposition prod­ ucts were made. Stability to thermal decomposition decreases in the order: double bonds, single bonds adjacent to

of Solids. Air Force, and Space of Dayton,

double bonds, single bonds. The re­ producibility of cracking pattern and the influence of cracking temperature and sample size were briefly discussed. The symposium was adjourned fol­ lowing closing addresses by W. W. Brandt and C. S. G. Phillips. Although some were heard to say that much of the work presented at this symposium represented important improvements of existing technology rather than major new developments or breakthroughs, still interest remains high as judged by continually increasing attendance. Gas chromatography will undoubtedly maintain a leading position in the in­ terest of analytical chemists for many years to come.

X-Ray School The 43rd Norelco X-Ray Analytical School will be held at the Sir Francis Drake Hotel, San Francisco, during the week of September 10-14, 1962. Write to: Philips Electronic Instruments, 750 South Fulton Ave., Mount Vernon, Ν. Υ.